Elcometer ISO Groove Depth Checker. Operating Instructions

Similar documents
Elcometer 123. Surface Profile Gauge. Operating Instructions

Elcometer Viscosity Cup. Operating Instructions

Elcometer 125. Surface Profile Comparator. Operating Instructions

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Elcometer 406L. Statistical Glossmeter. Operating Instructions

Pressure Calibrators. Series PC..., PM...

Elcometer 2300 Rotational Viscometers. elcometer.com

Pneumatic service kit Model CPG-KITP

STARLOG. Capacitive Water Depth Probe

Digital pressure gauge Model CPG500

User Manual PTW-DensiX. D / Di/Zi

WATERPROOF DIGITAL DEPTH GAGES

BD Cytopeia Fluidic Kit User s Guide

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

About us. Try us to trace your network!

Cadence Sensor W.I.N.D. User Manual

Digital Melting Point Apparatus

Peak Pressure Indicator MSI-3

BS ml Bottle Sampling Unit

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

We measure it. For gas and water installers. testo hpa. bar

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

130 SSP Soluble Salt Profiler

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Digital pressure gauge Model CPG500

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

SAUTER FK Version /2016 GB

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

PM105 PRESSURE METER USER S MANUAL

DFX II Series. Digital Force Gauge

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Pneumatic high-pressure controller Model CPC7000

General Accreditation Guidance. User checks and maintenance of laboratory balances

EC214 EC215 - EC215R Bench Conductivity Meters

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

Q2: Which instruments are necessary for monitoring the groundwater level?

12V MINI AIR COMPRESSOR

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Operating manual for the pressure transducer unit CCS 1000

Agilent Flowmeter ADM1000

VLI Visible Level Interface Operation & Maintenance Manual

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

HI 2314 HI 2315 HI 23151

12V Mini Air Compressor

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

Alpha Series. Main Features > Data displayed Selected speed r.p.m Selected spindle SP

Programmable pressure and temperature transmitters PTM/RS485

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Tensiometer For the measurement of surface and interfacial tension

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Tensiometer For the measurement of surface and interfacial tension

Getting to know your Sureshotgps micro V3

_ pressure transducers. User Manual

Courseware Sample F0

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Info Counting chamber (haemacytometer)

Pneumatic high-pressure controller Model CPC7000

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

TQC Bresle Chloride test 2008

Hydraulic hand test pump Models CPP700-H and CPP1000-H

Universal Gage. Multimar 844 T

Feltest AirSpeed/2 Instruction manual

Instrumentation & Data Acquisition Systems

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

Best Practice for Calibrating LTH Conductivity Instruments

Electronic gas volume corrector model DGVC-04

FPG8601 Force Balanced Piston Gauge

GMC-I Service GmbH Calibration Center

PRODUCT MANUAL. Diver Smart Interface Cable AS346

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Easy with a modular concept for future expansion

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

Programmable pressure and temperature transmitters PTM/RS485

TSE Blood Pressure Monitor Invasive series

safety Shut-Off Valve HON 721

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

AUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed

Depth Micrometer Page 205. Depth Gauge Page 208. Depth Gauge Accessories Page 218

Rotational Viscometers RP1 RP2

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

DRYING TIME RECORDER AB3600. IMPORTANT! Before taking this instrument in use we strongly advise you to read this manual carefully.

Hand-held pressure calibrator with integrated pump Model CPH6600

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

Transcription:

Elcometer 2060 English ISO Groove Depth Checker Operating Instructions

English The Elcometer 2060 ISO Groove Depth Checker has been tested in accordance with EU regulations governing electro-magnetic compliance and meets the required directives. Note: Gauge readings may be affected if the unit is operated within a radio frequency electromagnetic strength of greater than 3 V/m. is a registered trademark of Elcometer Instruments Ltd. All other trademarks acknowledged. Copyright Elcometer Instruments Ltd. 2006. All rights reserved. No part of this Document may be reproduced, transmitted, transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of Elcometer Instruments Ltd. Doc.No. TMA-0366 Issue 01 Text with Cover No: 19809

CONTENTS Section Page 1 About your depth checker........................................................ 2 2 Using your instrument........................................................... 4 3 Connecting to a PC.............................................................. 6 4 Maintenance................................................................... 6 5 Technical specification........................................................... 7 6 Accessories.................................................................... 7 7 Related equipment.............................................................. 8 1

