VIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page

Similar documents
VIESMANN. Service instructions VITOSOL-F. for contractors. Vitosol-F. For applicability, see the last page GB 3/2009 Please keep safe.

VIESMANN. Installation instructions. Gas type conversion to G 31. Safety instructions. Opening the Vitodens. for contractors

Installation and commissioning instructions 255 series and 256 series

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Flamco Flamco-Fill STA Flamco-Fill STM

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Instruction Manual Contact Pressure Vacuum Gauge

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Operating and maintenance manual Filter and reducing station Series / 1.0

Budget Range Operators Handbook

Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

DK46 - DK800 Supplementary instructions

Declaration of Conformity as per Directive 97/23/EC

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, operating and maintenance Instructions for Seemag bypass level indicator

ITT RICHTER CHEMIE-TECHNIK

11. Spare Parts. applications since applications since

Operating Instructions

Installation and Operating Instructions Bypass Flow Meter DST

System Pressure Manager Standard & System Pressure Manager Plus

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Flowmeter. Original operating manual DFM

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Siphon vessel / Priming aid

MANUAL GAS MANIFOLDS

FlowSol B / B HE * * Manual for the specialised craftsman. Installation Operation Commissioning

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AUTOMATIC GAS MANIFOLDS

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

PRAHER PLC-MP AQUASTAR MANAUL 2009

CALEFFI. Ball zone valves. series /03 GB

Instruction Manual Differential Pressure Transmitter

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

80 Litre Suction Oil Drainer

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

OPERATING INSTRUCTIONS

Installation and Maintenance Instruction Manual

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

Installation and Maintenance Instruction Manual

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Operating Instructions

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

AIR STAPLER MODEL: CSG1C Part No

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pressure maintenance systems with compressors

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

FV Flash Vessel Installation and Maintenance Instructions

Installation and Commissioning Manual Solar Stations FlowCon FA Evolution II

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

HERZ-Motorised flow controler

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Type overview. R B2 en-gb subject to changes 1

GENO -Flushing Compressor Product Data Sheet F 02

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

A17W49_MASEM_F_EN MANUAL

14. Exploded View. Page 68

Safety Valves. Product Information. It s all at Albion

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Declaration of Conformity as per Directive 97/23/EC

Installation Operation Maintenance

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Overview of types. Technical data. Safety notes

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

Airfix D-E-B Installation and operating instructions

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

MODEL NUMBER: AS18-2 USER GUIDE

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

OWNER S TECHNICAL MANUAL

Operating instructions for KLINGER SCHÖNEBERG ball valves type RK-Chemoball, type RK-Proball and type RK-Ecoball

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Manual Actuated Boiler Blowdown Valves

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Transcription:

Service instructions for contractors VIESMANN Vitosol 200-T, 300-T For applicability, see the last page VITOSOL 200-T, 300-T 12/2008 Please keep safe.

Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Please note! This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These instructions are exclusively designed for qualified personnel. Work on electrical equipment must only be carried out by a qualified electrician. The system must be commissioned by the system installer or a qualified person authorised by the installer. Regulations Observe the following when working on this system all legal instructions regarding the prevention of accidents, all legal instructions regarding environmental protection, the Code of Practice of relevant trade associations. all current safety regulations as defined by DIN, EN, DVGW, VDE and all locally applicable standards Working on the system Isolate the system from the power supply and check that it is no longer 'live', e.g. by removing a separate fuse or by means of a main isolator. Safeguard the system against unauthorised reconnection. Please note! Electronic modules can be damaged by electrostatic discharges. Touch earthed objects, such as heating or water pipes, to discharge static loads. Repair work! Please note Repairing components that fulfil a safety function can compromise the safe operation of your heating system. Replace faulty components only with original Viessmann spare parts. 2

Safety instructions Safety instructions (cont.) Ancillary components, spare and wearing parts Please note! Spare and wearing parts that have not been tested together with the heating system can compromise its function. Installing non-authorised components and non-approved modifications or conversions can compromise safety and may invalidate our warranty. For replacements, use only original spare parts supplied or approved by Viessmann. 3

