TYPE APPROVAL CERTIFICATE

Similar documents
TYPE APPROVAL CERTIFICATE

N.I.V. Bluestar Plus

TYPE APPROVAL CERTIFICATE

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

SLOP RECEPTION AND PROCESSING FACILITIES

Assessment of Ships and Managers for the Acceptance of Extended Interval Between Bottom Surveys in Dry-Dock

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

Electrical Shore Connections

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008

RULES FOR CLASSIFICATION Yachts. Part 5 Ship types Chapter 3 Passenger Yachts. Edition December 2015 DNV GL AS

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

RULES FOR CLASSIFICATION. Yachts. Part 5 Ship types Chapter 3 Passenger yachts. Edition October 2016 DNV GL AS

Pressure controls for hydro carbons, zone II applications, Type KPE

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

LNG BOIL-OFF RE-LIQUEFACTION PLANTS AND GAS COMBUSTION UNITS

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Metal Expansion Joints. System solutions for reliable connections in plant engineering and construction.

Pressure transmitters EMP 2

Sockets. terminations

CMC Series Moulded Case Circuit Breaker Cielo Electric

Further technical information is available on

Guidelines to the standard IEC60601

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

X2 Metallized Polypropylene Film Capacitor JFV

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

OFFSHORE. Trasfor OFFSHORE

HYDRAULIC CYLINDERS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2009

Operating Instructions

To: Relevant departments of CCS Headquarters, Plan approval centers, CCS surveyors, relevant shipyards, designers and shipping companies

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES

Centriflow Plus High-pressure plug fan - Technical Data

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

Operating Manual FSV, FSÖV, SSVF

Manual Power relay SR853

TYPE APPROVAL CERTIFICATE

IECEx Certificate of Conformity

Differential pressure controls, Type MP 54, 55 and 55A

The SAG type flat, rubber-steel, balance ropes

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

Tightness controls TC 1 3 and TC 4

Part 7 Fleet in service Chapter 2 Inclining test and light weight check

Pressure controls, differential pressure controls type RT

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

BSI BSI 5200 THE NEW CAST 60 FITTINGS AN EASY ASSEMBLY A KNOWN PRODUCT, SAFE AND RELIABLE AVAILABLE IN CARBON AND STAINLESS STEEL

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Pressure switch KP-E. Data sheet

Process Filtration From Pure to Sterile

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

SITRANS P measuring instruments for pressure

TERMINAL BLOCK SUMMARY

Mobarakeh Steel Company (MSC) Can Iranian slabs & HRC support SE Asian steel industries?

Service Calibration are you doing it properly?

Junction Boxes Series 8118

Part 4 Machinery and systems Chapter 6 Piping systems, pumps and compressors

Certificate of compliance

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Certificate of Compliance

Certificate of conformity Power generation unit PIKO 1.5 MP, 2.0 MP, 2.5 MP, 3.0 MP, 3.6 MP, 4.2 MP

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Flexible hoses - Non-metallic materials

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

SILENT CLASS NOTATION

Type MMV Medium Power Cable

CRICKET AUSTRALIA. Schedule for the Junior Formats Survey and Feedback Incentivisation Promotion

Pressure Measurement Single-range transmitters for general applications

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Certificate of Conformity

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Compact pressure switches for gas and air

Monitoring device NTS 30

9700 Transmitter Submersible hydrostatic level transmitter

Y-Pattern Strainer Valves Range

Prewired position switches FA series

CAST IRON SAFETY VALVE TYPE 6301

REFERENCE SPECIFICATION FOR END

DK46 - DK800 Supplementary instructions

Pressure switch and Thermostat CAS

IECEx Certificate of Conformity Annexe

Pressure switch and Thermostat KPS

UL TEST REPORT AND PROCEDURE

Relative pressure switch type 521

ibridge and ibridge Ultra

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Technical information

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005

X2 Metallized Polypropylene Film Capacitor JFV

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Operating Instructions

Dynamic Positioning Systems

Transcription:

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-13345 This is to certify that the Terminal Block with type designation(s) ST-COMBI, ST, STS Issued to Phoenix Contact GmbH & Co. KG Blomberg, Germany is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application Pluggable spring cage terminal blocks for use in Marine and Offshore Applications This Certificate is valid until 2016-12-31. Issued at Høvik on 2014-05-07 DNV local station: Essen CMC Western Germany for Det Norske Veritas AS Approval Engineer: Nicolay Horn Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. Form No.: TA 1411a Issue: 2013-10 Page 1 of 6

Name & Place of Manufacturer Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany Phoenix Feinbau GmbH & Co. KG Gustavstr. 3 58511 Lüdenscheid Germany Phoenix Contact India Pvt. Ltd Dhatir Road, Village-Dhudhola Prithla, Palwal, Faridabad 121102 Haryana India Phoenix Contact Wielkopolska Spolka z.o.o. Ul. Celna 5 64-300 Nowy Tomysl Poland Eviop Tempo S.A. Leoforos Kymis 212 340 02 Vasilikon Greece Phoenix Contact Asia-Pacific (Nanjing) Co. Ltd. 36 Phoenix Road Jiangning Nanjing 211100 Nanjing Peoples Republic of China Product description Type ST-COMBI: Pluggable spring cage terminal blocks Type designation Rated Cross-section Rated Current Rated Voltage Part No. [mm 2 ] [A] [V] ST 2,5/ 1P 2,5 24 500 3040012 ST 2,5/ 2P 2,5 24 500 3042133 ST 2,5-TWIN/ 1P 2,5 24 500 3042117 ST 2,5-TWIN-MT/ 1P 2,5 16 500 3040766 ST 2,5-QUATTRO/ 2P 2,5 24 500 3040038 ST 2,5-QUATTRO/ 4P 2,5 24 500 3042159 STTB 2,5/ 2P 2,5 22 500 3040054 STTB 2,5/ 2P-PV 2,5 22 500 3040070 ST 2,5/ 1P-PE 2,5 - - 3040025 ST 2,5/ 2P-PE 2,5 - - 3042146 ST 2,5-TWIN/ 1P-PE 2,5 - - 3042120 ST 2,5-QUATTRO/ 2P-PE 2,5 - - 3040041 ST 2,5-QUATTRO/ 4P-PE 2,5 - - 3042162 STTB 2,5/ 2P-PE 2,5 - - 3040067 SC 2,5/ xx 2,5 24 500 - SC 2,5-RZ/ xx 2,5 24 500 - SC 2,5/1-L 2,5 24 500 3042188 SC 2,5-RZ/1-L 2,5 24 500 3042214 SP 2,5/ xx 2,5 24 500 - SPB 2,5/ xx 2,5 24 500 - SPDB 2,5/ xx 2,5 24 500 - SP 2,5/1-L 2,5 24 500 3043019 SP 2,5/1-M 2,5 24 500 3043043 SP 2,5/1-R 2,5 24 500 3043077 SPB 2,5/1-L 2,5 24 500 3043103 SPB 2,5/1-M 2,5 24 500 3043132 SPB 2,5/1-R 2,5 24 500 3043161 SPDB 2,5/1-L 2,5 24 500 3043190 SPDB 2,5/1-M 2,5 24 500 3043226 SPDB 2,5/1-R 2,5 24 500 3043255 Form No.: TA 1411a Issue: 2013-10 Page 2 of 6

