Technical Information Deltabar FMD71, FMD72

Similar documents
Technical Information Deltabar FMD71, FMD72

Technical Information Cerabar PMC11, PMC21, PMP11, PMP21

Operating Instructions Deltabar FMD71, FMD72

Cerabar M PMC51, PMP51, PMP55

Deltabar FMD72. Technical Information

Deltabar FMD72. Technical Information

Technical Information Cerabar PMP11, PMP21

Cerabar M PMC41/45, PMP41/45/46/48

Technical Information Deltabar S PMD75, FMD77, FMD78

Pressure Transmitter LHC-M51, PPC-M51

Cerabar M PMC41/45, PMP41/45/46/48

OPTIBAR P 1010 C Technical Datasheet

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

SITRANS P measuring instruments for pressure

Pressure Measurement Single-range transmitters for general applications

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

Cerabar S PMC71, PMP71, PMP75

Differential Pressure Transmiter

Cerabar S PMC71, PMP71/72/75

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Technical Information Ceraphant PTP31B

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Differential Pressure Transmitter deltabar S PMD 25 K for use in Nuclear Power Plants

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pressure Measurement Single-range transmitters for general applications

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

How to specify a product. Process Sensors and Mechanical Instruments

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Expert Hydrostatic Level Transmitters

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Technical Information Ceraphant PTP33B

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Cerabar S PMC71, PMP71, PMP75

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Programmable pressure and temperature transmitters PTM/RS485

ATM - Analog Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

Differential pressure

9700 Transmitter Submersible hydrostatic level transmitter

ATM.1ST/Ex - High Precision Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

Programmable pressure and temperature transmitters PTM/RS485

ATM/Ex - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Hydrostatic Level Measurement waterpilot FMX 160

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Submersible pressure sensor High-performance Model LH-20

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Technical Data. General specifications. Rated operating distance s n 5 mm

Deltabar M PMD55. Technical Information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Torque Tube TB300 Digital Transmitters

Pressure Transmitter cerabar M PMC 41, PMC 45 cerabar M PMP 41, PMP 45

Pressure Measurement Single-range transmitters for general applications

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Cerabar T PMC131, PMP131, PMP135

Programmable Submersible Level Transmitters

Parametrable / Programmable Pressure Transmitter

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Technical Data. Dimensions

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

Technical Data. Dimensions

Pressure transmitter PASCAL Ci4

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Deltapilot M FMB50/51/52/53

Technical Data Sheet MF010-O-LC

Level sensing relative and absolute pressure transmitter type 712

Pressure transmitters EMP 2

Brief Operating Instructions Deltabar M PMD55

DK46 - DK800 Supplementary instructions

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Operating Instructions Cerabar M Deltabar M Deltapilot M

Technical Data. Dimensions

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Operating Instructions Cerabar M PMC51, PMP51, PMP55

Transcription:

TI01033P/00/EN/05.15 71817 Products Solutions Services Technical Information Deltabar FMD71, FMD7 Level measurement with electronic differential pressure Electronic differential pressure transmitter with ceramic and metal sensors Application The Deltabar FMD71/FMD7 is used to measure the differential pressure or level, volume or mass of liquids in pressurized or vacuum vessels Your benefits The electronic differential pressure system eliminates traditional mechanical issues resulting in greater process availability and reliability Safety risks are minimized with the electronic differential pressure system architecture and design Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements, downtime and spare requirements. Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system Continuous health indication of the entire system via HARTbased diagnostic High reproducibility and long-term stability Overload-resistant and function-monitored

Table of contents Document information... 4 Document function... 4 Symbols used... 4 Documentation... 5 Terms and abbreviations... 6 Registered trademarks... 6 Function and system design... 7 Measuring principle - electronic differential pressure measurement... 7 Measuring system... 7 Device features... 8 Product design... 8 System integration... 9 Input... 10 Measured variable... 10 FMD71: measuring range of individual sensors... 10 FMD7: measuring range of individual sensors... 11 Output... 1 Output signal... 1 Signal range 4 to 0 ma... 1 Signal on alarm 4 to 0 ma... 1 Maximum load... 1 Dead time, time constant... 13 Dynamic behavior, current output... 13 Dynamic behavior, HART... 13 Damping... 13 alarm current... 13 Firmware Version... 13 Protocol-specific data... 14 Power supply... 15 Terminal assignment... 15 Supply voltage... 15 Cable entries... 16 Cable specification for transmitter connection... 16 Residual ripple... 16 Influence of power supply... 16 Overvoltage protection... 16 Performance characteristics of ceramic process isolating diaphragm... 17 Reference operating conditions... 17 Influence of the installation position depending on sensor. 17 Resolution... 17 Vibration effects... 17 Application limits... 17 Reference accuracy... 18 Thermal change of the zero output and the output span... 18 Total performance... 19 Long-term stability... 19 Total error... 0 Warm-up period... 0 Performance characteristics of metallic process isolating diaphragm... 1 Reference operating conditions... 1 Influence of the installation position depending on sensor. 1 Resolution... 1 Vibration effects... 1 Application limits... 1 Reference accuracy... Thermal change of the zero output and the output span... Total performance... 3 Long-term stability... 3 Total error... 3 Warm-up period... 3 Installation... 4 Mounting location... 4 Orientation... 4 General installation instructions... 4 Thermal insulation - FMD71 high-temperature version... 4 Installing the sensor modules... 5 Mounting sensor modules with PVDF installation coupling... 5 Installing the transmitter... 5 Sensor and transmitter cable... 6 Environment... 7 Ambient temperature range... 7 Storage temperature range... 7 Climate class... 7 Degree of protection... 7 Vibration resistance... 7 Electromagnetic compatibility... 7 Process... 8 Process temperature range for devices with ceramic process isolating diaphragm FMD71... 8 Process temperature range for devices with metallic process isolating diaphragm FMD7... 9 Pressure specifications... 9 Mechanical construction... 30 Device height... 30 T14 transmitter housing (optional display on the side)... 31 In preparation - T17 transmitter housing (optional display on the side)... 31 Sensor housing... 3 Selecting the electrical connection... 3 FMD71 process connections, internal process isolating diaphragm... 33 FMD71 process connections, internal process isolating diaphragm... 34 FMD71 process connections, internal process isolating diaphragm... 35 FMD71 process connections, flush-mounted process isolating diaphragm... 36 FMD71 process connections, flush-mounted process isolating diaphragm... 37 Endress+Hauser

