High Integrity Pressure Protection Systems HIPPS

Similar documents
Every things under control High-Integrity Pressure Protection System (HIPPS)

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Valve Communication Solutions. Safety instrumented systems

Solenoid Valves used in Safety Instrumented Systems

Partial Stroke Testing. A.F.M. Prins

Hydraulic (Subsea) Shuttle Valves

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

DeZURIK. KSV Knife Gate Valve. Safety Manual

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Implementing IEC Standards for Safety Instrumented Systems

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Deltaflux Control Valve

YT-300 / 305 / 310 / 315 / 320 / 325 Series

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Bespoke Hydraulic Manifold Assembly

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

Instrumented Safety Systems

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Jamesbury Pneumatic Rack and Pinion Actuator

SPR - Pneumatic Spool Valve

Safety manual for Fisher GX Control Valve and Actuator

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

Safety Manual VEGAVIB series 60

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

Solenoid Valves For Gas Service FP02G & FP05G

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual OPTISWITCH series relay (DPDT)

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

innova-ve entrepreneurial global 1

Knowledge, Certification, Networking

Safety Manual VEGAVIB series 60

Flowatch Multiphase Flow Meter

Ultima. X Series Gas Monitor

Section 1: Multiple Choice

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

Continuous Gas Analysis. ULTRAMAT 6, OXYMAT 6 Safety Manual. Introduction 1. General description of functional safety 2

Rosemount 2130 Level Switch

Slam Shut Valves SBC 782

PROCESS AUTOMATION SIL. Manual Safety Integrity Level. Edition 2005 IEC 61508/61511

Accelerometer mod. TA18-S. SIL Safety Report

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Understanding safety life cycles

Section 1: Multiple Choice Explained EXAMPLE

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System (HIPPS) to IEC 61511

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance

Rosemount 2120 Level Switch

HIPPS Development Project

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis

Achieving Compliance in Hardware Fault Tolerance

A Complete Solution For HIPPS

The Key Variables Needed for PFDavg Calculation

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Partial Stroke Testing for SRD991 and SRD960

Special Documentation Proline Promass 80, 83

Safety Manual VEGASWING 61, 63. NAMUR With SIL qualification. Document ID: 52084

Failure Modes, Effects and Diagnostic Analysis

UNDERSTANDING SAFETY INTEGRITY LEVEL

SPECIAL PRINT. Innovative Control Technology. Safety in the Process Industry. SAMSON AG Manuel Hinkelmann Marcel Richter Monika Schneider

SAFETY SEMINAR Rio de Janeiro, Brazil - August 3-7, Authors: Francisco Carlos da Costa Barros Edson Romano Marins

Transmitter mod. TR-A/V. SIL Safety Report

THE IMPROVEMENT OF SIL CALCULATION METHODOLOGY. Jinhyung Park 1 II. THE SIL CALCULATION METHODOLOGY ON IEC61508 AND SOME ARGUMENT

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

CHANGE HISTORY DISTRIBUTION LIST

Failure Modes, Effects and Diagnostic Analysis

Commissioning and safety manual

Vibrating Switches SITRANS LVL 200S, LVL 200E. Safety Manual. NAMUR With SIL qualification

IGEM/SR/15 Edition 5 Communication 1746 Integrity of safety-related systems in the gas industry

Failure Modes, Effects and Diagnostic Analysis

Competence in Functional Safety

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

PL estimation acc. to EN ISO

Failure Modes, Effects and Diagnostic Analysis

Interactive Solutions Tool High-Integrity Pressure Protection Systems (HIPPS)

Safety Instrumented Systems in Regulator Station Design. SIL Verification of Standard Design Alan Burt

New Thinking in Control Reliability

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

Failure Modes, Effects and Diagnostic Analysis

Session: 14 SIL or PL? What is the difference?

