Stainless Steel 142 mm Filter Holder YY

Similar documents
Dispensing Pressure Vessels

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

Model 2000 High-performance Ultrafiltration Cell

RK LEL Sample Draw Aspirator Adapter Operator s Manual

FloWash. Industrial Filter Cart

Multi-Probe Sampling System User Guide & Manual

Integrity Testing LifeASSURE BDA020, BGA020 and BNA020 Series Filter Cartridges

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

ZHE+ Zero Headspace Extractor Operation & Instruction Manual

Agilent 1290 Infinity Pump Head Maintenance

Stirred Ultrafiltration Cells

Table of Contents - Chemdyne Filters

Stirred Ultrafiltration Cells Models 8003, 8010, 8050, 8200, User Guide

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

GILMONT ACCUCAL FLOWMETERS

Solvent Resistant Stirred Cells for Ultrafiltration and Filtration Applications

Table of Contents - Ultradyne Filters

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Geotech 1.66 Reclaimer

Types S100K and S102K Pressure Regulators

EQUIPMENT Operation Manual

BS Series Basket Strainer

Assembly and Installation Procedures

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation Instructions

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Pressure Injection Cell Operator s Manual

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Table of Contents - ALpHA Filters

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

CF-SERIES HIGH FLOW REGULATORS

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Geotech 1.66 Auto-Reclaimer

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Geotech 1.66 Auto-Reclaimer Installation and Operation

Table of Contents - Protec Filters

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

Type R622 Pressure Reducing Regulator

64 Series Pressure Reducing Regulators

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Masoneilan* 78 Model Air Filter Regulator

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

G7S Hand Pump Owner s Manual

Freedom8 ShoeBox Compressor Manual

MEGR-1912 Instruction Manual

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

GREIG FILTERS, INC. OPERATION MANUAL

Model ASSEMBLY and OPERATING INSTRUCTIONS

AND OPERATION INSTRUCTIONS

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

MODELS 1500, 1520, 1530, 1560

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Cocoa Patio Pond with Lit Spillway

TITAN FLOW CONTROL, INC.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

1805 Series Relief Valves

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Vessel Installation and Operating Manual

Alkylphosphines. Storage and Handling Recommendations

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Installation and Operating Manual

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

Choosing the right miniature instrument and control valve is a snap

Durham Geo-Slope Indicator S-510 Triaxial Cell

Installation, Operation, and Maintenance Manual

Table of Contents - EverLUX Filters

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

MEGR-1627 Instruction Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Back Pressure Regulator

OPERATING INSTRUCTIONS

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Instructions Parts List

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

RD(H)20/25 Pressure-Reducing Regulator User Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Medical Gas Control Panel

Operating Manual. Appa. Models LP/HP-A4K & LP/HP-A445K Air Quality Test Kits Manual No. AIRTST01 (Rev 7 October 2008)

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

Installation, Operation and Maintenance Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model Series 62 Constant Differential Relay

Transcription:

Stainless Steel 142 mm Filter Holder YY30 142 36

Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. 2004 MILLIPORE CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA. ALL RIGHTS RESERVED. THIS BOOK OR PARTS THEREOF MAY NOT BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF THE PUBLISHERS. M10192, Rev. C, 10/04 Millipore and Milli-Q are registered trademarks of Millipore Corporation. Buna is a trademark of Pittway Corporation. Kraft is a trademark of the International Paper Company, Kraft Paper Division. Teflon and Tyvek are trademarks of E.I. DuPont de Nemours, Inc. Triton is a trademark of Rohm and Haas, Inc.

Introduction This document describes how to use the Stainless Steel 142 mm Filter Holder, including details on: Function Assembly Specifications Function of the Holder You use the holder to sterilize gases or liquids by pressure filtration through a 142 mm diameter disk filter. You can optionally place a prefilter in the same holder upstream of the membrane filter to increase throughput by eliminating filter clogging.