Index Index Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance... 5 Further details regarding the individual steps... 6 Parts lists Parts list Vitosol 200-T, type SD2A... 11 Parts list Vitosol 300-T, type SP3A... 13 Specification Vitosol 200-T, type SD2A... 15 Vitosol 300-T, type SP3A... 15 Solar-Divicon (accessory)... 15 Heat transfer medium (accessory)... 16 Certificates Declaration of conformity... 17 4

Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance For further information regarding the individual steps, see the page indicated Commissioning steps Inspection steps Maintenance steps Page 1. Cleaning, testing for leaks and filling the solar thermal system... 6 2. Checking the function of the safety equipment 3. Checking the expansion vessel and the system pressure... 7 4. Checking the electrical connections... 7 5. Starting the heating system... 7 6. Ventilating the solar thermal system... 8 7. Checking the switching function of the solar control unit... 10 8. Checking the flow rate 9. Shutting down the system... 10 10. Checking gaskets and seals 11. Checking the frost protection temperature and the ph value of the heat transfer medium... 10 12. Checking the thermal insulation of the pipes... 10 13. Checking circulation pumps 14. Cleaning collectors 5

Commissioning, inspection, maintenance Further details regarding the individual steps Cleaning, testing for leaks and filling the solar thermal system Never drain the system with a vacuum pump. Check the system for leaks: The collector in its cold state must be subject to a positive pressure of at least 1.0 bar. At a static head of 10 m, this would result in a system pressure of 2.0 bar. 1. Cover collectors where necessary. Open any installed shut-off gates or valves by hand. Open the non-return valves when using a Solar-Divicon: Flow/return: Turn the thermometer clockwise through 45. 2. Close the shut-off valve of the fill valve and open the drain valve. 3. Flush the system via the return connections. Fill and flush the system with heat transfer medium via the fill valve. Flush using a high-speed pump over an open container and continue until no air remains in the collector system. Correct commissioning can only be guaranteed with a system that is completely free of air. Now close the drain valves on the fill valve, open the shut-off valve and check the system for leaks. Observe the permissible operating pressure. Pressure must not drop for at least half an hour. Notes A heat transfer medium containing glycol can be damaged if it is exposed to temperatures above 170 C for a prolonged period (stagnation). Temperatures in excess of 200 C result in a slow thermal breakdown of the 1.2-propylene glycol that can be recognised by the darkening of the heat transfer medium. Furthermore, it can result in the solar circuit suffering from sludge and hard deposits, particularly in conjunction with other contaminants (cinder, swarf) and air. Ensure that the system is properly cleaned, filled and ventilated after installation. After filling the system with the heat transfer medium, ensure that the system is properly vented and that heat is transferred inside the system, i.e. that longer periods of stagnation are prevented. Blow-off and drain lines must terminate in an open container, that is capable of collecting the total capacity of the collector. 6

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Checking the expansion vessel and the system pressure 1. Drain the system. For this, close the cap valve on the expansion vessel (if installed) and reduce the pressure. 2. If the pre-charge pressure of the expansion vessel is lower than the set value, top up with nitrogen until the pre-charge pressure equals the set value. Static head (top edge of collector to expansion vessel):... m Set pre-charge pressure of the expansion vessel: 0.7 bar + 0.1 x static head in m 0.7 bar + 0.1 x... m =... bar 3. Top-up heat transfer medium until the system pressure is 0.3 to 0.5 bar higher than the set pre-charge pressure of the expansion vessel (create a safety water seal in the expansion vessel). The safety water seal should be 0.005 x liquid content of the complete system, but no less than 3 litres. Liquid content of the system = content of pipes + content of collectors + content of the indirect coil of the DHW cylinder and safety water seal for the expansion vessel. Checking the electrical connections Check the tightness of the electrical plug-in connectors and cable grommets; check cables for damage. Starting the heating system Observe operating instructions of installed components. 7

