HYDRAULIC CYLINDER TEST

Similar documents
Troubleshooting Lift Cylinder Drift and Tilt Cylinder Drift

Introduction. Part one: Identify the Hydraulic Trainer Components

Service Call: Procedure for Bleeding the Hydraulic Leveling System. Tools Required: S-Wrench 1/2, 9/16, 5/8, 11/16, & 3/4 Drain Pan

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Hydraulic Reliability & Preventive Maintenance Report

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

Instruction sheet for Hydraulic Cylinder

Section 3- Repair and Calibration Procedures

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Operation Manual Guillotine Cutter RC-5

Inert Air (N2) Systems Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Hydraulic Punch Drivers

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE

Copyright, 2005 GPM Hydraulic Consulting, Inc.

MANUAL BE SERIES Test Benches

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

OPERATING INSTRUCTIONS FOR HTWP21 SERIES AIR DRIVEN TORQUE PUMPS

Lesson 6: Flow Control Valves

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Flexfence Swaging Unit. Product Manual. Release 02/16.

MB-SP Series Solvent Purification System

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

DBML-60/80 Squeeze Tool

Rhino VE CE Bulk Unloader Operator s Card

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Interface Devices, Inc. Hydraulic Mini Mule

444C DUAL PERFORMANCE VALUE PACK

OPERATING AND MAINTENANCE MANUAL

DK ton, Double-acting, Die-type Crimping Tool

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Operating Instructions for: PQ120 Pump Series. PQ120 Series Pump SPX

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

400C & 450C DUAL PERFORMANCE VALUE PACKS

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

35 TON HYDRAULIC PUNCH WARNING

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Operating Procedure TITON SUBSEA BOLT TENSIONER

Captain Wellhead & Tree

20 Ton SD Shop Press Operating Instructions

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

TECHNICAL DATA. Q = C v P S

KJ4000 Operating Instructions & Parts Manual NSN

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

SINORIX Valve Reconditioning

Rejuvenation Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Linde Hydraulics Corporation, P.O. Box 82, Canfield, Ohio 44406

Warning: NEVER ALTER TEST EQUIPMENT

Winter Shut Down Procedure

BIMA cryogenics (Dick Plambeck, 18jan2007)

TECHNICAL DATA. Q = C v P S

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Pro-Source Steel Pressure Tank

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

Hydraulic Piston Accumulators

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

R E D I C O N T R O L S

BRAKE SYSTEM BLEEDING

100C Air Compressor Kit

JACK MODULE HYDRAULIC CYLINDERS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

200 PSI COMPRESSORS - MODEL NUMBERS

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Product Information News

Hydrostatic Pressure Testing

Installation and Use Manual

Installation of Your SprayMaster System

PRESSURE ADJUSTMENT Main pressure adjustment

TECHNICAL DATA. Q = C v P S

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Document How to Set Single Stage Press Pressures

36H SERIES Combination Gas Valve

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

4-Ball Lowers 750cc, 1000cc, 1500cc, and 2000cc Models

Related Products: Auto Drain Valve. Model/Specifications. Model

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Installing ASI Umbilical Delivery Systems

SPECIFICATIONS ATTENTION

Transcription:

In the event that a coach equipped with hydraulic slide-outs begins to experience room drift, whether the room drifts out after retract, or drifting in after extension, a test of the hydraulic cylinders should be performed. Hydraulic Landing Gear (HLG), Rear Stab Jacks or Leveling Jacks 1. Retract jack in question. If retracting HLG, both jacks will retract. If retracting leveling jack, all jacks will retract. 2. Once jack is fully retracted, remove the extend hose (hose located at the top of the jack). If testing ROAD SIDE HLG or REAR STAB JACKS, the hose will be mounted to a red restricted flow valve block. Do not attempt to EXTEND jack. The system will experience RAPID FLUID LOSS. 3. When the hose is removed, push the RETRACT button again. A. If fluid comes from the jack while the retract button is being pressed, the hydraulic cylinder is bypassing the internal seal and must be replaced. (See TI-120 for this procedure.) B. If no fluid comes from the cylinder during this retract procedure, the cylinder is good. C. If no fluid comes from the JACK but does come from the HOSE, test the opposite jack (HLG and Rear Stabs only). Be sure to reconnect and tighten EXTEND hose. System will experience rapid fluid loss if hose is not reconnected. Hydraulic Slide-out Cylinder - Retract Test 1. Retract (close) all slide-outs (rooms) completely. 2. Disconnect all rooms from system (if coach is equipped with IRC, close all but one room). 3. Loosen hose from E (extend) port on the manifold of the Power Unit. 4. Plug opening on manifold to prevent drawing air into the system. Do not attempt to run room out with the E port hose loose. The system will experience rapid fluid loss. 5. Energize the Pump Unit to retract (close) room. 6. When room is fully retracted, continue to run the room in and watch for fluid flow from hose/port E. Fluid flow greater than a few drops will indicate internal cylinder leaking (bypassing of piston seal). If greater than a few drops leak from hose fitting, piston seal is bad and will need to be replaced. If there is no fluid flow, reconnect hose to E port and tighten. 7. Repeat steps 2 through 6 for each slide-out until all slide-outs have been tested. Energize the Pump Unit to retract (close) room. Be sure to reconnect and tighten hose at the E port before attempting to extend (open) the room or the system will experience rapid fluid loss. Rev: 03.09.2017 Page 1

