O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

Similar documents
The MAXX Press DIGITAL CAP OPERATOR S MANUAL

D I G I T A L C L A M

A U T O O P E N S E R I E S C A P P R E S S O P E R A T O R S M A N U A L

Digital Clam / Cap Operator s Manual

A I R S W I N G E R O P E R A T O R S M A N U A L

Universal Valve Company Inc

Universal Valve Company Inc

MODEL NUMBER: P PORTABLE COMPRESSOR

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

MODEL NUMBER: P PORTABLE COMPRESSOR

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Portable Oil Lube Air Compressors

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Powermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

accidents which arise due to non-observance of these instructions and the safety information herein.

User Manual for the Mars Calibration Bench

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

Budget Range Operators Handbook

Ecomow Electric Mower

icreasepro Creaser Operators Manual

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

LSX Low Smoke Convertor Operations Manual

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

CircuFlow Quick Setup Guide

! Warning, refer to accompanying documents.

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

CAUTION: YOU MUST READ THE FOLLOWING BEFORE OPERATING THE SNOWMAN.

Model 130M Pneumatic Controller

User Manual GRI- 1500Li

VERTICAL AIR COMPRESSORS

HAS2400 Hepa Air Scrubber

COMPRESSOR AND INFLATOR WITH TORCH

SILENTAIRE TECHNOLOGY

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

TrekMill USER'S MANUAL MM5050

High Power Commercial Blenders

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

R E D I C O N T R O L S

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

36H SERIES Combination Gas Valve

G2W PRO ROBOT. User Manual. paddlepalace.com

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

03/07/2014 V

Operator: Save these instructions for future use!

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL

Operator: Save these instructions for future use!

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Read Before Operating!

INSTALLATION GUIDE Gas Rangetops

Propane Conversion Kit Instructions

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

VERTICAL AIR COMPRESSORS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

WELCOME TO THE REVOLUTION

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

12V AIR STATION ALL-IN-ONE

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

LNVx Gas Conversion Kit Instructions

Issue 3. Module TS11. Failure of, or work on, signalling equipment signallers regulations. GERT8000-TS11 Rule Book

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Heavy-Duty Hot Knife

444C DUAL PERFORMANCE VALUE PACK

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

400C & 450C DUAL PERFORMANCE VALUE PACKS

Instructions for High Altitude Conversion

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

User Manual: Ozone Swim 1000, 2000 and 3000 Series

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

Operator: Save these instructions for future use!

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Fiber Cable Puller with Tuf-Lugger lite

SAFETY & OPERATING INSTRUCTIONS

5KSB1585 5KSB1586 W B_v02.indd 1 7/8/15 1:45 PM

USER MANUAL

Transcription:

Clam Basic Series O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

Safety Instructions When using your heat press, basic precautions should always be followed, including the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Read all instructions. Use heat press only for its intended use. To reduce the risk of electric shock, do not immerse the heat press in water or other liquids. Never pull cord to disconnect from outlet, instead grasp plug and pull to disconnect. Do not allow cord to touch hot surfaces, allow heat press to cool completely before storing. Do not operate heat press with a damaged cord or if the equipment has been dropped or damaged. To reduce the risk of electric shock, do not disassemble or attempt to repair the heat press. Take it to a qualified service person for examination and repair. Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when the equipment is used. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Close supervision is necessary for any heat press being used by or near children. Do not leave equipment unattended while connected. Burns can occur when touching hot metal parts. To reduce the likelihood of circuit overload, do not operate other high voltage equipment on the same circuit. If an extension cord is necessary, then a 20 amperage rated cord should be used. Cords rated for less amperage may overheat. Care should be taken to arrange the cord so that it cannot be pulled or tripped over. S A V E T H E S E I N S T R U C T I O N S

CLAM BASIC Table of Contents Clam Basic Safety Instructions 2 Machine View Control Panel Operating Instructions Connecting and Starting the System Adjusting the Temperature and Time Adjusting the Pressure and Pressing Electrical Schematic 4 5 6-8 6 7 8 9 Cap Basic Machine View 10 Operating Instructions Connecting and Starting the System Adjusting the Temperature, Time and Pressure Pressing Electrical Schematic Contact 11-13 11 12 13 14 15 The Clam Basic is available in 6 colors* *Some restrictions apply, please contact us for details 3