Design of Relief Valves/Devices/Systems for Cryogenic Apparatuses and Installations

A large Layer of Protection Analysis for a Gas terminal scenarios/ cause consequence pairs

PREDICTING HEALTH OF FINAL CONTROL ELEMENT OF SAFETY INSTRUMENTED SYSTEM BY DIGITAL VALVE CONTROLLER

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Safety-critical systems: Basic definitions

Proposed Abstract for the 2011 Texas A&M Instrumentation Symposium for the Process Industries

Transcription:

High Integrity Pressure Protection Systems HIPPS

HIPPS > High Integrity Pressure Protection Systems WHAT IS A HIPPS The High Integrity Pressure Protection Systems (HIPPS) is a mechanical and electrical system designed in order to reduce the chance that the system pressure will exceed the tolerable allowable pressure. The protection against over-pressure is obtained by quickly isolating the source causing the overpressure. The entire HIPPS package consists of: > Initiators > Logic solver > Final Element The initiators are field sensors and they are the inputs required to detect the hazardous condition. The logic solver accepts these inputs and generates correct outputs that change the state of the final elements in order to mitigate the hazardous condition. WHY AND WHEN USE A HIPPS The HIPPS are used in the oil & gas industries in order to provide pressure protection of pipelines, piping, vessels and process packages against over pressure, allowing the use of lower design pressure downstream the HIPPS. Conventional design standards against overpressure are based on the use and the proper sizing of relief devices, such as relief valves.

With HIPPS the overpressure protection is achieved by reducing to a tolerable degree the risk that the pressure can exceed certain maximum levels. HIPPS design is governed by: > IEC 61508: Functional Safety of Electrical / Electronic / Programmable Electronic Safety Related Systems > IEC 61511: Functional Safety: Safety Instrumented Systems for the Process Sector, > ANSI/ISA S84.01-1996, Application of Safety Instrumented Systems (SIS) for the Process Industry, The use of the HIPPS becomes the only feasible and practicable approach from a technical and commercial point of view, especially when: > environmental restrictions and safety constraints limit the venting > overpressure risk shall be reduced > extremely high pressure and/or flow rate are involved > sizing of relief device is difficult to define or inadequate due to chemical reactions, multiphase fluids or plugging > on existing systems in order to avoid replacement of flare system when adding new units

HIPPS > High Integrity Pressure Protection Systems TECHNICAL DESCRIPTION THE HIPPS System is based on a logic solver with two shutdown valves and three pressure transmitters. INITIATORS The pressure sensing initiators are electronic pressure transmitters, two wire 4-20 ma smart devices, mounted on a High Integrity Manifold Block (HIMB) and wired to separate card in the logic solver. The 2oo3 voting logic is implemented in the logic solver. The pressure transmitter contains self diagnostic and is programmed to send its output to a specified failure state. LOGIC SOLVER The logic solver is responsible for activation of the relevant signal outputs on the basis of the preconfigured applications and inputs from the initiators. PLC available on the market, SIL 3 certified, are used as logic solver. The system consist of a Central Processing Unit (CPU) and fail-safe redundant I/O suitable for safety-related applications. All safety communication between the control unit and the associated I/O cards are redundant. The logic solver can also be designed based on Solid State Logic (SSL), as alternative. Control Cabinet can be supplied suitable for hazardous area installation in EEx-d enclosure IP-66 or for safe area installation in standard 19 rack cabinet IP-54. FINAL ELEMENTS The final control element contributes approximately 50% to the PFD (Probability of Failure on Demand). Pietro Fiorentini, since 1940, has a long well proven experience in design and manufacture different type of valves, including DELTAFLUX, the quarter turn control valve used in HIPPS package. DELTAFLUX is designed to be opened against full differential pressure, so that there is no need for a by-pass arrangement for pressurization and start-up as typically the case with ball valves. One of the most difficult parts of complying with SIS standards is the testing interval often required for final elements, such as block valves. Most SIS block valves are function tested only at unit turnaround. Consequently, many users are looking for ways to supplement the off-line full stroke test, such as on-line full stroke testing or partial stroke testing.

