Section 2: Using the Invasive Blood Pressure Module - An Introduction

Similar documents
NIBP OEM Module. (Model : M_NIBP) Contents. 1. Concept 2. Composition 3. PCB Dimension 4. Specification 5. Protocol 6. Cuff & Electrical Connection

BLOOD PRESSURE SENSOR 0377i

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

Non-Invasive Blood Pressure (NIBP)

Device Equivalence Evaluation Form

Instruction Manual. Auto Inflate Blood Pressure Monitor

Linear Infl ation Technology Non-invasive Blood Pressure Measurement. inibp Case Report Experiences in OR

Table of Contents. Operators Manual Multi-parameter Patient Monitor " LifeWindow Lite LW8 " 1

Declaration of Equivalence Form

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Noninvasive Blood Pressure Measurement. D. J. McMahon rev cewood

Non-Invasive Blood Pressure

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

Semi-Automatic Blood Pressure Monitor with Memory

Declaration of Equivalence Form

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Digital Blood Pressure Monitor. Model UA-787

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

Analog Front End Design of a Digital Blood Pressure Meter

Lucid System In-Service Training

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Blood Pressure Training System S415

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

User Manual DMD1001 1

RM-80 respiration monitor

hlon Invasive Blood Pressure OEM board NIBP2O2O UP

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX

WARNING: EXPLOSION HAZARD

TD-3140 Blood Pressure Monitor. Owner s Manual

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

TD-3140 Blood Pressure Monitor. Owner s Manual

Lab #2: Blood pressure and peripheral circulation

Instruction Manual. BZ7002 Calibration Software BE

COPYRIGHT Ramsey Medical, Inc.

Sports Wrist Digital Blood Pressure Monitor Item #

Instructions for use. Recognises atrial fibrillation The most frequent cause of stroke. Upper arm PROFESSIONELL TOUCH. Also suitable for:

Blood Pressure Monitor

Declaration of Equivalence Form

Stand-Alone Bubble Detection System

Panther 5 Acute Care Ventilator

VIDEO TUTORIAL: greatergoods.com/0605

Human NIBP Nano. Owner s Guide. Non-invasive hemodynamics. Human NIBP Nano Owner s Guide

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Blood Pressure Monitor Instruction Manual

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

Table of Contents. Operators Manual Multi-parameter patient monitor LifeWindow 6000 Rev 5 Apr Section 1 - Introduction

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Experiment B-18 Heart Rate and Coughing

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Monitoring & Critical Care. Midmark Animal Health Products

Declaration of Equivalence Form

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

WatchBP Office Central

The RICH LIFE Project: Blood Pressure Training Certification Checklists

Blood Pressure Monitor

Upload-pressurized Automatic Sphygmomanometer.

Burner Management System DEMO Operating instructions

Circulation and Respiration: Vital Signs Student Version

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

Opti 24-hour ABPM. User Guide

Blood Pressure Monitoring: Arterial Line

APA software instruction manual

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

ICS Supersedes EN :1997. English Version

HAEMODYNAMIC MONITORING SETUP IN THE CATHETERISATION LABORATORY MAHAT SAPION

Blood Pressure Simulator LF01095U Instruction Manual

OIML R 16-1 RECOMMENDATION. Edition 2002 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-invasive mechanical sphygmomanometers

Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Device Equivalence Evaluation Form

Cardiac Catheterisation Instrumentation. Lancashire & South Cumbria Cardiac Network

Professional Blood Pressure Monitor HBP-1300

ProBP 2400 Digital Blood Pressure Device

WatchBP Office Central

6 Common Hydrodynamic Testing Mistakes

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

ergoselect 150 Bicycle Ergometer Operator s Manual Version / Rev 02 English

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Simulation for emergency care

Evaluation of the Critikon 8100 and Spacelabs non-invasive blood pressure monitors using a test simulator

Automated Blood Pressure Monitor for Cardiac Stress and Exercise Testing User Manual

