Calibration Procedure

Similar documents
Calibration Procedure

PosiTector UTG, UTG-STD & UTG-ME

Calibration Procedure. PosiTest DFT Combo

Calibration Procedure

DeFelsko PosiTector CMM IS Probe

Calibration Procedure

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

Calibration Procedure

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

Standard Operating Procedure

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Heavy Duty Dissolved Oxygen Meter

8.1 Calibration of gas sensors

! Warning, refer to accompanying documents.

Manual Weighingblock VB2 series and Uniscale

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

REASONS FOR THE DEVELOPMENT

Cygnus Underwater. UT Meters & Spare Parts Sales. Searchwise Aberdeen Ltd Unit 6, Broomiesburn, Ellon Ind Estate, Ellon, Aberdeenshire, UK, AB41 9RD

CCPaSEC. Procedure for the Quality Control Yearly Equipment Check. July 2018 CCPaSEC Quality Control Team

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Dissolved Oxygen/Temp Waterproof Tester

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

DO NOT PRINT THIS PAGE

Location of CC Number if not located with the identification:

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

BAPI Pressure Line of Products - FAQs

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Pneumatic high-pressure controller Model CPC7000

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

Document Number: 302/34000/76 SV/sv Revision: (B) 2009/02/05

M104 Series: Digital Manometer: 0.1 % of Full Scale

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

PTG100 Precision Test Gauge

Technical Procedure for Instrument Calibration and Maintenance

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Standard Recommended Practice. Field Measurement of Surface Profile of Abrasive Blast-Cleaned Steel Surfaces Using a Replica Tape

Introduction. The Shearwater Petrel is an advanced technical diving computer for open and closed circuit divers.

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

VARIABLE TEMPERATURE HOT AIR GUN VALIDATION

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

Do Not Print This Page.

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

FRDS GEN II SIMULATOR WORKBOOK

PIPELINE AND HAZARDOUS MATERIAL SAFETY ADMINISTRATION CYLINDER REQUALIFICATION FACILITY INSPECTION REPORT GENERAL INFORMATION

DX2/DXX Operating Instructions

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Simrad GD10P Extended On-site Maintenance

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Digital Melting Point Apparatus

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

Liquid Handling Systems

Pneumatic high-pressure controller Model CPC7000

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Digital Vacuum Regulator

ali-q TM Gravimetric Verification Procedure

GE Measurement & Control

R&A Rules Limited and United States Golf Association

USER GUIDE USER GUIDE

DIGITAL AUTOMATIC TYRE INFLATOR

CHECK LINE BY ELECTROMATIC DTMB & DTMX. Calibration Instructions

1. Scope: This document describes the procedure for verifying the performance of vaccine vial monitors.

ANALOG PRESSURE GAUGE

PQI Model 301 & 300Test Block Procedure

SCF Softball Club Scoreboard Controller Operation

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Unaxis PECVD. SiH4 (5% in He)

Model of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer

Nuclear Associates

Equipment Accuracy / Selection

PRESSURE-TEMPERATURE RELATIONSHIP IN GASES

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Relative Humidity Calibration Kit

DANGER WARNING IMPORTANT

Model 130M Pneumatic Controller

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

MP15 Jockey Pump Controller

IN-PLACE DENSITY OF BITUMINOUS MIXES USING THE NUCLEAR MOISTURE-DENSITY GAUGE FOP FOR WAQTC TM 8

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

User-Calibration of Mettler AT200 Analytical Balance

Operating Instructions Part No

StockWeigh 500 D3632 US-B

LM6 LEATHER MOISTURE METER

Surface Texture Gage study in the qs-stat Measurement System Analysis Module

Transcription:

Management Procedure 2530 Revision: F Date Issued: October 23, 1998 Date Revised: January 13, 2015 Calibration Procedure DeFelsko Corporation PosiTector 6000 F PosiTector 6000 FS PosiTector 6000 FRS PosiTector 6000 FXS PosiTector 6000 SPFS Coating Thickness Gages Table of Contents 1 Introduction and UUC Performance Requirements... 2 Table 1-1 Measurement Ranges... 2 2 Measurement Standards and Support Equipment Performance Requirements... 2 Table 2-1 UUC Accuracy Requirements and Description... 2 Table 2-2 Minimum Use Specification... 2 Table 2-3 Actual Equipment Specification... 3 Table 2-4 Calibration Environmental and Warm-up Requirements... 3 3 Preliminary Operations... 3 4 Calibration Process... 3 Figure 4-1 Measurement Area for Square or Round Reference Standards... 4 5 Performance Requirements... 5 Table 5-1 Performance Requirements and Calibration Data for PosiTector 6000 F, FS, FRS, FXS & SPFS... 5 Management Procedure Change Notice... 6 Management Procedure 2530 Rev. F Page 1 of 6