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Ventilating the solar thermal system 1. Open the air vent valve. Vent the circulation pumps. For this, adjust the circulation pumps to their maximum speed, switching the pump ON and OFF several times (a ventilated pump runs almost silently) through a relay test (manual operation). Repeat the ventilation process until the float in the flow meter of the Solar-Divicon holds a constant position when the pump is running (highest pump rate). 3. Repeat the ventilation process after the system has been operational for several days. Note If the system pressure drops, top-up the heat transfer medium in the cold state and ventilate again. 4. Always shut off the air vent valve after ventilation. Note Air can be recognised in the flow rate indicator (float moves). 2. Set required flow rate above output rate of the circulation pump (see following tables for approximate set values). Read the value on the underside of the float. Adjustable flow rates The details in the following tables do not take the pipe pressure drop into account. 8

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Low-flow operation, 25 l/(h m 2 ), Vitosol 300-T Collector area in Throughput in m 2 l/min 2 0.8 3 1.2 4 1.6 5 2.0 6 2.5 7 3.0 8 3.3 9 3.8 10 4.0 11 4.5 12 5.0 13 5.5 14 5.8 15 6.2 16 6.6 17 7.0 18 7.5 19 8.0 20 8.3 24 10.0 30 12.5 36 15.0 40 16.7 High-flow operation, 60 l/(h m 2 ), Vitosol 200-T, 300-T Collector area in Throughput in m 2 l/min 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 24 24 30 30 High-flow operation, 40 l/(h m 2 ), Vitosol 200-T Collector area in m 2 Throughput in l/min 11 7.3 12 8.0 13 8.6 14 9.3 15 10.0 16 10.6 17 11.3 18 12.0 19 12.6 20 13.3 24 16.0 30 20.0 9

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Checking the switching function of the solar control unit Solar control unit installation and service instructions Shutting down the system! Please note To prevent equipment damage, cover the collectors before any work on the components of the solar thermal system begins. Mixing the heat transfer medium with water reduces the frost and corrosion protection. Only flush the system with the specified heat transfer medium. Never mix "Tyfocor LS" with other heat transfer media. Electrically isolate the system (e.g. at a separate MCB/fuse or the main isolator) and safeguard against unauthorised reconnection. Checking the frost protection temperature and the ph value of the heat transfer medium Check the frost protection temperature of the "Tyfocor LS" heat transfer medium with a Viessmann antifreeze tester or the manual refractometer in the solar service case (accessory). Check the ph value using the ph strip in the solar service case (accessory). Checking the thermal insulation of the pipes Check the thermal insulation of the pipes for positioning and damage and adjust if required. Replace any damaged parts. Note The thermal insulation of external pipes must be resistant to temperature and UV rays. The insulation must be protected against attack from small animals and birds (e.g. metal sheath). 10

Parts lists Parts list Vitosol 200-T, type SD2A When ordering spare parts: Quote the part and serial no. (see type plate) and the item no. of the required part (as per this parts list). Obtain standard parts from your local supplier. Parts 001 Vacuum tube, complete 002 Connecting pipe 003 Connecting pipe (short) 004 O-ring 005 Retaining rubber 006 Tube supports 007 Clamping bracket, complete 008 Locking profile, complete 012 Spacer 013 Connecting pipe (long) 014 Profile clip 015 Elbow fitting with support ferrule 016 Thermal insulation cap, complete 017 Support sleeve 018 Mounting bracket, complete 020 U-pipe 025 U-pipe with air vent valve 026 Tube clip 027 O-ring 028 Side cover, l.h. 029 Side cover, r.h. Parts not shown 009 Special grease 021 Installation instructions 022 Dismantling instructions 023 Service instructions 024 Operating instructions 11

Parts lists Parts list Vitosol 200-T, type SD2A (cont.) 001 002 003 004 005 006 007 008 012 013 014 015 016 017 018 020 025 026 027 028 029 12

