WHAT ARE THE SPECIFICATIONS FOR THE ARGON GAS OPTION USED IN JOULE THOMSON REFRIGERATORS?

Similar documents
Optimizing Gas Supply for Industrial Lasers

PRODUCT GUIDE Spring 2015

Customer Responsibilities

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

PURPOSE OF THE POLICY

DESIGN DATA. Dry 105a. September 5, 2008

490 Micro GC Site Preparation Checklist

490 Micro GC Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Customer Responsibilities

Judson Technologies PB 219. JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM Operating Instructions. October, 2003

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

TELEDYNE PB 219. JUDSON TECHNOLOGIES A Teledyne Technologies Company TELEDYNE JUDSON TECHNOLOGIES JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Data Sheet Issue A

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

ONB/MHPQ/MDIS/ /Q22

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Unit 14 Gas Laws Funsheets

MATHESON s LaserPro Gases and Gas Delivery Equipment

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

LIQUID CYLINDER OPERATING MANUAL

UltraLo 1800 Alpha Particle Counter

Gas Mixture Two Components. Gas Mixtures Two Components

SG3 Series Regulators - Pressure Reducing

Micro GC Fusion Pre-Installation Checlist

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Pressure Gauges Accessories

Data Sheet Issue A

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

CYLINDER VALVE GUIDELINES TD 12/15/E

Safe Handling Methylamine (Monomethylamine)

TECHNICAL DATA. Q = C v P S

Customer Responsibilities

Nordiko Metal Sputtering System Standard Operating Procedure

Physics 7b Midterm Exam #1 Fall Name: Disc. Section SID

Customer Responsibilities

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

Compressed Gas Outlets and Inlets 41 Gas Cylinders and Packs 49. Packaging Data. SGEM 2006: Section 3 [Packaging Data] 39

ASSIGNMENT 2 CHE 3473

MATERIAL SAFETY DATA SHEET

ASSIGNMENT 2 CHE 3473

TECHNICAL DATA. Q = C v P S

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

A-A June 2000 SUPERSEDING BB-N-411C 3 January 1973 COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

SG2 Series Regulators - Pressure Reducing

GASES PROCESS CHEMICAL SPECIALTY. Gases. Pure Gases & Gas Mixtures. VOC Mixtures EPA Protocols. Propane Methane Nitrogen Air Acetylene Propylene Argon

Name /74. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

Summary of the MRA LPG Codes of Practice

Safe Handling - Dimethylamine

28 Site Preparation. Supplying valve actuator air

World Area Differences Technical Information


take a deep breath... Dependable high quality breathing air compressors

The Hoffman Specialty Series 2000 consists of main

Nonrefillable Cylinders

N 2 DESIGN AND PRODUCTION OF LABORATORY GAS GENERATORS NITROGEN GENERATORS WITH INTEGRATED COMPRESSOR

Minimum test pressure (psig) 2. Requalification period (years) DOT psig 5. non-corrosive service ( see

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

SG1 Series Regulators - Pressure Reducing

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

ASSE International Product (Seal) Listing Program

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

Avio 500 ICP-OES. ICP-Optical Emission Spectroscopy PREPARING YOUR LAB. Preparation Checklist. Suitable Working Area

MicroBulk Solutions. Next Generation Solutions for Safe and Efficient Delivery for Gas and Liquid Applications

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Chlorine Supply Containers And Piping

Description Advanced Features Typical Applications

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Gases. Unit 10. How do gases behave?

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Ensuring cryogenic supply capabilities. Any application - Any time

To convert to millimeters of mercury, we derive a unit factor related to the equivalent relationship 29.9 in. Hg = 760 mm Hg.

Compressed Gas Cylinder Safety

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

BOYLE S LAW: Use Boyles Law to answer the following questions. Show all work and include units to receive full credit. Answers are in bold.

Storage Systems and Accessories

Check & Demo Shielding Gas Waste. Index

Transcription:

MMR Technologies, Inc. WHAT ARE THE SPECIFICATIONS FOR THE ARGON GAS OPTION USED IN JOULE THOMSON REFRIGERATORS? Joule Thomson refrigerators operate using high pressure gas to cool a sample stage with high temperature precision and very low noise. The most commonly used gas is nitrogen gas. There are times when argon is preferred - specifically when higher cooling capacity is necessary. Nitrogen gas gives a cooling capacity of 250 mwatts at 85K. Argon gas gives a cooling capacity of 500 mwatts at 90K. In order to ensure maximum performance of the Joule Thomson refrigerator, with minimum operational problems, the type of argon gas used is very important. The argon gas should be Pre-purified Grade purity and should be delivered in a tank at an initial pressure of at least 2640 psi. This gas can be obtained from local sources. It cannot be supplied by MMR Technologies. Shipment of high pressure gas cylinders is so highly regulated that shipment by air is not possible and shipment over long distances by truck is not economically viable. The user should order a supply of this gas well in advance of receiving delivery of the cryogenic cooling system. ARGON GAS SPECIFICATIONS Gas Data Formula: Ar Molecular Weight: 39.95 Specific Volume: 9.70 ft. 3 /lb. (0.60 m 3 /kg) CAS Registry No.: 7440-37-1 Cylinder Specifications Argon gas can come in a variety of sizes and pressures. Table 1 gives some specifications for some of the more commonly used cylinders. This is by all means not a comprehensive list. TSB-004 Revision B 1

