Akasison Flow phenomena of a siphonic roof outlet

Similar documents
Flow phenomena of a siphonic roof outlet arc Buitenhuis Abstract Introduction

Experiment Instructions

Free Surface Flow Simulation with ACUSIM in the Water Industry

Projectiles Shot up at an Angle

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Chapter 15 Fluid. Density

Bernoulli's Principle

ADVANCES in NATURAL and APPLIED SCIENCES

Methods The experiments were carried out in the wind tunnel in the Air physics laboratory at the Engineering Centre Bygholm as shown in figure 1.

Pressure reducing valves Index

Sound scattering by hydrodynamic wakes of sea animals

Application of CFD for Improved Vertical Column Induced Gas Flotation (IGF) System Development

Lecture Outline Chapter 15. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Combination Air Valve

Chapter 15 Fluids. Copyright 2010 Pearson Education, Inc.

Float operated valve TYPE (SWDS)

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

POWERED FLIGHT HOVERING FLIGHT

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

Exercises The Atmosphere (page 383) 20.2 Atmospheric Pressure (pages )

Combination Air Valve Model

Experimental investigation of the check valve behaviour when the flow is reversing

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

Lecture 10 : Sewer Appurtenances

CSO/STORMWATER MANAGEMENT. HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

SAFETY BULLETIN HOSE WHIPPING HOW TO AVOID INJURY BY A HOSE WHIPPING FROM RELEASE OF TRAPPED AIR AMERICAN CONCRETE PUMPING ASSOCIATION

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

HYDRAULICS. H89.8D - Hydraulic Bench

Development of Biomimicry Wind Louver Surface Design

HL Article. Air admittance valves DN50 DN75

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

DAV - MP DAV - MP. Metallic-Shield Air Valves. Product Catalogue. (Metallic-Shield Air Valves) DAV - MP

Bubble Coalescence and Breakup in Gas-Liquid Stirred Tank Reactors

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

Product Catalogue DAV - P DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

THE INFLOW OF UNWANTED AIR

Homework Exercise to prepare for Class #2.

ROMPA SUPA SPARKLE BUBBLE TUBE 20288

Float Valve Function and Design Considerations

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

VACUVENT Valve functions - benefits - flowpath - VG series - Sewage

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Structure of Mechanically Agitated Gas-Liquid Contactors

Air Eliminators and Combination Air Eliminators Strainers

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Aalborg Universitet. Published in: Proceedings of Offshore Wind 2007 Conference & Exhibition. Publication date: 2007

Investigation of Suction Process of Scroll Compressors

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

The following article was authored by Jacques Chaurette of Fluide Design, Inc. ( All rights reserved. - HOW DOES A SIPHON WORK?

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

science-u.org How do you launch a rocket without using Air Pressure Rockets Directions You Will Need ESTIMATED TIME Minutes

Crispin Valves Technical Reference Manual. Crispin

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Modelling of Pressurised Pipes within InfoWorks ICM and CS

GEA FOR ADVANCED STRUCTURAL DYNAMIC ANALYSIS

Potential and Kinetic Energy: The Roller Coaster Lab Student Version

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

Applied Fluid Mechanics

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

Item 404 Driving Piling

Causes and Remedies to 7 Instability Patterns in Blown Film Extrusion

Figure 1 Figure 1 shows the involved forces that must be taken into consideration for rudder design. Among the most widely known profiles, the most su

Memorandum. Dr. Wilbert Odem, Dr. Paul Trotta, and Mr. Justin Ramsey. From: Timothy Mahon, Patrick Belsheim, and Ali Alrayyes.

Construction Dewatering

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Yasuyuki Hirose 1. Abstract

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Air Bubble Departure on a Superhydrophobic Surface

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Experiment (13): Flow channel

CASE STUDY FOR USE WITH SECTION B

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

my SYSTEM A guide to common applications in water distribution systems

Centrifugal Pump Intro

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

Finite Element Analysis on Trapezoidal Tank to Suppress Sloshing Effect

Applications of Bernoulli s principle. Principle states that areas with faster moving fluids will experience less pressure

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

Uncontrolled copy not subject to amendment. Principles of Flight

Improving Conventional Flotation Methods to Treat EOR Polymer Rich Produced Water

Khosla's theory. After studying a lot of dam failure constructed based on Bligh s theory, Khosla came out with the following;

