EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

Similar documents
EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

DPC-30 DPC-100. Reference Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

MODEL 100 NITROGEN INFLATION CART

M104 Series: Digital Manometer: 0.1 % of Full Scale

G7S Hand Pump Owner s Manual

4-in-1 Professional Inflator Kit

CSA Sample Draw Aspirator Adapter Operator s Manual

6 digital caliper with case

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL RLD10

User Instruction Manual

ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

GasLab SAN-102 Micro Oxygen Monitor User Manual

92831 TEL: (714) FAX:

PC1131 Electric Air Compressor

GasLab SAN-102 Micro Oxygen Monitor User Manual

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

OWNER S MANUAL. AXD 530 MicroManometer

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

J Air and Water Kit Instructions Part# 02584

INSTRUCTIONS warranty watch care

Golf Performance Monitors. PureContact Operating Guide. Version of 9

Installation & Instruction Manual For Portable Series R.O. units:

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

D Series Air and Water Kit Part# 02550

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

RAM 4021 Operation Manual

SP-110 Autopilot OPERATION

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Digital Vacuum Regulator

PS-425 Pitot-Static/Air Data Tester

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Advanced Test Equipment Rentals ATEC (2832)

PM105 PRESSURE METER USER S MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

LSA-BAWMBL. Wall-Mounted Boom Arm INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Owner s Manual Humiport 10/20

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Robic M-477 Instructions and Operating Guide

RK LEL Sample Draw Aspirator Adapter Operator s Manual

92831 TEL: (714) FAX:

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Pressure Injection Cell Operator s Manual

Gas Countertop Hot Plates

Sunset Swings By Health in Motion, LLC

MODEL CALIBRATION GAS DELIVERY SYSTEM

Standard Gas Countertop Griddle

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Model ASSEMBLY and OPERATING INSTRUCTIONS

ASDX Series Silicon Pressure Sensors

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

TactAir PCP Fill Kit/Adapter. Operation Manual

Digital Vacuum Regulator

Agilent Flowmeter ADM1000

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

LM6 LEATHER MOISTURE METER

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

SERIES L4E & L6E LADDER EXTENSIONS

Installation Instructions JATCO Environmental Protection Tank Model J-7000

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

2 Gallon Air Compressor

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Nitrogen Supply System

Operation Manual. O2 Quickstick. Oxygen Analyzer

200 PSI FAST-FILL AIR SOURCE KIT

Foldable Magne c Exercise Bike

PRODUCT CATALOGUE WHATEVER YOU RIDE WHATEVER YOU DRIVE...

SERIES BA TRASH BASKETS

Prestan professional Training manikin

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

NOTES TABLE OF CONTENTS

Modular skylight warranty

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Please Do Not Return This Product To The Store!

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Introduction INDEX. INTRODUCTION HSE

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

MODEL NUMBER: P PORTABLE COMPRESSOR

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. C

Getting to know your Sureshotgps micro V3

WARRANTY, QUICK START GUIDE

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Research Grade Blood Pressure Transducer User's Manual

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PARK AVENUE 7' POOL TABLE WITH TABLE TENNIS & BENCHES ASSEMBLY INSTRUCTIONS

Owner s. product. Failure injury

12V AIR STATION ALL-IN-ONE

Transcription:

EM151/EM201 Electronic Manometer INSTRUCTION MANUAL - + PSI EM201 www.ueitest.com Email: info@ueitest.com

TABLE OF CONTENTS Safety Rules..............................................2 Features.................................................3 Operating Instructions.......................................4 EM151/EM201 Specifications.................................6 Pressure Conversion Chart....................................7 Warranty................................................8 INTRODUCTION The EM151 and EM201 provide a simple, timesaving alternative to U-tube pressure measurements. Use the UEi EM151 & EM201 to measure gas supply and draft pressures in residential or light commercial properties. The EM201 differential mode provides a convenient method to measure pressure drops.