FMD71 process connections, flush-mounted process isolating diaphragm... 38 FMD71 process connections, flush-mounted process isolating diaphragm... 39 FMD71 process connections, flush-mounted process isolating diaphragm... 4 FMD71 process connections, flush-mounted process isolating diaphragm... 43 FMD71 process connections, flush-mounted process isolating diaphragm... 44 FMD7 process connections, internal process isolating diaphragm... 45 FMD7 process connections, internal process isolating diaphragm... 46 FMD7 process connections, flush-mounted process isolating diaphragm... 47 FMD7 process connections, flush-mounted process isolating diaphragm... 48 FMD7 process connections, flush-mounted process isolating diaphragm... 49 FMD7 process connections, flush-mounted process isolating diaphragm... 50 FMD7 process connections, flush-mounted process isolating diaphragm... 51 Wall and pipe mounting with mounting bracket... 54 Materials in contact with process... 55 Materials not in contact with process... 56 Operability... 59 Operating concept... 59 Local operation... 59 Operating languages... 61 Certificates and approvals... 6 CE mark... 6 Ex approvals... 6 Suitability for hygienic processes... 6 Pressure Equipment Directive (PED)... 6 Other standards and guidelines... 6 CRN approval... 63 Classification of process sealing between electrical systems and (flammable or combustible) process fluids in accordance with ANSI/ISA 1.7.01... 63 Calibration unit... 63 Calibration... 63 Inspection certificates... 63 Ordering information... 65 Scope of delivery... 65 Supplementary documentation... 66 Field of Activities... 66 Technical Information... 66 Operating Instructions... 66 Brief Operating Instructions... 66 Safety Instructions (XA)... 66 Registered trademarks... 66 HARTâ... 66 Endress+Hauser 3

Document information Document function Symbols used The document contains all the technical data on the device and provides an overview of the accessories and other products that can be ordered for the device. Safety symbols Symbol DANGER WARNING CAUTION NOTICE Meaning DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. NOTE! This symbol contains information on procedures and other facts which do not result in personal injury. Electrical symbols Symbol Meaning Symbol Meaning Direct current Direct current and alternating current Protective ground connection A terminal which must be connected to ground prior to establishing any other connections. Alternating current Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. Equipotential connection A connection that has to be connected to the plant grounding system: This may be a potential equalization line or a star grounding system depending on national or company codes of practice. Symbols for certain types of information Symbol Meaning Permitted Procedures, processes or actions that are permitted. Preferred Procedures, processes or actions that are preferred. Forbidden Procedures, processes or actions that are forbidden. Tip Indicates additional information. Reference to documentation Reference to page Reference to graphic Visual inspection 4 Endress+Hauser

Symbols in graphics Symbol Meaning 1,, 3... Item numbers,, Series of steps A, B, C,... Views A-A, B-B, C-C,... Sections Documentation The document types listed are available: In the Download area of the Endress+Hauser website: www.endress.com Download Brief Operating Instructions (KA): getting the 1st measured value quickly KA01105P: The Brief Operating Instructions contain all the essential information from incoming acceptance to initial commissioning. Operating Instructions (BA): your comprehensive reference BA01044P: These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal. Description of Device Parameters (GP): reference for your parameters GP01013P: The document provides a detailed explanation of each individual parameter in the operating menu. The description is aimed at those who work with the device over the entire life cycle and perform specific configurations. Safety Instructions (XA) Safety Instructions (XA) are supplied with the device depending on the approval. These instructions are an integral part of the Operating Instructions. Device Directive Documentation Option 1) FMD71, FMD7 ATEX II 1/G Ex ia IIC T6 Ga/Gb XA00619P BA FMD71, FMD7 ATEX II 1/G Ex d [ia] IIC T6 Ga/Gb XA0060P BC FMD71, FMD7 ATEX II 3G Ex na IIC T6 GC XA0061P BD FMD71, FMD7 IEC Ex ia IIC T6 Ga/Gb XA006P IA FMD71, FMD7 IEC Ex d [ia] IIC T6 Ga/Gb XA0063P IB FMD71, FMD7 CSA General Purpose - CD FMD71, FMD7 NEPSI Ex ia IIC T4/T6 Ga/Gb XA0135P NA FMD71, FMD7 NEPSI Ex d [ia] IIC T4/T6 Ga/Gb XA0135P NB FMD71 FM C/US IS Cl.I Div.1 Gr.A-D, AEx ia, Zone 0,1, XA0068P FA FMD71 FM C/US XP AIS Cl.I Div.1 Gr.A-D, Exd [ia] Zone 0,1, XA0069P FB FMD71 CSA C/US XP Cl.I Div.1 Gr.A-D, Ex d [ia], Zone 0,1, XA00631P CB FMD71 FM C/US NI Cl.I Div. Gr.A-D, Zone XA00668P FD FMD71 CSA C/US NI, Cl.I Div., Gr.A-D Cl.I, Zone, IIC XA00670P CC FMD71 CSA C/US IS Cl.I Div.1 Gr.A-D, Ex ia Zone 0,1, XA00630P CA FMD7 CSA C/US IS Cl.I Div.1 Gr.A-D, Ex ia Zone 0,1, XA0066P CA FMD7 CSA C/US XP Cl.I Div.1 Gr.A-D, Ex d [ia], Zone 0,1, XA0067P CB FMD7 CSA C/US NI, Cl.I Div. Gr.A-D, Zone XA00671P CC Endress+Hauser 5

Device Directive Documentation Option 1) FMD7 FM C/US IS Cl.I Div.1 Gr.A-D, AEx ia, Zone 0,1, XA0064P FA FMD7 FM C/US XP AIS Cl.I Div.1 Gr.A-D, Exd [ia] Zone 0,1, XA0065P FB FMD7 FM C/US NI Cl.I Div. Gr.A-D, Zone XA00669P FD 1) Product Configurator order code for "Approval" The nameplate provides information on the Safety Instructions (XA) that are relevant for the device. Terms and abbreviations Term/abbreviation XA KA BA SD PN MWP OPL LRL URL LRV URV Explanation Document type "Safety Instructions" Document type "Brief Operating Instructions" Document type "Operating Instructions" Document type "Special Documentation" Nominal pressure The MWP (maximum working pressure) for the individual sensors depends on the lowest-rated element, with regard to pressure, of the selected components, i.e. the process connection must be taken into consideration in addition to the measuring cell. Also observe pressure-temperature dependency. For the relevant standards and additional information, see the "Pressure specifications" 9 section. The MWP can also be found on the nameplate. The OPL (over pressure limit = sensor overload limit) for the measuring device depends on the lowest-rated element, with regard to pressure, of the selected components, i.e. the process connection has to be taken into consideration in addition to the measuring cell. Also observe pressure-temperature dependency. For the relevant standards and additional information, see the "Pressure specifications" 9 section. Lower range limit Upper range limit Lower range value Upper range value TD ½Lower range value (LRV) ½ < ½ Upper range value (URV)½ Example with measuring cell HP = 1 000 mbar (15 psi) and measuring cell LP = 400 mbar (6 psi): LRL = 400 mbar (6 psi): Lower range value (LRV) = 300 mbar ( 4.35 psi) Upper range value (URV) = 0 mbar Nominal value (URL) = 1 000 mbar (15 psi) Turn down: TD = URL + ½LRL½/½ URV - LRV ½ 4.66:1 Set span: URV LRV = 300 mbar (4.35 psi) This span is based on the zero point. Turn down Set span and zero-based span. LRL LRV 1 = URV 5 URL 1 Set span Zero-based span 3 Nominal value upper range limit (URL) 4 Nominal measuring range 5 Sensor measuring range 4 3 A0016451 Registered trademarks HARTâ Registered trademark of the HART Communication Foundation, Austin, USA 6 Endress+Hauser

