Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) SEAMLESS JUNCTIONAL CONNECTIONS

Similar documents
CONTROL WITHOUT COMPROMISE

FRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach.

HeadActive TECHNICAL DATA AND INSTRUCTIONS OF USE. Manufactured by: Onlywise Unipessoal Lda. Calle Santa Caterina nº 124 Porto (Portugal) PT

User Manual. Ambulatory Spinal-Air Decompression Collar

DDS CERVICAL TRACTION COLLAR

BIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair. Shoulder Series Technique Guide by: Thomas Youm, MD

i2i Head & Neck Positioning System

REVEAL IN DIE-CUT REMOVE FOR PRINTING

Medical Education Calendar of Events ONE-TO-ONE CADAVERIC ONE-TO-ONE CADAVERIC CADAVERIC ONE-TO-ONE GROUP LEARNING GROUP LEARNING/

Aesculap ProSpace Titanium / PEEK

Pneumatic Kerrison. Technology that makes life easier. Aesculap Neurosurgery

Modular OMF-System Cluster

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

IMPLANTS & INSTRUMENTS FOR TISSUE REPAIR

Patient Positioning Made Easier

The Arizona Quarterly

LITe Decompression System Surgical Technique. Non-reflective PVD coating Full microdiscectomy set Simple, low-profile light source

Rotator Cuff Solution. Combined Strengths. Precise Control. TWINFIX Ultra FOOTPRINT Ultra Suture Anchors

1. Connect the attached anesthesia mask to your anesthesia system using the included tubing and connectors.

Ultra Lightweight Family

GRYPHON BR Suture Anchor

Injector system for implantation of 1stQ foldable intraocular lenses

Operation Manual. Woodpecker

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

The Peritrochanteric Space The Next Frontier in Hip Repair

See JAY Product Comparison Guide notes to the right. Cushions HCPCS Code Page # Lateral Stability Forward Stability. Backs HCPCS Code Page #

Standard Collection Setup Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Adapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR

Ultra Lightweight Family

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

TECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

DeskCycle USER S MANUAL. Ellipse QUESTIONS / PROBLEMS. Order# Support and Contact: See the support link at DeskCycle.com

tad PRODUCTCATALOG DUAL-TOP TEMPORARY ANCHORAGE DEVICES (TADS) Dual-Top TAD System Kit Dual-Top Temporary Anchor Devices (TADs) Button Top TAD

Assessments SIMPLY GAIT. Posture and Gait. Observing Posture and Gait. Postural Assessment. Postural Assessment 6/28/2016

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

Device-Related Pressure Ulcer/Injury Prevention Cervical Collar Recommendations and Guidance

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to:

See JAY Product Comparison Guide notes to the right. Cushions HCPCS Code Page # Lateral Stability Forward Stability. Backs HCPCS Code Page #

Study & Manipulative Training Guide

X-FACTOR THINKING CHANGING THE WAY YOU THINK ABOUT DR A SINGLE DETECTOR. A FAMILY OF SOLUTIONS. DRX Family of Products

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

INSTRUCTIONS 360 Y-DROP HAGIE STS 2015

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

HI-PRESS HYDRAULICS Ltd

Satisfaction. For you and your patients.

3 Post Pressure Fit System Owner s Manual

MyoSure Tissue Removal System. For you and your patients.

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

Hemorrhoid Multiple Band Ligator Set Instructions for Use

Model 6202 Reduced Oxygen Breathing Device 2

Better Body, Better Golf

Rescue Ladder Model: KT ft (5.48m)

INSTRUCTION MANUAL. January 23, 2003, Revision 0

No guesswork. Controllable tension for labral repairs of the shoulder and hip. BIORAPTOR Knotless Suture Anchor

Installation Manual. Version 12-10

RADON 237A: ASSEMBLY GUIDE. Revision Valid for MY2017 Radon

Henry Pratt Diviner Position Indicator. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #:DIVPOSNOM Revision Date: 2/9/11

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

INFUSION SYSTEM (110V) (220V) USER S MANUAL

HEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock

MSA Latchways Solutions for Industry

Omega 3 Fatty Acid (O3FA) Bioabsorbable Coated Mesh

889P & 889P/B Backboard

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

AllPro Foot. Posterior Mount Product Manual

The TURTLE Concept Contents:

ADVANCED CORE DECOMPRESSION SYSTEM X-REAM

TABLE OF CONTENTS/LIST OF EXHIBITS

Lightweight II S.E. Improved Design & Acoustics. Stethoscope

August 28-29, 2009 The Pinehurst Resort and Spa Village of Pinehurst, NC

AndrewsREF.org 1020 Gulf Breeze Parkway, Gulf Breeze, FL (850)

LarySeal - Laryngeal Mask Airways

Packaging Information Bulk Packs Non-Gas

The advantages of the Impact NecksGen unit

The A-dec Difference Legendary Reliability

USER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder

CinchLock SS (Sports Sheath) Knotless Labrum Restoration SURGICAL TECHNIQUE

Santi Ribot in TITAN DESERT 2012 REX 3.0

Stability Trainer. New! Balance Products. Rocker and Wobble Boards. New!

CT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C

Proper Operation of Heath Consultants Incorporated Plunger Bar

Universal Anchoring Adapter For Mercedes

GALISO SOAP OPTION FOR PCT-ADW-D

New. View our Evolution Product Video at

Triple Tine Mechanical Grapple

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Tube Clamps Advanced Tube Clamps for the Most Demanding Applications

QUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER

Bruker Sample Transport

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

Challenge Friends, Get Ranked and Earn Points with the FUTCHI_App Players

The Criticality of Cooling

Transcription:

11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. 2001 SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points. 2003 SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets. 2008 DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector. 2008 2009 and beyond To order, call DePuy Spine Customer Service (1-800-227-6633). www.depuyspine.com MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA 02767 USA Tel: +1 (800) 227-6633 CR17-00-001 XX00-00-000 10/08 09/08

8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator

8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator

8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator

11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. 2001 SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points. 2003 SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets. 2008 DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector. 2008 2009 and beyond To order, call DePuy Spine Customer Service (1-800-227-6633). www.depuyspine.com MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA 02767 USA Tel: +1 (800) 227-6633 CR17-00-001 XX00-00-000 10/08 09/08

11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. 2001 SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points. 2003 SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets. 2008 DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector. 2008 2009 and beyond To order, call DePuy Spine Customer Service (1-800-227-6633). www.depuyspine.com MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA 02767 USA Tel: +1 (800) 227-6633 CR17-00-001 XX00-00-000 10/08 09/08