TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Similar documents
Anti-flood device Model B-1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Q= Cv S

Speed control assembly model A-1

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA CAUTION

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA CAUTION

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Q = C v P S

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

TECHNICAL DATA ACCELERATOR MODEL E-1

100C Air Compressor Kit

TECHNICAL DATA OBSOLETE

200 PSI COMPRESSORS - MODEL NUMBERS

TECHNICAL DATA. Q = C v P S

Model PSI Compressor with 3-Gallon Air Tank 12VDC

444C DUAL PERFORMANCE VALUE PACK

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

200 PSI FAST-FILL AIR SOURCE KIT

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TECHNICAL DATA Q= C. Table 1 - Specifications

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

200 PSI HIGH-FLOW AIR SOURCE KIT

400C & 450C DUAL PERFORMANCE VALUE PACKS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TECHNICAL DATA OBSOLETE

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

NGP-250/500 Nitrogen Generator Quick Start Guide

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Portable Oil Lube Air Compressors

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

OBSOLETE. Wet pipe low flow manifold system

Types 749B and R130 Changeover Manifolds

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Budget Range Operators Handbook

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

OPERATION MANUAL NTF-15

Part IV: Troubleshooting

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

FACTORY SERVICED 8 Gallon Air Compressor. Model: Important Safety Instructions RISK OF EXPLOSION OR FIRE:

SPECIFICATIONS ATTENTION

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

8-gallon Air Compressor. Owner s Manual

System Pressure Manager Standard & System Pressure Manager Plus

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Wet pipe low flow foam/water system

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

OPERATION MANUAL NTF-60 Plus

IMPORTANT SAFETY INSTRUCTIONS

480C DUAL PERFORMANCE VALUE PACK

accidents which arise due to non-observance of these instructions and the safety information herein.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Inert Air (N2) Systems Manual

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

GM Series Dual-Block Multi-Function Gas Control Valves

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DUAL 444C ONBOARD AIR SYSTEM

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

EGL-12 OIL-LESS COMPRESSOR

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Bermad Pressure Reducing. Model: 42T

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Transcription:

Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a regulated (by pressure switch setting) and restricted (60 Cycle - 3.03 SCFM average free air from 0 to 40 psi gauge) or (50 Cycle - 2.50 SCFM average free air from 0 to 40 psi gauge) air supply. A pressure relief valve is factory installed to prevent pressurizing the system piping above 75 PSI (5.2 bar). The Model G-1 is for use when system pressures are required to be over 20 PSI (1.0 bar). The Viking Model G-1 Maintenance Air Compressor may be used to automatically maintain air pressure in a dry system after the system has been filled from a non-continuous air supply. It may be used as a basic air supply for dry systems of 250 gallons (60 Hz) and 206 gallons (50 Hz) capacity or smaller. 1-A FEATURES A. Carbon steel mounting bracket with stainless steel adjustable straps. One size bracket fits pipe sizes of 2-6 (50.8 mm - 152.4 mm). B. Adjustable pressure switch. C. Check valve factory installed at the compressor outlet. D. A pressure relief valve is factory installed at the compressor outlet to prevent pressurizing the system piping above 75 PSI (5.2 bar). 2. LISTINGS AND APPROVALS culus Listed: Classes VDUR and VDUR7 - Part No. 19191 and 19192 only FM Approved: Class 1032 - Part Nos. 19191, 19192, and 19193 3. Specifications: Part No. 19191: 115V single phase, 60 Cycle AC - Service Factor Amperage: 7.4, Factory Wired 115 V Part No. 19193: 230V single phase, 50 Cycle AC - Service Factor Amperage: 2.6, Factory Wired 230 V Part No. 19192: 230V single phase, 60 Cycle AC - Service Factor Amperage: 3.7, Factory Wired 230 V Pressure Range: 15-60 PSI (1.0 to 4.1 bar) Pressure Differential: 7-15 PSI (0.5 to 1.0 bar) Pressure Switch Factory Setting: 30 PSI (2.1 bar) Cut-in / 40 PSI (2.8 bar) Cut-out Motor Compressor Unit: 1/3 Horsepower, direct drive for 60 Hz 1/3 Horsepower, direct drive for 50 Hz Permanently lubricated bearings Self-lubricating pistons Stainless Steel valves Automatically resetting thermal protection 60 cycle compressor (1/2 NPT outlet) produces 3.03 SCFM average free air flow from 0 to 40 psi - pressure differential 7 to 15 psi 50 cycle compressor (1/2 NPT outlet) produces 2.50 SCFM average free air flow from 0 to 40 psi - pressure differential 7 to 15 psi Safety Relief Valve set at 75 PSI (5.2 bar). Do not attempt to change the safety relief valve setting. Shipping weight of complete assembly: 42 pounds (19 kg). Recommended ambient temperature range: 40 F to 110 F (4.4 C to 43 C). Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. COMPRESSOR PRESSURE RELIEF VALVE IS SET TO OPEN AT 75 PSI (5.2 BAR). COMPRESSOR WILL RUN CONTINUOUSLY WHEN THE SWITCH IS SET AT OR ABOVE 75 PSI (5.2 BAR). CYCLE SWITCH TO DETERMINE ACTUAL SETTING BEFORE PROCEEDING WITH RE-ADJUSTMENT. Proof-tested to maintain accuracy and withstand occasional maximum pressure of 250 PSI (17.2 bar), to allow hydrostatic testing after installation. Form No. F_112613 New page 131h-k, Issued November 25, 2013

