MSA AirElite 4h KO2-Trainer 2h

Similar documents
MSA AUER SavOx MSA AUER SavOx Industry

Ultra Elite-H Mask Negative Pressure

MSA AUER SSR 90 [K60]

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Vautex Elite M 1b 3S V CombiAir

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

AirElite 4h KO₂ closed circuit breathing apparatus

Vautex Elite ET Dual SCBA

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

Vautex Elite ET Dual LVS 600-D

Optimization of a Proven Technology

Mod. AirGo backplate. Short Strap exxtreme. Long Strap with Divider 18 D D

Vautex Elite S, Vautex Elite S Expert

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Operating Manual. PremAire Escape. Self-Contained Compressed Air Breathing Apparatus for Escape. Order No. D /00. MSAsafety.

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Operating Manual. PremAire Combination. Self-Contained Breathing Apparatus for Escape. Order No /01. MSAsafety.com

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

MMR Air Mask With. with Quick-Connect Hose

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

User Instruction Manual

Safety instructions and operating manual

User Manual. GPL 3000 e. gas detector

Training. Testor Training Manual

testo Leakage detector for refrigerants Instruction manual

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

Instruction Manual Otoflash G171 UV-flash-device for Light Curing

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

Product Information News

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

VERTICAL AIR COMPRESSORS

Technical Data Sheet MF010-O-LC

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Operating Instructions Part No

Instruction Manual Dräger MSI P7 and MSI P7 plus

RAM 4021 Operation Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Fire Escape Hood OPERATION AND INSTRUCTIONS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Columbus Instruments

444C DUAL PERFORMANCE VALUE PACK

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

Operating instructions - Translation of the original -

Instrument Operating Manual

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

ASPECT INSTRUCTIONS Version 1.0

Operating Instructions Part No

PRODUCT NUMBER: A COMPACT AIR A150401

Pressure Regulator. Instructions for Use

Operation manual. K-S30 Chemical Oxygen Self-rescuer. Version No.: rev.01. Issue date:

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

400C & 450C DUAL PERFORMANCE VALUE PACKS

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

Phalanx Alpha Phalanx Beta and Ultra Elite

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

VERTICAL AIR COMPRESSORS

Propane Conversion Kit Instruction

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001

DENAS Reflexo (p.21 40)

SR500 PAPR Copyright 2015 by The S.E.A. Group 1

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

RAM Operation Manual

Propane Conversion Kit Instruction

RAM 4021-DPX Operation Manual

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Installation Instructions

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

air/hydraulic nut riveter heavy-duty vacuum system

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

APPLICATION & LIMITATIONS:

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

ST53SD. Self Contained Breathing Apparatus. User Manual

Instructions for SILEX 1C Mixed bed cartridge filter

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

APC Pressure Reducer with Sensor

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

MODEL NUMBER: AS18-2 USER GUIDE

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

GURU HP Transmitter. User Manual Ver. 1.0 WARNING: requires a Seac GURU Dive Computer Made in Italy

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Installation Instructions

OPERATING INSTRUCTIONS

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

CUT OFF TOOL MODEL: CAT113

MoveRoll Conveyor Operating and Maintenance Manual

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Installation Instructions

200L BELT DRIVEN AIR COMPRESSOR

Transcription:

Operating Manual MSA AirElite 4h KO2-Trainer 2h Training Device Order No. 10151572/01

MSA AUER GmbH Thiemannstrasse 1 D-12059 Berlin Germany MSA AUER GmbH. All rights reserved

