NFOGM temadag

Similar documents
"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

Contribution to economic upstream gas metering with a dual-path ultrasonic metering solution

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

Calibrating and Monitoring MUSMs in Natural Gas Service

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI

Performance of an 8-path gas ultrasonic meter with and without flow conditioning. Dr Gregor Brown Caldon Ultrasonics Cameron

ULTRASONIC METER FLOW CALIBRATIONS CONSIDERATIONS AND BENIFITS. Joel Clancy

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

ULTRASONIC FLOW METER CALIBRATIONS CONSIDERATIONS AND BENIFITS American School of Gas Measurement Technology, September 2007.

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

ISO INTERNATIONAL STANDARD

Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246)

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Installation Effects on Ultrasonic Flow Meters for Liquids. Jan Drenthen - Krohne

Gas measurement for the real world

ULTRASONIC METER DIAGNOSTICS - BASIC. Dan Hackett. Daniel Flow Products

Evaluations on CO2 Rich Natural Gas. Jörg Wenzel - Sick

Oil and Gas Custody Transfer

The ERCB Directive 017 Overview

Fundamentals of Multipath Ultrasonic flow meters for Gas Measurement

Ultrasonic Meter Diagnostics - Advanced

Chapter 22 Testing Protocols

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Metering Code Gas TSO, measurement by connected party Effective from to the present

Vehicle-mounted meters, pump supplied

Vehicle- or rack-mounted liquefied gas meters, pump supplied

AN OVERVIEW AND UPDATE OF AGA 9 ULTRASONIC METERS. John Lansing. SICK, MIAHAK, Inc World Houston Parkway, Suite 180 Houston, Texas 77032

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

A new methodology for cost-benefit-risk analysis of oil metering station lay-outs

CUSTODY TRANSFER OF FLUIDS IN MALAYSIA

Ultrasonic Flowmeter USZ 08

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

Standard Operating Procedure Measuring & Testing Equipment

CUSTODY TRANSFER METERING

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

CORESTA RECOMMENDED METHOD N 6

ATION TITLE. Survey QC, Decision Making, and a Modest Proposal for Error Models. Marc Willerth, MagVAR

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Truck-mounted Mass Flow Metering for LPG Delivery

Flow Meter Diagnostics The Future of Measurement

International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages , 2015

Micro Motion 7812 Fiscal Gas Density Meter

Conversion of a large scale orifice measurement station to an ultrasonic measurement station with double capacity

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Study of Thermal Effect on Calibration of an Ultrasonic Flow Meter

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Micro Motion Pressure Drop Testing

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Technical Bulletin, Meter Factor Linearization

Measurement & Analytics Wet gas monitoring

National Occupational Standards For Measurement Processes Approved by UKCG May 2003

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Online data sheet FLOWSIC30 GAS FLOW METERS

NEW VERSAFLOW CORIOLIS

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

CALIBRATION AND TRACEABILITY: ITS IMPORTANCE IN THE GAS INDUSTRY

8:30 am 10:00 am Calculation of Petroleum Prover Quantity Calibration (COLM Ch. 12.4)

CALIBRATION PARAMETERS IMPACT ON ACCURACY OF NATURAL GAS ULTRASONIC METER

Oil And Gas Office Houston Fax Test Separator / Off-Shore Metering

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Cold-acclimatised pipelines

Flare Gas Measurement in B.C., Alberta, and Saskatchewan Using GE Ultrasonic Metering Technology

485 Annubar Primary Flow Element Installation Effects

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

United Kingdom of Great Britain and Northern Ireland

2013 Honeywell Users Group Europe, Middle East and Africa. Jürgen Wolff Advanced Gas Metering through Flow Profile Analysis

Selecting Flow Metering Sites And Evaluating Data

FAQs about Directive PNG017: Measurement Requirements for Oil and Gas Operations

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

GILMONT ACCUCAL FLOWMETERS

Review of ISO10723 Performance Test Frequency. By Anwar Sutan

MEASUREMENT GUIDELINES

Products Solutions Services. Gas Flow Measurement

Micro Motion 3098 Gas Specific Gravity Meter

This document is a preview generated by EVS

Recalibration of gas meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Turbine Flowmeters for Gas Applications

United Kingdom of Great Britain and Northern Ireland

Remote. Measurement Assurance. Why CEESmaRT? significantly in measurement

Turbine Flowmeters for Gas Applications

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Product Specification

The evolution of the Ex-proof flame path

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

General Accreditation Guidance. User checks and maintenance of laboratory balances

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Transcription:

NFOGM Temadag 19.3.2015 Challenges with calibration and adjustment of liquid USM`s Standards for Gas USM`s Author : Steinar Fosse, Norwegian Petroleum Directorate 1 NFOGM temadag 19.3.2015

Challenges with calibration and adjustment of liquid USM`s The challenge is mainly related to systems which is designed without a permanent proving device and the fact that calibration stations are not capable of reproducing the relevant flow rates. To compensate for this testing with various Re No (various liquids) are used to create a concept of dynamic similitude. Upstream pipe configuration and conditioning device should be as in the field. Normal way forward during testing: Testing of meter without correction Develop an algorithm to correct for viscous effects Retest the meter to validate the performance with correction. The documentation ofthe correction algorithms and the precise definition of the look up tables is important. It is for NPD/Oil company/vendor important that this baseline is correctly established and maintained at this level for the life of the meter. Each vendor has a vendor specific way to derive the corrections. Also confidentiality issues may be on the table. The look up table should have a resolution which makes error related to this less than 0,0X% of measured volume (in the measuring range). All meters for important services will require individual calibrations. 2 NFOGM temadag 19.3.2015