2 www.millipore.com Diagram and Parts of the Holder for Assembly 1 3 5 6 8 7 12 1 2 4 7 9 10 11 4 3 13 Diagram Part Catalogue Number 1 Adapter, 1 1/2 TC to 14 mm (9/16 ) I.D. YY20 04076 2 Handwheel knob (3 required) YY22 142 57 3 Gasket, silicone 1 1/2 TC YY20 040 55 4 Clamp, 1 1/2 TC (2 required) YY20 040 45 5 Vent/relief valve, 9 bar (125 psig) YY30 293 66 6 Inlet plate, including inlet flow detector YY30 293 07 7 O-ring, PTFE/silicone YY22 142 53/YY22 142 65

Stainless Steel 142 mm Filter Holder User Guide 3 Diagram and Parts of the Holder for Assembly, continued Diagram Part Catalogue Number 8 Filter support screen, PTFE faced YY30 142 34 9 Underdrain support YY22 142 58 10 Outlet plate 11 Handwheel stud YY22 142 70 12 Leg bushing and socket screw YY22 142 55 13 Legs with caps YY22 142 51 Preparing the Holder This section includes details on: Cleaning the holder Loading the filter Autoclaving the holder Bubble point testing the holder Cleaning the Holder Before using the holder wash all components with a sponge, hot water, and nonabrasive cleanser. Rinse the components thoroughly with deionized, sterile, or Milli-Q water and air dry. Do not wipe the components dry with paper or cloth. Fibers and lint left on surfaces can generate electrostatic forces that attract more dirt.

4 www.millipore.com Loading the Filter 1. Attach inlet and outlet hoses to the filter holder. 2. Using smooth tip forceps, center a Millipore filter on the support screen. If you are using a prefilter, center it on the membrane filter. NOTE: For reverse-flow surge protection, install a support screen upstream. 3. Tighten the handwheels the same number of turns all the way around to obtain a uniform membrane seal. If you plan to autoclave the unit, do not tighten the handwheels yet. Instead, see the Autoclaving the Holder section. Autoclaving the Holder 1. Wrap the unit and ends of the inlet and outlet hoses with Kraft paper or Tyvek substrate. 2. Autoclave the assembly with the filter in place for 35 45 minutes at 121 C (250 F) and 15 psig (pounds per square inch gauge). NOTE: All internal surfaces must be dry prior to autoclaving. 3. Tighten the handwheel bolts by turning them the same number of times all the way around after the unit cools.

Stainless Steel 142 mm Filter Holder User Guide 5 Integrity Testing the Holder Follow the steps in these sections to test the filter assembly for leaks. Equipment Set Up for Integrity Test and Filtering To perform the bubble point integrity test and filter your sample, set up your equipment as shown: Inlet Hose Compressed Nitrogen or Air Valve E Gauge Valve C Outlet Hose Vent Valve A Valve B Vent Pressure Vessel Containing Unfiltered Liquid Outlet Tube D Receptacle

6 www.millipore.com Integrity Test 1. Open the filter holder vent valve A. 2. Close valve B to the receptacle. 3. Open valve C to let liquid flow through the holder slowly and wet the filter thoroughly. Open valve B. 4. Close vent valve A. Liquid will continue to flow. 5. Close liquid supply valve C. Open valve E and apply low pressure to force out residual liquid and saturate the filter. 6. Increase the pressure slowly and observe outlet tube D for continuous bubbling when the liquid stops flowing. If continuous bubbling occurs at a pressure equal to the bubble point value for the filter pore size, the test is a success. If bubbling occurs at a pressure less than the bubble point value, the test has failed. NOTE: See the Bubble Point Values for Millipore Membrane Filters section. If the test is successful: The filter is intact and the holder is tight. Disconnect the compressed air source and proceed to the next section. Filtering Your Sample. If the test is not successful: Repeat the test, ensuring that the filter is sufficiently wetted. If the repeat test fails, disassemble the unit and check for dirt on the O-ring or damage to the O-ring or filter. Reinsert the O-ring. Then repeat the Loading the Filter, Autoclaving the Holder, and Bubble Point Set Up and Test sections.