Thank you for your purchase of this Elcometer 2060 ISO Groove Depth Checker. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply of inspection equipment for coatings and concrete. Our products cover all aspects of coating inspection, from development through application to post application inspection. The Elcometer 2060 is a world beating product. With the purchase of this gauge you now have access to the worldwide service and support network of Elcometer. For more information visit our website at www.elcometer.com 1 ABOUT YOUR DEPTH CHECKER The Elcometer 2060 ISO Groove Depth Checker is a precision instrument used to determine the accuracy of fineness of grind gauges in accordance with ISO standards. The instrument is set to zero and then placed on the fineness of grind gauge with the measuring needle resting on the bottom of the tapered groove. The depth of the groove at that point is shown on the display. Three readings are taken to provide an average depth at each graduation point along the tapered groove. The average depth must not differ by more than 3 µm (0.12 mils) from the nominal value at each graduation point. 1.1 STANDARDS The Elcometer 2060 ISO Groove Depth Checker can be used in accordance with the following standards: DIN EN ISO NF 21524 ISO 1524 2

1.2 WHAT THE BOX CONTAINS Elcometer 2060 ISO Groove Depth Checker Glass zero plate Storage case Calibration certificate Digital gauge instructions a Operating instructions The Elcometer 2060 ISO Groove Depth Checker is packed in a cardboard and foam package. Please ensure that this packaging is disposed of in an environmentally sensitive manner. Consult your local Environmental Authority for further guidance. To maximise the benefits of your new Elcometer 2060 ISO Groove Depth Checker please take some time to read these Operating Instructions. Do not hesitate to contact Elcometer or your Elcometer supplier if you have any questions. a. The instruction leaflet provided by the manufacturer of the digital gauge explains how to fit the battery and other features and functions of the digital gauge. 3

PRESET R TOL. 2 USING YOUR INSTRUMENT When using the instrument, take care not to damage the V-shaped edge of the rule or the surface of the glass zero plate. When taking a measurement, always hold the instrument by the plastic thermal insulation strips either side of the rule. 2.1 ZERO THE INSTRUMENT 1. Press the ON/OFF button to switch on the instrument. 2. Place the glass zero plate on a flat surface. 3. Hold the instrument on the glass plate perpendicular to the surface of the glass. 4. Press the ZERO button and check that the display shows 0.000 ZERO/ABS 0.000mm ON/OFF 4

R 2.2 TAKING A READING 1. Having set the instrument to zero, place the instrument on the surface of the fineness of grind gauge at the deepest end. 2. Align the measuring needle with a graduation mark on the scale of the fineness of grind gauge and the centre line of the groove (position B). 3. Check that the instrument is perpendicular to the surface of the fineness of grind gauge with the measuring needle touching the bottom of the tapered groove. 4. Record the depth of the groove from the display. 5. Repeat steps 1 to 4 above at each side of the groove (positions A and C). 6. Calculate the average of the three readings. When taking a reading, always hold the gauge here. If the average groove depth differs by more than 3 µm (0.12 mils) from the nominal value at the graduation point, the fineness of grind gauge is faulty and must be repaired or replaced. 7. Repeat steps 1 to 6 above at each graduation point of the fineness of grind gauge. 2.3 AFTER USE When you have finished taking readings, replace the instrument and glass zero plate in the protective case provided. ZERO/ABS A 0.030mm PRESET B Fineness of Grind Gauge TOL. C ON/OFF 5

3 CONNECTING TO A PC Your gauge can be connected to a PC to allow measurement data to be saved as it is collected. To connect to a PC, the following accessories will be required: Computer connection cable Dataputer 1CHM Multiplexer (Signal converter) DATA-XL software See Accessories on page 7 for ordering information. 4 MAINTENANCE The Elcometer 2060 ISO Groove Depth Checker is designed to give many years reliable service under normal operating and storage conditions. Regular calibration checks over the life of the gauge are a requirement of quality management procedures e.g. ISO 9000 and other standards. For checks and certification contact Elcometer or your local Elcometer supplier. Details of Elcometer offices around the world are given on the outside cover of these Operating Instructions. Alternatively visit the Elcometer website, www.elcometer.com 6

5 TECHNICAL SPECIFICATION Range: 0 mm to 6.48 mm (0" to 0.26") Resolution: 1 µm (0.04 mils) Accuracy: 3 µm (0.12 mils) Width of 60 mm (2.36") measuring edge: Battery: 1.5 V, SR44 button cell b 6 ACCESSORIES The following optional items are available from your local supplier or direct from Elcometer: Computer connection cable: KT002060P004 Dataputer 1CHM Multiplexer: M001CHM (Signal converter) DATA-XL software: M500DXL b. Batteries must be disposed of carefully to avoid environmental contamination. Please consult your local environmental authority for information on disposal in your region. Do not dispose of any batteries in fire. 7

7 RELATED EQUIPMENT In addition to the Elcometer 2060 ISO Groove Depth Checker, Elcometer produces a wide range of other equipment for measuring the physical characteristics of surface coatings. Users of the Elcometer 2060 may also benefit from the following Elcometer products: Elcometer 2000 Muller Laboratory Grinder Elcometer Fineness of Grind Gauges Elcometer Viscosity Cups and Rotational Viscometers For further information contact Elcometer, your local supplier, or visit our website at www.elcometer.com 8