Challenges with calibration and adjustment of liquid USM`s A «check sum» follow up to keep track of any changes being done after calibration has taken place. We had the opportunity to test it in week 10. It did not work, the «check sum» was changed and no answers were available. Investigation ongoing. It is not so that the «Check sum» always will have to be the same, but any changes will have to be well documented. We do have to bear in mind that we always will increase the uncertainty of the measurement system when we design a system without a premanent proving device. A laboratory calibration will never be able to reproduce the actual values for P,T and flow conditions as you see in the field. A typical difference as we have experienced recently is between 0,3-0,4%. Both pulse and digital signal transmission possibility should be available on the meter. As this simplify the testing of the meter. A hollow plate (HP) + at least 5 D upstream is normally recommended as upstream configuration. 3 NFOGM temadag 19.3.2015

We do not like to look for anwers in obscure crystal spheres 4 NFOGM temadag 19.3.2015

We wish to be the Kings/Masters of the situation 5 NFOGM temadag 19.3.2015

Norway. Standards for Gas USM`s Our main reference should always be the Norwegian Petroleum Directorate Regulations relating to measurement of petroleum for fiscal purposes and for calculation ofco2 tax. We would like to think of this as «Hakkespettboken» which we remember from Huey, Luey and Dewey. The book that could give answer to all challenges. When it comes to Gas USM`s we will have to seek information also from other documents. First the new NORSOK-I-106, which was released in November 2014. It is also just giving brief information about the subject (section 7.3). We have to go to the international statandardsto dive deeper. Reference is made to NPD Measurement Regulationspreface last paragraph. (Reckognized standards and Industry standards) 6 NFOGM temadag 19.3.2015

7 NFOGM temadag 19.3.2015

Who`s next 8 NFOGM temadag 19.3.2015

9 NFOGM temadag 19.3.2015

10 NFOGM temadag 19.3.2015

Standards We wish to highlight some sections from BS 7965 (2013) as that is the newest and the least known standard in Norway. We do, however, not say that NPD express any preferences, we just mention some interesting paragraphs. 11 NFOGM temadag 19.3.2015

Klassifisering av målere 12 NFOGM temadag 19.3.2015

Classification of meters (ref table 2) 1) Custody transfer 2) Allocation 3) Utilities/Fuel gas 4) Process/flare gas We can consentrate on item 1 and 2. In BS it is included various notes on item 3 and 4. We can see that BS uses a zero to limit the possibility to achieve a better result by truncation of digits. Also ISO differensiate between category 1 and 2 and the presenly ongoing NPD regulatury update should do the same. 13 NFOGM temadag 19.3.2015

Thermowell installation and Insulation (5.4.5) Between 2D og 5D downstream of meter (as ISO) Intrusion depth on T-elements is mentioned. D/10 D/6.67. Isolation of pipes: «Where the insertion depth er larger than D/3,33 the meter run need not to be insulated. Where insertion depth is less than D/3,33 (or where surface mount technology is used) then the meter run should be insulated from the meter inlet until at least 1D downstream of the measurement point.» 14 NFOGM temadag 19.3.2015

Roughness in pipe criteria (5.4.2) Kr/D 10-4 Kr = (pipe wall uniform roughness) is approximately equal to Ra* ). The requirement is very much the same as in ISO 5167 (2003) Annex B. 15 NFOGM temadag 19.3.2015

7.6.3 Shift between calibrations For meters larger than 4 inch, a typical tolerance of ± 0,3% of FWME should be allowed between subsequent calibrations. For meters less than 4 inches the allowable shift is 0,5% of FWME. 16 NFOGM temadag 19.3.2015

17 NFOGM temadag 19.3.2015

VOS checks at laboratorium calibrations (Normally done) The maximum variation of the VOS between the different active paths (foot print) shall not exceed 0,5 m/s. The maximum deviation of the VOS average (active paths only) measured by the individual meter paths versus the VOS calculated by AGA 10 shall not exceed ± 0,2 %. Thank you for your attention! 18 NFOGM temadag 19.3.2015

References Regulations relating to measurement of petroleum for fiscal purposes and for calcultations of CO2 tax (NPD) ISO 17089-1: Measurement of fluid flow in closed conduits Ultrasonic meters for gas (2010) AGA Report No. 9: Measurement of Gas by Multipath Ultrasonic Meters (2007) BS 7965: Guide to the selection, operation and calibration ofdiagonal path transit time ultrasonic flowmeters for industrial gas applications (2013) Krohne: Technical presentation, Stavanger 27.11.15 Krohne: Technical information CEESI/NMi USM/Coriolis Seminar March 2014. Terry Cousins: The Reynolds Number corrections of Liquid Ultrasonic Meters and Coriolis Meters. NSFMW-2014: Terry Cousins: Is linearisation safe for custody transfer meters? NEL: South East Asia Hydrocarbon Flow measurement Workshop 2008: Brown/Cousins/Augenstein: Important considerations for traceable calibration of liquid ultrasonic meters NSFMW- 2013: Kalivoda/Smith/Gailey: Dynamic Testing 19 NFOGM temadag 19.3.2015