Stainless Steel 142 mm Filter Holder User Guide 7 Filtering Your Sample 1. Set up your equipment as shown in the Equipment Set Up for Bubble Point Test and Filtering section. Open vent valve A. Close outlet valve B. Unfiltered liquid will begin to flow. 2. Just when the flow is steady, close valve A. 3. Open outlet valve B, and increase the flow. For optimum flow rate, see the Flow Rates for Water and Methanol section. 4. Disconnect the inlet and outlet hoses and proceed to the next section, Maintenance of the Holder when filtration is complete. Maintenance of the Holder 1. Disassemble and wash all components with a sponge, hot water, and non-alkaline, nonabrasive cleanser. CAUTION: Do not use abrasive materials which can harm components. 2. Rinse components thoroughly with clean, laboratory-grade or Milli-Q water and then air dry. CAUTION: Do not wipe the components dry with paper or cloth. Fibers and lint left on surfaces can generate electrostatic forces that attract more dirt.

8 www.millipore.com Product Specifications Item Specifications Materials 316 stainless steel holder; anodized aluminum legs; Teflon O-rings; silicone gaskets Filter diameter 142 mm Filtration area Approximately 127 cm 2 Prefilter diameter 124 mm Dimensions 184 mm (7 1/4 in.) diameter; 270 mm (10 5/8 in.) height Pressure 14.06 kg/cm 2 (200 psig) inlet; 7.03 kg/cm 2 (100 psi) differential Bubble Point Values for Millipore Membrane Filters Water Methanol Filter GS HA RA SM FG FH FA PSI 50 30 11 6 13 7 3 BAR 3.52 2.11 0.77 0.42 0.91 0.49 0.21

Stainless Steel 142 mm Filter Holder User Guide 9 Initial Flow Rates for Water and Methanol This section shows the initial flow rates for water and methanol at 10 psi (.7 bar) differential pressure and 20 C (68 F). Filter Type GS HA RA SM FG FH FA Pore Size (µm) 0.22 0.45 1.2 5.0 0.2 0.5 1.0 Liters per minute Water Methanol (L/min) 1.5 3.7 15.2 19.6 1.5 3.9 8.1 Initial Flow Rates for Air This section shows standard cubic feet per minute (SCFM) of air flow at specified standard conditions of temperature and pressure: 1.0 atm (14.7 psi) and 20 C (68 F). Filter Type GS HA RA SM FG FH FA Pore Size (µm) 0.22 0.45 1.2 5.0 0.2 0.5 1.0 SCFM 6.4 11.5 27.0 30.4 9.2 18.4 24.7 Technical Assistance For more information, contact the Millipore office nearest you. In the U.S., call 1-800-MILLIPORE (1-800-645-5476). Outside the U.S., see your Millipore catalogue for the phone number of the office nearest you or go to our web site at www.millipore.com/offices for up-to-date worldwide contact information. You can also visit the tech service page on our web site at www.millipore.com/techservice.

Standard Warranty Millipore Corporation ( Millipore ) warrants its products will meet their applicable published specifications when used in accordance with their applicable instructions for a period of one year from shipment of the products. MILLIPORE MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED. THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The warranty provided herein and the data, specifications and descriptions of Millipore products appearing in Millipore s published catalogues and product literature may not be altered except by express written agreement signed by an officer of Millipore. Representations, oral or written, which are inconsistent with this warranty or such publications are not authorized and if given, should not be relied upon. In the event of a breach of the foregoing warranty, Millipore s sole obligation shall be to repair or replace, at its option, the applicable product or part thereof, provided the customer notifies Millipore promptly of any such breach. If after exercising reasonable efforts, Millipore is unable to repair or replace the product or part, then Millipore shall refund to the customer all monies paid for such applicable product or part. MILLI- PORE SHALL NOT BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR ANY OTHER INDIRECT DAMAGES RESULTING FROM ECONOMIC LOSS OR PROPERTY DAMAGE SUSTAINED BY ANY CUSTOMER FROM THE USE OF ITS PRODUCTS.