1 Introduction and UUC Performance Requirements 1.1 This procedure describes the calibration of DeFelsko Corporation PosiTector 6000 F, 6000 FS, 6000 FRS, 6000 FXS and 6000 SPFS probes and gages. All gages have the following ranges: Table 1-1 Measurement Ranges Gage Measurement Range 6000 F 6000 FS 6000 FRS 6000 FXS 6000 SPFS 0-1500 microns (0-60 mils) 1.2 The unit being calibrated will be referred to as the UUC (unit-under-calibration). 2 Measurement Standards and Support Equipment Performance Requirements 2.1 The UUC accuracy requirements are based upon the published UUC performance specifications. 2.2 The test uncertainty ratio applied in this Calibration Procedure is 4:1 unless otherwise stated. 2.3 The Minimum-Use-Specifications are the minimum test equipment specifications required to meet all the UUC accuracy requirements and the test uncertainty ratio applied. Table 2-1 UUC Accuracy Requirements and Description UUC Performance Specifications Test Method 6000 F 6000 FS 6000 FRS 6000 FXS 6000 SPFS 0-50 microns (0-2 mils) >50 microns (>2 mils) (1 microns + 1% of reading) (0.05 mils + 1% of reading) (2 microns + 1% of reading) (0.1 mils + 1% of reading) Table 2-2 Minimum Use Specification Range Accuracy 0-50 microns + 0.25 microns (0-2 mils) (+ 0.013 mils) >50 1500 microns + 0.62 microns (>2 60 mils) (+ 0.035 mils) Compared to Reference Standards Management Procedure 2530 Rev. F Page 2 of 6

Equipment Generic Name Coating Thickness Reference Standards Table 2-3 Actual Equipment Specification Range Accuracy Manufacturer/Model # s Applicable 75-1500 microns 0.43 microns DeFelsko Corporation, (3-60 mils) ( 0.017 mils) STD-S1 Caution: The instructions in this Calibration Procedure relate specifically to the equipment and conditions listed in Section 2. If other equipment is substituted, the information and instructions must be interpreted accordingly. Table 2-4 Calibration Environmental and Warm-up Requirements Measurement Standards & Support Equipment Temperature: 23 5 C. Environmental Requirements: Relative Humidity: Less than 95% Measurement Standards & Support Equipment Warm-up and Stabilization Requirements: Not Required 3 Preliminary Operations Note: Review the entire document before starting the calibration process. 3.1 Visually inspect the measurement face of the probe for signs of damage or excessive wear, this could impact probe accuracy. 3.2 Gage Reset: For bodies with serial numbers after 700000; when the unit is powered down, simultaneously hold the + and middle buttons until the reset symbol (2 arrows) appears. All other bodies press and hold the + button. Caution: Be sure to keep the probe well away from any metal surface during the RESET process. 3.3 Probe Zero Calibration Adjustment 3.3.1 Select the Main Menu ZERO function and measure the uncoated Reference Standard. One measurement is sufficient. 3.3.2 Measure the zero plate again. If the reading is within +/- 1.0 microns (+/- 0.05 mils), proceed to section 4, otherwise repeat the Zero function. 4 Calibration Process Note: Whenever the test requirement is not met, verify the results of each test and take corrective action before proceeding. 4.1 Review the Performance Requirements Table 5-1. Management Procedure 2530 Rev. F Page 3 of 6

Note: The probe calibration may be verified in either normal or high-resolution mode. Accuracy is the same for both modes. 4.2 Record the thickness of the Reference Standards being used and determine the allowed range of readings for the UUC using the calculation methods shown in Table 5-1. 4.3 Use the UUC to take readings of all the reference standards. Verify that the readings are within the allowable limits determined in table 5-1. Record the readings. Note: In taking readings the probe tip shall be centered on point A of the Reference Standard as shown below. Record all digits displayed on the LCD. This may vary depending on the resolution mode. Figure 4-1 Measurement Area for Square or Round Reference Standards 4.4 If readings are either too high or too low it is possible to adjust the readings. To do this simply press the + or - buttons until the reading is within tolerance. This adjustment will modify all subsequent readings and will require you to verify that any previous readings on the uncoated plate and other coated standards are still within tolerance. This adjustment may also be performed on the zero reading. Management Procedure 2530 Rev. F Page 4 of 6

5 Performance Requirements Table 5-1 Performance Requirements and Calibration Data for PosiTector 6000 F, FS, FRS, FXS & SPFS Thickness on Standard Label Min. Reading Allowed Max. Reading Allowed Gage Measurement (microns) (microns) (microns) (microns) A Calculation <50 microns: (A times 0.99) - 1. Round up to the nearest 1 micron. > 50 microns: (A times 0.99) - 2. Round up to the nearest 1 micron. Calculation < 50 microns: (A times 1.01) + 1. Round down to the nearest 1 micron. > 50 microns: (A times 1.01) + 2. Round down to the nearest 1 micron. * For imperial/metric readings convert using 1 mil = 25.4 microns Management Procedure 2530 Rev. F Page 5 of 6

Management Procedure Change Notice Procedure Number: MP 2530 Revision Level: F Date of Change: January 13, 2015 Title: Calibration Procedure for PosiTector 6000 F, FS, FRS, FXS & SPFS Reason for Change: New FXS product Description of Change: Added reference to PosiTector 6000 FXS section 1.1, table 1-1, table 2-1 and table 5-1 I confirm I have read and understand the procedure and the change described above. Printed Name Signature Date Management Form 0010.02-05/1998 Management Procedure 2530 Rev. F Page 6 of 6