MSA Contents Contents 1 Safety Regulations... 4 1.1 Correct Use... 4 1.2 Liability Information... 4 1.3 Safety and Precautionary Measures... 5 2 Description... 6 2.1 Overview... 6 2.2 Converting a Breathing Apparatus into a Training Device... 7 2.3 Function... 8 3 Technical Data... 9 4 Use... 10 4.1 Preparations for Use... 10 4.2 Installing the Canisters... 10 4.3 Information for Training with the MSA AirElite 4h KO2-Trainer 2h... 12 4.4 Monitoring Unit and Consumption Indicator IC-Air... 13 4.5 End of Training Session... 16 5 Maintenance and Service... 17 6 Disposal... 17 7 Converting the MSA AirElite 4h KO2-Trainer 2h into a Breathing Apparatus MSA AirElite 4h... 17 8 Ordering Information... 18 GB MSA AirElite 4h KO2-Trainer 2h 3

Safety Regulations MSA 1 Safety Regulations 1.1 Correct Use The MSA AirElite 4h KO2-Trainer 2h training device - hereafter referred to as training device - is a training device with breathing air regeneration. The MSA AirElite 4h KO2-Trainer 2h is only intended for training the use of breathing apparatus MSA AirElite 4h. It is imperative that this operating manual be read and observed when using the product. In particular, the safety instructions, as well as the information for the use and operation of the product, must be carefully read and observed. Furthermore, the national regulations applicable in the user's country must be taken into account for a safe use. Alternative use, or use outside this specification will be considered as non-compliance. This also applies especially to unauthorised alterations to the product and to commissioning work that has not been carried out by MSA or authorised persons. 1.2 Liability Information Warning! The training device is only used to practise donning and breathing in emergency situations. The training device is NOT a respiratory protection device and may only be used in training sessions. Danger! This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user's life. Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used. MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided, if it is not used, serviced or maintained in accordance with the instructions in this manual. 4 MSA AirElite 4h KO2-Trainer 2h GB

MSA Safety Regulations 1.3 Safety and Precautionary Measures - Do not directly expose the training device to flames. It is not permitted to use the training device during drills where flashover, rollover, backdraft or similar phenomena are simulated. The training device may only be used under controlled conditions and supervision in non-explosive atmospheres. - When starting the training, the temperature of the training device must not be below +5 C. Lower temperatures could endanger the training device user. - The trainer canisters may only be used with the MSA AirElite 4h if the revision number of the IC-Air software is 2.16 or higher and a pre-cooler built 2008 or later is installed (see section 2.2). To check the revision number, see section 4.2, step 8 of the AirElite 4h operating manual. - The trainer canisters are for single use only, it is not permitted to reuse trainer canisters. GB MSA AirElite 4h KO2-Trainer 2h 5

Description MSA 2 Description 2.1 Overview 14 1 2 3 4 15 13 5 12 11 10 6 9 7 8 Fig. 1 Overview 1 Battery (rechargeable) 9 Breathing hose assembly 2 Electronic distributor 10 Air distributor 3 Charging jack 11 Sensor assembly 4 Breathing bag (including surplus valve 12 Mask connector with autostart on reverse) (on left shoulder harness, harness not shown) 5 IC-Air (on the right shoulder strap) 13 Valve control 6 AirElite KO2-Trainer canister (2x) 14 Blower 7 Starter cable connector 15 AirElite KO2-Trainer housing cover 8 Pre-cooler 6 MSA AirElite 4h KO2-Trainer 2h GB

MSA Description 2.2 Converting a Breathing Apparatus into a Training Device To convert an AirElite 4h into a training device, the KO2-Trainer canister set (Fig. 1, pos. 6) and the KO2-Trainer housing cover (Fig. 1, pos. 15) are required. Required for conversion of the AirElite 4h into a training device are IC-Air software with a version number 2.16 or higher and pre-coolers of the new type built 2008 or later. Fig. 2 New type of pre-cooler, display of IC-Air software version The training device contains two trainer canisters (Fig. 1, pos. 6) connected in parallel. These canisters contain potassium hyperoxide required for regenerating the breathing air. The trainer canisters can only be used once and have to be disposed of in accordance with local legislation after use. The trainer canisters permit a training independent of ambient air with a breathing minute volume of 40 l/min for a duration of 2 hours. The electronic control of the IC-Air recognises the trainer canisters, displays this and accordingly calculates the residual capacity in percent. An AirElite full face mask (3 SR AirElite or Advantage AirElite) is necessary to use the training device (see the operating manuals for AirElite full face masks). For a detailed description of the other device components, see operating manual for breathing apparatus MSA AirElite 4h. GB MSA AirElite 4h KO2-Trainer 2h 7