Function and system design Measuring principle - electronic differential pressure measurement Devices with ceramic process isolating diaphragm (Ceraphire ) The ceramic sensor is an oil-free sensor, i.e. the process pressure acts directly on the robust ceramic process isolating diaphragm and causes it to deflect. A pressure-dependent change in capacitance is measured at the electrodes of the ceramic substrate and the process isolating diaphragm. The measuring range is determined by the thickness of the ceramic process isolating diaphragm. Advantages: Guaranteed overload resistance up to 40 times the nominal pressure The ultrapure 99.9 % ceramic (Ceraphire, see also "www.endress.com/ceraphire") ensures: Extremely high chemical durability Less relaxation High mechanical durability Can be used in absolute vacuums up to 150 C (30 F) Small measuring ranges 1 3 4 p A000465 1 Air pressure (relative pressure sensors) Ceramic substrate 3 Electrodes 4 Ceramic process isolating diaphragm Devices with metallic process isolating diaphragm The process pressure deflects the metal process isolating diaphragm of the sensor and a fill fluid transfers the pressure to a Wheatstone bridge (semiconductor technology). The pressure-dependent change in the bridge output voltage is measured and evaluated. Advantages: Can be used for process pressures up to 40 bar (600 psi) Fully welded process isolating diaphragm Small, flush-mounted process connections Significantly reduced thermal effect e.g. compared to diaphragm seal systems with capillaries 1 3 4 p 1 Silicon measuring element, substrate Wheatstone bridge 3 Channel with fill fluid 4 Metal process isolating diaphragm A0016448 Measuring system The FMD71/FMD7 consists of sensor modules and one transmitter. One sensor module measures the hydrostatic pressure (high pressure) and the other one the head pressure (low pressure). The level (electronic differential pressure) is calculated in the transmitter using these two digital values. Endress+Hauser 7

Device features FMD71 FMD7 Field of application Process connections Measuring ranges (differential pressure) Level Differential pressure Thread EN and ASME flanges Flush-mounted hygienic connections from 100 to +100 mbar ( 1.5 to +1.5 psi) to 1 to +40 bar ( 15 to +600 psi) Thread EN and ASME flanges Flush-mounted hygienic connections from 400 to +400 mbar ( 6 to +6 psi) to 1 to +40 bar ( 15 to +600 psi) MWP 1) to 60 bar (900 psi) to 160 bar ( 400 psi) Process temperature limits Ambient temperature range Thread / flange connections: 5 to +15 C ( 13 to +57 F)/ 150 C (30 F) Hygienic connections: 5 to +130 C ( 13 to +66 F), 150 C (30 F) for max. 1 hour 40 to +80 C ( 40 to +176 F) Flush-mounted thread G 1 A, G 1½, G, MNPT / flange connections: 40 to +100 C ( 40 to +1 F)/150 C (30 F) Thread with internal process isolating diaphragm: 40 to +15 C ( 40 to +57 F)/ 150 C (30 F) Hygienic connections: 40 to +130 C ( 40 to +66 F), 150 C (30 F) for max. 1 hour Higher process temperature limits available on request (up to +50 C (480 F)) Reference accuracy of the individual sensors Up to ±0.075 % of the set span PLATINUM version: up to ±0.05 % of the set span Supply voltage Output Options Version for non-hazardous areas: 1 (13) to 45 V DC Ex ia: 1 (13) to 30 V DC 4 to 0 ma with superimposed HART protocol NACE-compliant materials Software pre-configurations 1) MWP: depends on the lowest-rated element, with regard to pressure, of the selected components Product design Level measurement (level, volume and mass) with Deltabar: 8 Endress+Hauser

p LP 1 p1 P P LP HP = p = p1 + p HP A0016449 LP Sensor module LP (low pressure) HP Sensor module HP (high pressure) p Head pressure p1 Hydrostatic pressure 1 Transmitter The FMD71/FMD7 is best suited to level measurement in vessels with pressure overlay or in vacuum vessels and tanks, high distillation columns and other vessels with changing ambient temperatures. The sensor module HP is mounted on the lower measuring connection and the sensor module LP is mounted above the maximum level. The transmitter can be mounted on pipes or walls with the mounting bracket. The sensor signal is transmitted digitally. In addition, sensor temperatures and the individual process pressures present at the respective sensor modules can be individually evaluated and transmitted. NOTICE Incorrect sizing/order of sensor modules In a closed system, please note that the sensor module is affected by the superimposed head pressure (p) in addition to the hydrostatic pressure (p1). This must be taken into account when sizing the sensor module on the high-pressure side (HP). System integration The device can be given a tag name (max. 8 alphanumeric characters). Measuring point (TAG), see additional specifications.: Product Configurator order code for "Identification", option "Z1" Endress+Hauser 9

