MSA AUER SavOx MSA AUER SavOx Industry

Similar documents
MSA AUER SSR 90 [K60]

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

MSA AirElite 4h KO2-Trainer 2h

Ultra Elite-H Mask Negative Pressure

Vautex Elite M 1b 3S V CombiAir

Vautex Elite ET Dual SCBA

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

APPLICATION & LIMITATIONS:

Operation manual. K-S30 Chemical Oxygen Self-rescuer. Version No.: rev.01. Issue date:

Vautex Elite ET Dual LVS 600-D

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

USER'S. manual. Ci-30KS S-30 MP1 A CHEMICAL OXYGEN SELF-CONTAINED SELF-RESCUER FOR ESCAPE

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

Ocenco Incorporated. M-20 Self Contained Self Rescuer Instruction Manual

AirElite 4h KO₂ closed circuit breathing apparatus

STAGE I: FORMATION ( )

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Fire Escape Hood OPERATION AND INSTRUCTIONS

Vautex Elite S, Vautex Elite S Expert

User's manual A CHEMICAL OXYGEN SELF-CONTAINED SELF-RESCUER FOR ESCAPE

Operating Manual. PremAire Escape. Self-Contained Compressed Air Breathing Apparatus for Escape. Order No. D /00. MSAsafety.

Sheared Bolts Discovered on JLG Aerial Lift Boom Connections to Platform after Physical Inspection

Optimization of a Proven Technology

Operating Manual. PremAire Combination. Self-Contained Breathing Apparatus for Escape. Order No /01. MSAsafety.com

Type BBS-03, BBS-05, BBS-06, BBS-25

Mod. AirGo backplate. Short Strap exxtreme. Long Strap with Divider 18 D D

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Instructor s Manual for M-20.2 EEBD & M-20.2T Training Model

Airtester HP for compressed air according to EN 12021

OCENCO M-20.2 Self-Contained Self-Rescuer Emergency Escape Breathing Device

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

Breathing apparatus. Compulsory Specification for. Published by Government Notice No. R. 370 (Government Gazette 25040) of 20 March 2003

Respiratory Protective Equipment

Dräger PARAT Escape Hoods

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Respiratory Protection for Producers

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

NARKOVET ANAESTHETIC UNIT

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

ILNAS-EN :2005

DOLOMITE Legacy. Rollator User Manual

Maintenance handbook

OPERATION MANUAL PNEUMATIC VALVES

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Rapid Survival System

r (bar) Air Volume(L) Approval Service Life TPED 15

Getting out safely Our escape solutions FILTERING ESCAPE EQUIPMENT COMPRESSED AIR EQUIPMENT OXYGEN SELF-RESCUER REFUGE CHAMBERS TRAINING & SERVICE

Compressed Airline Breathing Apparatus

ASPECT INSTRUCTIONS Version 1.0

Gas Pressure Regulator HON 300

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

SIDE 16 Sidemount System User Manual

AIRFED 2100 Full Face Breathing Mask

LIGHTWEIGHT TRIWALKER OWNER S HANDBOOK

MMR Air Mask With. with Quick-Connect Hose

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

EMERGENCY BREATHING Military, Commercial & Corporate

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Model XSMKIT. Operations and Instructions WARNING

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Operate Breathing Apparatus

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

60 Minutes Self Contained Self Rescuer. Donning Procedures for Person-Wearable Self Contained Self Rescuer

MF2M Monnier Miniature Compressed Air Filter

Phalanx Alpha Phalanx Beta and Ultra Elite

ST53SD. Self Contained Breathing Apparatus. User Manual

AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

Operating instructions - Translation of the original -

Self-Rescue Equipment and Skill Development for Mine Escape

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Operating Instructions

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

M5400 Operators Manual

for the of and the EM55-1

A18W35_MASE 130_F_EN MANUAL

Purge Star & Ring Purge Systems

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

ML3M Monnier Miniature Compressed Air Lubricator

Yoke Block Instruction Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Instruction manual Divator MKII Face mask

PV4 and PV6 Piston Valves

Safety Data Sheet SDS 105 in compliance with directive (EC) no. 1907/2006

PPE: RESPIRATORY PROTECTION EQUIPMENT

Installation instructions for the Yepp Maxi Easyfit

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Transcription:

Operating Manual MSA AUER SavOx MSA AUER SavOx Industry EN 13794 K/30/S 0736/XX Order No. 10112005/01

MSA AUER GmbH Thiemannstrasse 1 D-12059 Berlin Germany MSA AUER GmbH. All rights reserved

MSA Contents Contents 1 Safety Regulations... 4 1.1 Correct Use... 4 1.2 Liability Information... 5 1.3 Safety and Precautionary Measures... 5 2 Description... 6 2.1 Overview... 6 2.2 Function... 7 2.3 Marking/Certification... 8 2.4 Demonstration and Training Device... 8 3 Use... 9 3.1 Important Escape Rules... 9 3.2 Carrying the Device... 9 3.3 Donning the Device... 10 4 Maintenance and Cleaning... 17 4.1 Maintenance Instructions... 17 4.2 Return of Used Device... 17 4.3 Tightness Test... 18 4.4 Indicator - applies only for SavOx... 18 4.5 Maintenance Intervals... 19 4.6 Documentation... 19 5 Transport regulations... 20 6 Disposal... 20 7 Technical Data... 20 8 Ordering Information... 21 GB SavOx / SavOx Industry 3

Safety Regulations MSA 1 Safety Regulations 1.1 Correct Use The SavOx or SavOx Industry self-rescuer are respiratory protection devices [chemical oxygen apparatus] for self-rescuing which is independent of the ambient atmosphere. It protects the wearer of the devices during escape from a dangerous ambient atmosphere or whilst waiting for rescue from poisonous gases, toxic particles and oxygen depletion. It is to be used exclusively for selfrescue under dangerous conditions and is not intended for long-term use. The SavOx is carried at the belt. The SavOx Industry is carried over the shoulder. The devices described in this operating manual comply with the European Directive 89/686/EEC [PPE Directive]. The device is developed for one mission, used devices must always be replaced, reuse is not permitted. Warning! The device may only be used once and must never be reused. Used or opened devices must be replaced by new devices. It is imperative that this operating manual be read and observed when using the product. In particular, the safety instructions, as well as the information for the use and operation of the product, must be carefully read and observed. Furthermore, the national regulations applicable in the user's country must be taken into account for a safe use. Danger! This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user's life. Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used. Alternative use, or use outside this specification will be considered as non-compliance. This also applies especially to unauthorised alterations to the product and to commissioning work that has not been carried out by MSA or authorised persons. 4 SavOx / SavOx Industry GB

MSA Safety Regulations 1.2 Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided, if it is not used, serviced or maintained in accordance with the instructions in this manual. 1.3 Safety and Precautionary Measures Attention! Chemical Oxygen Escape Devices used in mining may be subject to particular Mining-Regulations that are to be observed. There is an ignition danger in case the device is destroyed and the oxygen generating chemical comes into contact with combustible substances,e.g. coal. Also observe official regulations applicable in the country of use. Attention! Defective devices must not be used! Removed defect devices from service and return them to MSA for inspection. GB SavOx / SavOx Industry 5

Description MSA 2 Description 2.1 Overview 1 10 2 3 9 B A 8 7 4 5 6 Fig. 1 Design of the device A Inhalation 5 Pressure relief valve B Exhalation 6 Waist belt 1 Gas protective goggles 7 Starter 2 Breathing tube with mouthpiece 8 KO 2 -canister 3 Heat exchanger 9 Neck strap 4 Breathing bag 10 Nose clip The device is contained in an enclosed and sealed sturdy stainless steel container. The device includes a chemical canister with potassium hyperoxide [KO 2 ], which is required for the regeneration of the exhaled air. 6 SavOx / SavOx Industry GB