Description MSA 2.3 Function The training device is used to train and instruct users of the MSA AirElite 4h. The training device has comparable use characteristics (weight, breathing resistances as well as warm, dry, oxygen-rich inhalation air). In use, the exhaled air is transferred to the canisters with the potassium hyperoxide. The potassium hyperoxide reacts with the humidity and the carbon dioxide of the exhaled air and, at the same time, develops oxygen and heat. The amount of resulting oxygen depends on respiration intensity. Increased respiration (more carbon dioxide, more humidity) increases the formation of oxygen or vice versa. The breathing air temperature is reduced by coolers. At any given time, more oxygen is developed than consumed. The breathing air provided is dry. The residual capacity is monitored and displayed in percent by the electronic monitoring unit and consumption indicator (IC-Air). In addition to the display, acoustic and visual warnings are produced when reaching a residual capacity of 50 %, 20 % and 5 %. The training device and the IC-Air start automatically as soon as the mask connector of the hose assembly is disconnected from the socket with autostart on the shoulder harness. Warning! Never remove the breathing hose assembly for trial from the socket of the shoulder harness. When removing the breathing hose assembly from the socket on the lefthand shoulder harness the training device starts. After the countdown ends the canisters get started and must be replaced before another use. Warning! Observe temperature limitations for use. The minimum temperature for starting must not be less than +5 C. 8 MSA AirElite 4h KO2-Trainer 2h GB

MSA Technical Data 3 Technical Data Dimensions H x W x D approx. 600 mm x 360 mm x 200 mm (housing) Weight ready for use approx. 15 kg (without mask) Maximum service life Depending on consumption 2 hours at BMV 40 l/min 1) Standby storage and starting +5 C to +40 C Operational temperature (after +5 C to +40 C starting) Maximum storage duration of Standby storage 24 months the trainer canister installed in MSA 3 months AirElite 4h Inhalation Air Temperature up to +50 C Relative humidity 20 % to 40 % Carbon dioxide < 1.0 vol. % (mask not considered) Oxygen up to 90 vol. % 1) BMV - Breathing minute volume according to DIN 58652-2 GB MSA AirElite 4h KO2-Trainer 2h 9

Use MSA 4 Use 4.1 Preparations for Use (1) Remove housing cover. (2) Connect battery to electronic distributor and charge the battery using the charging jack (see operating manual for MSA AirElite 4h). 4.2 Installing the Canisters Fig. 3 Canister bottom (1) Adjust canister holding straps of MSA AirElite 4h to full length. (2) Mark the installation date (month, year) on label on the canister bottom. The canister adjustment position is also shown on the bottom (Top L for installation on the left side, Top R for installation on the right). (3) Start the installation with the left canister: Remove both plugs before installation: Pull out with a slight turn. Important: Always pull on both ears of the plug. Keep the plugs for canister disposal. (4) Push the left canister through the canister holding strap from below. (5) Adjust the canister roughly so that for the left canister Top L is in the top position. Fig. 4 Installation canister 10 MSA AirElite 4h KO2-Trainer 2h GB

MSA Use (6) Push the canister while slightly rotating it all the way to the stop onto the pre-cooler. (7) Adjust the canister so that Top L is in the top position for the left canister. Fig. 5 Fig. 6 Pre-cooler completely inserted in the canister Connecting the upper canister connection (8) Button in the air distributor connection on the upper canister connection, ensure tight fit. (9) Pull canister holding strap tight. (10) Repeat these installation steps for the right canister, with Top R in the top position when adjusting the canister. (11) Check device for tightness (see operating manual for MSA AirElite 4h, chapter 5.11) Attention! For the tightness test the battery must be disconnected from the electronic distributor. Otherwise the chemical canisters are started. GB MSA AirElite 4h KO2-Trainer 2h 11

