OPERATION MANUAL MPV-623 AIR-FED VIZOR

Similar documents
OPERATION MANUAL MPV-627 AIR FED HALF MASK

(MPV-625) 8 AIR SUPPLIED RESPIRATOR

AIRFED 2100 Full Face Breathing Mask

Operation Manual Advanced-Conventional Pressure Feed Spraygun

SB-E ISS.01. Operation Manual: KB-522 & KB-522-SS Pressure Feed Cup E P ITW Finishing Systems and Products

Respiratory Protective Equipment

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

INSTRUCTION MANUAL. Doc. no. MN4007E Rev. B - Oct NOVA 1 Abrasive Blasting Helmet 0194 EN14594: Surface Treatment Solutions

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Astro Sandblast Helmet

ST53SD. Self Contained Breathing Apparatus. User Manual

EN14594: 2005 INSTRUCTION MANUAL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

Breathable Compressed Air

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Compressed Airline Breathing Apparatus

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Operation Manual: MODEL BBR PRESSURE/SIPHON FEED HAND GUN Important:

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

How to Make a Respirator Program and Calculating the Cost

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

Checklist for care of Respirators

Advantage 4000 Abrasi-Blast Respirator

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

LIGHTWEIGHT ABRASIVE BLASTING HELMET INSTRUCTION MANUAL

BREATHE SAFELY: The Proper Use of Respiratory Protection

A. Evaluation of the written program

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Operation Manual HVLP & Trans-Tech Suction Feed Spraygun

Head Cover BE-12 Series

PPE: RESPIRATORY PROTECTION EQUIPMENT

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

3M Personal Safety Division 3M Supplied Air Respirator System S200+ Work. in a World of. Comfort. The Power To Protect Your World

Niltox Breathing Air Purifier Range

Comfort. Work. in a world of NEW. 3M Occupational Health and Environmental Safety Group

Tsunami Breathable Air System

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Operate Breathing Apparatus

75 Years of Health and Safety Guidance

Respiratory Protection for Producers

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

PRODUCT NUMBER: A COMPACT AIR A150401

SB-E ISS.07. Operation Manual AGN-502 Automatic gun

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

Respiratory Protection. Program

Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS.

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

SR63 supplied air hood Copyright 2013 by The S.E.A. Group 1

PRESSURISED PAINT CONTAINER

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

TITAN II RESPIRATOR HELMET

Budget Range Operators Handbook

Important: Keep these instructions for reference.

SR307 supplied air regulator Copyright 2013 by The S.E.A. Group 1

Operating Manual. Model BAC-30RT30/BAC-30DC

PRODUCT OPERATING MANUAL

Respiratory Protective Equipment

INTENDED USE TECHNICAL SPECIFICATIONS

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Respiratory Protection Self Inspection Checklist

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

PRODUCT NUMBER: Rd40 Aluminium Canister HgP3

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

MINIATURA PAINT SPRAY HELMETS

Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1.

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

ASPECT INSTRUCTIONS Version 1.0

Safe Work Practices / Procedures / Instruction CONFINED SPACE

NIOSH CAUTIONS & LIMITATIONS 3 WARNINGS 4 INTRODUCTION 6 RESPIRATORY OPERATION 6 RESPIRATOR COMPONENT CONCEPT 8

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Respiratory Protection

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

RESPIRATORY PROTECTION PROCEDURE

PROMASK FULL FACE MASK

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Respiratory Protection

B-Series. breathing air systems flow capacity: scfm

OWNER S MANUAL. Page: 1 of 8

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

AUTOVENT 4000 VENTILATOR

Fire Escape Hood OPERATION AND INSTRUCTIONS

Supplied Air Respirators

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

HEAVY DUTY BELT SANDER. MODEL NO: CAT 70 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 0906

Respiratory Protection Program 29CFR

Vortex Tube Respirator

Transcription:

SB-EE-25-0481 Iss.04 OPERATION MANUAL MPV-623 AIR-FED VIZOR

2

E Operation Manual MPV-623 AIR-FED VIZOR Important Read and follow all instructions and Safety Precautions before using this equipment SAFETY WARNINGS IMPROPER USE IS DANGEROUS. READ INSTRUCTIONS BEFORE USING This supplied air respirator is designed to provide a high level of protection in contaminated atmospheres when worn and used correctly. It is not for use in atmospheres immediately dangerous to life or health and if accidentally disconnected or removed the wearer must be able to safely reach clean breathable air supply. The compressed air supply to the respirator must be of breathable quality and conform to BSEN 12021:1998 and relevant National or The MPV supplied air-fed vizor respirator is CE approved under PPE Directive 89/686/ EEC. The visor conforms to European Eye- Protection standard EN166, category F for low energy Impact and liquid splash protection. An MPV supplied air vizor system, correctly fitted and applied by trained personnel in accordance with these instructions, may be used subject to the user determining its suitability, for protection from particles, fumes, The MPV supplied air vizor has a lightweight fully adjustable headband. The neck and ears are also protected with a disposable cover. The vizor has a diffused compressed air feed tube. The vizor can be lifted up from the face when the operator is not working in a hazardous area. Two half turn tension knobs adjust the vizor movement. The vizor air feed tube is connected to its associated filter/regulator which is attached at the waistbelt. The preset compressed air pressure regulator maintains a constant flow APPROVAL FOR USE DESCRIPTION local Standards. THE ACTIVATED CARBON FILTER DOES NOT REMOVE CARBON MONOXIDE OR CARBON DIOXIDE. THIS DEVICE IS RECOMMENDED WHEN SPRAYING 2 PACK PAINTS AND PAINTS CONTAINING ISOCYANATES. ITW Finishing Systems and Products reserve the right to modify equipment specification without prior notice. gases and vapours. The respirator should only be used with Devilbiss original components to maintain approval for the system, this includes the compressed air supply hose item 18 (fig1) and hose connectors. INSPEC International Ltd CE approval (Notified body number 0194) 56 Leslie Hough Way, Salford, M6 6AJ, England,United Kingdom. of air to the vizor. Manufacturers minimum design flow rate 140 litres/min (4.9 Ft³/min). The disposable activated carbon filter removes odour, oil and vapour. A short hose with connections is supplied for the attachment of a spray gun to the connection provided see fig 1. Two disposable vizor covers and a disposable hood for additional skin protection when used with materials containing chemicals that have harmful effects, are also provided, i.e when spraying 2 pack paints. 3

SUITABILITY FOR USE It is the duty of the employer to determine such suitability and in so doing the following factors should be considered bearing in mind that the circumstances of use determine the level of protection provided. 1) The respirator must not be used in atmospheres immediately dangerous to life or health; i.e those atmospheres from which it would not be possible to escape without risk to life or health. Such atmospheres include those deficient in oxygen. 2) The respirator must not be used in atmosphere where the concentration of contaminant may exceed the allowable exposure limit and it should be noted that at exceptionally high levels of physical work the peak inhalation may exceed the constant flow of supplied air. (See Specification) 3) The wearer must be able to adjust and fit the respirator correctly. The wearer must be trained in the correct wearing and operation of the respirator and understand the limitations of use. 4) The employer should ensure that the respirator, which is intended for light duty service, is suitable and that the appropriate model is selected and that the trailing supply hose will not present a hazard to the wearer or others in the vicinity. Refer to - HSG 53. The selection use and maintenance of respiratory protective equipment (HSE Guide). 5) The employer must provide a suitable management system, to ensure that the respirator is maintained in accordance with the manufacturers instructions. Refer to - BS4275: 1997 Guide to implementing an effective respiratory protective device programme. SPECIFICATION Protection- Assigned Protection Factor APF=40 Carbon Filter Life = 1000 HRS. NOTE CARBON FILTER HAS A LIMITED SHELF LIFE. Supply pressure - 3.8 bar (55 lbf/in²) At hose supply connection (See Fig 1) max 7 bar (100 lbf/in²). Supply hose - Only to be used with Devilbiss original hose. The manufacturers flow rate is recommended at a minimum of 140 litres/min (4.9 SCFM) to the mask. See parts list for recommended supply hose. The MPV-623 Air Fed Vizor Outfit, comprises of: MPV-526: Vizor Assembly with ratchet headband, detachable vizor covers neck cover, disposable hood, stowage bag, 2 face cassettes and a hose to connect to MPV-518 waistbelt assembly. MPV-518: Waistbelt Assembly: An adjustable nylon belt with quick fit buckle. Disposable carbon odour removal filter and pre-set regulator in a moulded housing which is moveable on the belt. MPV-456 Rubber air hose (1.2 M) with quick detachable fittings to connect spray gun. 4