Dry 131i November 25, 2013 4. INSTALLATION This unit is intended for installation indoors for use on dry sprinkler systems in accordance with the Standard for Installation of Sprinkler Systems (NFPA 13) and the National Electrical Code (NFPA 70). The compressor must be installed in an area not exposed to the weather, freezing temperatures, or physical damage. Do not operate this compressor if damaged during shipment, handling, or use. Damage may result in bursting and cause injury or property damage. This compressor is not equipped and should NOT be used as is to supply breathing quality air. Motors, electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases near the compressor. These compressors are suitable for pumping only atmospheric air. As defined in Compressed Gas Association Pamphlet G-7, page 3, atmospheric air is a mixture of elements and compounds where nitrogen and oxygen comprise more than 99% with all other trace gases comprising less than 1%. DO NOT USE THIS COMPRESSOR IN CONTAMINATED ENVIRONMENTS OR FOR PUMPING MIXTURES OTHER THAN ATMOSPHERIC AIR Compressed air contains liquid water and is saturated with water vapor, which can freeze. Do not connect compressor outlet to freezer rooms or systems exposed to temperatures below freezing. If system connects to a freezer room or area exposed to freezing temperatures, a Dry Air Pac should be used. Do not connect compressor intake to freezer room. CALL 1-877-384-5464. Locate the compressor in a clean, well-ventilated area where the air is relatively cool, clean, and dry. A 110 o F (35 C) maximum and 40 o F (4.5 C) minimum temperature for surrounding and inlet air are recommended. Provide at least 12 to 18 inches (304 mm to 457 mm) from any wall or other obstruction that will interfere with airflow through the motor s fan built into the motor. Blocking airflow through the fan may cause the compressor to over heat. This compressor is designed for non-lubricated service. Bearings are permanently lubricated. Do not lubricate any part of the compressor or motor. The air compressor should be sized to restore and maintain the air pressure in the sprinkler system in accordance with the requirements of NFPA 13. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner s responsibility to verify compatibility with the air maintenance compressor and associated equipment. The compressor outlet includes a check valve. Warranty is void if a separate check valve is not installed to prevent water back flow. For low volume systems, such as pneumatic release lines, it is recommended to install a receiver tank between the compressor and the system being supplied. The Model G-1 Maintenance Air Compressor may be installed vertically or horizontally. Recommended installation is vertical with discharge facing down. There must be at least 12 (305 mm) of clearance from sidewalls, floors, and ceilings to ensure that the unit will operate correctly. Firmly mount the unit to a stable, rigid surface by bolting it through the slotted holes in the motor mounting base. To riser mount the unit, a vertical mounting kit is available. The kit is provided with stainless steel adjustable straps and hardware that make it suitable for mounting to pipe sizes between 2 and 6 (50.8 mm and 152.4 mm) (refer to Figure 1). 1. Place the V notches of the mounting bracket against the riser. a. Place the mounting straps around the riser, and through the square slots provided in the mounting base. b. Tighten the mounting straps. 2. Mount the compressor unit to the mounting bracket. Tighten all bolts four mounting bolt sets are provided. 3. Install the air supply piping from the 1/2 (13 mm) NPT outlet tee of the compressor to the dry system piping. a. When connecting to dry systems equipped with a Viking Model D-2 Accelerator or Model E Accelerator and Model B Anti-flood Device, refer to the appropriate Accelerator trim chart. Connect the compressor outlet to the trim as