Use MSA (12) Connect trainer canister starter cable plugs. Fig. 7 Fig. 8 Both canisters installed with connected cable plugs Symbol for battery connection (on electrical distributor) (13) Connect the battery connection cable to the distributor and screw down. (14) Press the test button on IC-Air until LED illuminates red/green, canister display shows 2htr and symbols on the display appear. Brief acoustic signal confirms readiness. Afterwards the device switches off again. (15) Install housing cover and fix with screws. (16) Adjust harness to full length. (17) If applicable, lead seal housing cover and mask connector. (18) Record overhaul. 4.3 Information for Training with the MSA AirElite 4h KO2-Trainer 2h For information on donning and use, see operating manual for MSA AirElite 4h. Attention! The tight fit of the full face mask has to be tested with negative and positive pressure. Attention! When connecting the mask connector to the full face mask, start with exhaling. 12 MSA AirElite 4h KO2-Trainer 2h GB

MSA Use 4.4 Monitoring Unit and Consumption Indicator IC-Air The IC-Air is used for the control and monitoring of the proper functioning of the device, the indication of operational data as well as indicating and signalling hazardous conditions. It also warns when detecting motionlessness of the device user and offers the possibility of activating the alarm manually. Symbol spanner - Calibration mode or error Symbol running man - Evacuation required. Symbol cylinder - Residual capacity in 8 stages Symbol Battery - Battery charging status batt Battery insufficiently charged Fig. 9 IC-Air and display symbols pull 2h canister 4h canister KO2-Trainer 2h Trainer HD Breathing hose assembly not pulled out of socket entirely Symbol Number display - Residual capacity or error code 1 Test button (green), display light 3 LED button (red/green), manual alarm call 2 Display 4 Reset button (yellow) After starting the device and during training with the trainer canisters the IC-Air displays alternately the residual capacity in % and 2htr. GB MSA AirElite 4h KO2-Trainer 2h 13

Use MSA Monitoring and Display Functions - Displaying the IC-Air software version - Identification of the canisters fitted (2h, 4h, trainer canister) - Control of the battery charge level - Digital capacity display in % (from 100 to 0 downwards) - Residual capacity in 8 stages ( Cylinder symbol) - At 50 % residual capacity, a brief acoustic warning signal sounds - Down from 20 % residual capacity, the LED flashes alternately red/green, an interval signal sounds and the retreat symbol ( Running Man ) appears on the display - Down from 5 % residual capacity the LED flashes red, the retreat symbol flashes and a warning sound (rapid beep) is emitted This warning sound can be turned off repeatedly for approx. 90 seconds by pressing the Reset button twice. - At 0 % residual capacity, the warning function continues (LED flashing red, flashing retreat symbol, warning sound). Warning! The training must be finished at 0 % residual capacity. Function Control after Assembly and before Use Press the test button on IC-Air until the LED lights up green and the symbols on the display appear (see MSA AirElite 4h operating manual, Section 4.2, step 8.) Manual Alarm Call The manual alarm call only functions if the device is in operation. Push LED button until the alarm sounds. 14 MSA AirElite 4h KO2-Trainer 2h GB