Input Measured variable Measured process variables Pressure HP and Pressure LP Sensor temperature HP and sensor temperature LP Transmitter temperature Calculated process variables Differential pressure Level (level, volume or mass) FMD71: measuring range of individual sensors The maximum span of the differential pressure corresponds to the URL of the HP sensor. Gauge pressure Nominal value Range limit MWP OPL Vacuum resistance Option 1) lower (LRL) upper (URL) [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] 100 mbar (1.5 psi) 0.1 ( 1.5) +0.1 (+1.5).7 (40.5) 4 (60) 0.7 (10.5) 1C 50 mbar (4 psi) 0.5 ( 4) +0.5 (+4) 3.3 (49.5) 5 (75) 0.5 (7.5) 1E 400 mbar (6 psi) 0.4 ( 6) +0.4 (+6) 5.3 (79.5) 8 (10) 0 1F 1 bar (15 psi) 1 ( 15) +1 (+15) 6.7 (100.5) 10 (150) 0 1H bar (30 psi) 1 ( 15) + (+30) 1 (180) 18 (70) 0 1K 4 bar (60 psi) 1 ( 15) +4 (+60) 16.7 (50.5) 5 (375) 0 1M 10 bar (150 psi) 1 ( 15) +10 (+150) 6.7 (400.5) 40 (600) 0 1P 40 bar (600 psi) 1 ( 15) +40 (+600) 40 (600) 60 (900) 0 1S 1) Product Configurator order code for "Sensor range" Absolute pressure Nominal value Range limit MWP OPL Vacuum resistance Option 1) lower (LRL) upper (URL) [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] 100 mbar (1.5 psi) 0 +0.1 (+1.5).7 (40.5) 4 (60) 0 C 50 mbar (4 psi) 0 +0.5 (+4) 3.3 (49.5) 5 (75) 0 E 400 mbar (6 psi) 0 +0.4 (+6) 5.3 (79.5) 8 (10) 0 F 1 bar (15 psi) 0 +1 (+15) 6.7 (100.5) 10 (150) 0 H bar (30 psi) 0 + (+30) 1 (180) 18 (70) 0 K 4 bar (60 psi) 0 +4 (+60) 16.7 (50.5) 5 (375) 0 M 10 bar (150 psi) 0 +10 (+150) 6.7 (400.5) 40 (600) 0 P 40 bar (600 psi) 0 +40 (+600) 40 (600) 60 (900) 0 S 1) Product Configurator order code for "Sensor range" 10 Endress+Hauser

FMD7: measuring range of individual sensors The maximum span of the differential pressure corresponds to the URL of the HP sensor. Gauge pressure Nominal value Range limit MWP OPL Vacuum resistance 1) Option ) lower (LRL) upper (URL) Silicone oil [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar abs (psi abs )] 400 mbar (6 psi) 0.4 ( 6) +0.4 (+6) 4 (60) 6 (90) 0.01 (0.15) 1F 1 bar (15 psi) 1 ( 15) +1 (+15) 6.7 (100) 10 (150) 0.01 (0.15) 1H bar (30 psi) 1 ( 15) + (+30) 13.3 (00) 0 (300) 0.01 (0.15) 1K 4 bar (60 psi) 1 ( 15) +4 (+60) 18.7 (80.5) 8 (40) 0.01 (0.15) 1M 10 bar (150 psi) 1 ( 15) +10 (+150) 6.7 (400.5) 40 (600) 0.01 (0.15) 1P 40 bar (600 psi) 1 ( 15) +40 (+600) 100 (1500) 160 (400) 0.01 (0.15) 1S 1) The vacuum resistance applies for the measuring cell under reference operating conditions. (see "Reference operating conditions" section) ) Product Configurator order code for "Sensor range" Absolute pressure Nominal value Range limit MWP OPL Vacuum resistance 1) Option ) lower (LRL) upper (URL) Silicone oil [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] [bar abs (psi abs )] 1 bar (15 psi) 0 +1 (+15) 6.7 (100) 10 (150) 0.01 (0.15) H bar (30 psi) 0 + (+30) 13.3 (00) 0 (300) 0.01 (0.15) K 4 bar (60 psi) 0 +4 (+60) 18.7 (80.5) 8 (40) 0.01 (0.15) M 10 bar (150 psi) 0 +10 (+150) 6.7 (400.5) 40 (600) 0.01 (0.15) P 40 bar (600 psi) 1 ( 15) +40 (+600) 100 (1500) 160 (400) 0.01 (0.15) S 1) The vacuum resistance applies for the measuring cell under reference operating conditions. (see "Reference operating conditions" section) ) Product Configurator order code for "Sensor range" Endress+Hauser 11

on off FIELD COMMUNICATION PROTOCOL R Display Sensor on off FIELD COMMUNICATION PROTOCOL R Display Sensor Deltabar FMD71, FMD7 Output Output signal 4 to 0 ma with superimposed digital communication protocol HART 6.0, -wire Operation Internal + LCD External 1) + LCD Internal damp. SW /min HART damp. SW /min HART + E + E A00180 Order code option ) 4 5 8 1) In the case of the T17 transmitter housing, the operating keys are always arranged internally on the electronic insert. ) Product Configurator order code for "Display, operation:" Signal range 4 to 0 ma Signal on alarm 4 to 0 ma Maximum load 3.8 ma to 0.5 ma As per NAMUR NE43 High alarm (factory setting: ma): can be set from 1 to 3 ma Hold measured value: last measured value is held Min. alarm: 3.6 ma In order to guarantee sufficient terminal voltage in two-wire devices, a maximum load resistance R (including line resistance) must not be exceeded depending on the supply voltage U 0 of the supply unit. In the following load diagrams, observe the position of the jumper and the explosion protection: Test RLmax A RLmax [ ] [ ] 1435 1391 117 1174 B Test 783 348 739 304 1 0 30 40 45 U 13 0 30 40 45 U [V] [V] 1 1 3 R U 1 V U 13 V Lmax 3 R 3 ma Lmax 3 ma A Jumper for 4 to 0 ma test signal set to "Non-test" position B Jumper for 4 to 0 ma test signal set to "Test" position 1 Power supply for II 1/ G Ex ia, FM IS, CSA IS Power supply for devices for the non-hazardous area, G Ex d, 3 G Ex na, FM XP, FM NI, CSA XP, CSA dust ignition-proof 3 R Lmax maximum load resistance U Supply voltage A0017533 When operating via a handheld terminal or via a PC with an operating program, a minimum communication resistance of 50 Ω must be taken into account. 1 Endress+Hauser

Dead time, time constant Presentation of the dead time and the time constant: I 100 % 90 % 63 % t 1 t t 3 t A0019786 Dynamic behavior, current output Dead time (t 1 ) [ms] Time constant (T63), t Time constant (T90), t 3 max. 10 10 80 Dynamic behavior, HART Dead time (t 1 ) [ms] Dead time (t 1 ) [ms] + Time constant T63 (= t ) [ms] Dead time (t 1 ) [ms] + Time constant T90 (= t 3 ) [ms] min. 80 400 560 max. 1100 10 1380 Reading cycle Acyclic: max. 3/s, typically 1/s (depending on command # and number of preambles) Cyclic (burst): max. 3/s, typically /s The Deltabar FMD71/FMD7 offers BURST MODE functionality for cyclical value transmission via the HART communication protocol. Cycle time (update time) Cyclic (burst): min. 300 ms Response time Acyclic: min. 330 ms, typically 590 ms (depending on command # and number of preambles) Cyclic (burst): min. 160 ms, typically 350 ms (depending on command # and number of preambles) Damping alarm current A damping affects all outputs (output signal, display): Via onsite display, handheld terminal or PC with operating program, continuous from 0 to 999 s Via DIP switch on the electronic insert, switch position "on" = set value and "off" Factory setting: s Damping can be switched on or off using a switch on the electronic insert. If the switch is on, the time constant can be set via a parameter in the menu and if the switch is off, the output signal is not damped (time constant = 0.0). Configured min. alarm current: Product configurator order code for "Service", option "IA" Firmware Version Description Option 1) 01.00.zz, HART, DevRev01 78 1) Product Configurator order code for "Firmware version" Endress+Hauser 13