Mechanical waves Electromagnetic waves

Ripple Tank with LED-light source, complete

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

Statnamic Load Testing Using Water as Reaction Mass

C) miles per hour. D) all of the above. 2) When you look at the speedometer in a moving car, you can see the car's

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Digester Processes. 1. Raw Sludge Pumping System

Impact of Signalized Intersection on Vehicle Queue Length At Uthm Main Entrance Mohd Zulhilmi Abdul Halim 1,b, Joewono Prasetijo 2,b

Pressure coefficient on flat roofs of rectangular buildings

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Transcription:

Akasison Flow phenomena of a siphonic roof outlet

Ir. Marc Buitenhuis MTD Hydraulic research engineer Akatherm BV, Panningen, The Netherlands 06-01-2011 Abstract So far the investigations on siphonic roof drainage systems have been focused on the functioning of the system as a whole. In this report the focus will be on the roof outlet and the phenomena observed during tests in a test rig according to the EN 1253 and ASME A112 standards for roof outlets. This comprises the test of a single roof outlet in a siphonic configuration. The primary goal of the tests was to design a well functioning all plastic improved roof outlet, which is currently in production. During the tests some remarkable phenomena typical of siphonic roof outlets were observed, that will be presented in this report. It appeared that air ingress follows a path of decreasing size of air pockets (plugs to bubbles), followed by a decrease in number of bubbles. The noise level produced by the roof outlet is correlated with this phenomenon. Further it was observed that a disc alone is not sufficient to keep the air out of the system and that additional measures, like fins on top of the airbaffle, are necessary to prevent the development of large vortices that are capable of dragging air in to the system. Also it was observed that waves reflect from the edges of the disc and fins of the airbaffle leading to an interference pattern of waves around the roof outlet. It was observed that the air is still being sucked in from a certain discharge rate after the water level has reached the height of the disc of the airbaffle. At first large plugs of air are being dragged in, but with increasing water level the plugs become bubbles decreasing in size and increasing in number. The noise level appears to be correlated to this phenomenon. Finally a pumping behavior was observed at the outlet when having become siphonic that is probably correlated to instabilities of the flow at the exit of the pipe system. Keywords Siphonic roof drainage system; roof outlet; two-phase flow.

1. Introduction Siphonic roof drainage systems are gaining more and more ground in the drainage of rain water from large flat roofs because of their cost effective, space saving design and high performance. Significant work has been done by several institutes to describe the principles of the system. The design of the siphonic roof outlet on top of this system has not been investigated this intensively thus far. Therefore tests have been performed with our in-house test rig to gain insight in the principles of the roof outlet design leading to the development of an all plastic siphonic roof outlet for roof drainage systems exceeding all requirements of the EN and ANSI standards and the build up of a vast knowledge of the functioning of a siphonic roof outlet. The tests have been performed in a single roof outlet siphonic configuration. Illustration 1: test rig. On top a special component has been developed to use the roof outlet in an emergency roof outlet configuration as well without a significant decrease in performance compared to the standard roof outlet. In this paper the phenomena observed at the siphonic roof outlet will be described one by one. First of all the siphonic roof drainage system itself and its components will be described in paragraph 1. Then in paragraph 2 the basic working principle will be described. Following in paragraph 3 the flow phenomena occurring at the roof outlet will be described.

2. Siphonic roof drainage system and it s components A siphonic roof drainage systems consists of one or more roof outlets [1] followed by an equal amount of vertical tail pipes [2] which leads the flow into a horizontal collector pipe [3] that ends in a vertical fall pipe [4] (see illustration 2). As stated before the tests have been performed on a single roof outlet configuration. The emergency roof outlet has also been tested as a single roof outlet configuration, thus not in conjunction with a regular roof outlet system. Illustration 3: siphonic roof outlet The roof plate is a specially designed plate with a hole with smoothly rounded edges, which is the opening to the pipe system. The airbaffle is mounted over the opening in the roof plate to prevent air from being drained into the pipe system (as will be further explained in a following paragraph). The connector is mounted on the bottom part of the roof plate to connect the roof plate to the pipe system. The function of the leafguard is to keep out rough sized debris that can possibly block the system. Illustration 2: siphonic roof drainage system. The roof outlets form the entrance from the roof to the pipe system. The tail pipes guide the water down to the collector pipe, which is not only collecting the water from all roof outlets but also guides it horizontally to one side of a building, where the fall pipe transports it downward towards the sewer. The roof outlet consists of a roof plate [A], a so called airbaffle [B] and a connector to attach it to the pipe system [C] and possibly a leaf guard [D] (which in our design has been integrated in the airbaffle design [B]). Illustration 3 presents the roof outlet and its components.