TABLE 1: ARGON GAS SPECIFICATIONS VALVE OUTLET PRESSURE AT 70F (21.1 C) 1A CGA Number 580 2,490 psi (17, 180 kpa) 1L CGA Number 580 2,640 psi (18, 216 kpa) 1H CGA Number 680 3,500 psi (24, 130 kpa) 1U CGA Number 677 6, 000 psi (41, 370 kpa) 2, 3, & 4 CGA Number 580 2,000 psi (13, 800 kpa) NOTE Joule Thomson refrigerators require a minimum tank pressure of 1800 psi to operate. It is recommended that the minimum delivered tank pressure is 2640 psi. NOTE When the argon tank being used for the Joule Thomson refrigerators gets below 1800 psi the tank can still be used for other applications, including acting as a back fill source of argon for the vacuum chambers or for other laboratory experiments where lower pressure argon is required. Shipping Data D.O.T. Proper Shipping Name: Argon, Compressed Hazard Class: 2.2 (Nonflammable Gas) I.D. No.: UN 1006 E.R.G. Page: 12 Label(s): Nonflammable Gas Summary of Argon Gas Specifications MMR Technologies, Inc. recommends that the argon gas used with the Joule-Thomson refrigerators meets the following criteria: Pre-purified Grade 99.998% minimum purity 1800 psi supplied pressure from the tank Tank pressure recommended to be at least 2640 psi The argon gas must go through a filter/dryer apparatus prior to going into the Joule Thomson refrigerator (There are three available kits from MMR Technolo- Revision B 2

gies. For further information, please refer to the Technical Support Bulletin on the Importance of Using Filter/Dryers with your Joule Thomson Refrigerators.) There are several basic tanks that meet this qualifications. Consider the following three tables, where different tank pressures of 99.998% pure argon gas are described with respect to their contents: TABLE 2: ARGON, PRE-PURIFIED, 99.998% CONTENTS FT. 3 M 3 LBS KG 1L 331 9.37 34.13 15.49 1A 280 7.93 28.86 13.09 2 88 2.49 9.07 4.11 3 35 0.99 3.61 1.64 4 12 0.34 1.24 0.56 TABLE 3: ARGON, 3500 PSI, 99.998% MIN. CONTENTS FT. 3 M 3 LBS KG 1H 386 10.93 39.79 18.06 TABLE 4: ARGON, 6000 PSI, 99.998% MIN. CONTENTS FT. 3 M 3 LBS KG 1U 570 16.14 58.76 26.66 Several types of cylinders have been described in this technical support bulletin. In order to determine the best type of cylinder for your applications and requirements, some further information on these basic cylinder types can be seen in Table 5 on page 4. Revision B 3

TABLE 5: DIMENSION, WEIGHT AND CAPACITY INFORMATION ON COMMON S NOMINAL DIMENSIONS (DIAMETER X LENGTH) TARE WEIGHT WATER CAPACITY INTERNAL VOLUME INCHES CM LBS KG LBS KG CU. FT. LITERS 1A 9 x 51 23 x 130 122 55 96 43.5 43.8 1.55 1L 10 x 55 24 x 140 138 63 108 49.0 49.0 1.73 1H 9 x 51 23 x 130 188 85 96 43.5 43.8 1.55 1U 10 x 51 25 x 120 312 141 93 42.2 42.4 1.50 2 9 x 26 22 x 65 64 29 36.8 16.7 16.7 0.59 MMR TECHNOLOGIES CRYOCOOLER OPERATING TIME AS A FUNCTION OF STORAGE TANK AND PRESSURE Another important consideration when deciding which argon gas tank to use with your cooling system is the length of time the experiments are expected to take, and how long the tank of argon gas will last. There are several variables that are important in this: Tank Size Tank Pressure The usage rate of the refrigerator While the first two variables are intuitive, the usage rate of the refrigerator can vary from system to system, and from experiment to experiment, depending on the types of samples being cooled, the experimental conditions, the cooling requirements on the system, and the vacuum pressure within the chamber housing the Joule Thomson refrigerator. There are also slight variations from refrigerator to refrigerator. With that in mind, Table 6 will suggest some typical usage times that can be expected. Revision B 4

TABLE 6: OPERATING TIME FOR A TANK OF ARGON GAS AS A FUNCTION OF THE AND PRESSURE OF THE SUPPLY TANK TANK ID EQUIVALENT STP VOLUME OF ARGON IN THE TANK AT STP VOLUME AVAILABLE FOR REFRIGERATOR USAGE RATE OF REFRIGERATOR OPERATING TIME AS A FUNCTION OF DELIVERY USE TANK PRESSURE 1L 211.0 cu. ft. 98.5 cu. ft. 2 cu. ft. / hr. 49 hours 3 cu. ft. / hr. 33 hours 4 cu. ft. / hr. 25 hours 5 cu. ft. / hr. 20 hours 1A 189.0cu ft. 72.5 cu. ft. 2 cu. ft. / hr. 36 hours 3 cu. ft. / hr. 24 hours 4 cu. ft. / hr. 18 hours 5 cu. ft. / hr. 15 hours 1H 189.0 cu. ft. 178.5 cu. ft. 2 cu. ft. / hr. 89 hours 3 cu. ft. / hr. 60 hours 4 cu. ft. / hr. 45 hours 5 cu. ft. / hr. 36 hours 1U 183.0 cu. ft. 426.8 cu. ft. 2 cu. ft. / hr. 213 hours 3 cu. ft. / hr. 142 hours 4 cu. ft. / hr. 107 hours 5 cu. ft. / hr. 85 hours 2 72.0 cu. ft. 8 cu. ft. 2 cu. ft. / hr. 4 hours 3 cu. ft. / hr. 2.7 hours 4 cu. ft. / hr. 2.0 hours 5 cu. ft. / hr. 1.6 hours Revision B 5

FURTHER QUESTIONS If you have further questions, please do not hesitate to contact MMR Technologies, Inc: Phone: +1 (650) 962-9620 Fax: +1 (650) 962-9647 Email: Sales@mmr.com Web: www.mmr.com Revision B 6