Protocol-specific data Manufacturer ID 17 (0x11) Device type code 39 (0x7) HART specification 6.0 Device description files (DTM, DD) HART device variables Supported functions Information and files under: www.endress.com www.hartcomm.org Measured values for PV (primary variable) Differential pressure Level linear (before lin.) Level after linearization table Measured values for SV, TV, QV (second, third and fourth variable) Measured differential pressure Corrected pressure Measured pressure HP Sensor pressure HP Sensor temperature HP Measured pressure LP Sensor pressure LP Sensor temperature LP Level before linearization Tank content Electronics temperature Burst mode Additional transmitter status 14 Endress+Hauser

Power supply LWARNING Electrical safety is compromised by an incorrect connection! In accordance with IEC/EN61010 a separate circuit breaker must be provided for the device. When using the measuring device in a hazardous area, installation must also comply with the relevant national standards and regulations as well as the safety instructions or installation or control drawings. All explosion protection data are given in separate documentation which is available upon request. The Ex documentation is supplied as standard with all devices approved for use in explosion hazardous areas. Devices with integrated overvoltage protection must be grounded. Protective circuits against reverse polarity, HF influences and overvoltage peaks are integrated. Terminal assignment 1 Test 3 8 4... 0mA Test Test 7 6 5 4... 0mA Test 4 1 Housing Supply voltage 3 4 to 0 ma 4 Devices with integrated overvoltage protection are labeled "OVP" (overvoltage protection) here. 5 External ground terminal 6 4 to 0 ma test signal between positive and test terminal 7 Internal ground terminal, minimum supply voltage = 1 V DC, jumper is set as illustrated in the diagram. 8 Jumper for 4 to 0 ma test signal, A0019989 Supply voltage Electronic version Jumper for 4 to 0 ma test signal in "Test" position (delivery status) Jumper for 4 to 0 ma test signal in "Non-test" position 4 to 0 ma HART, version for non-hazardous areas 13 to 45 V DC 1 to 45 V DC Measuring a 4 to 0 ma test signal A 4 to 0 ma test signal may be measured via the positive and test terminal without interrupting the measurement. The minimum supply voltage of the device can be reduced by simply changing the position of the jumper. As a result, operation is also possible with a lower supply voltage. To keep the measured error below 0.1 %, the current measuring device should exhibit an internal resistance of <0.7Ω. Observe the position of the jumper in accordance with the following table. Endress+Hauser 15

Jumper position for test signal Test Description Measurement of 4 to 0 ma test signal via the positive and test terminal: possible. (Thus, the output current can be measured without interruption via the diode.) Delivery status Minimum supply voltage: 13 V DC A001999 Test Measurement of 4 to 0 ma test signal via positive and test terminal: not possible. Minimum supply voltage: 1 V DC A0019993 Cable entries Explosion protection Cable gland Permitted cable diameter Permitted wire cross-sections Standard Ex ia Ex ic Plastic M0x1.5 5 to 10 mm (0. to 0.39 in) 0.5 to.5 mm (0 to 14 AWG) Ex td Ex na FM approval CSA approval Metal M0 x 1.5 7 to 10.5 mm (0.8 to 0.41 in) Cable specification for transmitter connection Endress+Hauser recommends using twisted, shielded two-wire cables. Terminals for core cross-sections 0.5 to.5 mm (0 to 14 AWG) The cable outer diameter depends on the cable entry used. Residual ripple Influence of power supply Overvoltage protection Without influence on 4 to 0 ma signal up to ±5 % residual ripple within the permitted voltage range [according to HART hardware specification HCF_SPEC-54 (DIN IEC 60381-1)] 0.0006 % of URL/1 V Standard version The standard version of the pressure instruments does not contain any special elements to protect against overvoltage ("wire to ground"). Nevertheless the requirements of the applicable EMC standard EN 61000-4-5 (testing voltage 1kV EMC wire/ground) are met. Optional overvoltage protection Devices showing version "NA" in feature 610 "Accessory Mounted" in the order code are equipped with overvoltage protection. Overvoltage protection: Nominal functioning DC voltage: 600 V Nominal discharge current: 10 ka Surge current check î = 0 ka satisfied as per DIN EN 60079-14: 8/0 μs Arrester AC current check I = 10 A satisfied NOTICE Device could be destroyed! Devices with integrated overvoltage protection must be grounded. 16 Endress+Hauser

Performance characteristics of ceramic process isolating diaphragm Reference operating conditions Influence of the installation position depending on sensor As per IEC 60770 Ambient temperature T U = constant, in the range of +1 to +33 C (+70 to +91 F) Humidityj= constant, in the range of 5 to 80 % rh Ambient pressure p A = constant, in the range of860 to 1 060 mbar (1.47 to 15.37 psi) Position of the measuring cell = constant, in the range of horizontal ±1 (see also "Influence of the installation position" section 17) Input of Lo Trim Sensor and Hi Trim Sensor for lower range value and upper range value Zero based span Material of process isolating diaphragm: Al O 3 (aluminum-oxide ceramic, Ceraphire ) Supply voltage: 4 V DC ±3 V DC Load with HART: 50 Ω C 90 A 90 B A0016465 Process isolating diaphragm axis is horizontal (A) Process isolating diaphragm pointing upwards (B) Process isolating diaphragm pointing downwards (C) Calibration position, no measurement error < +0. mbar (+0.003 psi) < 0. mbar ( 0.003 psi) This effect can be corrected using the function to adjust the position (position adjustment) for the differential pressure. Additional position adjustments for individual pressure signals are not available. A position-dependent zero shift can be corrected on the device. Resolution Current output: 1 μa Display: can be set (factory setting: presentation of the maximum accuracy of the transmitter) Vibration effects Test standard Vibration effects IEC 6198-3 Reference accuracy up to 10 to 60 Hz: ±0.35 mm (±0.01 in); 60 to 500 Hz: g Application limits A high ratio between the level and head pressure or between the differential pressure and static pressure can result in large measured errors. A maximum ratio of 1:10 is recommended. For calculation purposes, please use the free "Applicator" calculation tool, which is available online at "www.endress.com/applicator" or on CD-ROM. Endress+Hauser 17