Hydraulic Slide-out Cylinder - Extend test 1. Extend (open) all slide-outs (rooms) completely. 2. Disconnect all rooms from system (if coach is equipped with IRC, open all but one room). 3. Loosen hose from R (retract) port on the manifold of the Power Unit. Individual slide-outs can be tested if the unit is equipped with an IRC block. Close all valves in IRC except the one to be tested. Do not attempt to run room in with the R port hose loose. The system will experience rapid fluid loss. 4. Plug opening on manifold to prevent drawing air into the system. 5. Energize the Pump Unit to extend (open) room. 6. Continue to run the room out and watch for fluid flow from hose/port R" (or IRC block if coach is equipped with IRC). Fluid flow greater than a few drops will indicate internal cylinder leaking (bypassing of piston seal). If greater than a few drops leak from hose fitting, piston seal is bad and will need to be replaced. If there is no fluid flow, reconnect hose to R port and tighten. 7. Repeat steps 2 through 6 for each slide-out until all slide-outs have been tested. Be sure to reconnect and tighten hose at the R port before attempting to retract (close) the room or the system will experience rapid fluid loss. Rev: 03.09.2017 Page 2

Cylinder Check - IRC (Individual Room Control) Tools Required Two (2) hydraulic pressure gauges rated @3000 psi min. Standard set of open end wrenches Eye Protection 1. Retract all slide-outs. Check the fluid level in the reservoir. An empty or near empty reservoir is an indication of an external leak. Check for any external leaks around the coach and inspect all hoses. Note any leaks, hose bulging or ballooning. Check for any contaminants in the bottom of the reservoir. 2. Verify extend and retract hydraulic lines are installed in the correct port (Fig. 1). Retract Fig. 1 Extend Rod-end - Piston Rod Standard Slide-out Cylinder Cap-end - Stud 3. Verify the slide-outs are fully extended or fully retracted causing seal to compress. Briefly press the extend or retract button again, depending on the disposition of the slide-out, to confirm full extend or retract. 4. Check the system for internal leaks or bypassing." Hydraulic pressure gauges should be rated for at least 3000 psi minimum. Install a pressure gauge using a female swivel T on the extend and retract fittings of the hydraulic pump (Fig. 2). Note: Fig 2. shows the retract side pressurized. Fig. 3 shows the extend side pressurized. The opposite side should have no pressure as indicated by the valves. Maintain constant ambient temperature throughout test. Fig. 2 Fig. 3 Pump in retract Pump in extend Rev: 03.09.2017 Page 3

5. Retract the slide-outs and record the pressure reading on the gauge. An internal bypass generally is indicated by a significant drop in pressure on the retract side gauge and the slide-out(s) may drift. If the loss of pressure on the retract side results in an increase in the pressure on the extend side, the piston seal inside the slide-out cylinders have failed and the cylinders are bypassing. Individual slideouts can be tested if the unit is equipped with an IRC block. Close all valves in IRC except the one to be tested. Follow the procedure found on Page 1 to isolate and test the first cylinder. Repeat this process until the bypassing cylinder is found. Hydraulic lines will be under pressure. Contact with fluid under pressure can cause bodily injury. Be sure to wear eye protection. To avoid rapid fluid loss when opening a fluid line, make certain the pressure is removed. Prior to opening the extend side of the system, retract the slide-out rooms. Prior to opening the retract side of the system, extend the slide-out rooms. 6. If the retract side gauge drops pressure but the extend side does not, the pump has failed. 7. To remove and replace a cylinder, please follow the procedure found in TI - 120. 8. Installing a new cylinder will introduce a small amount of air into the system. Extend all slide-outs completely, holding the switch for 1-2 seconds at the end of the extend function. Immediately retract all slide-outs and hold the switch in retract 1-2 seconds at the end of the cycle. Check the reservoir for foam or bubbles. This indicates air has been purged from the system. Wait 15-20 minutes before cycling the slide-outs again to prevent reintroducing the air from the reservoir back into the system and to keep the pump motor from overheating. TI - 119 can also be noted for a purge procedure. 9. Once the system leak has been resolved, pressurize the system to perform a leak test overnight, or over the next several hours. Note: Ambient temperature MUST be maintained for the duration of the overnight test to check the effect of pressure on the system. If no leak is detected at the conclusion of the test, the repair is complete. 10. If the system still has a pressure leak, the system may be contaminated and would need a flush and fill procedure performed. See procedure on Page 5. Rev: 03.09.2017 Page 4

Flush and Fill Procedure 1. Extend all systems. 2. Locate all of the slide-out cylinders. 3. Go to furthest cylinder from pump. 4. Remove retract line on cylinder furthest from pump. 5. Place into jug of clean fluid. 6. Attach 4 utility hose to cylinder. 7. Put hose in another jug. 8. Retract all systems. 9. Remove utility hose. 10. Reattach line. 11. Go to extend side and repeat steps. 12. Remove clean fluid out of one jug with hose removed from cylinder. 13. Place utility hose into another jug and drain the contaminated fluid into a clean container. Fluid Requirements - For Keystone Units Only Keystone RV utilizes a 32 wt. hydraulic fluid. In the event of low fluid, the use of 32 wt. hydraulic fluid only is the recommended fluid for replacement. As a supplier of components to the RV industry, safety, education and customer satisfaction are our primary concerns. Should you have any questions, please do not hesitate to contact us at (574) 537-8900 or by email at customerservice@lci1.com. Self-help tips, technical documents, product videos and a training class schedule are available at www.lci1.com or by downloading the MyLCI app. Rev: 03.09.2017 Page 5