Type designation Rated Cross- Section Rated Current Rated Voltage Part No. (mm 2) (A) (V) ST 1,5 1,5 17,5 500 3031076 ST 1,5-PE 1,5 - - 3031513 ST 1,5-TWIN 1,5 17,5 500 3031128 ST 1,5-TWIN-PE 1,5 - - 3031144 ST 1,5-QUATTRO 1,5 17,5 500 3031186 ST 1,5-QUATTRO-PE 1,5 - - 3031209 STTB 1,5 1,5 17,5 500 3031157 STTB 1,5-PV 1,5 17,5 500 3031526 ST 2,5 2,5 24 800 3031212 ST 2,5-PE 2,5 - - 3031238 ST 2,5-TWIN 2,5 24 800 3031241 ST 2,5-TWIN-PE 2,5 - - 3031267 ST 2,5-QUATTRO 2,5 24 800 3031306 ST 2,5-QUATTRO-PE 2,5 - - 3031322 STTB 2,5 2,5 22 500 3031270 STTB 2,5-PV 2,5 22 500 3031539 ST 4 4 32 800 3031364 ST 4-PE 4 - - 3031380 ST 4-TWIN 4 32 800 3031393 ST 4-TWIN-PE 4 - - 3031416 ST 4-QUATTRO 4 32 800 3031445 ST 4-QUATTRO-PE 4 - - 3031461 STTB 4 4 30 500 3031429 STTB 4-PV 4 30 500 3031542 ST 6 6 41 800 3031487 ST 6-PE 6 - - 3031500 ST 10 10 57 800 3036110 ST 10-PE 10 - - 3036165 ST 16 16 76 800 3036136 ST 16-PE 16 - - 3036178 ST 35 35 125 800 3036149 ST 35-PE 35 - - 3036194 TYPE STS: Spring cage feed-through terminal block Type designation Rated Cross Section Rated Current Rated Voltage (mm 2) (A) (V) Part No. STS 2,5 2,5 24 800 3036398 STS 2,5-MT 2,5 16 400 3036990 STS 2,5-PE 2,5 - - 3036411 STS 2,5-QUATTRO 2,5 24 800 3031746 STS 2,5-QUATTRO-PE 2,5 - - 3031759 STS 2,5-TG 2,5 16* 400* 3037009 STS 2,5-TWIN 2,5 24 800 3031720 STS 2,5-TWIN-PE 2,5 - - 3031733 STS 4 4 32 800 3036424 STS 4-PE 4 3036440 STS 4-QUATTRO 4 32 800 3031681 STS 4-QUATTRO-PE 4 3031694 STS 4-TWIN 4 32 800 3031665 STS 4-TWIN/L 4 32 800 3036592 STS 4-TWIN-PE 4 - - 3031678 Form No.: TA 1411a Issue: 2013-10 Page 3 of 6

Type designation Rated Cross Section Rated Current Rated Voltage (mm 2) (A) (V) Part No. STS 6 6 41 800 3038121 STS 6-PE 6 3038147 STS 6-TWIN 6 41 800 3038150 STS 6-TWIN-PE 6 - - 3038176 STTBS 2,5 2,5 22 500 3038464 STTBS 2,5-LA 24 RD 2,5 22 32 3039939 STTBS 2,5-PE 2,5 3038480 STTBS 2,5-PV 2,5 22 500 3038477 STTBS 4 4 28 500 3035056 STTBS 4-PE 4 3035072 STTBS 4-PV 4 28 500 3035085 * Current and voltage are determined by the plug used Material: Insulation housing: Polyamide 6,6 Contact bridge: HC copper, contact face tinned Clamping spring: Stainless Steel Application/Limitation Installation in according to Phoenix catalogue and DNV Rules. Type Approval documentation ST 2,5/ 1P VT-EL/Sb/Schu 2002-02-22 0501 Rev. 00 ST 2,5/ 2P Lab/-ICT/Gro/Lin/Schu 2003-07-12 0338 Rev. 00 ST 2,5-TWIN/ 1P Lab/-ICT/Gro/Lin/Schu 2004-03-29 0122 Rev. 01 ST 2,5-TWIN-MT/ 1P Lab/-ICT/Gro/Lin/Schu 2004-08-11 1920 Rev. 00 ST 2,5-QUATTRO/ 2P VT-EL/Sb/Schu 2002-03-15 0814 Rev. 00 ST 2,5-QUATTRO/ 4P Lab/-ICT/Gro/Schu 2004-08-24 0146 Rev. 01 STTB 2,5/ 2P Lab/-ICT/Gro/Lin/Schu 2004-08-18 1637 Rev. 01 STTB 2,5/ 2P-PV Lab/-ICT/Gro/Lin 2004-08-19 1925 Rev. 00 ST 2,5/ 1P-PE Lab/-ICT/Gro/Lin 2004-08-13 1922 Rev. 00 ST 2,5/ 2P-PE Lab/-ICT/Gro/Lin/Schu 2004-03-31 1846 Rev. 02 ST 2,5-TWIN/ 1P-PE Lab/-ICT/Gro/Lin/Schu 2004-03-15 0698 Rev. 00 ST 2,5-QUATTRO/ 2P-PE Lab/-ICT/Gro/Lin 2004-08-16 1923 Rev. 00 ST 2,5-QUATTRO/ 4P-PE Lab/-ICT/Gro/Lin 2004-04-07 1024 Rev. 00 STTB 2,5/ 2P-PE Lab/-ICT/Gro/Lin 2004-09-20 1966 Rev. 00 SC 2,5/ xx VT-EL/ Gro/Lin/Schu 2003-07-14 1771 Rev. 01 SC 2,5-RZ/ xx Lab/-ICT/Gro/Lin 2004-12-03 2006 Rev. 00 SC 2,5/1-L VT-EL/ Gro/Lin/Schu 2003-07-14 1771 Rev. 01 SC 2,5-RZ/1-L Lab/-ICT/Gro/Lin 2004-12-03 2006 Rev. 00 SP 2,5/ xx Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPB 2,5/ xx Lab/-ICT/Gro/Lin 2004-03-29 1920 Rev. 00 SPDB 2,5/ xx Lab/-ICT/Gro/Lin 2004-03-29 1920 Rev. 00 SP 2,5/1-L Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SP 2,5/1-M Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SP 2,5/1-R Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPB 2,5/1-L Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPB 2,5/1-M Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPB 2,5/1-R Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 Form No.: TA 1411a Issue: 2013-10 Page 4 of 6