MSA Description After starting the device by pulling out the breathing tube the device it is directly ready for use. During the escape, the device supplies the wearer with breathable air which is prepared in the KO 2 canister. Normally the SavOx is carried at the belt. The SavOx Industry is carried over the shoulder. Both devices can be stored on vehicles. 2.2 Function The device supplies the wearer with oxygen which is created from the chemical potassium hyperoxide [KO 2 ]. In an emergency, the container is opened and the respiratory protection device is taken out. The device has a closed breathing circuit. When in operation, the exhaled air is transferred into the chemical canister with the potassium hyperoxide. The potassium hyperoxide reacts with the humidity and the carbon dioxide of the exhaled air and, at the same time, creates oxygen and heat. The air for inhalation prepared in this way is fed into the breathing bag and is then inhaled again. The amount of resulting oxygen depends on the intensity of respiration. Increased respiration [more carbon dioxide, more humidity] increases the formation of oxygen or vice versa. When the device is used for breathing, the KO 2 canister warms up, as does the inhalation air, gradually. This is normal and indicates the correct operation of the device. The end of oxygen supply is indicated by increase of the inhalation resistance. The device is equipped with a starter which starts automatically when the breathing tube is pulled. After starting it fills additional oxygen into the breathing bag. Warning! The device must only be opened for use! Otherwise humidity from the ambient air can penetrate the open device and affect the performance. Used or opened devices must be replaced by new devices. GB SavOx / SavOx Industry 7

Description MSA 2.3 Marking/Certification The devices are classified according to EN 13794 and marked with the type [code letter] and nominal duration [minutes]. The type, nominal duration and referenced standard are marked on the device. The device is marked as follows: Marking Device upper side bottom side MSA AUER SavOx MSA AUER SavOx Industry MSA AUER MSA AUER Serial No. Date of manufacture SavOx EN 13794 K/30/S Serial No. Date of manufacture SavOx Industry EN 13794 K/30/S Marine equipment directive: 96/98/EC Approved by SOLAS 74/88 Section II-2/13, latest version. 0736/XX 2.4 Demonstration and Training Device There are different demonstration and training devices for the SavOx Industry TR and SavOx TR. The demonstration and training device can be used for demonstration and practise of wearing and breathing without using a chemical canister. The inhalation air is taken from the ambient air and the exhalation air is expelled outside. The demonstration and training device is comparable in size, weight, external construction, handling and breathing resistance to the emergency use devices. To distinguish it from the emergency use devices, the demonstration and training device has marked blue. For the demonstration and training device the breathing air is taken from the ambient atmosphere, i.e. training must be made in environments free from contamination. 8 SavOx / SavOx Industry GB

MSA Use 3 Use 3.1 Important Escape Rules The devices protects the wearer during escape from a dangerous ambient atmosphere. During the escape, the following rules must always be observed: 1. Stay calm! 2. Choose the shortest route to safe ambient air! 3. Breathe calmly! Extra air will be consumed if breathing is fast and irregular. 4. Do not damage or compress the breathing bag, otherwise lifesaving oxygen may be lost! 5. The mouthpiece must be tight between teeth and lips and be tightly enclosed with the lips. 3.2 Carrying the Device The device must always be available for emergencies. The device can be put into operation with a few simple hand movements in about 20 seconds. Carrying the SavOx (1) Pull the waist belt through the belt loops. (2) Close the belt. Carrying the SavOx Industry (1) Clip the snap hook of the shoulder strap into the lifting eye. (2) Close the neck strap. GB SavOx / SavOx Industry 9

Use MSA 3.3 Donning the Device Donning the SavOx Opening the Container (1) Push the locking lever in the direction of the arrow until the seal breaks and locking device falls off. Removing the Device (2) Grasp container cover with one hand. (3) Pull out the device by the neck strap with the other hand. (4) Discard container cover. Donning the Neck Strap (5) Take off the protective helmet, if used. (6) Place the neck strap around the neck. The valve of the bag must be visible on the front of the bag. Do not adjust neck strap! (7) Put the protective helmet on. 10 SavOx / SavOx Industry GB

MSA Use Detaching the Device (8) Detach device from mouthpiece plug. Activating the Device (9) Grasp breathing tube at the mouthpiece. (10) Fully extend the breathing tube to activate the starter. A drop in pull resistance indicates the starter is initiated. Inserting the Mouthpiece (11) Place mouthpiece into mouth with flange of mouthpiece between teeth and lips. (12) Bite down on the two lugs. (13) Exhale into the device. So the breathing bag is inflated. It might be necessary to unfold the breathingbag by hand. GB SavOx / SavOx Industry 11

