Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω

Similar documents
Grove - Gas Sensor(MQ9)

12/07/2016 Grove Gas Sensor(O₂) Wiki

Grove - Gas Sensor (O2)

Electrochemical Sensor

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

HTD series digital differential pressure sensors

ME3-HCL Electrochemical sensor

Electrochemical Sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

PHPS-7500 OEM Ceramic Pressure Transducer

PHPS-7500 OEM Ceramic Pressure Transducer

Transmitter CS 21 Operation Manual

GasSense NDIR User Manual

Gas Data Acquisition using Arduino

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

AMS 2710 PCB pressure sensor module with V output

Written Report of Robot Design

Transmitter CS 21 Operation Manual

MD61 Thermal Conductor Gas Sensor

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HPSD 3000 Pressure Transducer

RG2 Gripper Datasheet Version 1.6

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

AMS 6916 Board mount pressure sensor with ratiometric analog output

FTC130 Transmitter. Operating Manual

Operation manual Oxygen sensor

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Variable Area Flow Meters

HumiSys HF High Flow RH Generator

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

GENERAL INFORMATION FOR TGS SENSORS. Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors

IRceL Operating Instructions

MATC EXPERIMENT 27 MAXIMUM POWER TRANSFER

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Datasheet: K-30 ASCII Sensor

Nemoto Sensor Engineering Company Ltd

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

an ISO9001/14001 company

Nemoto Sensor Engineering Company Ltd

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

AUTO PUMP STATUS CENTER

Instruction and Maintenance Manual

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

COSMO INSTRUMENTS CO., LTD.

PRELIMINARY DATASHEET

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

MODEL GT820 OXYGEN SENSOR

Digital Flow Switch. Series PFM7

Technical Data Sheet MF010-O-LC

The Development of A System for Measuring the Level of LP Gas in the Home

Preparation for Salinity Control ME 121

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ASDX Series Silicon Pressure Sensors

O3 3E 1 F Gas Sensor Module

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

OC508 Programmable mv Calibrator

SENSORS Pressure CALDARO

SX -X Concentration transmitter for flammable/ toxic gases Zone 1 ATEX (Cat. 2) Ex d IIB+H2 T6 Gb Ex tb IIIC T85 C Db IP6X

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

MPM426W/436W Submersible Level Transmitter

CO2 incubator with additional process controls

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

xtreme DB Innovation Every Day Murrelektronik is your system partner: PIN ASSIGNMENTS INPUT OUTPUT AT A GLANCE

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Sensoric 4-20 ma Transmitter Board Operation Manual

MANUAL KPS Pressure Control Valve

SPD Pressure Sensor Families

Instruction and Maintenance Manual

Fixed Ozone Monitor User Manual December, Automatikprodukter

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

BS12N Piezoresistive OEM Pressure Sensor

Combustible Detectors Manual for Standard and de Luxe

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

TTL Flash Interface connections

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

MS52XX-C&T SMD Pressure Sensor

Gas Concentration Analysis with Curve Fitting Neural Network for Electronic Nose

Model 601CV. Mass Flow Controller. Product Features:

NEW: CO2 incubator with sterilizable sensor

Gas Mass Flow Meter SUS/SUS316

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

Mass Flow Controller (MFC) for Gases

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

living with the lab control of salinity 2012 David Hall

Mass Flow Controller (MFC) for Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Operating Two-Wire FH71-STANDARD & STANDARD SENSITIVE Preamp. to S600 FloBoss. +Vs = 24VDC Power Supply. (**) Protection fuse 100mA.