Reference accuracy The reference accuracy contains the non-linearity [DIN EN 6198-3.11] including the pressure hysteresis [DIN EN 6198-3.13] and non-repeatability [DIN EN 6198-3.11] in accordance with the limit point method as per [DIN EN 60770]. Measuring cell Sensor Reference accuracy (A) [%URL for every sensor] Calculated reference accuracy (A Diff ) of the differential pressure Standard Platinum 100 mbar (1.5 psi) Gauge pressure A = A = 50 mbar (3.75 psi) Gauge pressure A = A = 400 mbar (6 psi) Gauge pressure A = A = 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) Gauge pressure/ Absolute pressure A = A = ±0.075 - Calculation (mbar, bar or psi): ±0.15 1) ±0.075 - ±0.15 1) ±0.075 - ±0.15 1) ±0.075 A = ±0.05 ±0.15 1) ±0.075 1) = (A. URL ) + (A. LP URL LP) 100 100 A Diff HP HP Percentage calculation of URL dp:. 100 A Diff [%] = A Diff P Diff A0016468 A0016469 1) For hygienic process connections Ordering information Description Option 1) Platinum Standard D G 1) Product Configurator order code for "Reference accuracy" Thermal change of the zero output and the output span Standard version Measuring cell 10 to +60 C (+14 to +140 F) 0 to 10 C ( 4 to +14 F) +60 to +15 C (+140 to +57 F) Calculated thermal change (T Diff ) of the differential pressure % of the set span for every sensor 100 mbar (1.5 psi) 50 mbar (4 psi) 400 mbar (6 psi) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) T total = ±0.176 T total = ±0.76 Calculation (mbar, bar or psi): T total = ±0.09 T total = ±0.50 = (T. URL ) + (T. LP URL LP) 100 100 T Diff HP HP Percentage calculation of URL dp:. 100 T Diff[%] = T Diff P Diff A0016474 A0016475 18 Endress+Hauser

High temperature version and hygienic version Measuring cell Sensor 10 to +60 C (+14 to +140 F) +60 to +150 C (140 to +30 F) Calculated thermal change (T Diff ) of the differential pressure % of the set span for every sensor 100 mbar (1.5 psi) 50 mbar (4 psi) 400 mbar (6 psi) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) Gauge pressure Gauge pressure Absolute pressure T total = ±0.176 T = ±0.75 T Total = ±0.35 1) T = ±1.5 1) T total = ±0.09 T = ±0.5 T total = ±0.184 1) T = ±0.75 1) T total = ±0.09 T = ±0.75 T total = ±0.184 1) T = ±1.5 1) Calculation (mbar, bar or psi): = (T. URL ) + (T. LP URL LP) 100 100 T Diff HP HP Percentage calculation of URL dp:. 100 T Diff[%] = T Diff P Diff A0016474 A0016475 40 bar (600 psi) Absolute pressure T total = ±0.09 T = ±0.5 T total = ±0.184 1) T = ±0.75 1) 1) For hygienic process connections Total performance The "Total performance" specification comprises the non-linearity including hysteresis, nonreproducibility as well as the thermal change of the zero point. All specifications apply to the temperature range 10 to +60 C (+14 to +140 F). Measuring cell % of URL for every sensor - standard version % of URL for every sensor - hightemperature version % of URL for every sensor - hygienic version Calculated total performance (TP Diff ) of the differential pressure 100 mbar (1.5 psi) 50 mbar (4 psi) 400 mbar (6 psi) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) TP = ±0. TP = ±0.46 TP = ±0.575 Calculation (mbar, bar or psi): TP = ±0.15 TP = ±0.46 TP = ±0.5 = (TP. URL ) + (TP. LP URL LP) 100 100 TP Diff HP HP Percentage calculation of URL dp:. 100 TP Diff [%] = TP Diff P Diff A0016470 A0016471 The "Applicator Sizing Electronic dp" selection tool, available free of charge on the Endress +Hauser web site (www.endress. com/applicator), enables detailed calculations for your respective applications. Long-term stability ' Measuring ranges Sensor Standard version Calculated long-term stability (L Diff ) of the differential pressure 1 year 10 years % of URL for every sensor 100 mbar (1.5 psi) 50 mbar (4 psi) 400 mbar (6 psi) Gauge pressure L = ±0.1 L = ±0.5 1) L = ±0. L = ±0.45 1) Absolute pressure L = ±0.3 L = ±0.55 1) Calculation (mbar, bar or psi): = (L. URL ) + (L. LP URL LP) 100 100 L Diff HP HP A0016463 Percentage calculation of URL dp/year: Endress+Hauser 19

Measuring ranges Sensor Standard version Calculated long-term stability (L Diff ) of the differential pressure 1 year 10 years 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) % of URL for every sensor Gauge pressure L = ±0.05 L = ±0. Absolute pressure L = ±0.1 1) L = ±0.3. 100 L Diff [%] = L Diff P Diff A0016464 1) For hygienic process connections Total error The total error comprises the total performance and long-term stability. All specifications apply to the temperature range 10 to +60 C (+14 to +140 F). Measuring cell % of URL for every sensor - standard version % of URL for every sensor - hightemperature version % of URL for every sensor - hygienic version Calculated total error (TE Diff ) of the differential pressure 100 mbar (1.5 psi) 50 mbar (4 psi) 400 mbar (6 psi) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) TE = ±0.5 TE = ±0.51 TE = ±0.95 Calculation (mbar, bar or psi): TE = ±0. TE = ±0.51 TE = ±0.7 = (TE. URL ) + (TE. LP URL LP) 100 100 TE Diff HP HP Percentage calculation of URL dp:. 100 TE Diff[%] = TE Diff P Diff A001647 A0016473 Warm-up period 4 to 0 ma HART : < 10 s 0 Endress+Hauser

Performance characteristics of metallic process isolating diaphragm Reference operating conditions Influence of the installation position depending on sensor As per IEC 60770 Ambient temperature T U = constant, in the range of +1 to +33 C (+70 to +91 F) Humidityj= constant, in the range of 5 to 80 % rh Ambient pressure p A = constant, in the range of860 to 1 060 mbar (1.47 to 15.37 psi) Position of the measuring cell = constant, in the range of horizontal ±1 (see also "Influence of the installation position" section 1) Input of Lo Trim Sensor and Hi Trim Sensor for lower range value and upper range value Zero based span Process isolating diaphragm material: AISI 316L (1.4435) Filling oil: silicone oil Supply voltage: 4 V DC ±3 V DC Load with HART: 50 Ω C 90 A 90 B A0016465 Process isolating diaphragm axis is horizontal (A) Process isolating diaphragm pointing upwards (B) Process isolating diaphragm pointing downwards (C) Sensor with 1/" thread and silicone oil Calibration position, no measurement error < +4 mbar (+0.06 psi) < 4 mbar ( 0.06 psi) Sensor with thread > 1/" and flanges < +10 mbar (+0.145 psi) The value is doubled for inert oil. < 10 mbar ( 0.145 psi) The value is doubled for inert oil. This effect can be corrected using the function to adjust the position (position adjustment) for the differential pressure. Additional position adjustments for individual pressure signals are not available. A position-dependent zero shift can be corrected on the device. Resolution Current output: 1 μa Display: can be set (factory setting: presentation of the maximum accuracy of the transmitter) Vibration effects Test standard Vibration effects IEC 6198-3 Reference accuracy up to 10 to 60 Hz: ±0.35 mm (±0.01 in); 60 to 500 Hz: g Application limits A high ratio between the level and head pressure or between the differential pressure and static pressure can result in large measured errors. A maximum ratio of 1:10 is recommended. For calculation purposes, please use the free "Applicator" calculation tool, which is available online at "www.endress.com/applicator" or on CD-ROM. Endress+Hauser 1