3. Working principle of the roof drainage system The siphonic roof drainage system is based on the principle of full bore flow. This means that the system is designed to obtain a flow through the system that fills the whole diameter of the pipe, thereby creating a vacuum upstream dragging more water in from the roof, thereby reaching a high discharge rate through a relatively small diameter pipe system. To obtain a full bore flow the water must be forced to fill the whole diameter, which can be done by decelerating it, e.g. in a horizontal collector pipe, which leads to a so called hydraulic jump, that can force the flow to fill the whole diameter of the pipe (see illustration 4). The system is already functioning as a siphonic system when about 60% of the system is filled with water. The air is still present then, but the system is no longer ventilated from top to bottom and thus the water falling down creates an underpressure, sucking in more water from the roof. The siphonic roof drainage system must be designed such that a once a year rain storm can be transported from the roof before the roof construction is endangered. This is done by a proper choice of pipe diameters in the system. This also means that the system will work conservatively (carrying air) for most regular rainfall events and siphonically on some cases of heavy rainfall. In case of more extreme rain storms an emergency roof drainage system must come into play to drain the excess of rainwater up to a maximum sum falling during a once in a 100 year rain storm. The exact numbers for rainfall intensity for and capacity of a regular and emergency system and the allowable waterlevels on the roof can differ from country to country. Illustration 4: working principle of siphonic roof drainage system. The hydraulic jump is like the piling up of cars in a traffic jam after a slow turn in the highway. The water curtain at the end of the tail pipe and the flow through the elbows before the fall pipe is characterized by a ventilated mixture of water and air as long as the flow has not become siphonic. The gravity driven flow in the fall pipe accelerates the flow, and after becoming siphonic drags the water down functioning as the engine of the system. So the water falling down the tail pipe, accelerating on its way down, is being decelerated in the collector pipe to make it flow full bore when enough water is discharged through the pipe system and is being accelerated in the fall pipe. When the hydraulic jump is able to fill the pipe diameter the water will try to force out the air in front against the upward buoyancy forces of the air while filling the tail pipe upstream at the same time. This process is called priming.

4. Flow phenomena at the roof outlet The roof outlet must prevent air from entering the siphonic roof drainage system to initiate full bore flow while having as less resistance to the system as possible to obtain a maximum discharge flow and minimum water height on the roof. 4.1 Air ingress When there would not be an airbaffle, the water that is being dragged down the pipe system would drag air along at the water surface. The water will accelerate towards the roof outlet. The velocity component of the surrounding water will increase with the 4.2 Air baffle design To prevent air from being dragged in a disc could be mounted on top of the pipe system. This will stop the air from being dragged in with the water flow. Unfortunately this will not be sufficient, since the water will still swirl around the disc and create a vortex that drags in air underneath the disc. A vortex accelerates the flow with a maximum in its center, creating an under pressure. By Bernoulli s Law again this means the water surface is lowered, which can result in a local dip that creates the opportunity for air to find its way underneath the roof outlet. Fins are necessary to break the vortex formation up in smaller vortices that are not strong enough to drag in air underneath the disc. decrease of the radius around the roof outlet ( ). Following Bernoulli s law the increasing velocity towards the pipe system will mean the waterheight will be decreasing towards the pipe (since and thus h will decrease with increasing v under the condition of atmospheric pressure at the surface). The water flowing towards the pipe system will drag air along at its surface, dragging it into the pipe system. (a) no disc or airbaffle, large vortex. Illustration 5: air being dragged in with the flow of water. (b) disc, vortex at edge of disc (ink injected). In theory this would be a symmetric situation occurring equally from all directions. In practice small disturbances (both in the construction of the roof outlet, water flow and in environmental air flow) will lead to a swirling flow towards the pipe system (vortex creation) similar as the vortex seen when emptying a bathtub. (c) disc with fins, no vortex (ink injected). Illustration 6: roof outlet with no disc (a), with disc (b), with disc with fins (c).

