Instructions to User

Fingertip Pulse Oximeter

Instructions to User

Instructions to User

.$2;,)*3/6$ USER MANUAL

Instruction Manual CMS-50DL

Warning: Keep away from small children; -30 C +70 C User Guide GO2 % SpO2

WARNING: EXPLOSION HAZARD

Instruction Manual CMS-50DL

Gebrauchsanweisung Mode d' emploi Instrucciones para el uso Istruzioni per l'uso Инструкции по зксплуатации. ri-fox N

Finger Pulse Oximeter. User Manual. Innovo Medical Stafford Centre Drive Suite B Stafford, TX

Oxygen Saturation Monitors & Pulse Oximetry

PULSOX -2 INSTRUCTION MANUAL

Oxygen Saturation Monitor PULSOX -2. Instruction Manual

Instructions to User

Instruction for Use. Mobile Pulse Oximeter. (File No.: IFU-MPO) Version: 01. Zhejiang Medzone Medical Equipment Co.,Ltd

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

OXYGEN SATURATION MONITOR PULSOX Instruction Manual. This instrument must be used according to the instructions of the doctor.

Rad-57 Pulse CO-Oximeter

Sensor. Directions For Use

Digital Blood Pressure Monitor. Model UA-787

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Regalia Oxygen Concentrator

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

Semi-Automatic Blood Pressure Monitor with Memory

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Instruction Manual for Configura Cushionair Portable Pump

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

Notes Before Use...2 Notes on charging your watch...2. Your Watch...4 Name of Components...6 About the crown...7

Infrared Thermometer Instruction manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Accutorr. Quick Reference Guide

1. Features CONTENTS. 3English

1. Features CONTENTS. English

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

User Manual Article number: I

34282/ Fabbricante Manufacturer. Gima S.p.A. - Via Marconi, Gessate (MI) Italy Made in P.R.C.

Digital Melting Point Apparatus

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Operating Instructions Part No

VER: A00. Model No:BA2010

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Arena by Oregon Scientific

KNOW YOUR EQUIPMENT: Pulse oximeter Verghese Cherian Associate Professor of Anesthesiology Hershey Medical Center

Infrared Ear and Head Thermometer Instruction Manual

Norrsken Family Booklet

Sports Wrist Digital Blood Pressure Monitor Item #

TD-3140 Blood Pressure Monitor. Owner s Manual

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

CITIZEN QUARTZ TRAINING TIMER. Model No. ME4xxx Cal. No. D320 INSTRUCTION MANUAL CTZ-B8020

COPYRIGHT Ramsey Medical, Inc.

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Blood Parameter Monitoring System 550

1. Features. 3English

HemoCue Hb Procedure Template

This is an analog solar-powered watch that is equipped with a solar cell incorporated in its face to convert solar energy into electricity.

CONTENTS A. BEFORE USING B. SETTING THE TIME C. FUNCTIONS OF SOLAR POWERED WATCH

CONTENTS 1. Features 7. Solar-Powered Watch Handling Precautions 2. Before Using 3. Names of Components

REF CH-302B IDENTIFICATION OF PARTS

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

User Manual PTW-DensiX. D / Di/Zi

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Digital Ear Thermometer

TME CH LM R L A 7 T- M M L-T CHR ALM TME

Oxicom 2100 INSTRUCTION MANUAL

GE Measurement & Control

U S ER S AN D M AI N TEN AN CE M AN U AL

VIDEO TUTORIAL: greatergoods.com/0605

Operating Manual Body fat balance

INTEGRA E-Z INSTRUCTION MANUAL

TD-3140 Blood Pressure Monitor. Owner s Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Section 2: Using the Invasive Blood Pressure Module - An Introduction

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Vapotherm Q50 Compressor. Instructions for Use

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

CONTENTS A. BEFORE USING B. SETTING THE TIME C. FUNCTIONS OF SOLAR POWERED WATCH

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

In Vivo Scientific, LLC INSTRUCTION MANUAL

PIRANHA I & 2 OPERATION GUIDE

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Safety precautions (IMPORTANT)

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

WELCOME TO THE REVOLUTION

Transcription:

Model: PC-60B5

TABLE OF CONTENTS 1 Overview...1 1.1 Appearance...1 1.2 Name and Model...2 1.3 Intended Use...2 1.4 Feature List...2 1.5 Important Acroynms...2 2 Battery Installation...3 3 Quick Guide to Operation...4 4 Display Screen...5 5 Instructions for Operation...7 6 Technical Specifications...8 7 Alarms...9 8 Classifications...10 9 Accessories...10 10 Repair and Maintenance...11 10.1 Maintenance...11 10.2 Cleaning and Disinfecting...11 11 Troubleshooting...13 Appendix...14 A. Key of Symbols...14 B. Common Knowledge...15 C. Notes...17 D. Cautions...18 E. Warnings...19

OVERVIEW 1.1 Appearance Display Key Rubber Cushions Display Screen Figure 1: Front View Nameplate Battery Cover Hanging Hole Figure 2: Back View 1

1.2 Name and Model Name: Pulse Oximeter Model: PC-60B5 1.3 Intended Use This Oximeter is intended for measuring the pulse rate and functional oxygen saturation (SpO 2 ) through user s finger. It is solely for use of spot-checking the pulse rate and SpO 2 in the environment including exercise, high altitude sport and aviation activity. 1.4 Feature List Dual Color LCD with Backlight Measures SpO 2 & Pulse Rate Displays Waveform & Perfusion Index Auto On/Off Alarm Low Voltage Indicator Multi-Directional Display 1.5 Important Acronyms SpO 2 : Pulse Oxygen Saturation BPM: Beats Per Minute PR: Pulse Rate PI: Perfusion Index 2

2 Battery Installation 1 2 Figure 3: Battery Installation Step 1: (Refer to Figure 3) Insert two (2) AAA size batteries into the battery compartment. Step 2: Slide the battery cover into place. Note: To ensure the device works properly, please make sure the batteries are installed correctly. 3

3 Quick Guide to Operation Step 1: Open the clip and put finger into the rubber cushions of the clip (make sure the finger is in the correct position), and then clip the finger. Step 2: Wait about 2 seconds, the oximeter will power on automatically and start to measure. To change the display direction by 180 degrees, press the button. Display direction change shows bar-graph, pulse rate symbol and waveform. Press the button again to flip the display back. (see figures 5 & 7) To shift the displayed readings between PR and PI, press and hold the button. (see figures 6 & 7) Step 3: Remove your finger, the oximeter will power off automatically. 4

4 Display Screen For PC -60B5 oximeter, SpO 2 and PR symbols are imprinted on the front panel and its corresponding value displays on display screen below the symbol. (see figure 4) Note : the two figures both show that SpO 2 value is 99% and PR value is 86bpm. SpO 2 PR Figure 4 Pulse Bar Waveform Figure 5 Note : the two figures both show that SpO 2 value is 99% and PI value is 7.5%. SpO 2 PI Pulse Bar Waveform Figure 6 Figure 7 5

Waveform Display The waveform on the pulse oximeter is the plethysmogram which helps to understand if the readings are reliable. Normally, a smooth and regular waveform would represent good signal quality and therefore a more reliable reading. In comparison, an unsmooth or irregular waveform would represent poor signal quality with motion artifact and therefore would produce readings that may be inaccurate or unreliable. PI Display Perfusion Index (PI) indicates the bloodflow perfusion under the measuring site and also represents the pulse strength for determination of SpO 2 and PR. It is recommended to select a measuring site with a higher PI value, such as a fingertip, to obtain higher pulse strength. The pulse oximeter may reach the declared accuracy while the PI value is as low as 0.6%. 6

5 Instructions for Operation The finger should be put in properly and correctly. Do not shake the finger. Keep at ease during measurement. Do not put wet finger directly into sensor. Avoid placing the device on the same limb which is wrapped with a cuff for blood pressure measurement or during venous infusion. Do not let anything block the emitting light from device. Vigorous exercise or strong electro-magnetic interference may affect the measuring accuracy. Using enamel or other makeup on the fingernail may affect the accuracy of measurement. If the first reading has irregular or unsmooth waveforms, then it is likely inaccurate. A more reliable reading may be achieved by waiting for a short period of time or restarting the device. 7