CLAM BASIC Machine View Power ON/OFF Switch ON Over-the-Center Pressure Adjustment Knob Clam Basic Lift Handle OFF Circuit Breaker Power Cord LED Display Sizes Available: 11 x 15 15 x 15 16 x 20 Upper Platen Lower Platen Base 4

CLAM BASIC Control Panel Digital Display Temperature Indicator Set Indicator Time Indicator Increase Mode Select Decrease 5

CLAM BASIC Operating Instructions Clam Basic The Clam Basic Operating Instructions are designed with the user in mind. Carefully read and follow the step-by-step instructions for best results. To avoid burns, do not touch the heated platen during use. Keep hands clear of the upper platen of the press during platen lock down as the pressure may cause injury. Press should be placed on a sturdy, suitable stand at least 36 L x 24 W x 29 H. Work area must be kept clean, tidy and free of obstructions. Power supply cord must be disconnected before cleaning or servicing press. Connecting /Starting the System 1. Connect the power cord into a properly grounded electrical outlet with a sufficient amperage rating. Your Clam Basic requires a full 10 amp grounded circuit for both 120 volt and 220 volt operation. Extension Cords, if used, should be as short as possible and not less than 12 gauge. Heavy duty cords are recommended. Circuits that have under 10 amps or other high demand equipment or appliances (especially more than one heat seal machine) should not be used. Note: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid hazard. Use SJT type, rated 300 V for replacement. CAUTION: Failure to follow these instructions can cause erratic controller functions, inaccurate displays, slow heat-up and can cause the circuit breaker to disengage. 2. Switch The System On: Locate the lift handle and position the heat platen in the up (load) position. Locate the Power ON/OFF Switch on the press. Turn the Power Switch on. ON OFF Power ON/OFF Switch 6

CLAM BASIC Adjusting the Temperature /Time 3. To Adjust the Temperature: Locate the LED Display on the Press. Press the Mode Select button located in the center of the Control Panel. The (SET) and (TEMP) lights located next to the display will illuminate indicating you are in the adjust temperature mode. Next, press the (-) button located to the left of the Mode Select button to lower the temperature setting, or press the (+) button located to the right of the Mode Select button to raise the temperature setting. The temperature can be set from 205 F (96 C) to 430 F (220 C). The LED will display changes as you make them. Note: The temperature indicator will only display temperatures 200 F (93 C) and up. Digital Display Temperature Indicator Set Indicator Time Indicator 4. Adjust the Time: Once you have completed adjusting the temperature, press the Mode Select Button again. This will advance you to the Adjust Time Mode. The (SET) and (TIME) Lights will illuminate, indicating you are in the Adjust Time Mode. Note: The press will not function when the (SET) Light is illuminated. This light indicates that you are in the Adjust Temperature or Time Mode not the Print Mode. Increase Mode Select Decrease Adjust the time in the same manner that you adjusted temperature. The time can be set from 001 to 999 seconds. To exit the Adjust Temperature and Time Modes, press the Mode Select Button a third time. All lights will be off and the press will return to the Print Mode. 7

CLAM BASIC Operating Instructions Adjusting the Pressure 5. To Adjust the Pressure: The Pressure Adjustment Knob is located in the center of the heat platen. Pressure Adjustment Knob Adjust the pressure by turning the knob clockwise to increase pressure or counter clockwise to decrease pressure. REMEMBER: To allow for the thickness of your garment when adjusting the pressure. WARNING: Structural damage caused by excessive pressure is not covered under the limited warranty! Pressing 6. Pressing: Once your equipment has reached the designated temperature, position the garment and application and proceed to press. Lower and lock the heat platen into the press position. This procedure will start the automatic timing process. The timer will automatically count down and audibly signal you to lift the heat platen into the UP position when the press cycle is complete. Note: The time will automatically re-set and you are ready to continue with the next application. 8

