VIESMANN. Service instructions VITOSOL-F. for contractors. Vitosol-F. For applicability, see the last page GB 3/2009 Please keep safe.

Similar documents
VIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page

VIESMANN. Installation instructions. Gas type conversion to G 31. Safety instructions. Opening the Vitodens. for contractors

Installation and commissioning instructions 255 series and 256 series

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

Operating Instructions

Flamco Flamco-Fill STA Flamco-Fill STM

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Instruction Manual Contact Pressure Vacuum Gauge

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Declaration of Conformity as per Directive 97/23/EC

Operating and maintenance manual Filter and reducing station Series / 1.0

System Pressure Manager Standard & System Pressure Manager Plus

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

PRAHER PLC-MP AQUASTAR MANAUL 2009

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Operating Instructions

Installation and Operation Manual for Solar Systems with KTU R Collectors

ITT RICHTER CHEMIE-TECHNIK

Siphon vessel / Priming aid

DK46 - DK800 Supplementary instructions

80 Litre Suction Oil Drainer

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Budget Range Operators Handbook

OPERATING INSTRUCTIONS

Flowmeter. Original operating manual DFM

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

ENERGY BLADE 3K4. Energy Blade Installation Instructions

11. Spare Parts. applications since applications since

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

FV Flash Vessel Installation and Maintenance Instructions

FlowSol B / B HE * * Manual for the specialised craftsman. Installation Operation Commissioning

Installation and Operating Instructions Bypass Flow Meter DST

Declaration of Conformity as per Directive 97/23/EC

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Safety Valves. Product Information. It s all at Albion

Instruction Manual Differential Pressure Transmitter

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

HERZ-Motorised flow controler

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

CALEFFI. Ball zone valves. series /03 GB

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

A17W49_MASEM_F_EN MANUAL

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

2-port seat valves PN25 with externally threaded connections

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation and Maintenance Instruction Manual

Modular one-piece solar panels. Outstanding heat transfer properties. Exceptional durability and UV stabilised

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Declaration of Conformity as per Directive 97/23/EC

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Operating instructions for KLINGER SCHÖNEBERG ball valves type RK-Chemoball, type RK-Proball and type RK-Ecoball

Expansion vessels for solar systems

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Type overview. R B2 en-gb subject to changes 1

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and Commissioning Manual Solar Stations FlowCon FA Evolution II

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation and Maintenance Instruction Manual

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Overview of types. Technical data. Safety notes

Two-port valves, male threaded, PN25

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

14. Exploded View. Page 68

Type BBS-03, BBS-05, BBS-06, BBS-25

Propane Conversion Kit Instruction

KKT Training Series: ECO Series, Preventative Maintenance

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

OWNER S TECHNICAL MANUAL

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Peak Pressure Indicator MSI-3

Transcription:

Service instructions for contractors VIESMANN Vitosol-F For applicability, see the last page VITOSOL-F 3/2009 Please keep safe.

Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Please note! This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These instructions are exclusively designed for qualified personnel. Work on electrical equipment must only be carried out by a qualified electrician. The system must be commissioned by the system installer or a qualified person authorised by the installer. Regulations Observe the following when working on this system all legal instructions regarding the prevention of accidents, all legal instructions regarding environmental protection, the Code of Practice of relevant trade associations. all current safety regulations as defined by DIN, EN, DVGW, VDE and all locally applicable standards Working on the system Isolate the system from the power supply and check that it is no longer 'live', e.g. by removing a separate fuse or by means of a main isolator. Safeguard the system against unauthorised reconnection. Please note! Electronic modules can be damaged by electrostatic discharges. Touch earthed objects, such as heating or water pipes, to discharge static loads. Repair work! Please note Repairing components that fulfil a safety function can compromise the safe operation of your heating system. Replace faulty components only with original Viessmann spare parts. 2

Safety instructions Safety instructions (cont.) Ancillary components, spare and wearing parts Please note! Spare and wearing parts that have not been tested together with the heating system can compromise its function. Installing non-authorised components and non-approved modifications or conversions can compromise safety and may invalidate our warranty. For replacements, use only original spare parts supplied or approved by Viessmann. 3

Index Index Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance... 5 Further details regarding the individual steps... 6 Parts lists Parts list Vitosol 200-F, 300-F... 11 Specification Vitosol 200-F... 13 Vitosol 300-F... 13 Solar-Divicon (accessory)... 13 Heat transfer medium (accessory)... 13 Certificates Declaration of conformity... 15 4

Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance For further information regarding the individual steps, see the page indicated Commissioning steps Inspection steps Maintenance steps Page 1. Flushing, testing for leaks and filling the solar thermal system... 6 2. Checking the function of the safety equipment 3. Checking the expansion vessel and the system pressure... 7 4. Checking the electrical connections... 7 5. Starting the system... 7 6. Venting the solar thermal system... 8 7. Checking the switching function of the solar control unit... 9 8. Checking the flow rate 9. Shutting down the system... 9 10. Checking gaskets and seals 11. Checking the frost protection temperature and the ph value of the heat transfer medium... 10 12. Checking the thermal insulation of the pipes... 10 13. Checking circulation pumps 14. Cleaning collectors 5

