MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

Similar documents
REF CH-302B IDENTIFICATION OF PARTS

REF CH-602B IDENTIFICATION OF PARTS

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

Digital Blood Pressure Monitor. Model UA-787

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Auto Arm Blood Pressure Monitor

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

INSTRUCTION MANUAL FOR CITIZEN SELF-STORING BLOOD PRESSURE ARM MONITOR

Contents. Safety Notice. Wrist Type

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

Semi-Automatic Blood Pressure Monitor with Memory

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

VER: A00. Model No:BA2010

Fully Automatic Blood Pressure Monitor

Sports Wrist Digital Blood Pressure Monitor Item #

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Operating Instructions Instrucciones de funcionamiento

Instructions. Upper Arm Blood Pressure. Model EW3153

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

Check following components!

Instruction Manual. Auto Inflate Blood Pressure Monitor

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Blood Pressure Monitor

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Blood Pressure Monitor

TD-3140 Blood Pressure Monitor. Owner s Manual

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Blood Pressure Monitor

Blood Pressure Monitor

TD-3140 Blood Pressure Monitor. Owner s Manual

SBC 21. Electromagnetic Compatibility Information

Blood Pressure Monitor

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

5 series Blood Pressure Monitor

premium wrist blood pressure monitor

Wrist Type Blood Pressure Monitor

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Model M3 Intellisense

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

Wrist Blood Pressure Monitor Model R2

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Blood Pressure Monitor

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

LD6. Digital Blood Pressure Monitor Instruction Manual

Automatic Blood Pressure Monitor Model M6 Instruction Manual

Content

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

LD22. Digital Blood Pressure Monitor Instruction Manual

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

Blood Pressure Monitor

Owner s Manual & Safety Instructions

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

LD7. Digital Blood Pressure Monitor Instruction Manual. Ciśnieniomierz elektroniczny automatyczny LD Instrukcja Obsługi ENG POL

Model MIT Elite Plus

Digital Automatic Blood Pressure Monitor

Check following components! Vérifier les composants suivants! Digital Automatic Blood Pressure Monitor Model M3 Instruction Manual

SpotArm Type Blood Pressure Monitor. Model i-q142

Omron Blood Pressure Monitor Need Manual Bp760 Automatic

705CP-II. Automatic Blood Pressure Monitor & Printer. Mode d emploi page 67 Istruzioni per l uso pagina 89

Digital Automatic Wrist Blood Pressure Monitor Model R6 Instruction Manual. English Français Deutsch Italiano Espanõl Nederlands Русский

boso Germany Do you? Premium quality essgeräte für die Selbstmessung I use equipment of BOSCH + SOHN to measure blood pressure.

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

Instruction Manual. S&S Tradings

INSTRUCTION MANUAL. OMRON IntelliSense Blood Pressure Monitor. ModelHEM-907

Blood Pressure Monitor B06T

Objectives: Assisting with Medication, Checking vital Signs

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

Aneroid Sphygmomanometer. Use, Care, & Maintenance

UA-851THW/UA-851TMW/UA-851THX Wireless Automatic Blood Pressure Monitor Users Manual

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

Declaration of Equivalence Form

Blood Pressure Monitor Instruction Manual

VIDEO TUTORIAL: greatergoods.com/0605

Transcription:

English Español Português Deutch INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-432B CH-432B POWER START Italiano Français - Eng 1 -

CLEANING METHOD OF CUFF After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air. Hard rubbing or washing in a washing machine will cause air leakage. Also, be careful not to get water into the air hose. GENERAL REMARKS General Remarks on blood pressure measurement If the cuff is to be deflated quickly, depress POWER switch. The attached cuff is suited for an arm circumstance of 22cm to 32cm. When attaching the cuff, rubber cuff hose should be placed on the inside of your arm on top of the arterial. Self measurement is no therapy! In no case may you change the dosage of medication prescribed by your physician. In operation for blood pressure measurement, you should urinate and should remain relatively still for 10 to 15 minutes prior to measurement. Exercise, eating and drinking, smoking, etc., prior to measurement may affect the results. The blood pressure varies constantly throughout the day. Measurement should be made regularly at the same time each day. Do NOT be impressed by the results of one measurement. Keep a record of blood pressure variations. Many readings tell a story. Emotional stress may tend to cause pressure to rise. This Product should not be used to monitor cardiac arrhythmia. Diastolic Blood Pressure mmhg 89 85 NORMAL HIGH NORMAL HYPERTENSION 130 139 mmhg Systolic Blood Pressure For proper measurement of blood pressure Take a deep breath five or six time and then relax before measuring blood pressure. If you are tense when taking the measurement, you will not get a valid reading. Blood pressure will be elevated when you are in a worrisome or irritated state, suffering from lack of sleep or constipation, or after exercise or a meal. - Eng 2 -