Electrical CLAM Schematic BASIC US 120 V VERSION 1800 W HEATER (1000 W for 11 x 15) 1800 W HEATER (1000 W for 11 x 15) (220 V) US 220 V VERSION 230 V VERSION 1800 W HEATER (1000 W for 11 x 15) (230 V) 230 V 9

CAP BASIC Machine View Cap Basic Lift Handle Upper Platen LED Display Lower Platen Pressure Adjustment Knob Base Cap Hold Down Lever Circuit Breaker Power ON/OFF Switch Power Cord 10

CAP BASIC Operating Instructions The Cap Basic Operating Instructions are designed with the user in mind. Carefully read and follow the step-by-step instructions for best results. To avoid burns, do not touch the heated platen during use. Keep hands clear of the upper platen of the press during platen lock down as the pressure may cause injury. Press should be placed on a sturdy, suitable stand at least 36 L x 24 W x 29 H. Work area must be kept clean, tidy and free of obstructions. Power supply cord must be disconnected before cleaning or servicing press. Connecting /Starting the System 1. Connect the power cord into a properly grounded electrical outlet with a sufficient amperage rating. Your Cap Basic requires a full 10 amp grounded circuit for both 120 volt and 220 volt operation. Extension Cords, if used, should be as short as possible and not less than 12 gauge. Heavy duty cords are recommended. Circuits that have under 10 amps or other high demand equipment or appliances (especially more than one heat seal machine) should not be used. Note: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid hazard. Use SJT type, rated 300 V for replacement. CAUTION: Failure to follow these instructions can cause erratic controller functions, inaccurate displays, slow heat-up and can cause the circuit breaker to disengage. 2. Switch The System On: Locate the lift handle and position the heat platen in the up (load) position. Locate the Power ON/OFF Switch on the back of the press. Turn the Power Switch on. ON OFF Power ON/OFF Switch 11

CAP BASIC Operating Instructions Adjusting the Temperature /Time 3. Refer to page 7 for Adjusting the Temperature and Time: Digital Display Temperature Indicator Set Indicator Time Indicator Increase Mode Select Decrease Adjusting the Pressure 4. To Adjust the Pressure: The Pressure Adjustment Knob is located below the lower heat platen. Adjust the pressure by turning the knob clockwise to increase pressure or counter clockwise to decrease pressure. REMEMBER: To allow for the thickness of your cap when adjusting the pressure. WARNING: Structural damage caused by excessive pressure is not covered under the limited warranty! Pressure Adjustment Knob 12

CAP BASIC Pressing 5. To begin printing: Once your equipment has reached the designated temperature: Pull the Cap Hold Down Lever up and towards the operator and load the cap onto the lower platen. Pull out the sweatband and position the cap so that it clears the upper platen when the machine is closed. Push the Cap Hold Down Lever down and away from the operator. This will stretch and hold the cap from moving. Position your application, then lower and lock the heat platen into the press position. This procedure will start the automatic timing process. The timer will automatically count down and audibly signal you to lift the heat platen into the UP position when the press cycle is complete. The time will automatically re-set and you are ready to continue with the next application. Cap Hold Down Lever 13

CAP BASIC Electrical Schematic US 120 V VERSION US 240 V VERSION 230V VERSION 14

Contact us STAHLS International 20600 Stephens Street St. Clair Shores, MI 48080 U.S.A. phone (001) 586. 772. 5551 fax (001) 586. 772. 6237 email info@stahlsinternational.com web StahlsInternational.com Designed in the USA by STAHLS. Assembled and manufactured in China. This document includes multiple trademarks and describes equipment covered by many patents that are owned by GroupeSTAHL and/or its subsidiaries. GroupeSTAHL enforces its rights to protect these intellectual properties. 2012

2 0 6 0 0 S t e p h e n s S t r e e t S t. C l a i r S h o r e s, M I 4 8 0 8 0, U. S. A. t ( 0 0 1 ) 5 8 6. 7 7 2. 5 5 5 1 f ( 0 0 1 ) 5 8 6. 7 7 2. 6 2 3 7 e i n f o @ s t a h l s i n t e r n a t i o n a l. c o m w S t a h l s I n t e r n a t i o n a l. c o m