6 Technical Specifications Net Weight 60g (including batteries) Dimensions Power Supply Transducer SpO 2 Measurement Range SpO 2 Measuring Accuracy 1 Pulse Rate (PR) Measurement Range Pulse Rate Accuracy 66 mm (L) 36 mm (W) 33 mm (H) 2 x LR03 (AAA) Akaline Batteries Dual-wavelength LED sensor Wavelength: Red Light: 663nm, Infrared light: 890nm 50-90% Not greater than 3% for SpO2 range from 70-100% 30bpm-240bpm ±2bpm or ±2% (whichever is greater) Perfusion Index (PI) 0-20% Display Range 2 Operating Temp 5 C to 40 C Operating Humidity 30% to 80% Operating Altitude Warranty up to 4,000 meters 2 years 1 Accuracy defined as root-mean-square value of deviation according to ISO 9919. 2 Performance Under Low PI Condition - The accuracy of the SpO 2 and PR measurement still meet the precision described above when the PI is as low as 0.6%. 8

7 Alarms Preset Alarm Limits SPO 2 alarm: Lower limit: 90% PR alarm: Upper limit: 120bpm Lower limit: 50bpm Audible & Visual Alarm Function During measurement, if the SpO 2 value or PR value exceeds the preset alarm limit, the device will alarm automatically and the value which exceeds the limit will flash on the screen while the buzzer beeps. 9

8 Classifications Protection against electric shock: Internally powered equipment. Degree of protection against electric shock: Type BF applied parts. Degree of protection against harmful entrance of liquids: Ordinary equipment without protection against entrance of water. Electro-Magnetic Compatibility: Group I, Class B 9 Accessories Lanyard Two (2) AAA batteries Carrying pouch User Manual Quality Certificate Note: The accessories are subject to change. Detailed items and quantity see the packing list. Additional accessories may be purchased by contacting Quest Products, Inc. at 800.650.0113 or service@questproductsinc.com. 10

10 Repair and Maintenance 10.1 Maintenance The service life (not a warranty) of this device is 5 years. In order to ensure its long service life, please pay attention to the maintenance. Change the batteries when the low-voltage indicator lights up. Clean the surface of the device before using. Wipe the device with wet cloth first, and then let it air dry or wipe it dry. Remove the batteries if the oximeter will not be used for a long time. The recommended storage environment of the device: Ambient temperature: -20ºC ~60ºC, relative humidity 10%~95%, atmospheric pressure: 50kPa~107.4kPa. The oximeter is calibrated in the factory before sale, there is no need to calibrate it during its life cycle. However, if it is necessary to verify its accuracy routinely, the user can conduct the verification by means of a SpO 2 simulator, or it can be done by a local third party tester (see page 20). 11

10.2 Cleaning and Disinfecting Instruction Surface-clean sensor (on upper and lower rubber cushions within the finger clip) with a soft cloth by wetting with a solution such as 75% isopropyl alcohol then surface-clean with a cloth saturated with clean water and dry with a clean, soft cloth. Caution: Do not sterilize by irradiation or steaming method Do not use the device if it is damaged. High-pressure sterilization or disinfection cannot be used on the device. Do not immerse the device in liquid. It is recommended that the device should be kept in a dry environment. Humidity may reduce the life of the device, or even damage it. 12

11 Troubleshooting Trouble SpO 2 and PR display instable Device will not turn on Possible Reason 1. The finger is not placed far enough inside. 2. The finger is shaking or the user is moving. 1. The batteries are drained or almost drained. 2. The batteries are not inserted properly. 3. The device is malfunctioning. Solution 1. Place the finger correctly inside and try again. 2. Calm the user. 1. Change batteries. 2. Reinstall batteries. 3. Contact service provider (see page 19) No display 1. The device will power off automatically when it gets no signal for 8 seconds. 2. The batteries are almost drained. 1. Normal. 2. Change batteries. 13

Appendix A. Key of Symbols Symbol %SpO 2 Description Pulse oxygen saturation Pulse rate (beats per minute) PI% Perfusion Index (%) Pulse intensity bargraph Low battery voltage SN Serial number Date of manufacture With Type BF applied part Warning See User Manual Disposal of this device according to WEEE regulations 14