INSTALLATION / OPERATION WARNING: NEVER USE THIS RESPIRATOR IN AN AREA WHERE THE ATMOSPHERE IS IMMEDIATELY HAZARDOUS TO LIFE OR HEALTH. IN AN EMERGENCY THE WEARER MUST BE ABLE TO ESCAPE FROM NOTE: THE WORK AREA WITHOUT THE NEED OF A RESPIRATOR. THE AIR SUPPLIED MUST BE OF BREATHABLE QUALITY AND CONFORM TO BSEN 12021:1999 AND THE RELEVANT NATIONAL AND LOCAL STANDARDS. ONLY USE RECOMMENDED DEVILBISS SUPPLY HOSE CAUTION: It is essential to site the air intake of the compressor so that the air intake is free from contaminants. The compressed air must be regularly checked for breathable quality. As a precaution against a supply failure or pressure loss an audible low pressure warning device should be fitted as described under accessories. It is recommended that a new air supply hose item (18) fig1 is used and specially identified for breathing air. In the interest of hygiene each user should have their own face mask and hood. HOSE LENGTH: Note 10m is the maximum hose length that can be used due to the minimum pressure requirements. If longer hose length is required a portable coalescing air filter device must be located at the supply end of the10m hose and be capable of supply pressure of 3.8 Bar (55 lbf/in²) at this point. DONNING PRODEDURE WARNING: DO NOT ENTER THE CONTAMINATED AREA UNTIL ITEM (10) IS COMPLETED 1) Connect the air supply hose to the outlet of a coalescing air filter such as a DVFR 2. Do not turn on the air supply. NOTE: Ensure that the supply hose is of sufficient length to allow the operator to enter and leave the contaminated area without disconnecting or removing the vizor. 2) Check the waistbelt and respirator assemblies ensuring that all parts are in good condition. Replace if damaged. 3) Attach and adjust the waistbelt assembly ensuring that the supply air inlet and spray gun outlet connectors are pointing down. 4) Connect the air supply hose to the waistbelt inlet. 5) Connect the respirator feed tube to the outlet socket on top of the filter assembly. 6) Connect the spray gun air supply hose to QD outlet on the bottom of the filter assembly (if required). 7) Place the vizor assembly on the head and, with the vizor in the open position, adjust the tension knobs. Ensure that the feed tube is not twisted or kinked and will not interfere with normal movements. 8) Turn on the air supply and check that the air is flowing freely to the inside of the vizor. 9) Adjust the air pressure with the gun (if fitted) triggered to ensure that the minimum supply pressure at the inlet of supply hose is in accordance with the minimum requirements 3.8 bar (55 psi). 10) Before entering the contaminated area, the vizor must be pulled down, so that the material face seal is located under the chin and in contact around its entire periphery, the tension knobs are adjusted so that the vizor is locked in this position. NOTE: Do not lift or remove the vizor inside the contaminated area. Retreat from the area immediately if any malfunction is suspected or if the warning whistle sounds (if accessory fitted). 5