Reference accuracy The reference accuracy contains the non-linearity [DIN EN 6198-3.11] including the pressure hysteresis [DIN EN 6198-3.13] and non-repeatability [DIN EN 6198-3.11] in accordance with the limit point method as per [DIN EN 60770]. Measuring cell Sensor Reference accuracy (A) [%URL for every sensor] Calculated reference accuracy (A Diff ) of the differential pressure Standard Platinum 400 mbar (6 psi) Gauge pressure A = ±0.15 ±0.3 1) - Calculation (mbar, bar or psi): 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) Gauge pressure/ Absolute pressure A = A = ±0.075 A = ±0.15 1) A = ±0.05 ±0.075 1) = (A. URL ) + (A. LP URL LP) 100 100 A Diff HP HP Percentage calculation of URL dp:. 100 A Diff [%] = A Diff P Diff A0016468 A0016469 1) For hygienic process connections Ordering information Description Option 1) Platinum Standard D G 1) Product Configurator order code for "Reference accuracy" Thermal change of the zero output and the output span ' ' Measuring cell 10 to +60 C (+14 to +140 F) 40 to 10 C ( 40 to +14 F) +60 to +80 C (+140 to +176 F) Calculated thermal change (T Diff ) of the differential pressure % of the set span for every sensor 400 mbar (6 psi) T total = ±0.15 T span = ±0. T zero point = ±0.015 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) T total = ±0.101 T span = ±0.1 T zero point = ±0.01 T total = ±0.43 T span = ±0.4 T zero point = ±0.03 T total = ±0.4 T span = ±0.4 T zero point = ±0.0 Calculation (mbar, bar or psi): = (T. URL ) + (T. LP URL LP) 100 100 T Diff HP HP Percentage calculation of URL dp:. 100 T Diff[%] = T Diff P Diff A0016474 A0016475 Endress+Hauser

Total performance The "Total performance" specification comprises the non-linearity including hysteresis, nonreproducibility as well as the thermal change of the zero point. All specifications apply to the temperature range 10 to +60 C (+14 to +140 F). Measuring cell % of URL for every sensor Calculated total performance (TP Diff ) of the differential pressure 400 mbar (6 psi) TP = ±0.5 TP = ±0.34 1) 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) TP = ±0.15 TP = ±0.5 1) Calculation (mbar, bar or psi): = (TP. URL ) + (TP. LP URL LP) 100 100 TP Diff HP HP Percentage calculation of URL dp:. 100 TP Diff [%] = TP Diff P Diff A0016470 A0016471 1) For hygienic process connections The "Applicator Sizing Electronic dp" selection tool, available free of charge on the Endress +Hauser web site (www.endress. com/applicator), enables detailed calculations for your respective applications. Long-term stability Measuring ranges ' 1 year 5 years 10 years Calculated long-term stability (L Diff ) of the differential pressure % of URL for every sensor 400 mbar (6 psi) L = ±0.035 L = ±0.5 1) L = ±0.14 L = ±0.3 Calculation (mbar, bar or psi): 1 bar (15 psi) L = ±0.00 L = ±0.1 1) L = ±0.08 L = ±0.180 bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) L = ±0.05 L = ±0.05 L = ±0.075 L = ±0.1 1) 40 bar (600 psi) L = ±0.05 L = ±0.1 1) L = ±0.075 L = ±0.100 = (L. URL ) + (L. LP URL LP) 100 100 L Diff HP HP Percentage calculation of URL dp/year:. 100 L Diff [%] = L Diff P Diff A0016463 A0016464 1) For hygienic process connections Total error The total error comprises the total performance and long-term stability. All specifications apply to the temperature range 10 to +60 C (+14 to +140 F). Measuring cell % of URL/year for every sensor Calculated total error (TE Diff ) of the differential pressure 400 mbar (6 psi) TE = ±0.30 Calculation (mbar, bar or psi): 1 bar (15 psi) bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) TE = ±0.0 = (TE. URL ) + (TE. LP URL LP) 100 100 TE Diff HP HP A001647 Percentage calculation of URL dp:. 100 TE Diff[%] = TE Diff P Diff A0016473 Warm-up period 4 to 0 ma HART : < 10 s Endress+Hauser 3

Installation No moisture may enter the housing when installing or operating the device, or when establishing the electrical connection. When measuring in media containing solids, such as dirty liquids, installing separators and drain valves is useful for capturing and removing sediment. If possible, point the cable and connector downwards to prevent moisture (e.g. rain or condensation) from penetrating. Mounting location Orientation General installation instructions Thermal insulation - FMD71 high-temperature version The FMD71/FMD7 is best suited to level measurement in vessels with pressure overlay or in vacuum vessels and tanks, high distillation columns and other vessels with changing ambient temperatures. The sensor module HP is mounted on the lower measuring connection and the sensor module LP is mounted above the maximum level. The transmitter can be mounted on pipes or walls with the mounting bracket. Transmitter: Any orientation. Sensor modules: The orientation can cause a zero point shift. This position-dependent zero point shift can be corrected directly at the device via the operating key, and also in hazardous areas in the case of devices with external operation (position adjustment). Mounting the sensor modules and transmitter is very easy The housings of the sensor modules can be rotated up to 360. The transmitter is freely rotatable in the mounting bracket. The sensor modules and transmitter can be easily aligned when mounted. Your benefits Easy installation due to optimum alignment of housing Easily accessible device operation Optimum readability of the onsite display (optional) Easy pipe installation due to optional alignment of the modules. The FMD71 high-temperature version may only be insulated up to a certain height. The maximum permitted insulation height is indicated on the devices and applies to an insulation material with a heat conductivity 0.04 W/(m x K) and to the maximum permitted ambient and process temperature. The insulation height is not indicated on hygienic connections. Ambient temperature (T A ): 70 C (158 F) Process temperature (T P ): 150 C (30 F) The data were determined under the most critical application "quiescent air". A 1 B A001075 A Ambient temperature B Process temperature 1 Insulation height Insulation material 4 Endress+Hauser

