Operating and Maintenance Instructions

Similar documents
Operating and Maintenance Instructions

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Respiratory Protection Program 29CFR

ST53SD. Self Contained Breathing Apparatus. User Manual

SOTR Special Operations Tactical Respirator

ACSf/ACSfx Self-contained Breathing Apparatus

INSTRUCTION MANUAL. Doc. no. MN4007E Rev. B - Oct NOVA 1 Abrasive Blasting Helmet 0194 EN14594: Surface Treatment Solutions

AIRFED 2100 Full Face Breathing Mask

A. Evaluation of the written program

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Head Cover BE-12 Series

EN14594: 2005 INSTRUCTION MANUAL

Fire Escape Hood OPERATION AND INSTRUCTIONS

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

MODUL+AIR-2 Airline Breathing Apparatus

Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR

Technical. Datasheet 3M Reusable Half Face Respirator 6000 Series. Main Features. Applications

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

ELSA MUSTER Compressed Air Escape Breathing Apparatus

FLITE COMPRESSED AIR BREATHING APPARATUS I CE0086. AS/NZS1716 : 2003 Lic SAI Global

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

RESPIRATORY PROTECTION

TORNADO T/POWER. Respiratory Protective Systems. Operating and Maintenance Instructions...1. Betriebs- und Wartungsanleitung...7

HAZWOPER 8-Hr Refresher Aug. 20, 2012

Hoods R-Series User Instructions for 3M TM Hoods and and 3M TM Hood , Butyl Rubber

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

453 Series Steam Heated Vaporizing Regulator

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

56 LESLIE HOUGH WAY SALFORD GREATER MANCHESTER M6 6AJ UNITED KINGDOM. Tel: +44 (0) Fax: +44 (0)

3 Choosing the Right Respirator

photo coming soon Product Family Respiratory Replacement Parts Canada (English) Page 1 of 17 Product Numbers & Ordering Information

Respiratory Protective Equipment

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

PROMASK FULL FACE MASK

Respiratory Protection for Producers

BREATHE SAFELY: The Proper Use of Respiratory Protection

RESPIRATORY PROTECTION PROCEDURE

OPERATION MANUAL MPV-623 AIR-FED VIZOR

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask

FLANGED TWO-PIECE BALL VALVES

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

How to Make a Respirator Program and Calculating the Cost

photo coming soon Product Family Respiratory Replacement Parts Corporate - English Page 1 of 23 Product Numbers & Ordering Information

Datasheet. Technical. 3M 6000 Series Reusable Half Masks. Main Features. Applications

MSA AUER SSR 90 [K60]

Technical. Datasheet 3M Reusable Half Face Respirator 7500 Series. Main Features. Applications

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

FLANGED TWO-PIECE BALL VALVES

University of Dayton Respiratory Protection Program 29 CFR

NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT CONCEPT 5 !WARNINGS! 6 RESPIRATOR OPERATION 8

RADROVER REAR RACK INSTALLATION MANUAL

OPERATION MANUAL MPV-627 AIR FED HALF MASK

APPLICATION & LIMITATIONS:

Phalanx Alpha Phalanx Beta and Ultra Elite

Datasheet. Technical. 3M 6000 Series Full Face Masks. Main Features

Operating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

Checklist for care of Respirators

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Respiratory Protection

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PINE HILL FIRE DEPARTMENT

USER MANUAL EMERGENCY ESCAPE BREATHING APPARATUS FENZY BIO-S-CAPE IN ACCORDANCE WITH EN 1146 STANDARD 0194/ /0060

Gemini Owner s Manual

ASPECT INSTRUCTIONS Version 1.0

Australian/New Zealand Standard

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Face Shield MULTIMASK PRO & MULTIMASK

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

PRODUCT NUMBER: A COMPACT AIR A150401

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

CLEANSPACE PRODUCT LIST

DATASHEET SUPPLIER ART.NO. STAXS. ART.NO. F M Aura respirator with shrouded valve 6 x 8 pcs per box STAXS ART.NR.

