Critical Systems Inc. Work Instruction Template. Doc Number: CSI Delatech 6/12 Month PM-003 WORK INSTRUCTION

Similar documents
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Customer Support Troublshooting

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION AND SERVICE MANUAL FOR LANCER DISPENSING TOWERS

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

O&M Receiving and Inspection. Storage of Water Treatment Media

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

! WARNING. Before using this product read and understand instructions.

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

HIGH RATE BASKET STRAINER

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Installation of Your SprayMaster System

SEP 100 D.E. SEPARATION TANK

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Halsey Taylor Owners Manual STOP!

BLS 1900 Optimum REVERSE OSMOSIS SYSTEM

INSTALLATION INSTRUCTIONS FOR FUME SCRUBBERS

The Pool Shoppe Rymal Road East Opening Procedures for Aboveground Swimming Pools

UltRo Dual Flow Reverse Osmosis Water System

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Product Bulletin No.: D99-RRV2015-PIB-001

Vessel Installation and Operating Manual

NGP-250/500 Nitrogen Generator Quick Start Guide

Air Tractor Preventative Maintenance Manual And Troubleshooting

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

ST1600 SAND FILTER PUMP

Installation Troubleshooting Maintenance Instructions Installation / Start-up

SM/SMBW 2000 Series Filter Operating Manual

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

1020 Industrial Drive, Orlinda, TN fax

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Air Intake Snorkel Kit

In addition to this SOP, the policies and procedures of each operating company will be strictly observed by Rockwater personnel.

! WARNING. Before using this product read and understand instructions.

Installation and Operating Manual

Eaton Filtration, LLC

OPERATION MANUAL NTF-60 Plus

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

FRYSAFE COOKING OIL FILTRATION I&O MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

2.5 & 5.0 GALLON PRESSURE TANKS

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

Fisher DVI Desuperheater Venturi Inline

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet

Reverse Osmosis System Installation Guide and Operation Manual.

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Quad D.E. D.E. Cartridge Style Filter

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Cristal -Flo II Filter OwnerÕs Manual

LIBERTY and PATRIOT SAND FILTER SERIES INSTALLATION & OPERATION MANUAL. RX Clear Patriot Sand Filters

Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B

Pool Information 2015

170-SJ Feed UnitTM 470-SJ Feed UnitTM

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

INSTALLATION GUIDELINES

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

BS Series Basket Strainer

User Manual for the Mars Calibration Bench

Halsey Taylor Owners Manual

INSTALLATION GUIDELINES

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

OPERATION MANUAL NTF-15

Duplex Commercial Softeners

FAULT CODE TROUBLESHOOTING INDEX

Owner s Manual W Automatic Aboveground Pool Cleaner

Swimming Pool IAQUALINK WEB CONNECT

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Installation Instructions

III. Identify the initial installation requirements for standpipe systems

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

OPERATION MANUAL BFX-2

Bermad Model:

Adjustable. Unloader Valve. O&M Manual. Part #

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

SERVICE MANUAL. UDS / UDH Series Ultra Low NOx Direct Vent Water Heaters. Troubleshooting Guide and Instructions for Service

Purifier for Vinyl Lined Pools

Installation, Operation, and Maintenance Manual

OPERATOR S MANUAL & PARTS LIST

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

ANSUL IN-LINE BALANCED PRESSURE PROPORTIONER MANUAL

Transcription:

Pg. 1 of 5 WORK INSTRUCTION APPROVALS All approvals are maintained and controlled in the [Document Control System] system. Please refer to the [Document Control System] system for the current controlled revision and approval records. REVISION HISTORY AUTHOR REVISED SECTION/PARAGRAPH REV RELEASED Rex Gustafson] Initial Release, [A] 11/2/2012

Table of Contents Pg. 2 of 5 1. PURPOSE... 3 2. SCOPE... 3 3. DEFINITIONS... 3 4. RESPONSIBILITIES... 3 5. WORK INSTRUCTION... 3

Pg. 3 of 5 1. PURPOSE This document describes the requirements for performing a 6-month PM on Delatech 858/859 recirc. and non-recirc. CDO scrubbers. 2. SCOPE This procedure contains the required steps for cleaning and inspecting components critical to the operation of Delatech 858/859 recirc. and non-recirc. CDO scrubbers. 3. DEFINITIONS PM Preventative Maintenance CDO Controlled Decomposition/Oxidation 4. RESPONSIBILITIES Todd Erickson Approver Rex Gustafson Author 5. WORK INSTRUCTION 5.1 Shut down the CDO and allow to cool prior to performing preventative maintenance per the CDO shutdown procedure in section 7 of the CDO service manual. 5.2 Transition Section To remove, disconnect all water lines, drain pipe, conductivity sensor and the two 4 Tri-clamps from the section. Inlet Flange Conductivity Sensor (behind) 4 Tri-clamps Water lines Drain pipe Inspect all o-rings and gaskets. Thoroughly clean the inside of the transition section and inspect the coating (inside only). Inspect the spray nozzle and verify that water flow is not restricted. Looking up into the heater (through inlet flange) inspect the wall of the heater liner for buildup. You may need to remove the inlet flange. If buildup is found, remove liner and clean.

Pg. 4 of 5 5.3 Upper and Lower Scrubbing Sections Disconnect water and air lines from upper and lower flange assemblies. Remove clamps and flange assemblies from scrubbing sections. Inspect flange o-rings and spray nozzles. Verify water flow through nozzle is not restricted. Band clamp Flange assys w/clamps 4 clamp Water lines Remove 4 clamp and band clamp and remove upper and lower scrubber sections. Remove baskets and scrubber balls from scrubber sections Clean scrubber balls by rinsing with clean water. Inspect the coating on the baskets and the insides of the scrubber sections and inspect all o-rings and gaskets. Coated scrubber basket w/scrubber balls

Pg. 5 of 5 5.4 Inspect heater wires and rubber boots. Verify they are not brittle or corroded and terminal crimp is in good condition. 5.5 If PM is being performed on a non-recirc. scrubber, reassemble and return to normal operation. The PM for recirc. units continues below. 5.6 Recirculation and Sump Tank Plumbing. Remove plexiglas panels from front and right side of scrubber and inspect all plumbing and pumps for leaks or any signs of leaks (i.e. water stains). Remove cap from Y-strainer and clean and inspect filter. Verify it is free of cracks or holes. Y-Strainer Remove tank cover and drain/pump water from the tanks on the left side of the scrubber. Remove all remaining sediment from the bottom of the tanks. This will help keep the nozzles free of debris and clogging. Refill the front two tanks with water prior to restarting the scrubber 5.7 Reassemble scrubber and return to normal operation.