With DELTAFLUX, it is possible to perform Partial Stroke Testing (PST), a cost effective alternative to on-line Full Stroke Testing (FST). The use of PST often eliminates the need for full flow bypasses, reducing engineering, capital, and installation costs, as well as potentially hazardous operation such as the case of having the by-pass inadvertently left open. SIS standards do not recommend the use of the by-pass on the final element. The valve is designed to maintain tight shut-off capabilities under all possible operating conditions, and even long periods of inactivity of the valve do not influence the response time of the valve. The installed actuator is a spring return hydraulic or pneumatic high pressure actuators. The overall response time of the system can be in the range of 2 or 3 seconds depending on the valve/actuator combination. Valve can be supplied with different material of construction for all valve components (body, bonnet, seat, ball, steam). Valve size ranges from 2 to 40 rating up to Rating ANSI1500.THE HIPPS System is based on a logic

STANDARDS IEC 61508 is a performance based standard which provides a detailed framework and life-cycle approach for the design and implementation of safety systems with different level of risk definition. This standard is mainly focused on Electrical/Electronic/Programmable Electronic Safety related equipment, but it also provides a framework for safety related equipments, including mechanical components. The performance of the safety instrumented system (SIS) is based on a target safety integrity level (SIL) that is defined during the safety requirements specification development. According to the standards the ability of the SIS to achieve a specific SIL must be validated at each stage of design and prior to any change made to the design after commissioning. The entire operation, testing, and maintenance procedures and practices are also judged for agreement with the target SIL. Four different SIL are defined, depending on the consequence severity, the possibility of avoiding the hazardous event and the likelihood frequencies of the event. The SIL must be assigned by the user based on the risk reduction necessary to achieve the user's risk tolerance.it is the user's responsibility to ensure consistent and appropriate SIL assignments by establishing a risk management philosophy and risk tolerance. The risk reduction provided by the HIPPS is equivalent to the probability of failure on demand attributable (PFD) to all of the HIPPS devices from the sensor through the logic solver and final elements. The relationship between the SIL and PFD for low Demand Mode of Operation is shown in following Table. Safety Integrity Level (SIL) 4 3 2 1 Low Demand Mode of Operation Average Probability of Failure on Demand (PFD) 10-5 to < 10-4 10-4 to < 10-3 10-3 to < 10-2 10-2 to < 10-1 Risk Reduction Factor (RRF) 10,000 to 100,000 1,000 to 10,000 100 to 1,000 10 to 100 According to IEC 61508 in order to meet the SIL 3 requirements, the system must comply with both probabilistic requirements and with architectural constraints.

HIPPS ABBREVIATIONS, SYMBOLS & DEFINITIONS The most commonly used abbreviation and concept for the HIPPS are the following: > CCF > Fph > FPPD > FST > HFT > HIMB > HIPPS > IEC > MTBF > MTTR > PFD > PLC > PST > RRF > SFF > SIL > SIS > SSL Common Cause Failure Failure per hour Failure Probability per Demand Full Stroke Testing Hardware Fault High Integrity Manifold Block High Integrity Pressure Protection Systems International Electromechanical Commission Mean Time Between Failure Mean Time to Repair Probability of Failure on Demand Programmable Logic Controller Partial Stroke Testing Risk Reduction Factor Safe Failure Fraction Safety Integrity Level Safety Instrumented System Solid State Logic Pietro Fiorentini HIPPS package is SIL 3 certified by TUV

Pietro Fiorentini S.p.A. via E.Fermi 8/10 I-36057 Arcugnano (VI) Italy Tel. +39 0444 968.511 Fax. +39 0444 960.468 via Rosellini 1 I-20124 Milano Italy Tel. +39 02 696.14.21 Fax. +39 02 688.04.57 www.fiorentini.com The data are not binding. We reserve the right to make eventual cheanges without prior notice. CT-s524-E April 2007