Dry 131j indicated in the trim chart. b. Apply a small amount of pipe-joint compound or tape to the external threads of all pipe connections required. Take care not to allow any compound, tape, or other foreign matter inside any of the nipples or compressor outlet. 4. Connect the electrical supply from an uninterrupted, dedicated circuit. The field wiring for the unit is made inside the pressure regulating switch. The switch is factory preset and sealed to cutout at 40 PSI (2.8 bar). DO NOT ADJUST ABOVE 60 PSI (4.1 bar). Inadequate wiring size can cause insufficient voltage at the compressor during start-up. Overheating and damage to the motor and controls may result. a. The compressor motor and pressure switch are factory wired. b. Remove the access cover shown in Figure 2 (screw driver is required). c. Connect wires as shown in Figure 1 wiring diagram. NOTE: Comply with all national and local codes and requirements of the Authority Having Jurisdiction. d. Reinstall the switch access cover prior to operating the compressor. e. DO NOT exceed the electrical ratings shown on the switch or motor nameplates. 5. Test the compressor pressure switch setting, noting the pressure at which the compressor starts and shuts off. Adjust the pressure switch to the required setting 6. Pressure switch adjustment procedure (see to Figure 1): Failure to use the pressure switch may result in overpressure of the compressor or other components in the system. Overpressure of the compressor may result in blown head gaskets or other damage. a. The large metallic screw (A) is used first to adjust the cut-in pressure (the point at which the compressor comes on as system pressure decreases). The small metallic screw (B) is used to adjust the cut-out pressure (the point at which the compressor shuts off on rising pressure). b. With no pressure on the system, energize the circuit. The compressor should start immediately. c. Allow the compressor to run until it shuts sown and note the pressure reading (cut-out pressure). Bleed air out of the system until the compressor restarts and note the pressure reading (cut-in pressure). d. If the cut-in point is not satisfactory, adjust the large metal screw (A) after the compressor stops (clockwise increases COPPER WIRE ONLY LINE 1 (A) RANGE SCREW MOTOR LINE 2 (B) PRESSURE DIFFERENTIAL SCREW GROUND Figure 1 - Hubbell Pressure Switch

Dry 131k November 25, 2013 the pressure) Repeat the bleeding and adjusting until the cut-in point is correct. Each time the compressor stops note the cut-out point which will be changing each time you adjust the large metallic screw. e. Adjust the small metallic screw (B) to raise (clock-wise) or lower the cut-out pressure from the last noted reading and repeat the bleeding operation. The cut-in point should remain the same each time. Single-phase oil-less compressors can not be operated at 208V.Operating the compressor at 208V voids the warranty. Single-phase motors includeinternal thermal overload protection, which has an automatic reset device. Do not run two phases of a three phase supply through the pressure switch. Serious damage can result. 5. INSPECTIONS, TESTS AND MAINTENANCE DISCONNECT, TAG AND LOCK OUT POWER SOURCE THEN RELEASE ALL PRESSURE FROM THE SYSTEM BEFORE ATTEMPTING TO INSTALL, SERVICE, RELOCATE OR PERFORM ANY SERVICE. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPCB, and VdS, which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. Inspections: It is imperative that the system is inspected and tested on a regular basis. The frequency of the inspections may vary due to contaminated or corrosive water supplies and corrosive atmospheres. In addition, the alarm devices or other connected equipment may require more frequent inspections. Refer to the technical data, system description, applicable codes, and Authority Having Jurisdiction for minimum requirements. WEEKLY Drain condensate from receiver and traps. Check for unusual noise or vibration. Clean air filters. Do not clean filters with petroleum based products. Clean all external parts of the compressor and motor. MONTHLY Manually test safety relief valve. Inspect air system for leaks and tighten nuts and cap screws as required. QUARTERLY Change filters. Maintenance: The compressor motor is equipped with thermal protectors that reset automatically. Disconnect electrical power before servicing. Thermal protector can automatically start the motor when the device resets. 1. The motor compressor unit should be kept dirt-free. 2. The compressor inlet filter should be cleaned or replaced as required. a. To inspect the inlet filter, pull the plastic cap to remove it from the filter case. b. The filter can be removed for inspection. DO NOT clean filter elements with petroleum-based products. c. Re-install the filter and cap. DO NOT operate the compressor without a filter. 3. DO NOT lubricate the compressor or motor. The bearings are permanently lubricated and sealed. 6. AVAILABILITY The Viking Maintenance Air Compressor is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. 7. GUARANTEES For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Dry 131l 1 3 2 4 ITEM PART NUMBER DESCRIPTION NO. REQ D 1 19313 Relief Valve 1 2 19312 Pressure Switch 1 5 3 19311 Check Valve 1 4 19310 Air Filter 1 5 19309 Mounting Bracket Kit 1 Figure 2 - Replacement Parts Figure 3 - Pressure Switch Wiring Diagram Form No. F_112613 New page 131h-k, Issued November 25, 2013