Pressure Regulator. Instructions for Use

Respiratory Protection

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Respiratory Protection Self Inspection Checklist

"RESPIRATORY PROTECTION AND SAFETY"

IMPORTANT: RECEIVING INSTRUCTIONS:

Respiratory Protection

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Training. Testor Training Manual

Respiratory Protection. Program

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

SURFACE SUPPLIED HARNESS

Product Information News

Leglifter. user instructions. Simple solutions for everyday independence

Respiratory Protection Self-Inspection Checklist

Transcription:

Operating and Maintenance Instructions WARNINGS T/POWER system users must be familiar with workplace hazards prior to using the equipment and must be fully trained in the use of the apparatus. T head-tops must be used with a T/POWER blower. Read this Manual in conjunction with the appropriate User Manual for the air-supplying device prior to using the equipment. T/POWER must be fitted with filters selected from the PF or TF range of filters which are appropriate for the workplace hazard. This product must only be used with Protector-branded filters manufactured by Scott Health and Safety Limited. The use of any other filters will negate the approval and will be likely to reduce the level of protection provided. DO NOT confuse the AS/NZS1716 : 2003 filter markings with filter markings relating to any other standard. Ensure that your selection of respiratory protective devices conform to the requirements AS/NZS1715 : 2009. DO NOT use T2 in confined spaces, oxygen deficient atmospheres (<19.5%), oxygen enriched atmospheres (>23%) or where there is an immediate hazard to life or health. DO NOT use the hood if the ambient temperature is outside of the range -10 C to +50 C. Humidity levels up to 95% RH do not present any operational problems. DO NOT use if the apparatus is damaged. The head-top and air hose must be inspected on every occasion before use to ensure that no damage of any kind is evident, (eg chemical damage, splits or broken stitching), which could cause leakage or reduced levels of protection. A monthly inspection of the apparatus is strongly recommended. Protection will only be obtained if the unit is fitted correctly. Protection levels may be reduced if wind speed exceeds 2 metres per second. In the unlikely event that the air-supplying device fails while in a hazardous area, there may be a depletion of oxygen within the head-top. DO NOT remove the head-top, LEAVE THE AREA IMMEDIATELY. T head-tops can be used in certain explosive and flammable atmospheres when used with T/POWER which is marked as intrinsically safe. It is the employer s responsibility to ensure that the intrinsic safety approval is compatible with the particular environment. At very high work-rates, pressure in the device may become negative at peak inhalation flow. It is unlikely that the requirements for leakage will be achieved if hair, spectacle side arms or clothing intrude into the face-seal. Filters must not be fitted directly to the helmet/hood. 1

SPECIFICATION Description: Classification when used with: Minimum Design Flow Rate when used with: Required Minimum Protection Factor (RMPF) * when used with: Maximum Gas/Vapour Concentration present in the air when used with: Operating Temperature Limits: T/POWER & T2 or T2/AS T/POWER & T2/SU T/POWER T/POWER, with T2 or T2/AS & Particulate Filters T/POWER, with T2 or T2/AS & Gas/Vapour Filters T/POWER, with T2/SU & Particulate Filters T/POWER, with T2/SU & Gas/Vapour Filters T/POWER Full Hood and Cape AS/NZS1716 : 2003 PAPR-P2 AS/NZS1716 : 2003 PAPR-P3 140 L/min Upto 50 x RMPF Upto 10 x RMPF Over 100 x RMPF Upto 10 x RMPF 1000 ppm (by volume) Hood -10 C to +50 C Air-supplying device Refer to User Manual for airsupplying device being used. Material: Hood Polyurethane-coated nylon or polyurethane encased between two layers of textured non-woven polypropylene. Visor Acetate Weight: 290 Grams * According to AS/NZS1715 : 2009 SELECTION OF AIR-SUPPLYING DEVICE The following table identifies which air-supplying device(s) is/are approved for use with each type of T2 head-top: Type of Head-top Type of Air-supplying Device Part No. Description T/POWER T2 Full Hood and Cape - Standard! T2/AS Full Hood and Cape - Anti-static +! T2/SU Full Hood and Cape - Single-use! + Anti-static, surface resistivity of less than 1 x 10 12 Ohms. MARKINGS AND MEANINGS The T2 head-top markings are in conformance with AS/NZS1716, as follows: Marking Meaning SCOTT Manufacturer - Scott Health & Safety T2 Product name - T2 Standard T2/AS Product name - T2 Anti-static T2/SU Product name - T2 Single-use 0086 Certifying body - (BSI) AS/NZS1716 Australian/New Zealand Standard PAPR-P2 Class designation - T2 & T2/AS PAPR-P3 Class designation - T2/SU WEARING Note: Remove the protective transit film from the outside and inside surfaces of the visor before donning. CAUTION: Whilst the materials which may come into contact with the wearer's skin are not known to be likely to cause skin irritation or other adverse effect to health, they may cause allergic reactions in particularly susceptible individuals. 2