SPDB 2,5/1-L Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPDB 2,5/1-M Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 SPDB 2,5/1-R Lab/-ICT/Gro/Lin 2004-08-11 1920 Rev. 00 ST 1,5 VT-EL/Gro/Schu 2000-11-02 1421 Rev. 00 ST 1,5-PE VT-EL/Gro/Schu 2000-11-08 1426 Rev. 00 ST 1,5-TWIN VT-EL/Gro/Lin/Schu 2002-10-10 1422 Rev. 01 ST 1,5-TWIN-PE VT-EL/Gro/Lin/Schu 2002-10-10 1427 Rev. 01 ST 1,5-QUATTRO VT-EL/Gro/Lin/Schu 2002-10-10 1423 Rev. 01 ST 1,5-QUATTRO-PE VT-EL/Gro/Lin/Schu 2002-10-10 1428 Rev. 01 STTB 1,5 VT-EL/Gro/Schu 2000-11-07 1424 Rev. 00 STTB 1,5-PV VT-EL/Gro/Schu 2003-02-18 1425 Rev. 01 ST 2,5 Lab-ICT/Gro/Schu 2003-04-28 1893 Rev. 01 ST 2,5-PE VT-EL/Gro/Schu 2000-05-25 0084 Rev. 00 ST 2,5-TWIN VT-EL/Gro/Schu 2000-05-30 1895 Rev. 00 ST 2,5-TWIN-PE VT-EL/Gro/Schu 2000-05-25 0112 Rev. 00 ST 2,5-QUATTRO VT-EL/Gro/Schu 2000-05-30 0177 Rev. 00 ST 2,5-QUATTRO-PE VT-EL/Gro/Schu 2000-05-30 0266 Rev. 00 STTB 2,5 VT-EL/Gro/Lin/Schu 2003-02-12 1894 Rev. 01 STTB 2,5-PV VT-EL/Gro/Schu 2003-03-17 0265 Rev. 02 ST 4 VT-EL/Gro/Schu 2002-04-03 1398 Rev. 02 ST 4-PE VT-EL/Gro/Schu 2002-05-14 1404 Rev. 02 ST 4-TWIN VT-EL/Gro/Schu 2002-04-04 1399 Rev. 02 ST 4-TWIN-PE VT-EL/Gro/Schu 2002-06-20 1409 Rev. 02 ST 4-QUATTRO VT-EL/Gro/Schu 2002-04-03 1400 Tev. 02 ST 4-QUATTRO-PE VT-EL/Gro/Schu 2002-05-27 1408 Rev. 02 STTB 4 VT-EL/Gro/Schu 2002-04-05 1401 Rev. 03 STTB 4-PV VT-EL/Gro/Schu 2003-03-17 1410 Rev. 04 ST 6 VT-EL/Gro/Lin/Schu 2003-03-06 1396 Rev. 01 ST 6-PE VT-EL/Gro/Schu 2000-10-12 1406 Rev. 00 ST 10 VT-EL/Gro/Lin/Schu 2003-02-25 1505 Rev. 01 ST 10-PE VT-EL/Gro/Schu 2003-03-10 0232 Rev. 01 ST 16 VT-EL/Gro/Lin/Schu 2003-02-25 1506 Rev. 01 ST 16-PE VT-EL/Gro/Schu 2003-03-06 0687 Rev. 01 ST 35 VT-EL/Gro/Schu 2003-02-17 1565 Rev. 01 ST 35-PE VT-EL/Gro/Schu 2001-12-05 1588 Rev. 00 STS 2,5 LAB-ICT/Gro/Lin 2005-03-07 1585 Rev. 03 STS 2,5-MT LAB-ICT/Gro/Lin 2005-07-19 1648 Rev. 01 STS 2,5-PE LAB-ICT/Gro/Lin 2004-12-16 1587 Rev. 01 STS 2,5-QUATTRO LAB-ICT/Gro/Lin 2005-02-21 1443 Rev. 03 STS 2,5-QUATTRO-PE LAB-ICT/Gro/Lin/Schu 2003-05-27 1441 Rev. 01 STS 2,5-TG LAB-ICT/Gro/Lin 2005-06-23 1725 Rev. 01 STS 2,5-TWIN LAB-ICT/Gro/Lin 2005-02-21 1440 Rev. 03 STS 2,5-TWIN-PE LAB-ICT/Gro/Lin 2004-12-20 1442 Rev. 01 STS 4 LAB-ICT/Gro/Lin 2005-03-03 1589 Rev. 03 STS 4-PE LAB-ICT/Gro/Lin 2004-10-04 1594 Rev. 01 STS 4-QUATTRO LAB-ICT/Gro/Lin 2005-02-21 1221 Rev. 02 STS 4-QUATTRO-PE LAB-ICT/Gro/Lin 2004-10-04 1219 Rev. 01 STS 4-TWIN LAB-ICT/Gro/Lin 2005-02-21 1058 Rev. 02 STS 4-TWIN/L LAB-ICT/Gro/Lin 2005-03-03 1586 Rev. 01 STS 4-TWIN-PE LAB-ICT/Gro/Lin 2004-10-05 1075 Rev. 01 STS 6 LAB-ICT/Gro/Schu 2003-06-18 0296 Rev. 00 Form No.: TA 1411a Issue: 2013-10 Page 5 of 6