Use MSA Fit the Nose Clip (14) Grasp nose clip by rubber pads, pull nose pads apart and fit them onto nose. Removing and Fitting the Goggle Note: Goggle is on the right side of the neck strap. (15) Grasp the goggle strap and pull to remove the goggle from neck strap. (16) Fit the goggle. (17) Tighten goggle straps. Adjusting the Neck Strap (18) Adjust neck strap. Ensure that the head is able to move freely. 12 SavOx / SavOx Industry GB

MSA Use Tying the Waist Belt (19) Tie waist belt and tighten with knot. Donning the SavOx Industry Opening the Container (1) Push the locking lever in the direction of the arrow until the seal breaks and locking device falls off. Removing the Device (2) Grasp container cover with one hand. (3) Pull out the device by the neck strap with the other hand. (4) Discard container cover. GB SavOx / SavOx Industry 13

Use MSA Donning the Neck Strap (5) Take off the protective helmet, if used. (6) Place the neck strap around the neck. The valve of the bag must be visible on the front of the bag. Do not adjust neck strap! (7) Put the protective helmet on. Detaching the Device (8) Detach device from mouthpiece plug. Activating the Device (9) Grasp breathing tube at the mouthpiece. (10) Fully extend the breathing tube to activate the starter. A drop in pull resistance indicates the starter is initiated. 14 SavOx / SavOx Industry GB

MSA Use Inserting the Mouthpiece (11) Place mouthpiece into mouth with flange of mouthpiece between teeth and lips. (12) Bite down on the two lugs. (13) Exhale into the device. So the breathing bag is inflated. It might be necessary to unfold the breathingbag by hand. Fit the Nose Clip (14) Grasp nose clip by rubber pads, pull nose pads apart and fit them onto nose. Removing and Fitting the Goggle Note: Goggle is on the right side of the neck strap. (15) Grasp the goggle strap and pull to remove the goggle from neck strap. (16) Fit the goggle. (17) Tighten goggle straps. GB SavOx / SavOx Industry 15

Use MSA Adjusting the Neck Strap (18) Adjust neck strap. Ensure that the head is able to move freely. Tying the Waist Belt (19) Tie waist belt and tighten with knot. 16 SavOx / SavOx Industry GB

MSA Maintenance and Cleaning 4 Maintenance and Cleaning 4.1 Maintenance Instructions To maintain readiness for use, the device must be inspected regularly, checked for integrity, tightness and, if necessary, cleaned [do not use metal brushes!]. As the device contains a chemical which is sensitive to moisture, it is packed in an airtight container and is sealed at the factory. The frequency of inspection depends on the device load [ chapter 4.5]. For used and/or opened devices, the chemical canister must always be replaced, reuse is not permitted. Internal checks and any repairs to the devies are to be carried out by the MSA Customer Service or authorized service centers. 4.2 Return of Used Device For return of used or opened devices, observe the following: - Pack the device and components in the device containers only after they have cooled down and are dry. - No organic substances must enter the chemical canisters [e.g. solvents, oils, etc.]. - Observe transport regulations [ chapter 5]. If the complete device cannot be packed in the container, the following procedure is required: - Remove the chemical canister from the device: (1) Therefor loosen the clamp and remove the breathing bag and breathing tube. (2) Pack the chemical canister inside the container and seal with the original locking assembly of the container. Do not use finely cutted filling material. - Place the other components of the device with the closed container in a carefully packed package. - The components must be complete and undamaged. GB SavOx / SavOx Industry 17