English Español Português Deutch Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the arm and tighten it so that one finger may be inserted between the cuff and arm. Do NOT measure blood pressure after bathing or drinking. When you feel like relieving yourself, you should do so before measuring blood pressure. Measure blood pressure where the room temperature is about 20 C. Do NOT measure blood pressure when it is too cold (below 10 C) or too hot (above 40 C) in the room. Do NOT measure blood pressure immediately after drinking coffee or tea or smoking. Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk during measurement. Do NOT keep on measuring so many times, as your arm will have built up congestion of blood, and you will not get a valid reading. PRECAUTION FOR USE AND MAINTENANCE Precautions for use If you suffer from heart disease, high blood pressure or other circulatory disease, please consult your doctor first. If you feel abnormal pressure of the cuff during use or any other irregularity, reduce the pressure by immediately switching off the power or removing the batteries and consult the sales outlet where purchased. If you think the measured value is abnormal or if measuring makes you feel unwell, discontinue use and consult your doctor. Measurement of blood pressure may not be possible for someone with a weak pulse or arrhythmia. Congestion, swelling, etc. may occur in some people. If blood pressure is measured repeatedly, an accurate result will not be achieved. An interval of about 10 minutes should be allowed. - Eng 3 - The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data. Precautions for maintenance Do NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60 C), low temperature (below 20 C), high relative humidity (over 95%) or in a dusty place. Do NOT expose the blood pressure monitor to under force or vibration, or drop it. Remove the battery/batteries when not in use for a long period. Do NOT disassemble the apparatus. Do NOT bend the cuff or air hose unnecessarily. NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it. Italiano Français

When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Nature and frequency of maintenance: This products is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Protect the nature environment: Please help protect natural environment by respecting national and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. Reference European standard: This products complies with EC instructions 93/42/EEC (Medical Device Directive) and with the following standards: EN 1060-1: 1995 Noninvasive Sphygmomanometers, Part 1 General Requirements and EN 1060-3: 1997 Noninvasive Sphygmo-manometers, Part 3 Supplementary Requirements for Electromechanical Blood-Pressure Measuring Systems. Manufacturer: Name: Premier Precision Ltd. Address: Block E, G-H, 6th floor, Phase 2, Yip Fat Factory Building, 73-75 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong European Representative: Name: WvW elektronische Geräte Vertrieb GmbH. Address: Robert-Koch-Straße 20, D-80538 München, GERMANY - Eng 4 -

English Español Português Deutch IDENTIFICATION OF PARTS Tube socket Systolic blood pressure display section Diastolic blood pressure/ Pulse display section CH-432B BT Cuff Cuff tube Air connector Battry cover POWER START Power/Start switch Italiano Français - Eng 5 -

MEASUREMENTS 1. Attaching of Arm Cuff and Posture During Measurement Wind the arm cuff around the left upper arm tightly so that bottom edge of the cuff is positioned about 1 2cm above the elbow joint. When you will wind the cuff, please wind the cuff next to the skin of possible. (If measurement is made by rolling the shirts or jacket up over the arm, this will constrict the upper arm and prevent accurate measurement.) Unfasten and open the cuff as shown in the figure. Cuff tube should be placed on the inside of your arm as figure. - Eng 6 - Please make sure that the cuff is fastened tightly. Note that uneven cuff winding will prevent proper measurements.

English Español Português Deutch 2. Carrying out the Measurement Rest the elbow on a table so that the section of the upper arm is at the height of the heart. Relax the lower arm across the table and remain still, since movement - artifacts may falsify the measuring result. Make measurements in either a seated or reclining posture with the palm turned upward. Press the POWER / START switch. Insert the air connector from the cuff into the tube socket at the mainframe until it is tightly connected. When the POWER / START switch is pressed, the lastmeasured systolic blood pressure and diastolic blood pressure are displayed for about 2 seconds. Italiano Français At the first measurement after battery replacement the mark of Q is displayed for about 2 seconds. - Eng 7 -

When the POWER / START switch pressing, the pressure level for measurement will change at optional level over 160 mmhg. But if the POWER / START switch is released before 160 mmhg, the pressure is heightened to 160mmHg. When the pressure lowers by 15mmHg after pressurization stops, the mark of Q is displayed. The pressure is automatically heightened to the level for measurement of the blood pressure based on the last-measured systolic blood pressure. At the first measurement after battery replacement the pressure is heightened to 160mmHg. If the level of the pressure is not enough, the pressure is automatically heightened to the level for measurement of the blood pressure again. If pulse is recognized, the pressure is shifted to the diastolic blood pressure indicating section and change over, synchronized with the pulse. - Eng 8 -