STS 6-PE LAB-ICT/Gro/Schu 2003-06-24 0116 Rev. 00 STS 6-TWIN LAB-ICT/Gro/Schu 2003-04-09 0059 Rev. 00 STS 6-TWIN-PE LAB-ICT/Gro/Schu 2003-04-23 0092 Rev. 00 STTBS 2,5 LAB-ICT/Gro/Schu 2005-02-09 1675 Rev. 02 STTBS 2,5-LA 24 RD LAB-ICT/Gro/Schu 2005-02-16 2065 Rev. 00 STTBS 2,5-PE LAB-ICT/Gro/Lin 2005-03-09 1682 Rev. 01 STTBS 2,5-PV LAB-ICT/Gro/Lin 2005-03-07 1677 Rev. 02 STTBS 4 LAB-ICT/Gro/Lin 2005-06-23 2027 Rev. 01 STTBS 4-PE LAB-ICT/Gro/Lin 2004-12-13 2028 Rev. 00 STTBS 4-PV LAB-ICT/Gro/Lin 2004-12-14 2029 Rev. 00 Tests carried out Type tests in accordance with IEC 61984, IEC 60947-7-1, IEC 60947-7-2, and vibration test in accordance with IEC 60068-2-6 and/or DIN EN 50155 and climatic test in accordance with IEC 60068-2-30. Marking of product Phoenix Contact - Type designation - Main data. (All type designation may be followed by suffix such as color or packaging options) Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Survey to be performed at least every second year. END OF CERTIFICATE Form No.: TA 1411a Issue: 2013-10 Page 6 of 6