Commissioning, inspection, maintenance Further details regarding the individual steps Flushing, testing for leaks and filling the solar thermal system Never drain the system with a vacuum pump. Check the system for leaks: The collector in its cold state must be subject to a positive pressure of at least 1.0 bar. At a static head of 10 m, this would result in a system pressure of 2.0 bar. 1. Leave collectors covered or cover if necessary. Open any installed shut-off gates or valves by hand. Open the non-return valves when using a Solar-Divicon: Flow/return: Turn the thermometer clockwise through 45. 2. Close the shut-off valve of the fill valve and open the drain valve. 3. Flush the system via the return connections. Fill and flush the system with heat transfer medium via the fill valve. Flush using a high speed pump over an open container and continue until no air remains in the collector system. Correct commissioning can only be guaranteed with a system that is completely free of air. Now close the drain valves on the fill valve, open the shut-off valve and check the system for leaks. Observe the permissible operating pressure. Pressure must not drop for at least 30 minutes. Notes A heat transfer medium containing glycol can deteriorate if it is exposed to temperatures above 170 C for prolonged periods (stagnation). Temperatures in excess of 200 C result in a slow thermal breakdown of the 1,2-propylene glycol that can be recognised by a darkening of the heat transfer medium. Furthermore, it can result in the solar circuit suffering from sludge and hard deposits, particularly in conjunction with other contaminants (cinder, swarf) and air. Ensure that the system is correctly flushed, filled and ventilated after installation. After filling the system with the heat transfer medium, ensure that the system is fully vented and that heat is transferred inside the system. Blow-off and drain lines must terminate in an open container, that is capable of collecting the full collector content. 6

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Checking the expansion vessel and the system pressure 1. Drain the system. For this, close the cap valve on the expansion vessel (if installed) and reduce the pressure. 2. If the pre-charge pressure of the expansion vessel is lower than the set value, top up with nitrogen until the pre-charge pressure equals the set value. Static head (top edge of collector to expansion vessel):... m Set pre-charge pressure of the expansion vessel: 0.7 bar + 0.1 x static head in m 0.7 bar + 0.1 x... m =... bar 3. Top-up heat transfer medium until the system pressure is 0.3 to 0.5 bar higher than the set pre-charge pressure of the expansion vessel (create a safety water seal in the expansion vessel). The safety water seal should be 0.005 x liquid content of the complete system, but no less than 3 litres. Liquid content of the system = content of pipes + content of collectors + content of the indirect coil of the DHW cylinder and safety water seal for the expansion vessel. Checking the electrical connections Check the tightness of the electrical plug-in connectors and cable grommets; check cables for damage. Starting the system Observe operating instructions of installed components. 7

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Venting the solar thermal system 1. Open the air vent valve. Vent the circulation pumps. For this, adjust the circulation pumps to their maximum speed, switching the pump ON and OFF several times (a ventilated pump runs almost silently) through a relay test (manual operation). Repeat the ventilation process until the float in the flow meter of the Solar-Divicon holds a constant position when the pump is running (highest pump rate). 3. Repeat the venting process after the system has been operational for several days. Note If the system pressure drops, top-up the heat transfer medium in the cold state and vent again. 4. Always shut off the air vent valve after venting. Note Air can be recognised in the flow rate indicator (float moves). 2. Set the required flow rate via the pump rate of the circulation pump (see following tables for approximate set values). Check the value underneath the float. Adjustable flow rates Vitosol 200-F, type 5DI Throughput 3 to 4 l/min Vitosol 200-F, 300-F The details in the following tables do not take the pipe pressure drop into account. 8

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) High-flow operation, 40 l/(h m 2 ) Number of Flow rate in l/min collectors 2 3 3 4.5 4 6 5 7.5 6 9.5 7 10.5 8 12.5 9 14 10 15.5 11 17 12 18.5 13 20 14 21.5 15 23.5 Low-flow operation, 15 l/(h m 2 ) Number of Flow rate in l/min collectors 6 3.5 7 4 8 4.5 9 5 10 5.5 11 6.5 12 7 13 7.5 14 8 15 8.5 16 9 18 10.5 20 11.5 Checking the switching function of the solar control unit Solar control unit installation and service instructions Shutting down the system! Please note To prevent equipment damage, cover the collectors before commencing any work on the components of the solar thermal system. Mixing the heat transfer medium with water reduces the frost and corrosion protection. Only flush the system with the specified heat transfer medium. Never mix "Tyfocor LS" with other heat transfer media. Electrically isolate the system (e.g. at a separate MCB/fuse or the main isolator) and safeguard against unauthorised reconnection. 9

Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Checking the frost protection temperature and the ph value of the heat transfer medium Check the frost protection temperature of the "Tyfocor LS" heat transfer medium with a Viessmann antifreeze tester or the manual refractometer in the solar service case (accessory). Check the ph value using the ph strip in the solar service case (accessory). Solar service case operating instructions Checking the thermal insulation of the pipes Check the thermal insulation of the pipes for positioning and damage and adjust if required. Replace any damaged parts. Note The thermal insulation of external pipes must be resistant to temperature and UV rays. The insulation must be protected against attack from small animals and birds (e.g. metal sheath). 10

Parts lists Parts list Vitosol 200-F, 300-F When ordering spare parts: Quote the part and serial no. (see type plate) and the position no. of the required part (as per this parts list). Obtain standard parts from your local supplier. Parts 001 Connection pipe 002 Connection pipe (short) 003 Connection pipe (long) 004 Plug 005 Locking ring fitting with support sleeves 006 Elbow fitting with support sleeves 007 Clamping bracket, complete 008 Connecting part 009 Mounting bracket 010 Spacer plug 011 Retaining bracket 012 O-ring 013 Retaining screws 014 Profile clip 015 Diagonal sealing strip 016 Support sleeve 017 Resilient buffer 018 Mounting bracket Parts not shown 020 Special grease 021 Dismantling instructions 022 Operating instructions 023 Service instructions 025 Installation instructions for sloping roofs (pitched roofs), above roof installation with roof hooks 026 Installation instructions for sloping roofs (pitched roofs), roof integration 027 Installation instructions for flat roofs or freestanding installation 028 Installation instructions for sloping roofs (pitched roofs), above roof installation with rafter anchors 11

Parts lists Parts list Vitosol 200-F, 300-F (cont.) 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 12

Specification Vitosol 200-F Type SV/SH 5DI Absorber area m 2 2.31 4.76 Aperture area m 2 2.33 4.96 Thermal capacity c kj/(m 2 K) 5.35 6.40 Max. idle temperature C 202 185 Permiss. operating pressure bar 6 6 Content, heat transfer medium litres 1.83/2.48 4.2 Vitosol 300-F Type SV/SH Absorber area m 2 2.32 Aperture area m 2 2.33 Thermal capacity c kj/(m 2 K) 5.35 Max. idle temperature C 212 Permiss. operating pressure bar 6 Content, heat transfer medium litres 1.83/2.48 Solar-Divicon (accessory) Safety valve Max. operating temperature Permiss. operating pressure 6 bar, 120 C 120 C 6 bar Heat transfer medium (accessory) The heat transfer medium provided is a liquid based on 1,2-propylene glycol with frost protection down to 28 C. Monitor the operating condition of the medium as part of the annual service of the solar thermal system by the heating contractor. The solar service case (accessory) enables, amongst others, the checking of the ph value and the frost protection temperature. In some cases the manufacturer of the heat transfer medium can carry out a laboratory test of the medium, subject to arrangement. 13

Specification Heat transfer medium (accessory) (cont.) TYFOROP CHEMIE GmbH Anton-Rée-Weg 7 D - 20537 Hamburg e-mail: info@tyfo.de Internet: www.tyfo.de 14

Certificates Declaration of conformity We, Viessmann Werke GmbH & Co KG, D-35107 Allendorf, declare as sole responsible body, that the products Vitosol 200-F and 300-F conform to the following standards: DIN 1055 EN 12975 to solar KEYMARK In accordance with the following directives, these products are designated _: 2006/95/EC 89/336/EEC 97/23/EC Details according to the Pressure Equipment Directive (97/23/EC): Heated pressure equipment Class I according to appendix II, diagram 5 Module A according to appendix III Identification of individual devices with a content of less than 2 litres as assembly according to article 3 (2), subject to the installation of at least one pair The pressure device was tested without fitted equipment (safety assembly). The pressure device must be equipped in accordance with current national regulations prior to installation and commissioning. The product characteristics determined as system values for the Vitosol product as part of EC type testing according to the Efficiency Directive (see specification table) can be used for the energy assessment of heating and ventilation equipment to DIN V 4701-10. Allendorf, 1. March 2009 Viessmann Werke GmbH&Co KG pp. Manfred Sommer 15

Applicability Applicable to the following collectors: Vitosol 200-F, type 5DI part no. 3004 363 Vitosol 200-F, type SV2 part no. 7248 237 Vitosol 200-F, type SH2 part no. 7248 238 Vitosol 200-F, type SV2A part no. 7374 162 Vitosol 200-F, type SH2A part no. 7374 161 Vitosol 200-F, type SV2B part no. 7417 763 Vitosol 200-F, type SH2B part no. 7417 764 Vitosol 300-F, type SV3 part no. 7248 611 Vitosol 300-F, type SH3 part no. 7248 612 Vitosol 300-F, type SV3A part no. 7374 164 Vitosol 300-F, type SH3A part no. 7374 163 Vitosol 300-F, type SV3B part no. 7417 765 Vitosol 300-F, type SH3B part no. 7417 766 16 Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Subject to technical modifications. Printed on environmentally friendly, chlorine-free bleached paper