Micrio Tester for the Raymarine ST50, ST60, and ST60+ Wind Instruments. Rev 1.1

Similar documents
WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

GRI-1300/1350Li. User Manual

User Manual GRI- 1500Li

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

TOP BLEED Position for SeaTalk 2 colour logo ST 30. COMPASS Operation and Installation

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Manual Leveling Control Installation/Operation

444C DUAL PERFORMANCE VALUE PACK

Booster Pump PB4-60 Replacement Kits

400C & 450C DUAL PERFORMANCE VALUE PACKS

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

SX150A. Features. Typical Applications. Description

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

User Manual GRX- 1250Li

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

FENCER Under Cabinet LED Light Fixture

PRODUCT SPECIFICATION

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

GasSense NDIR User Manual

Relay Judging Platforms with Speedlights

Good Day. This is the manual of your new Cruzer, inside you should find various items, this guide is going to help you set up your bike properly.

Installation and Operation Instruction Manual

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

MoveRoll Conveyor Operating and Maintenance Manual

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

OPERATION AND INSTALLATION MANUAL

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

Stand-Alone Bubble Detection System

User Instruction Manual For Davit Rescue System

unconventional-airsoft.com

Ecomow Electric Mower

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

WIND. - Instrument - Installation and Operation Manual English

AMS 2710 PCB pressure sensor module with V output

MAKING ELECTRICAL A GUIDE ON HOW TO INSPECT AND TEST PORTABLE APPLIANCES SAFELY AND EFFECTIVELY

200 PSI COMPRESSORS - MODEL NUMBERS

Instruction and Maintenance Manual

Model 400ML Audible Information Device

FX134, FX1234, FX3030 Problem and Solutions

100C Air Compressor Kit

Engineering World Health Youth EWH Design Projects That Matter

All-in-one trim tab control system. Installation & User's Guide For Electric Trim Tab Systems

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ATOC Meteorological Tower (6 meter-4 level) Guide

INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

FILTERING ELECTRICAL INTERFERENCE

User s Manual. Copyright 2014 Trick Technologies Oy

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Shocker Sport TM Manual. Includes: Shocker Sport 4X4 TM and Shocker Sport Turbo TM

12 Volt Inflator. Operator s Manual. Model: ICC12F, ICC12FC, ICC12FCN, ICC12FCM, ICC12N

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

CP-Gun Diver-held probe Operation manual

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

This is the Quick Start Guide for the Optibike Pioneer Allroad electric bicycle. The Guide provides for basic information required to ride the

Technical Data. Dimensions

IBU3 Manual Addendum 1

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

! Warning, refer to accompanying documents.

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device

RAM Operation Manual

FT500GF Dat e Code: 2 - FT500GF - - MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

Sideshift SS230 Installation on a 2006 Bayliner 265SB

Installation, Compensation and Maintenance Instructions for. RITCHIE Compasses. Made In U.S.A

PNEUMATIC PRESSURE CONTROLLERS

SILENTAIRE TECHNOLOGY

Paddle Bar Replacement

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Installation and service should be performed by a qualified service professional.

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Sensoric 4-20 ma Transmitter Board Operation Manual

VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No

Service Installation: 48 V Power Supply September 27, 2018 SI Written by BTA

Measuring wind speed and direction

AA100 Acoustic Actuator

SET-UP INSTRUCTIONS. Includes:» Lightning Strike with Ball Shagger Feeder» 6 Lightning Strike Balls» 6 Volt AC Adapter

PIRANHA I & 2 OPERATION GUIDE

Free Chlorine Sensor For additional information, please visit our website at

9A5N Solid State CW Paddle

How Bright Is Your Glow Stick? Measure It!

frequently asked questions

TRANSDUCER KIT 2 INSTALLATION INSTRUCTIONS

TRI- B A L L H I TC H OWNER S MANUAL

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Procedure Troubleshooting the Interconnect Cables

GEMS SENSORS & CONTROLS

Dissolved Oxygen Sensor

Transcription:

Micrio Tester for the Raymarine ST50, ST60, and ST60+ Wind Instruments. Rev 1.1 The Micrio Wind Tester allows quick and easy testing of the Raymarine ST50/ST60/ST60+ masthead wind instrument. The Micrio Wind Instrument Tester. The Raymarine wind sensors can fail for a number or reasons; lightning, water corrosion, or mechanical damage. Testing the masthead transducer is both difficult and tricky. First you must use a bosun s chair, climb the mast, or un-step the mast before you can get at the masthead sensor. After the masthead sensor is in hand you must perform a tricky analysis using voltmeters and power supplies. A slipped wire can destroy the sensitive circuits inside. The Micrio Wind Instrument Tester solves these problems. If you climb the mast you can test the masthead sensor while at the top of the mast. Simply plug the masthead instrument into the Micrio Tester and move the anemometer and the feather. The ultra-bright LED lights on the Tester will indicate the condition of the sensors inside the masthead instrument. We use the highest brightness LEDs so that they can be seen in daylight. Web: www.micrio.com contact: sales@micrio.com 1