Maintenance and Cleaning MSA 4.3 Tightness Test The tightness test of the device is carried out using the MSA tightness tester for chemical oxygen breathing protection apparatus. Detailed descriptions of the structure, function, use and maintenance of the tightness tester can be taken from the relevant operating manual of the tightness tester [ chapter 8]. The tightness test of the device is carried out as follows: (1) Push the device without any straps into the tightness tester in such a way that the cover points towards the door. (2) Close the door and lock. (3) Set timer to 90 s. (4) Create overpressure with the lever, i.e. push the lever downwards until it engages and start the timer at the same time. (5) After 30 seconds, cover the black pointer with the red pointer. (6) After a further 60 seconds, the timer signals the end of the test period. Then read the pressure difference between the red and the black pointers. The device is tight if the black pointer remains in the prescribed pressure range and if the pressure difference is no more than 5 mbar. If the pressure drop is more than 5 mbar, the unit must be replaced. 4.4 Indicator - applies only for SavOx Perform an indicator check to controll if the device must be replaced. The indicator is a circle with two semi-circles, the left side is the indicator, on the right side a comparison colour is shown. A blue colour on the left side indicates a functionable device. A pink colour or colourless indicator on the left side indicates, the device must be replaced. To verify the colours, a comparison colour in pink on the right side is shown. (1) Check the indicator on the left side. (2) Compare the left side with the right side. The colour of the left side must be blue. Otherwise replace the device. Blue / Pink Pink / Pink 18 SavOx / SavOx Industry GB

MSA Maintenance and Cleaning 4.5 Maintenance Intervals National regulation must be observed, e.g. control interval according German Mining Regulation. User specific conditions may require shorter intervals. The service life depends on the type and kind of treatment to which the device were subjected. Intervals 1 Inspection Before and after carrying External visual check: Check, that the seal is intact and that there are no external damages on the device. Annully Tightness check 2 After 3 years 3, 4 Tightness check 2 and complete check 5 of 3% of the representative population of devices which are carried along or stored on vehicles. After 5 years 3 Tightness check and complete check 5 of 3% of the population. After 7 years 3 Tightness check 2 and complete check 5 of 3% of the population. After 9 years Tightness check 2 and complete check 5 of 3% of the population. After 10 years Replace device, use no longer permitted. 1. The intervals are based on the date of manufacture [month/year] on the container. Devices manufactured in the same year are considered as "population" and should be combined for inspection. 2. Tightness test with tightness tester D1118845 or by MSA Customer Service. 3. It is recommended that a service contract with MSA Customer Service is made. 4. If the inventory of devices is less than ten devices the inspection after 3 years is not necessary. A complete inspection of the whole inventory of devices is necessary after 5 years. 5. Complete check = Internal inspection and check. The result will decide whether the device can be used further. 4.6 Documentation MSA recommends keeping a file for each device where the serial numbers, the dates of manufacture and the dates and results of the inspections are recorded. GB SavOx / SavOx Industry 19

Transport regulations MSA 5 Transport regulations Chemical oxygen devices are classified as Dangerous Goods under Class 5.1 with the designation and hazard label "5.1, 3356, oxygen generator, chemical". Regard packing group II. Undamaged and unopened devices can be transported in the packing material supplied with the device or in a different approved method of packing. Damaged and/or opened devices should be welded into a plastic bag and packaged as described in chapter 4.1. Notes concerning the various transport methods can be taken from the EU safety data sheet. 6 Disposal The chemical canister contains strong alkaline and oxidizing substances [potassium hydroxide, potassium carbonate and potassium hyperoxide]. For disposal local regulations are to be observed. 7 Technical Data SavOx / SavOx Industry Weight [total] approx. 2.5 kg Weight [ready for use] approx. 1.5 kg Dimensions height: approx. 220 mm width: approx. 160 mm depth: approx. 110 mm Carrying mode on belt or with carrying strap Carrying mode [during use] in front of chest Storage conditions Normal climate, temperature: -20 C to 40 C Temperature at start -10 C to 50 C Ambient temperature in use -20 C to 50 C Temperature class T1 to T4 Service life max. 10 years [without being used] Breathing resistance Inhalation: 3 mbar Exhalation: 6 mbar Oxygen content more than 21% by volume Carbon dioxide content less than 1% by volume 20 SavOx / SavOx Industry GB