1. Pull the face-piece over the head so that the visor is in front of the face. If necessary adjust the Velcro TM over-head strap for a comfortable fit. T2 and T2/AS: adjust the drawstring for a comfortably tight fit around the neck. T2/SU: using the external tab on the hood, pull the seal over the chin until a comfortably tight fit around the neck is achieved. 2. Ensure that hair and clothing are NOT trapped in the seal. 3. Arrange the breathing hose so that it trails freely down the back and is not kinked or looped. 4. For further information, please refer to the User Manual for air-supplying device being used. AFTER USE WARNING: DO NOT remove the face-piece until safely clear of the hazardous area. 1. Remove the hood, disconnect the hose and (if required) use a sponge moistened in warm water to clean and sanitise the face-piece and outer hose. CAUTION: DO NOT use solvent or detergent cleaners as they may cause damage. DO NOT allow water to enter the breathing hose. 2. Care should be taken not to scratch the visor. If the head cover or face-seal is damaged in any way, it should be replaced. MAINTENANCE Carry out a thorough inspection of all component parts before and after each occasion of use, paying particular attention to the exhale valve flap. The valve flap must be replaced annually regardless of condition. Valve flaps in storage have a shelf-life of five years, after which time they should be discarded. Exhalation valve flaps are marked with a code indicating the year of manufacture. The code 07' corresponds to 2007 and a dot is added each year thereafter, so 07.' would equate to 2008. RECORD INSPECTION AND MAINTENANCE DETAILS Record test and maintenance details on the Inspection and Maintenance Record Sheet provided at the back of this Manual. Information recorded usually includes: Name of employer responsible for the apparatus. Make, model number or identification mark of the apparatus, together with a description of any distinguishing features, sufficient to enable clear identification. Date of the inspection/ maintenance together with the name, signature or unique authentication mark of the examiner. Condition of the apparatus, details of any defects found and any remedial action taken. STORAGE When not in use, the equipment should be stored in a clean, dry environment, away from direct heat sources between +10ºC and +30ºC, at a humidity of less than 65% RH. 3

SPARE PARTS Item No. Description Part No. 1 Hood - Standard (Pack of 5) T2/HOOD 1 Hood - Anti-static (Pack of 5) T2/HOOD/AS 1 Hood - Single-use (Pack of 5) T2/HOOD/SU 2 Exhale Valve Flap (Pack of 2) TOR/VALVE 3 Exhale Valve Cover (Pack of 5) 2017146 4 Support Washer (Pack of 5) 2016236 5 Breathing Hose (Pack of 3) T2/HOSE - Tear-off Visor Cover (Pack of 10) KIT96/VP 4

FITTING SPARES To Replace the Hose: 1. Undo the nut on the rear inner hood, remove the support washer from the end of the hose and withdraw the hose. 2. Insert the new hose into the hood, fit the support washer over the end of the hose and secure with the nut. Ensure that both layers of hood fabric are trapped under the washer. To Replace the Exhale Valve: 1. Pull the valve cover from the valve and pull the exhale valve flap from its housing. 2. Fit the replacement valve and check that the valve flap lies flat on the frame. Align the valve cover with the slots in the valve and snap it onto the valve. WARRANTY The products manufactured at our factories in Skelmersdale and Vaasa carry a warranty of 12 months (unless stated otherwise) for parts, labour and return to site. The warranty period runs from the date of purchase by the end user. These products are warranted to be free from defects in materials and workmanship at the time of delivery. SCOTT will be under no liability for any defect arising from wilful damage, negligence, abnormal working conditions, failure to follow the original manufacturer s instructions, misuse or unauthorised alteration or repair. Evidence of purchase date will need to be provided for any claims arising during the warranty period. All warranty claims must be directed through SCOTT Customer Services and in accordance with our sales return procedure. NOTIFIED BODIES Inspec International Limited (0194) 56 Leslie Hough Way, Salford, Greater Manchester, M6 6AJ, England. BSI Product Services (0086) Kitemark House, Maylands Avenue, Hemel Hempstead, HP2 4SQ, England. SAI Global 286 Sussex Street, Sydney, NSW 2000, Australia. Certificate No. SMK1214 5