English Español Português Deutch When the measurement has been completed, the systolic blood pressure, the diastolic blood pressure and the pulse rate are alternately displayed and the air is discharged. The systolic blood pressure and the diastolic blood pressure are displayed for about 2 seconds and the pulse is displayed for about 1 second. The measured data are registered automatically, as long as they are not error. When a person with maximum blood pressure of 170 mmhg or higher uses the unit for the first time, or after changing batteries, measure blood pressure using the manual setting. If the automatic pressure setting is used, it may not work. - Eng 9 - Automatic Pressure Setting This product automatically sets the pressure based on the previous measurement, so you can easily measure blood pressure by pressing one button without resetting the pressure for each measurement. If several people use the unit, we recommend using the manual settings as follows. Manual Pressure Setting When several people use the unit, set the pressure value manually. Please note that if the manual pressure setting is not used, pressure will be automatically applied based on the value set by the previous user. If the previous user had a high pressure setting, that high pressure will automatically be used for the current user. If you feel pain in your arm, press the POWER / START switch immediately to turn of the power. 1. Put the arm cuff around your arm, plug the air hose into the unit, and keep your arm at the level of your heart. 2. Keep the POWER / START switch depressed until the pressure display shows the optimal pressure setting. (The optimal pressure setting is about 40 mmhg higher than your usual maximum blood pressure.) 3. When the pressure display reaches the optimal pressure value, release the POWER / START switch. When the POWER / START switch is released pressurization will finish and measurement will start. Manual pressure settings can be selected between 160 mmhg - 280 mmhg. If you release the POWER / START switch before reaching 160 mmhg, the unit will pressurize to 160 mmhg. If the unit senses that the pressure is not high enough, it will apply more pressure. Italiano Français

3. Turn Power OFF Press the POWER / START switch to turn off. Battery cover Remove the battery cover at mainframe and replace four type AA batteries. 4. Subsequent Measurement When a measurement is need again, 10 minutes, interval is necessary between measurements. 5. Automatic Power OFF Function If the unit is left without any operation after measurement, an Automatic Power-OFF Function runs to turn off the power after approximately 3 minutes. To continue measurement, press the POWER / START switch again. 6. Battery Replacement If the batteries are almost empty, the mark will be displayed. In this case, batteries should be replaced with new one. Batteries are almost empty. Batteries are normal. Note: The memory data are erased when you replace the batteries. The batteries that are included power the monitor. They may not last as long as indicated. If manganese batteries are used at a low room temperature, such as in the winter or for other reasons, the batteries may not function properly and you may not be able to measure your blood pressure. Please dispose of used batteries properly to protect the environmental. - Eng 10 -

English Español Português Deutch DESCRIPTION OF DISPLAY MARKS DISPLAY MARK CONDITION / CAUSE CORRECTIVE ACTION Displayed when the blood pressure could not be measured accurately. (Some noises were detected by the movement of arm during measurement.) Take off the cuff and wind it again, and carry out measurement once more. Do not move the arm during measurement. BT Displayed when the pulse rate could not be measured. Displayed when the batteries are almost empty. Take off the cuff and wind it again, and carry out measurement once more. Do not move the arm during measurement. Replace four batteries. Italiano Français The unit has a trouble. Take it to the store where it was purchased for testing. - Eng 11 -

SPECIFICATIONS Model No. CH-432B Measuring Principle Oscillometric Method Measurement Localization Left Upper Arm Cuff Soft Cuff Arm Circumference Range 22.0 to 32.0cm Measurement Range Pressure 0 to 280 mmhg Pulse 40 to 180 Pulse/min. Accuracy Pressure ±3 mmhg Pulse ±5% of Reading Systolic blood pressure: 3 Digits Pressure Diastolic blood pressure: 3 Digits Alternately LCD Indication Pulse Pulse rate: 3 Digits Marks Measuring Q Battery Empty LCD View Size 18(H) 61(W)mm Digit Size (Pressure) 14(H) 6.5(W)mm Switch POWER / START switch Inflation Automatic Inflation by Internal Pump Deflation Automatic Air-release Valve Exhaust Electromagnetic Valve Rated Voltage 6 VDC Power Source 4 AA Size Batteries Power Consumption 4W (Measuring) Battery Life Manganese Batteries Approx. 200 times Alkaline Batteries Approx. 700 times (160 mmhg, 1 time/day, 22 C) Automatic Power-Off Function Approx. 3 min. Memory Function 1 Memory Dimension 129(W) 121.5(D) 55(T) [mm] Weight Approx. 300g Operating Environment Temperature 10 to 40 C Humidity 30 to 85%RH Storage Environment Temperature 20 to 60 C Humidity 10 to 95%RH * Specifications and designs may be changed without notice in the event of improvements being made. - Eng 12 -

CITIZEN is a registered trademark of Citizen Watch Co., Japan. Consumer Electronics Division CBM Bldg. 5F, 5-68-10, Nakano, Nakano-ku, Tokyo 164-0001, Japan Phone: (03)5345-7430 Fax: (03)5345-7431 E-mail: info-con@jcbm.co.jp