4.3 phenomena typical for siphonic roof outlets Using a disc shaped airbaffle design with fins leads to some specific phenomena. As soon as the water level around the airbaffle reaches the disc of the airbaffle (note that the water level is decreasing towards the airbaffle and thus the overall water level is higher) the water will close of the path for air to enter the system. Due to under pressures increasing with the discharge rate however, from a certain discharge rate the air will be sucked in. At first this is by large plugs of air, but when the water level rises they become bubbles decreasing in size with the water level. At a further increase of the water level the number of bubbles will decrease. The air being sucked in will collect underneath the disc of the airbaffle from where it will be sucked in to the pipe system. The collision of water on the edge of the disc and fins of the airbaffle will lead to reflection waves. This is seen as an interference pattern of waves around the roof outlet, which becomes more significant at higher discharge rates. The above phenomena are illustrated in the illustration below. When the water level increases the plugs get shorter until bubbles remain (illustration 8b). The air has to overcome an increasing resistance by the water to find its way in when the water takes in more and more space above the airbaffle. When the discharge rate increases further the size of the bubbles decreases while the amount of bubbles increases (illustration 8c). (a) large plugs of air just after reaching closure of water surface at the disc of the airbaffle. Illustration 7: flow phenomena at roof outlet. (b) large air bubbles due to higher waterlevel breaking up the plugs. As long as the water level is below the lower edge of the disc the air will be dragged in with the water as in a conventional system, the only influence of the airbaffle being the prevention of a large vortex by the fin shaped ribs on which the baffle stands. When the water level reaches the edge of the disc the air can not freely enter the system anymore but has to be sucked in by the under pressure generated by the water flow. At a low discharge rate the flow velocity is too low to drag in air, but when the water velocity increases large plugs of air manage to pass underneath the disc (illustration 8a). Initially the water is only occasionally capable of closing the gap for air to enter underneath the disc. (c) small bubbles at increased waterlevel, but well before siphonic flow, inducing a high noise level. Illustration 8: air ingress underneath airbaffle (transparent).

When the water level rises further the frequency of the bubbles diminishes until the air is no longer capable of getting underneath the disc (the air is no longer capable of breaking the water surface to find its way in while the under pressure at the water surface diminishes as the water level rises above the airbaffle disc) and full bore flow is a fact. When the flow has become fully siphonic a wave train is seen at the water surface around the airbaffle every 0.75 s (thus at a frequency of 1.333 Hz). It looks like the roof outlet is pumping out water at this frequency producing a wave train with every pump stroke. In reality the water intake will be restricted every 0.75 s, probably because of a pressure wave traveling upstream from the exit. 4.4 Noise levels Along with the break up in smaller plugs and bubbles the noise production rises as the noise is a result of the opening and closing of the water surface on the edge of the disc, which occurs more frequently when bubbles are dragged in at a high frequency. When the frequency of the bubbles diminishes so does the noise production (because of the fewer opening and closing incidents of the water surface on the edge of the disc, see illustration 9 below). At full siphonic flow the Ø75 roof outlet (with butt welded pipes) transports approximately 16.5 l/s, which converts to a mean velocity of 4.4 m/s in the pipe. Since the pipe system is 4.2 m (total fall height) +1.5 m (length of horizontal collector pipe) = 5.7 m long and the wave frequency is 1.333 Hz the speed at which the wave travels up and down the system is 5.7*2*1.333 = 15.2 m/s, which is approximately 3.5 times the velocity through the pipe. Indeed the exit flow is not a straight jet, it wobbles from left to right, although the frequency reported above can not be confirmed. The swinging motion appears to occur at a frequency of 8 Hz (=6*1.333 Hz)! Illustration 9: typical noise curve of siphonic roof outlet. It is not clear how to explain the factor of 6 between the wobbling of the exit flow and the wave frequency at the roof outlet.

Presentation of Author Marc Buitenhuis is a hydraulic research engineer at Akatherm BV, Panningen, The Netherlands. He s involved in the design of siphonic roof drainage systems and high-rise soil and waste drainage systems and their components, performing both hydraulic tests and CFD computations.

Akatherm BV Industrieterrein 11 P.O. Box 7149 5980 AC Panningen The Netherlands Tel +31 (0)77 30 88 650 Fax +31 (0)77 30 75 232 info@akasison.com www.akasison.com 02/16/329