REPLACEMENT OF PARTS DISPOSABLE CARBON FILTER (14): 1) Unscrew the three cross head screws holding the regulator (13) to the filter housing (15). 2) Remove the spent filter (14) from the filter housing (15) and replace with a complete new moulded filter cartridge (14) 3) Replace the regulator housing and retighten the securing screws. 4) Connect to the air supply and ensure correct airflow to the mask before use. INSPECTION: 1) Replace carbon filter see specification for life or sooner if odours are not effectively removed. NOTE CARBON FILTER HAS A LIMITED SHELF LIFE. 2) Check security of the hose connections and that hoses and tubes are in good condition. Replace if damaged. MAINTENANCE 3) Visually check the condition and function of all components of the vizor particularly the face seals, head harness. Replace if damaged. 4) Check air supply quality on a regular basis see installation/operation. 1) Regularly clean and/or disinfect the face mask and headband assemblies. DO NOT USE PAINT SOLVENTS Recommended solutions:- a) Cleaning: 3ml of liquid detergent to 1 litre of warm water, mix thoroughly. b) Disinfectant: 2 ml of Dettol to 1 litre of warm water, mix thoroughly. CLEANING Method for cleaning and/or disinfecting: Use a lint free cloth dampened with the solution and wipe outside and inside of the face mask and headband assemblies. Repeat with a clean lint free cloth dampened with clean luke warm water. Allow to dry naturally, maximum ambient temperature 40 C. ACCESSORIES MPV-525: Breathsafe air quality test kit - tests air flow and quality after the waistbelt filter/ regulator for carbon monoxide, carbon dioxide,oil mist and water carry-over. DVFR-2 Filter, regulator and coalescer. Suitable for 2 operators, this unit provides air filtered to 99.99% at 0.01 micron. DVCF-1 Filter and coalescer. Suitable for 2 operators, this unit provides air filtered to 99.99% at 0.01 micron. MPV-405: Low pressure Warning device provides an audible whistle to warn the operator when the air pressure is insufficient to supply the minimum recommended air flow. Permanently fit to the filter/regulator assembly, remove (16), screw whistle device in place then re-fit connection (16) to whistle inlet. 6

Note Kit quantities do not apply to outfits, see quantities specified in outfit column. * NOT PART OF OUTFIT ORDER SEPARATELY Use of this Devilbiss supply hose is essential to ensure correct and safe operation of this equipment. NO DESCRIPTION PART NO QTY MPV- 623 OUTFIT QTY MPV- 526 OUTFIT NO DESCRIPTION PART NO QTY MPV- 623 OUTFIT QTY MPV- 526 OUTFIT 1 VIZOR ASSEMBLY (REF NOS 2-10) MPV-526 1 2 QUICK DETACHABLE STEM MPV-20 1 1 3 CLEAR VIZOR (KIT OF 5) MPV-478-K5 1 1 4 VIZOR COVERS (KIT OF 10) MPV-44-K10 2 2 5 FACE CARTRIDGE FOAM (KIT OF 5) MPV-476-K5 1 1 6 FACE CARTRIDGE TYVEK (KIT OF 5) MPV-477-K5 1 1 7 NECK COVERS (KIT OF 5) MPV-24-K5 1 1 8 HOODS (KIT OF 5) MPV-2-K5 1 1 9 STOWAGE BAG MPV-458 1 1 10 TUBE AND DIFFUSER ASSY MPV 457 1 1 11 WAISTBELT ASSEMBLY MPV-518 1 12 QUICK DETACHABLE CONNECTOR MPV-442 1 13 REGULATOR AND HOUSING MPV-455 1 14 DISPOSABLE FILTER MPV-22 1 15 WAISTBELT AND FILTER HOUSING MPV-519 16 QUICK DETACHABLE STEM MPV-10 1 17 QUICK DETACHABLE CONNECTOR MPV-424 1 18 SUPPLY AIR HOSE 5/16 BORE 18a -10M LG M-F QD FITTINGS H-6085-QD 18b -10M LG 1/4 RE-USABLE FITTINGS H-6065-B-R 19 GUN HOSE ASSEMBLY MPV-456 1 20 QUICK DETACHABLE STEM MPV-5 1 * 7

ITW Finishing Systems and Products reserve the right to modify equipment specification without prior notice. ITW Finishing Systems and Products Ringwood Road, Bournemouth, BH11 9LH, England. Tel. No. (01202) 571111 Telefax No. (01202) 581940, Website address http://www.devilbisseu.com http://www.itwifeuro.com. ITW Finishing Systems and Products is a Division of ITW Ltd. Reg. Office: Admiral House, St Leonard s Road, Windsor, Berkshire, SL4 3BL, UK Registered in England: No 559693 Vat No 619 5461 24 8 October 09