MSA Use Switching off the Motion Alarm (1) If automatically released and in the pre-alarm stage (3 stages), move the IC-Air. (2) If automatically released and in full alarm, press the reset button twice. (3) If manually activated, press the reset button twice. Illuminating the Display Press Test button. The display is illuminated for about 6 seconds. Error Display in Test Mode Check the function of the training device after assembly and before use. To do so, press the test button until the IC-Air confirms readiness. In case of a malfunction the following error codes are shown: batt Battery defective or insufficiently charged. 1 - Autostart not connected to the distributor. 2 - Starter cable not connected or canister already used. 4 - Blower motor defective, blocked or disconnected. 8 - Temperature sensor in the sensor assembly faulty. 20 - Pressure sensor in the sensor assembly faulty or calibration not successful. 28 - Complete sensor assembly faulty or not connected to the distributor (pressure sensor = 20 + temperature sensor = 8). Several simultaneous errors are shown as a total, (e.g. Starter and blower = 6), except for the error batt. This is shown as a main error, always on its own. In addition to the error code, there is also a visual (red LED) and acoustic (beep) alarm indication. The error codes 50, 70, 75, 80 and 90 indicate a defect in the IC-Air. Return the device to the MSA Customer Service for repair. GB MSA AirElite 4h KO2-Trainer 2h 15

Use MSA 4.5 End of Training Session (1) After use, disconnect the breathing hose assembly from the full face mask. Warning! After an interruption of use, subsequent use of the training device (without reconditioning) is possible within the timeframe of the capacity indication. During the interruption the breathing hose connection must not be plugged into the socket on the left shoulder harness, as then the training device is switched off irreversibly and cannot be reused. If the usage of the training device is interrupted, the capacity reduces by 1 %/min (2h canisters and KO2-Trainer 2h) or 0.7 %/min (4h canisters). (2) Plug the breathing hose assembly into the socket on the left shoulder harness. The training device switches off. An acoustic double signal sounds. (3) Open the waist belt by pressing on the buckle (from the inside) and remove the training device. (4) Deinstall used canisters as soon as possible and seal with both plugs. For deinstallation carry out the installation process described in section 2.2 in reverse order. Warning! Chemical canisters become hot when used. Let canisters cool down before removal or use protective gloves. (5) Hand over the used training device to service for reconditioning. Attention! After ending the training session it is necessary to keep the training device well ventilated until the canisters have cooled down to ambient temperature. 16 MSA AirElite 4h KO2-Trainer 2h GB

MSA Maintenance and Service 5 Maintenance and Service For reconditioning a training device, it is necessary to carry out all required tests, especially the tightness test of the device and the function test. For detailed information on maintenance and service, see AirElite 4h operating manual. For cleaning and disinfection, read and observe the AirElite 4h operating manual. 6 Disposal For disposal local regulations are to be observed. Used canisters contain unused potassium hyperoxide and potassium peroxide. Therefore used canisters are considered hazardous waste, the recommended EU waste code is 160507. Contact a local disposal company to correctly dispose of used trainer canisters. Notes concerning the handling of the chemicals can be taken from the EU safety data sheets. 7 Converting the MSA AirElite 4h KO2-Trainer 2h into a Breathing Apparatus MSA AirElite 4h For conversion, read and observe the AirElite 4h operating manual. GB MSA AirElite 4h KO2-Trainer 2h 17

Ordering Information MSA 8 Ordering Information Description Article No. MSA AirElite 4h KO2-Trainer 2h housing cover 10151861 MSA AirElite 4h KO2-Trainer 2h canister set 2h 10151860 Pre-cooler AirElite 4h (2 pcs.) incl. rubber bushes and clamps 10101077 Rubber bush, pre-cooler, complete with clamps (2 units) 10068517 Lead seals (pack. 25) D1129859 AirElite 4h Air distributor 10068515 Alignment pins with screws (housing cover) (pack. 2) 10068286 Sticker kit housing cover AirElite KO2 - Trainer 10155108 Particle filter (pack. 10) for installation in breathing bag 10068499 Control valve discs (pack. 10) D1118947 O-Ring AirElite 4h (pack of 10) for filter housing 10151749 Battery pack NiMH AirElite 4h replacement 10124201 O-Ring AirElite 4h (pack of 5) for sensor 10151869 Plug (pack of 2) for pre-cooler 10155107 Antimist agent klar-pilot Fluid Super Plus 10032164 Charging cable AirElite 4h for separately charging the battery pack 10068543 AirElite tool kit: 10068546 1 socket wrench 7 mm, 1 Allen key 4 mm, 1 lead seal pliers (neutral) 18 MSA AirElite 4h KO2-Trainer 2h GB