Technical Data. Dimensions

Coriolis Mass Flow Meter

ISM-3 User Manual PBI D 04/2013

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

WS/S, /SD Wind Speed and Direction Sensors

FAS-W. Features. Applications. Automatic condensation hygrometer

M iniature Amplified Pressure Sensors

2.07 Amperometric Sensors

AMS 6915 Board mount pressure sensor with digital output (I²C)

Transcription:

Gas Sensor (MQ5) Description The AZL- Gas Sensor (MQ5) module is useful for gas leakage detection (in home and industry). It is suitable for detecting H2, LPG, CH4, CO, Alcohol. Due to its high sensitivity and fast response time, measurements can be taken as soon as possible. The sensitivity of the sensor can be adjusted by using the potentiometer. Features Wide detecting scope Stable and long life Fast response and High sensitivity Specification Item Parameter Min Typical Max Unit VCC Working Voltage 4.9 5 5.1 V PH Heating consumption 0.5-800 mw RL Load resistance adjustable RH Heater resistance - 31±10% - Ω Rs Sensing Resistance 10-60 kω Scope Detecting Concentration 200-10000 ppm Application Ideas Gas leakage detection. Toys.

Hardware Overview This is an Analog output sensor. This needs to be connected to any one Analog socket in Base Shield. The examples used in this tutorial makes use of A0 analog pin. Connect this module to the A0 port of Base Shield. It is possible to connect the AZL module to Arduino directly by using jumper wires by using the connection as shown in the below table: Arduino Gas Sensor 5V VCC GND GND NC NC Analog A0 SIG The output voltage from the Gas sensor increases when the concentration of gas increases. Sensitivity can be adjusted by varying the potentiometer. Please note that the best preheat time for the sensor is above 24 hours. For detailed information about the MQ-5 sensor, please refer to the data-sheet provided in resource section. Getting Started Connect the AZL- Gas Sensor (MQ5) to A0 port as shown in the above picture.

Gas Detection : Basic Example In this example, the sensor is connected to A0 pin. The voltage read from the sensor is displayed. This value can be used as a threshold to detect any increase/decrease in gas concentration. float sensorvalue; sensorvalue = analogread(a0); sensor_volt = sensorvalue/1024*5.0; Serial.print(sensor_volt); Serial.println("V"); Measurement : Approximation This example demonstrates a way to know the approximate concentration of Gas. As per the data-sheet of the MQ5 sensors, these equations are tested for standard conditions and are not calibrated. It may vary based on change in temperature or humidity. 1.Keep the Gas Sensor in clean air environment. Upload the below program. float RS_air; // Get the value of RS via in a clear air float R0; // Get the value of R0 via in H2 float sensorvalue; /*--- Get a average data by testing 100 times ---*/ for(int x = 0 ; x < 100 ; x++) { sensorvalue = sensorvalue + analogread(a0);

sensorvalue = sensorvalue/100.0; /*-----------------------------------------------*/ sensor_volt = sensorvalue/1024*5.0; RS_air = (5.0-sensor_volt)/sensor_volt; // omit *RL R0 = RS_air/6.5; // The ratio of RS/R0 is 6.5 in a clear air from Graph (Found using WebPlotDigitizer) Serial.print(sensor_volt); Serial.println("V"); Serial.print("R0 = "); Serial.println(R0); <br> 2. Then, open the serial monitor of Arduino IDE. Write down the value of R0 and this needs to be used in the next program. Please node down the R0 after the reading stabilizes. Replace the R0 below with value of R0 tested above. Expose the sensor to any one of the gas listed above. float RS_gas; // Get value of RS in a GAS float ratio; // Get ratio RS_GAS/RS_air int sensorvalue = analogread(a0); sensor_volt=(float)sensorvalue/1024*5.0; RS_gas = (5.0-sensor_volt)/sensor_volt; // omit *RL /*-Replace the name "R0" with the value of R0 in the demo of First Test -*/ ratio = RS_gas/R0; // ratio = RS/R0 /*-----------------------------------------------------------------------*/ Serial.println(sensor_volt);

Serial.print("RS_ratio = "); Serial.println(RS_gas); Serial.print("Rs/R0 = "); Serial.println(ratio); Serial.print("\n\n"); <br> Now, we can get the concentration of gas from the below figure According to the figure, we can see that the minimum concentration we can test is 200ppm and the maximum is 10000ppm, in other words, we can get a concentration of gas between 0.02% and 1%. However, we can't provide a formula because the relation between ratio and concentration is nonlinear.