Installing the sensor modules Mounting sensor modules with PVDF installation coupling General installation instructions Due to the orientation of the sensor modules, there may be a shift in the zero point, i.e. when the vessel is empty or partially full, the measured value does not display zero. Always install the sensor module HP below the lowest measuring point. Always install the sensor module LP above the highest measuring point. Do not mount the sensor modules in the filling curtain or at a point in the tank which could be affected by pressure pulses from an agitator. Do not mount the sensor modules in the suction area of a pump. The adjustment and functional test can be carried out more easily if you mount the sensor modules downstream of a shutoff device. LWARNING Risk of damage to process connection! Risk of injury! Sensor modules with PVDF process connections with threaded connection must be installed with the mounting bracket provided! The mounting bracket can be installed on pipes with a diameter of 1¼" to " or on walls. A0017514 The mounting bracket is included in the delivery. Ordering information: Product Configurator order code for "Enclosed accessories", option "PA" or as separate accessory (Part No.: 711016). Dimensions 54. Installing the transmitter The transmitter is installed with the mounting bracket supplied. The mounting bracket can be installed on pipes with a diameter of 1¼" to " or on walls. A001145 The mounting bracket is included in the delivery. If an additional mounting bracket is required, this can be ordered as follows: Product Configurator order code for "Enclosed accessories", option "PA" or as separate accessory (part number: 711016). Dimensions 54. Endress+Hauser 5

Sensor and transmitter cable Description Length Option 1) Sensor cable PE-X 1.8 m (6 ft) BC 4.57 m (15 ft) CC 10.67 m (35 ft) DC 30.48 m (100 ft) FC 45.7 m (150 ft) GC Transmitter cable PE-X 1.8 m (6 ft) BC 4.57 m (15 ft) CC 10.67 m (35 ft) DC 1) Product Configurator order code for "Cable length" Technical data for PE-X cable: Temperature resistance: 40 to +80 C ( 40 to +176 F) Flame resistance: to DIN 6033-1- and DIN EN 5066--5 Halogen-free: to DIN VDE 047 part 815 Oil-resistant: to DIN EN 60811--1 Other: UV-resistant to DIN VDE 076-605 Bending radius: min. 34 mm (1.34 in), permanently installed 6 Endress+Hauser

Environment Ambient temperature range Storage temperature range Climate class Degree of protection Without local display: 40 to +80 C ( 40 to +176 F) WIth local display: 0 to +70 C ( 4 to +158 F) Extended temperature operation range with limitations in optical properties, such as display speed and contrast. 40 to +80 C ( 40 to +176 F) For devices for use in hazardous areas, see Safety Instructions. The device can be used in this temperature range. The values of the specification, such as thermal change, may be exceeded. 40 to +80 C ( 40 to +176 F) Class 4K4H (air temperature: 0 to +55 C ( 4 to +131 F), relative humidity: 4 to 100 %) fulfilled as per DIN EN 6071-3-4 (condensation possible) IP66/68 NEMA 4x/6P IP 68 degree of protection for T17 housing: 1.83 mho for 4 h Vibration resistance Housing Test standard Vibration resistance Aluminum and steel housing IEC 6198-3 Guaranteed for: 10 to 60 Hz: ±0.15 mm (±0.0059 in); 60 to 500 Hz: g in all 3 planes Electromagnetic compatibility Electromagnetic compatibility as per EN 6136 Appendix A and NAMUR Recommendation EMC (NE1). For details, refer to the Declaration of Conformity. Maximum deviation: < 0.5 % of span All EMC measurements were performed with a turn down (TD) = :1. Endress+Hauser 7

Process Process temperature range for devices with ceramic process isolating diaphragm FMD71 Thread and flanges: 5 to +15 C ( 13 to +57 F) Hygienic connections: 5 to +130 C ( 13 to +66 F), 150 C (30 F) for max. 60 minutes High-temperature version: 15 to +150 C (+5 to +30 F); see ordering information, order code 610, option "NB". For saturated steam applications, use a device with a metal process isolating diaphragm, or provide a siphon for temperature isolation when installing. Pay attention to the process temperature range of the seal. See also the following table. Seal Notes Process temperature range Option 1) Threaded connection or flange FKM Viton - 5 to +15 C ( 13 to +57 F)/ 150 C (30 F) ) Hygienic process connections - A FKM Viton FDA 3), 3A Class I, USP Class VI 5 to +15 C (+3 to +57 F) 5 to +150 C (+3 to +30 F) B Kalrez, Compound 4079 - +5 to +15 C (+41 to +57 F) +5 to +150 C (+41 to +30 F) - D NBR FDA 3) 10 to +100 C (+14 to +1 F) - F NBR, low temperature - 40 to +100 C ( 40 to +1 F) - H HNBR 4) FDA 3), 3A Class II, KTW, AFNOR, BAM 5 to +15 C ( 13 to +57 F)/ 0 to +15 C ( 4 to +57 F) G 150 C (30 F) ) EPDM 70 FDA 3) 40 to +15 C ( 40 to +57 F) - J EPDM 91 4) FDA 3), 3A Class II, USP Class VI, DVGW, KTW, W70, WRAS, ACS, NSF61 15 to +15 C (+5 to +57 F)/ 15 to +150 C 150 C (30 F) ) (+5 to +30 F) K FFKM Kalrez 6375 - +5 to +15 C (+41 to +57 F) - L FFKM Kalrez 7075 - +5 to +15 C (+41 to +57 F) - M FFKM Kalrez 61 FDA 3), USP Class VI 5 to +15 C (+3 to +57 F) 5 to +150 C (+3 to +30 F) N Fluoroprene XP40 FDA 3), USP Class VI, 3A Class I +5 to +15 C (+41 to +57 F)/ +5 to +150 C 150 C (30 F) ) (+41 to +30 F) P VMQ silicone FDA 3) 35 to +85 C ( 31 to +185 F) 0 to +85 C ( 4 to +185 F) S The process temperature ranges indicated here refer to the permanent operation of the FMD71. For devices with hygienic process connections, a higher temperature (max. 150 C (30 F)) may be applied for a short period (max. 60 min.) for cleaning purposes. 60 min.) eine höhere Temperatur (max. 150 C (30 F) angewendet werden. 1) Product Configurator order code for "Seal" ) 150 C (30 F) for high temperature version 3) Food-safe FDA 1 CFR 177.600 4) These seals are used for devices with 3A-approved process connections. Applications with changes in temperature Frequent extreme changes in temperatures can temporarily cause measuring errors. Temperature compensation takes place after a few minutes. Internal temperature compensation is faster the smaller the change in temperature and the longer the time interval. 8 Endress+Hauser