MSA Ordering Information GB MSA AirElite 4h KO2-Trainer 2h 19

MSA in Europe [ www.msasafety.com ] Northern Europe Southern Europe Eastern Europe Central Europe Netherlands MSA Nederland Kernweg 20 1627 LH Hoorn Phone +31 [229] 25 03 03 Fax +31 [229] 21 13 40 info.nl@msasafety.com France MSA GALLET Zone Industrielle Sud 01400 Châtillon sur Chalaronne Phone +33 [474] 55 01 55 Fax +33 [474] 55 47 99 info.fr@msasafety.com Poland MSA Safety Poland Sp. z o.o. Ul. Wschodnia 5A 05-090 Raszyn k/warszawy Phone +48 [22] 711 50 00 Fax +48 [22] 711 50 19 info.pl@msasafety.com Germany MSA AUER GmbH Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 0 Fax +49 [30] 68 86 15 17 info.de@msasafety.com Belgium MSA Belgium N.V. Duwijckstraat 17 2500 Lier Phone +32 [3] 491 91 50 Fax +32 [3] 491 91 51 info.be@msasafety.com Great Britain MSA (Britain) Limited Lochard House Linnet Way Strathclyde Business Park BELLSHILL ML4 3RA Scotland Phone +44 [16 98] 57 33 57 Fax +44 [16 98] 74 01 41 info.gb@msasafety.com Sweden MSA NORDIC Kopparbergsgatan 29 214 44 Malmö Phone +46 [40] 699 07 70 Fax +46 [40] 699 07 77 info.se@msasafety.com MSA SORDIN Rörläggarvägen 8 33153 Värnamo Phone +46 [370] 69 35 50 Fax +46 [370] 69 35 55 info.se@msasafety.com Italy MSA Italiana S.p.A. Via Po 13/17 20089 Rozzano [MI] Phone +39 [02] 89 217 1 Fax +39 [02] 82 59 228 info.it@msasafety.com Spain MSA Española, S.A.U. Narcís Monturiol, 7 Pol. Ind. del Sudoeste 08960 Sant-Just Desvern [Barcelona] Phone +34 [93] 372 51 62 Fax +34 [93] 372 66 57 info.es@msasafety.com Czech republic MSA Safety Czech s.r.o. Dolnojircanska 270/22b 142 00 Praha 4 - Kamyk Phone +420 241440 537 Fax +420 241440 537 info.cz@msasafety.com Hungary MSA Safety Hungaria Francia út 10 1143 Budapest Phone +36 [1] 251 34 88 Fax +36 [1] 251 46 51 info.hu@msasafety.com Romania MSA Safety Romania S.R.L. Str. Virgil Madgearu, Nr. 5 Ap. 2, Sector 1 014135 Bucuresti Phone +40 [21] 232 62 45 Fax +40 [21] 232 87 23 info.ro@msasafety.com Russia MSA Safety Russia Походный проезд д.14. 125373 Москва Phone +7 [495] 921 1370 Fax +7 [495] 921 1368 info.ru@msasafety.com Austria MSA AUER Austria Vertriebs GmbH Modecenterstrasse 22 MGC Office 4, Top 601 1030 Wien Phone +43 [0] 1 / 796 04 96 Fax +43 [0] 1 / 796 04 96-20 info.at@msasafety.com Switzerland MSA Schweiz Eichweg 6 8154 Oberglatt Phone +41 [43] 255 89 00 Fax +41 [43] 255 99 90 info.ch@msasafety.com European International Sales [Africa, Asia, Australia, Latin America, Middle East] MSA Europe Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 0 Fax +49 [30] 68 86 15 58 info.de@msasafety.com