MSA Ordering Information Temperature of inhalation air Service time at escape conditions waiting for rescue 1 8 Ordering Information SavOx / SavOx Industry +30 C to +50 C 30 min [breathing volume 35 l/min] up to 3 h [breathing volume 10 l/min] 1. The actual duration time may deviate from the service time in dependency on the breathing air volume. As such the duration time in relation to a breathing air volume of only 10 l/min [e.g. sitting and waiting for rescue while breathing from the device] extends up to 3 hours. Description Article No. SavOx 10023263 SavOx Industry 10107704 Demonstration and Training Device SavOx TR 10024538 Demonstration and Training Device SavOx Industry TR 10110086 Waist belt - SavOx D1123958 Shoulder strap - SavOx 10029099 Antistatic bag [3 Pcs] - SavOx 10120084 Antistatic bag [3 Pcs] - SavOx Industry 10120086 Carrying strap [5 Pcs] - SavOx Industry 10111722 Tightness Tester for closed devices D1118845 Leak-test Module for Tightness Tester SavOx 10029195 Replacement Pictogram 10110641 GB SavOx / SavOx Industry 21

MSA in Europe [ www.msasafety.com ] Northern Europe Southern Europe Eastern Europe Central Europe Netherlands MSA Nederland Kernweg 20 1627 LH Hoorn Phone +31 [229] 25 03 03 Fax +31 [229] 21 13 40 info.nl@msasafety.com France MSA GALLET Zone Industrielle Sud 01400 Châtillon sur Chalaronne Phone +33 [474] 55 01 55 Fax +33 [474] 55 47 99 info.fr@msasafety.com Poland MSA Safety Poland Sp. z o.o. Ul. Wschodnia 5A 05-090 Raszyn k/warszawy Phone +48 [22] 711 50 00 Fax +48 [22] 711 50 19 info.pl@msasafety.com Germany MSA AUER GmbH Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 0 Fax +49 [30] 68 86 15 17 info.de@msasafety.com Belgium MSA Belgium N.V. Duwijckstraat 17 2500 Lier Phone +32 [3] 491 91 50 Fax +32 [3] 491 91 51 info.be@msasafety.com Great Britain MSA (Britain) Limited Lochard House Linnet Way Strathclyde Business Park BELLSHILL ML4 3RA Scotland Phone +44 [16 98] 57 33 57 Fax +44 [16 98] 74 01 41 info.gb@msasafety.com Sweden MSA NORDIC Kopparbergsgatan 29 214 44 Malmö Phone +46 [40] 699 07 70 Fax +46 [40] 699 07 77 info.se@msasafety.com MSA SORDIN Rörläggarvägen 8 33153 Värnamo Phone +46 [370] 69 35 50 Fax +46 [370] 69 35 55 info.se@msasafety.com Italy MSA Italiana S.p.A. Via Po 13/17 20089 Rozzano [MI] Phone +39 [02] 89 217 1 Fax +39 [02] 82 59 228 info.it@msasafety.com Spain MSA Española, S.A.U. Narcís Monturiol, 7 Pol. Ind. del Sudoeste 08960 Sant-Just Desvern [Barcelona] Phone +34 [93] 372 51 62 Fax +34 [93] 372 66 57 info.es@msasafety.com Czech republic MSA Safety Czech s.r.o. Dolnojircanska 270/22b 142 00 Praha 4 - Kamyk Phone +420 241440 537 Fax +420 241440 537 info.cz@msasafety.com Hungary MSA Safety Hungaria Francia út 10 1143 Budapest Phone +36 [1] 251 34 88 Fax +36 [1] 251 46 51 info.hu@msasafety.com Romania MSA Safety Romania S.R.L. Str. Virgil Madgearu, Nr. 5 Ap. 2, Sector 1 014135 Bucuresti Phone +40 [21] 232 62 45 Fax +40 [21] 232 87 23 info.ro@msasafety.com Russia MSA Safety Russia Походный проезд д.14. 125373 Москва Phone +7 [495] 921 1370 Fax +7 [495] 921 1368 info.ru@msasafety.com Austria MSA AUER Austria Vertriebs GmbH Modecenterstrasse 22 MGC Office 4, Top 601 1030 Wien Phone +43 [0] 1 / 796 04 96 Fax +43 [0] 1 / 796 04 96-20 info.at@msasafety.com Switzerland MSA Schweiz Eichweg 6 8154 Oberglatt Phone +41 [43] 255 89 00 Fax +41 [43] 255 99 90 info.ch@msasafety.com European International Sales [Africa, Asia, Australia, Latin America, Middle East] MSA Europe Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 0 Fax +49 [30] 68 86 15 58 info.de@msasafety.com