SAFETY RULES WARNING! Before every use, check to be sure the meter and its tubing are free from breaks or blockage. While using the meter, if you suspect gas is leaking, or if you can smell gas, close off the gas supply and ventilate the occupied space. Identify and repair the source of the leak before continuing with the test. In the interest of safety, this instrument should only be used by trained, competent professionals who know the hazards and consider the risks of working on and with industrial equipment. These meters do not measure water pressures; under these conditions they will fail. Do not exceed 10 PSI input pressure 2

FEATURES EM151 Single input to measure positive and negative pressure to ±20" wg Ruggedized, including rubber boot with integral magnet Simple two-button operation Measures in inches water gauge Auto power-off after 20 minutes 1 year limited warranty EM201 Dual input differential measurement to ±40" wg or ±100 mbar Ruggedized, including rubber boot with integral magnet Measures in inches water gauge and mbar Auto power-off after 20 minutes Min/Max value capture Data Hold Back-lit display 1 year limited warranty 3

OPERATING INSTRUCTIONS 1. Zero the meter Prior to use, the meter must be zeroed. To do this, ensure the meter is in a non-pressurized area, and press and hold the ZERO button for approximately four seconds. The display will show 888 to indicate that the zero function has occurred. 2. Measure Pressure Connect the flexible tube between the meter and the pressure source. The EM201 s positive input is to the right when looking at the front of the instrument. Applying a positive pressure to this port will display a positive reading. The input to the left is the negative port. (Applying a positive pressure here will display a positive reading). Use either input to measure a single source by venting the unused input to atmosphere. The instrument will continually provide a differential reading of the two inputs. 4

3. SCALE To select mbar press the "SCALE" button on the EM201. Press "Scale" again to return to inches of water gauge. To select scale on the EM151briefly press the green button. 4. MIN/MAX (EM201 Only) The EM201 will capture values for both the minimum and maximum values read. To reset zero the instrument or simply power the meter off, then back on. Captured values can be displayed in either inches water gauge or mbar. 5. HOLD (EM201 only) The EM201 has a display hold feature. Press this during reading to freeze the display. Press again to return to actual measurement. 6. BACKLIGHT (EM201 only) The EM201 has a backlit display. Press back light feature. to turn on or off the 7. Over-range If the input exceeds the meter range "OL" will be displayed. Immediately disconnect from the pressure supply safely to reduce chances of damage to the instrument. 5

EM151 SPECIFICATIONS Measurement range: -20" to +20" WG Minimum pressure displayed: 0.01 WG Accuracy: ±0.02 < 2 ±1%rdg > 2 Resolution: 0.01" -9.99" to +9.99" WG 0.1" < -10", > +10" wg Operating range: 0-40 C, 10-90% RH non condensing Battery life: 50 hours min with alkaline battery EM201 Measurement range: Minimum pressure displayed: Accuracy: Resolution: Operating range: Battery life: 6-40 to +40" WG 0.01 WG ±0.02 < 2 WG ±1%rdg > 2 WG 0.001" -9.999" to +9.999"WG 0.01" < -10", > +10" wg 0-40 C, 10-90% RH non condensing 40 hours min with alkaline battery

PRESSURE CONVERSIONS Multiply By To Get In. of H2O 1.868 mmhg In. of H2O 0.074 in HG In. of H2O 0.249 kpa In. of H2O 249.1 Pascals In. of H2O 2.491 mbar In. of H2O 0.036 PSI In. of H2O 25.40 mmh2o 7

WARRANTY The EM151 or EM201 are warranted to be free from defects in materials and workmanship for a period of three years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warranty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge. Return the unit postage paid and insured to: UEi Service Department 8030 SW Nimbus, Beaverton, OR 97008 (503) 644-8723 FAX: (503) 643-6322 Email: info@ueitest.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. 8

Call our UEi sales office to receive a FREE catalog of our complete line of diagnostic equipment. (503) 644-8723 Visit our web site: www.ueitest.com and email: info@ueitest.com www.ueitest.com Email: info@ueitest.com In Canada call: (604) 278-4511 FAX (905) 238-6760 Copyright 2009 Universal Enterprises, Inc. Printed in Taiwan EM151/201-MAN 1/09