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

VER: A00. Model No:BA2010

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

VOLAR PRODUCTION TRUCK SCOREBOARD CONTROLLER DATA INTEGRATION

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Operation Manual. AccuPulse is a trademark of Clinical Dynamics Corporation PN: Rev 00

INSTRUCTIONS FOR USE

Experiment B-3 Respiration

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Transcription:

Section 2: Using the Invasive Blood Pressure Module - An Introduction IBP Module - General The Invasive Blood Pressure module is a dual function module that can monitor pulsatile pressure waves such as an arterial pressure wave or static pressure values such as central venous pressure or urinary bladder pressures. The IBP module uses connectors compatible with the DPT- 200/DPT-400 disposable transducers manufactured by Utah Medical. However the actual IBP module will work with any Blood Pressure Module conforming to the uniform standard for Blood Pressure Transducers. In part the standard encompasses the following: Excitation +/- 5v to +/- 10v Output 5uV/V/mm Hg Connections: +5v, -5v, Sig+, Sig-. The DPT-200 and the DPT-400 transducers are identical in form and function. The DPT-200 transducer is suitable for intra-arterial blood pressure monitoring. For static pressure monitoring the DPT-X00 is required. The Sentinel Monitor may be fitted with one or two channels of invasive blood pressure monitor, called IBP1 and IBP2. Each channel behaves in the same manner and transducers are inter-changeable between channels. The settings for each channel are independent so it is possible to have differing alarm rates on each IBP channel, without any cross-interference. In the following description the Invasive Blood Pressure channel is referred to as IBP1. All comments and descriptions relating to IBP1 apply to channel IBP2. Changing between Pulse and Static Mode To change the mode of pressure monitoring touch the screen anywhere in the trace region and select the "SETUP" option. The current IBP mode is indicated by the third button down on the right, e.g. IBP1: PULSE Pressing this button will toggle the mode between "PULSE" and "STATIC". Select whichever option you require and then press "EXIT" to quit the menu and save your changes. Zero-ing the IBP monitor Once the transducer has been attached to the cable and that in turn attached to the VitalStore Monitor, it should be placed at the level of the heart of the patient to be monitored and then zeroed. To zero the IBP1 input, the trace for IBP1 must be showing on the screen. If it is minimised, touch the IBP1 numerical data region at the bottom of the screen and then touch "ADD TRACE". Touch the IBP1 trace region to bring up the trace options for IBP1. The IBP1 ZERO button is immediately above the "SETUP" button. If the blood pressure transducer is not connected, or not recognised the button will say IBP1 ERROR. If the transducer is connected and recognised, the button will say "IBP1 ZERO". Pressing the IBP1 ZERO button will zero the IBP trace to the current pressure input. A zero value needs to be obtained when monitoring in pulse or static mode. Page 16 of 20

Arterial Blood Pressure Monitoring The DPT-200 IBP transducer is connected via an extension cable to the VitalStore Monitor through the 8-way connector on the lower right hand side of the monitor. The DPT-200 transducer is a 3cc/hour constant flow transducer that requires the incoming line of fluid to have a pressure that exceeds the pressure of the input side. This is normally most easily achieved by having the fluid bag held within an inflatable cuff that can be inflated to pressures of 300mmHg for arterial blood pressure monitoring. Connect the transducer, ensure the fluid from the fluid reservoir is flowing through the transducer by pulling on the small tab and then zero the instrument. The input side of the transducer can now be connected to the patient arterial line. A pulse waveform will now be visible on the IBP1 trace. This waveform can be adjusted via the trace options menu that is shown when the IBP1 trace is touched. The trace menu options for IBP1 are: INCR GAIN: Increases the size of the Pressure Trace on the screen. DECR GAIN: Decreases the size of the Pressure Trace on the screen. SHIFT UP: Shifts the Pressure Trace up the screen SHIFT DOWN: Shifts the Pressure Trace down the screen INCR SPEED: Increases the sweep speed of the trace across the screen DECR SPEED: Decreases the sweep speed of the trace across the screen IBP1: ZERO or IBP1: ERROR - see "Zero-ing the IBP monitor above REMOVE TRACE: Removes the trace window from the screen and places the numerical data region at the bottom of the screen. SETUP: Enters the general setup features for the unit EXIT: Exits the menu, saving any changes that have been made Viewing the IBP values The numerical data region to the right hand side of the IBP1 trace region has four fields. The top field in large figures is for the Systolic Pressure. The field immediately below this in slightly smaller figures is the Mean Arterial Pressure and the field immediately below this is the Diastolic pressure field. The field to the right of the pressure measurements is the heart rate as shown by the legend "HR" and gives the measured heart rate in beats per minute. Setting the IBP Alarm Limits The IBP1 alarm limits can be set by touching the IBP1 numerical data region to bring up the ALARM SETUP menu for IBP. There are 4 settable alarm limits: High Heart Rate in bpm Low Heart Rate in bpm High Systolic Pressure in mmhg Low Systolic Pressure in mmhg Page 17 of 20