Table of Contents. Using the Micrio Tester.... 3 Old style masthead wind instrument... 3 The Battery LED... 5 The Port and Starboard LEDs... 6 The Speed LED... 6 The connector on the masthead sensor.... 7 Maintenance Tip....7 Web: www.micrio.com contact: sales@micrio.com 2

Using the Micrio Tester. The Micrio Tester has a connector that will mate with the 5 pin connector on the Raymarine ST50, ST60, and ST50+ masthead instruments. Power is supplied by a 9 volt battery. There are 4 LED s to indicate the condition of the various circuits in the wind instrument. Power is controlled with an On/Off switch. To conserve the battery, the switch should be left off when not actually doing testing. Old style masthead wind instrument. The Micrio Tester is compatible with both the new and old style masthead instruments. The old style was used with the ST50 and ST60 wind instruments. The new style is used with the ST60+ wind instrument. Micrio Tester with new style masthead instrument. Web: www.micrio.com contact: sales@micrio.com 3

Micrio Tester with old style masthead instrument. Web: www.micrio.com contact: sales@micrio.com 4

The Battery LED. The red LED nearest the switch is labeled Battery. This LED indicates two things; the condition of the battery and will detect short circuits in the wind instrument. If the battery voltage drops below a usable level then the battery LED will go out. You should check this before climbing the mast. Climb the mast and remove the masthead wind speed/direction sensor by unscrewing the hand nut and pulling straight out on the arm. The sensor has a five pin connector that looks like this: The Masthead Sensor Connector The five male pins at the mast end of the sensor arm plug into the female connector on the tester. Turn the tester switch to on. The Micrio Tester has a current limiting circuit so that a short circuit in the wind instrument will not cause any further damage. If this circuit detects a short circuit then the LED will go out. In this case no further testing can be done. Web: www.micrio.com contact: sales@micrio.com 5

The Port and Starboard LEDs. The middle two LEDs are labeled port (red) and starboard (blue). They indicate the status of the wind direction sensor. As the wind direction feather is rotated the two LEDs will flash on and off. They will not be in unison; they will be at peak brightness 90 degrees from each other. As you rotate the feather one LED will be at it s brightest. As you continue to rotate the feather that LED will fade and the other one will become bright. Continuing, the first LED will fade out as the second LED decreases in brightness. This process will continue cycling as you rotate the feather around multiple times. It is this pattern that indicates proper operation. If one LED remains constantly bright or dim then the wind direction sensor circuit has failed. It is entirely possible that one LED will indicate proper operation and the other one will indicate failure. The terms port and starboard can be confusing in this context. These are the terms that Raymarine uses to describe the circuit so we also use them. The terms do not relate to the directions on a boat. They are used to describe signals that peak at 90 degrees from each other. The position of the feather with respect to the position of any signal peak is not important. The only important consideration is that they move cyclically as the feather is rotated. The alignment of the feather with the axis of the boat is done during the calibration process as described in the Raymarine literature. The Speed LED. The blue LED nearest the connector is labeled speed. This is used to test the anemometer. The anemometer sends pulses to the wind display. There are two pulses for each rotation. The speed LED shows these pulses. As you rotate the anemometer the speed LED should flash on and off. If the LED remains on or off then there is a failure. If the tester indicates that your masthead sensor is working properly, the problem is likely in the wind instrument or the wiring between the masthead sensor and the instrument. Web: www.micrio.com contact: sales@micrio.com 6

The connector on the masthead sensor. This is a view of the masthead transducer connector as you look at the pins. Maintenance Tip. The wind speed anemometer is on the bottom of the masthead transducer. The anemometer hub forms a cup where rain will collect. Raymarine anticipated this and put a small hole in the bottom of the cup to let the rain out. However, over time dirt also collects in this cup and will block the hole. During a rain storm the cup fills with water causing the small ball bearing on the anemometer shaft to run under water. Actually, by now it is muddy water. The dirt will enter the bearing and cause it to lock-up and fail. The solution is to clean this hole periodically. It might be a good idea to drill extra holes in some circumstances. Web: www.micrio.com contact: sales@micrio.com 7