Appendix B. Common Knowledge Meaning of SpO 2 SpO 2 is the saturation percentage of oxygen in the blood, so called O 2 concentration in the blood; it is defined by the percentage of oxyhemoglobin (HbO 2 ) in the total hemoglobin of the arterial blood. SpO 2 is an important physiological parameter to reflect the respiration function; it is calculated by the following method: SpO 2 = HbO 2 / (HbO 2 +Hb) 100% HbO 2 are the oxyhemoglobins (oxygenized hemoglobin), Hb are those hemoglobins which release oxygen. Meaning of PI Perfusion Index or PI is the ratio of the pulsatile blood flow to the non-pulsatile static blood flow in a patient s peripheral tissue, such as finger tip, toe, or ear lobe. Perfusion index is an indication of the pulse strength at the sensor site. The PI s values range from 0.2% for very very weak pulse to 20% for extremely strong pulse. The perfusion index varies depending on patients, physiological conditions, and monitoring sites. Because of this variability, each patient should establish his own normal perfusion index for a given location and use this for monitoring purposes. PI is also a good indicator of the reliability of the pulse 15

oximeter reading. For most pulse oximeters for general use, the reading is unreliable or unavailable if PI is at or below 0.4%. Principle of Measurement Based on Lamber-Beer law, the light absorbance of a given substance is directly proportional with its density or concentration. When the light with certain wavelength emits on human tissue, the measured intensity of light after absorption, reflecting and attenuation in tissue can reflect the structure character of the tissue by which the light passes. Due to that oxygenated hemoglobin (HbO 2 ) and deoxygenated hemoglobin (Hb) have different absorption character in the spectrum range from red to infrared light (600nm~1000nm wavelength), by using these characteristics, SpO 2 can be determined. SpO 2 measured by this oximeter is the functional oxygen saturation -- a percentage of the hemoglobin that can transport oxygen. In contrast, hemoximeters report fractional oxygen saturation a percentage of all measured hemoglobin, including dysfunctional hemoglobin, such as carboxyhemoglobin or metahemoglobin. Practical application of oximeters Pulse Rate and SpO 2 level are important physiological parameters to review the reaction of body during physical activity, so instant spot-checking pulse rate and SpO 2 by an oximeter is a popular solution in any environment including exercise, high altitude sport and 16

air travel. The medical precondition can be monitored in a timely manner by the measurement of PR & SpO 2, it will allow finding the hypoxia status earlier, thereby preventing or reducing the risk of occurance of hypoxemia effectively. Factors affecting SpO 2 measuring accuracy Intravascular dyes such as indocyanine green or methylene blue Exposure to excessive illumination, such as surgical lamps, bilirubin lamps, fluorescent lights, infrared heating lamps, or direct sunlight Vascular dyes or external used color-up product such as nail enamel or color skin care Excessive user movement Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line Exposure to the chamber with High pressure oxygen There is an arterial occlusion proximal to the sensor Blood vessel contraction caused by peripheral vessel hyperkinesias or body temperature decreasing 17

Appendix C. Notes The contents contained in this manual are subject to change without notice. Information furnished by our company is believed to be accurate and reliable. However, no responsibility is assumed by us for its use, or any infringements of patents or other rights of third parties that may result from its use. Instructions for Safe Operations Check the device to make sure that there is no visible damage that may affect user s safety or measurement performance with regard to sensors and clips. It is recommended that the device should be inspected minimally once a week. When there is obvious damage, stop using the device. Necessary maintenance must be performed only by qualified service technicians. Users are not permitted to maintain it by themselves. (see page 20) The oximeter cannot be used together with devices not specified in User Manual. D. Cautions Explosive hazard DO NOT use the oximeter in environment with inflammable gas such as some ignitable anesthetic agents. DO NOT use the oximeter while the testee is under MRI or CT scanning. 18

E. Warnings An uncomfortable or painful feeling may appear if using the oximeter continuously on the same place for a long time, especially for poor microcirculation users. It is recommended that the oximeter should not be applied to the same location for longer than 2 hours. If any abnormal condition is found, please change the position of oximeter. DO NOT clip this device on edema or tender tissue. The light (the infrared light is invisible) emitted from the device is harmful to the eyes, so service technician or testee should not stare at the light. The local law must be followed when disposing of the device. Attentions Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high temperature and moisture. The device should be kept out of the reach of children. If the oximeter gets wet, please stop using it and do not resume operation until it is dry. When it is carried from a cold environment to a warm and humid environment, please do not use it immediately. DO NOT operate the button on the front panel with sharp materials. 19

DO NOT use high temperature or high pressure steam disinfection on the oximeter. Refer to Section 8 for instructions on cleaning and disinfection. Declaration of Conformity The manufacturer hereby declares that this device complies with the following standards: IEC 60601-1 ISO 9919 For servicing or product related questions, please contact: Quest Products, Inc. 191 Ambrogio Drive Gurnee, IL 60031 USA Tel: 800.650.0113 service@questproductsinc.com www.questproductsinc.com 20