Change the values of any of these options by pressing the associated UP or DOWN button. Then change the status of the alarm to ENABLED by toggling the DISABLED/ENABLED button. Press EXIT when done. The alarm options are then saved to non-volatile memory and will be remembered after a powerdown. The measurement data from the Sentinel Monitor can be sent to the PC using the USB 2.0 cable supplied. When a PC is connected to the Sentinel Monitor the upper status line will show: CABLE: PC CONNECT. This changeover to PC CONNECT status is automatic and will be retained after a power-down. Central Venous Line Monitoring To monitor a central venous line or other non-pulsatile pressure line, use the STATIC mode of the IBP module. In this mode the reported value on the screen is an instantaneous value of the pressure being measured. No averaging of this data is applied and no interpretation of the waveform is attempted, so there are no resulting peak and trough values reported. For lines requiring peak and trough values use the PULSE mode of the IBP module. The PULSE mode has an adaptive algorithm that will work on peak to trough differences down to 10mmHg. i.e. for the PULSE algorithm to function the peak value must be at least 10mmHg greater than the trough value. Whilst monitoring in STATIC mode, measured data can still be sent to the PC, where it too can be viewed in either PULSE or STATIC mode. Page 18 of 20

Specifications Oscillometric (NIBP) Module Method of measurement: Oscillometric. Diastolic values correspond to Phase 5 Korotkoff sounds Blood Pressure Range: Systolic: 40 265 mmhg MAP: 27-222mmHg Diastolic: 20 200 mmhg Pulse Rate Range: Cuff Deflate Rate: Initial Inflation Pressure: Clinical Accuracy: Pressure Transducer Accuracy Operating Conditions: Storage conditions: Altitude: Startup Initialisation period: Patient Safety: 25 300 BPM (Beats per minute) Deflation step size varies with heart rate, cuff pressure and cuff volume Cuff size 1-3: 160mmHg Cuff size 4+: 160mmHg The Veterinary algorithm is based on the human algorithm that meets accuracy requirements of ANSI/AAMI SP10:1992 and 2002 +/- 3mmHg between 0 mmhg and 300 mmhg for operating conditions between 0 C and 50 C 0C to 50C, 15% to 95% non-condensing humidity -20C to 65C, 15% to 95% non-condensing humidity Measurement accuracy is not affected by altitude 7 seconds Internal operating software ensures that: Maximum cuff inflation time is limited to 75 seconds Duration of blood pressure reading is limited to 120 seconds Additional redundant safety circuitry oversees normal operation and will override to abort a reading if:- Cuff pressure exceeds 300mmHg at anytime The cuff has been inflated for 180 seconds Page 19 of 20

Extras for your Sentinel Blood Pressure Monitor Consumables Part Number: BPCUFFSGL+ size Description: Blood Pressure Cuff Single Hose available in sizes, 1, 2, 3, 4, and 5 For other products and consumables see our web page: http//www.vetronic.co.uk Page 20 of 20