Parts lists Parts list Vitosol 300-T, type SP3A When ordering spare parts: Quote the part and serial no. (see type plate) and the item no. of the required part (as per this parts list). Obtain standard parts from your local supplier. Parts 001 Heat pipe vacuum tube, complete 002 Tube supports 003 Retaining clip 004 Retaining rubber 005 O-ring 006 U-pipe 007 Clamping bracket, complete 008 Connecting pipe (short) 010 Connecting pipe (long) 011 Elbow fitting with support ferrule 012 Connecting pipe 013 Support sleeve 014 Thermal insulation cap, complete 015 Mounting bracket 016 Fixing pin Parts not shown 009 Special grease 017 Installation instructions 018 Dismantling instructions 019 Service instructions 020 Operating instructions 13

Parts lists Parts list Vitosol 300-T, type SP3A (cont.) 001 002 003 004 005 006 007 008 010 011 012 013 014 015 016 14

Specification Vitosol 200-T, type SD2A 2 m 2 3 m 2 Absorber area m 2 2.01 3.02 Aperture area m 2 2.14 3.23 Optical efficiency η 0 % 78.9 79.1 Heat loss factor k 1 W/(m 2 K) 1.36 1.10 Heat loss factor k 2 W/(m 2 K2 ) 0.0075 0.0076 Thermal capacity c kj/(m 2 K) 10.0 10.1 Max. idle temperature C 295 295 Permiss. operating pressure bar 6 6 Content, heat transfer medium litres 3.8 5.8 Vitosol 300-T, type SP3A 2 m 2 3 m 2 Absorber area m 2 2.00 3.02 Aperture area m 2 2.15 3.23 Optical efficiency η 0 % 80.9 80.4 Heat loss factor k 1 W/(m 2 K) 1.37 1.33 Heat loss factor k 2 W/(m 2 K2 ) 0.0068 0.0067 Thermal capacity c kj/(m 2 K) 8.5 8.4 Max. idle temperature C 273 273 Permiss. operating pressure bar 6 6 Content, heat transfer medium litres 1.2 1.8 Solar-Divicon (accessory) Safety valve Max. operating temperature Permiss. operating pressure 6 bar, 120 C 120 C 6 bar 15

Specification Heat transfer medium (accessory) The heat transfer medium provided is a liquid based on 1.2-propylene glycol with frost protection down to 28 C. Monitor the operating condition of the medium as part of the annual service of the solar thermal system by the heating contractor. The solar service case (accessory) enables, amongst other things, the checking of the ph value and the frost protection temperature. In some cases the manufacturer of the heat transfer medium may carry out a laboratory test of the medium, subject to arrangement. TYFOROP CHEMIE GmbH Anton-Rée-Weg 7 D - 20537 Hamburg e-mail: info@tyfo.de Internet: www.tyfo.de 16

Certificates Declaration of conformity We, Viessmann Werke GmbH&Co KG, D-35107 Allendorf, declare as sole responsible body, that the products Vitosol 200-T and 300-T conform to the following standards: DIN 1055 EN 12975 to Solar-KEYMARK In accordance with the following directives, these products are designated _: 2006/95/EC 89/336/EEC 97/23/EC Details according to the Pressure Equipment Directive (97/23/EC): Heated pressure equipment Class I according to appendix II, diagram 5 Module A according to appendix III Identification of individual devices with a content of less than 2 litres as assembly according to article 3 (2), subject to the installation of at least one pair The pressure device was tested without fitted equipment (safety assembly). The pressure vessel must be equipped in accordance with current national requirements before installation and commissioning. The product characteristics determined as system values for the Vitosol product as part of EC type testing according to the Efficiency Directive (see specification table) can be used for the energy assessment of heating and ventilation equipment to DIN V 4701-10. Allendorf, 1. December 2008 Viessmann Werke GmbH&Co KG pp. Manfred Sommer 17

18

19

Printed on environmentally friendly, chlorine-free bleached paper Applicability Applies to the following collectors: Vitosol 200-T, type SD2A, 2 m 2 Part no. SK00 857 Vitosol 200-T, type SD2A, 3 m 2 Part no. SK00 858 Vitosol 300-T, type SP3A, 2 m 2 Part no. SK01 430 Vitosol 300-T, type SP3A, 3 m 2 Part no. SK01 431 20 Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Subject to technical modifications.