CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

Similar documents
CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

CALIBRATION CERTIFICATE # 500

Metering Code Gas TSO, measurement by connected party Effective from to the present

LM LUMEN MAINTENANCE TEST REPORT

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

GMC-I Service GmbH Calibration Center

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Distribution of fishing intensity of pulseand beam trawling in the North Sea. Marcel Machiels. IMARES rapport C146A/15

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

SmartCal. SmartCal Troubleshooting Checklist

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

Recalibration of gas meters

Transferpette -8/-12

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

Recommended Practices for Calibration Laboratories

DeFelsko PosiTector CMM IS Probe

2014 Programme of Training Courses in Measurement & Calibration

Routine Testing. SOP Temperature Calibration of Halogen Moisture Analyzer. Applicable for HR / HG / HB / MJ Moisture Analyzers

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report

Test Report #: Date: June 21, 2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

User-Calibration of Mettler AT200 Analytical Balance

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

tradition. knowledge. responsibility. CALIBRATION OF ELECTRICAL MEASUREMENT EQUIPMENT CALIBRATION LABORATORY

CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG

Portable Gas Analyzers

Procedia Engineering Procedia Engineering 2 (2010)

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Installation Procedure Esco Miri Multi-Room Incubator

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

CORESTA RECOMMENDED METHOD N 6

VITLAB micropipette. Standard Operating Procedure (SOP)

General Accreditation Guidance. User checks and maintenance of laboratory balances

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

The above item, as tested, is considered to comply with the above specifications. PAGE 1 OF 6

technical guide Laboratory Balances Calibration Requirements

Service Calibration are you doing it properly?

Tradinco Academy Courses Program

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

ANSI/TIA-568-C : Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009

tr-- CALIBRATION CERTIFICATE Calibration Laboratory of Schmid & Partner Engineering AG Zeughausstrasse 43, 8004 Zurich, Switzerland DSGHzV2 - SN:1006

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

PRODUCT CONFORMITY CERTIFICATE

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Test Report Number: CRT-095 Project Number:

Maximum precision for quantifiable success.

Balancing and Settlement Code. Code of Practice Four

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

New ANSI Fall Protection Standards

Calibration Procedure

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z CALIBRATION

Speciality Gases Practice 4. Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel.

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Pneumatic high-pressure controller Model CPC7000

CALIBRATION AND ADJUSTMENT

Calibration Summary of Test Report No.: Sample

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

ali-q TM Gravimetric Verification Procedure

SKSTEX36(SQA Unit Code-H7C9 04) Calibrate textile production equipment

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

How to evaluate pressure measurement specifications

Pressure is our Business

Low-Level Mercury Monitoring

Certificate of Accreditation

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

EN ISO/IEC Technical Requirements

Standard Operating Procedure Measuring & Testing Equipment

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

Breath Alcohol Calibration Test No Summary Report

The World Of Weather Data

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Technical Procedure for General Laboratory Equipment

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

MET-101 Introduction to Metrology

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

Transcription:

CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8 5-5 - Customer Name City Site Number C&C PARTNERS TELECOM SP. Z.O.O. LESZNO 75 Order Number RMA Number 666 Environmental Conditions Temperature within Humidity within (. ±.) C (5 ± ) %rh Calibration Procedure Excel Certificate and traceability procedure (.) Results The instrument meets its specifications at all points measured. The results of the measurements are shown on page through 5 Date of Calibration Oct 6 Issue date: Oct 6 Date of Recalibration Oct 7 Place of Calibration Tested by Son W.H.J. van Hulten G.J.J. Sprik Head of laboratory This calibration is performed by a DEKRA certified lab for ISO 9:8. All measurements are traceable to national and/or international standards or have been derived by approved ratio techniques. When possible standards used for this calibration are ISO/IEC 75:5 accredited calibrated. This certificate may not be reproduced other than in full. Calibration certificates without signature are not valid. Fluke Nederland B.V. Science Park Eindhoven 58, 569 EC Son Tel: + () 675 E-mail: servicedesk@fluke.com Page: of 5

Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Remarks - The data type found in this certificate on the top of each page must be interpreted as: As-Found As-Left Found-Left : Calibration data collected before the unit is adjusted and / or repaired : Calibration data collected after the unit has been adjusted and / or repaired : Calibration data collected without any adjustment and / or repair performed - If the unit under test is used under rough conditions we recommend to decrease the calibration interval period, the calibration interval (due date) is the responsibility of the end user; - According to the European norm 'Operation of electrical installations' NEN-EN 5- release 5 and the Dutch norm NEN release 5 paragraph 5.. through 5..6, is a safety test not required. Therefore not performed. Standards and test-equipment used for this calibration: Model Serial No Inventory No Due to Certificate No DTX ARTIFACT SET N.A. WP 5 Aug 7 78 FTE895 575 WP68 6 Sep 7 585 Date of Calibration: Oct 6 Page: of 5

Main DTX-8 5 Test Date 6 Remote DTX-8R 5 Test Pgm UluTest v.. -Jun- Main Insertion Loss FEXT/IL Artifact SN 86668.5.5.5 5 6 7 8 9 Pass Worst margin:.56 at.75 MHz in pair. Worst accuracy at each frequency shown. Main FEXT FEXT/IL Artifact ID 86668 5 6 7 8 9 Pass Worst margin:.777 at 6.5 MHz in pair 78-6. Worst accuracy at each frequency shown. Main NEXT NEXT Ver Artifact ID 8676 5 6 7 8 9 Pass Worst margin:.68 at 97.5 MHz in pair -5. Worst accuracy at each frequency shown. Measurement accuracy requirement for nominally compliant Level IV field testers. Measured difference of DTX and reference laboratory equipment added to measurement accuracy of reference laboratory equipment. Worst accuracy at each frequency shown. Estimated accuracy of reference laboratory equipment. 6 : PM Page of 5

Main DTX-8 5 Test Date 6 Remote DTX-8R 5 Main Return Loss RL Ver Artifact ID 8666.5.5.5.5 5 6 7 8 9 Pass Worst margin:.75 at 6 MHz in pair 6. Worst accuracy at each frequency shown. Remote NEXT NEXT Ver Artifact ID 8676 5 Data not available 5 6 7 8 9 Pass Worst margin:.675 at 7 MHz in pair 6-5. Worst accuracy at each frequency shown. Remote Return Loss RL Ver Artifact ID 8666.5.5.5.5 5 6 7 8 9 Pass Worst margin:.76 at 6 MHz in pair 6. Worst accuracy at each frequency shown. Measurement accuracy requirement for nominally compliant Level IV field testers. Measured difference of DTX and reference laboratory equipment added to measurement accuracy of reference laboratory equipment. Worst accuracy at each frequency shown. Estimated accuracy of reference laboratory equipment. 6 : PM Page of 5

Main DTX-8 5 Test Date 6 Remote DTX-8R 5 Propagation Delay Cable Artifact Sn 575 Standard Meas Deviation Allow Dev Units Result Pair 7. 7.8 -.7. ns Pass Pair 6 68. 66.6 -.9. ns Pass Pair 5 6. 59.57 -.. ns Pass Pair 78 58. 57.95 -.5. ns Pass Report version..59 6 : PM Page 5 of 5