EUROFLO CULVERT PIPE. Fittings / Pipes

Similar documents
EUROFLO CULVERT PIPE. Fittings / Pipes

StormPRO & SewerPRO. Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications LIGHT WEIGHT

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

FP McCann Tunnels and Shafts 1

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

StormPRO & SewerPRO. Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications LIGHT WEIGHT

(Revised February,2005) CULVERTS, BRIDGES, AND FORDS

CLEANING, INSPECTION, AND TESTING OF SEWERS

Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications

Casing Spacer Technology Leaders

Halsey Taylor Owners Manual STOP!

Inspection Chambers and Covers

DuoSafe. DuoSafe Inch Systems. Larger sizes on request

104 Chamber System Ostendorf. Ostendorf. Chamber System ISO RV-Systém OSMA

Flexible Metal Hose Products

MAKE BOLLARD IMPACT RESISTANT PROTECT FOUNDATIONS RE-USE BOLLARD

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

DREDGING & MINING MEDIUM DUTY ABRASIVES HANDLING HOSE

Suitable Applications Check dams may be appropriate in the following situations: To promote sedimentation behind the dam.

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

European Handball Federation TM EHF Beach Handball Commission

HOW TO DIG A TEST PIT

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

Building Clay Tennis Courts

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

Installation of Nylon Putting NP50

Indiana LTAP Road Scholar Core Course #10 Culvert Drainage. Presented by Thomas T. Burke, Jr., PhD, PE Christopher B. Burke Engineering, Ltd.

Bore-Gard Installation - 1,000 ft. Perry, Oklahoma

Earthen Embankments. turning into larger, more costly repairs. The following. The State Dam Safety Program has inspection

Piloted Non-Return Valves

INSTALLING SUBAQUEOUS PIPE

Inspection Chambers Project

tunnels & shafts brochure

MUELLER. Xp, & Lineseal 350 Butterfly Valves

GUIDE TO LAYING ARTIFICIAL GRASS

Amec Foster Wheeler 2016.

THE PROCESS OF JOINT INTEGRITY

TCML operate and control the 146 Km Railway line from Lake Magadi to Konza.

SECTION [ ] [02730] STABILIZED DECOMPOSED GRANITE SURFACING

Water Storage for Agriculture

ACO External Drainage

Rapidmain Installation Guide

Underground irrigation

Siting and Installation Manual

August Grounds Update

The Spartan Cap Athletic Field System

2016 GPCOG CULVERT PIPE - BID RESULTS

CPM Concrete Drainage Systems. Concrete Pipes Installation Manual

Compressed Air Cleaning Filter Series

Engineered for the extreme PREMIUM SOLID TIRES FOR THE CONSTRUCTION INDUSTRY

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

829S1 Series Flexflo Pilot

TRADESMAN DRAINLAYER

Delta Dual V3 (DMS-164) Installation Instructions For Ground Water Applications T. E. W

SmoothFlex Nominal Bore (SN) Dash Size

Introduction of world construction methods and trends. Franz-Werner Gerressen, Head of Method Development, Tokyo,

INTRODUCTION TO THE MACSTEEL CABLE-LOCK PIPE SYSTEM

Construction Dewatering

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

INTERLOCKED METAL HOSE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

Gravity distribution systems

Geofabrics. Products to improve the playability of your course. golf courses

PowerDrain Section S100K/S200K/S300K ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

Monitoring excavation in the highway

Shade Sails - Installation Tips

CERTIFYING DRAINLAYER

6. Features & Benefits Installation Considerations Jointing Instructions Pipe Sizing Calculations & Tables

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Geopress. Instructions for Use. Year built: from 01/2004 en_int

GUIDANCE FOR THE CREATION OF ARTIFICIAL SETTS

STANDARD OPERATING PROCEDURES

FIBERGLASS MULTI-GARD MULTI-CELL RACEWAY

INSTALLATION, OPERATION & MAINTENANCE GUIDE

Pressure reducing valves Index

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

The Glockemann Pump Site & Installation Guide

DE8410 FIVB Official Beach Volleyball Net

HDPE. Dredging Pipeline

Ecoflex pre-insulated pipe energy efficiency made easy

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Rhode Island

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

INSTALLATION INSTRUCTIONS

MEMO. Schedule 'B' Class Environmental Assessment and Preliminary Design Lakeview Boulevard Improvements Culvert Assessment.

PC3_ and PC4_ Pipeline Connectors

Regulating valves REG-SA and REG-SB

Technical Information Ball valves for high pressure applications

BUTTERFLY VALVES Series 800

Global Buckling Design for Flexible Flowlines

Culvert Design An Overview of the NYS Highway Design Manual Chapter 8

Buried Cable Installation Practices

Replacing the Reverse Osmosis ( RO ) Membranes

Chutes Part 2: Synthetic linings

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Designing and Benchmarking Mine Roads for Safe and Efficient Haulage. Roger Thompson Alex Visser

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Transcription:

EUROFLO CULVERT PIPE Fittings / Pipes F

EUROFLO FITTINGS RUBBERS SIZE CODE COMMENT 250 OD 315 OD 400 OD 500 OD 630 OD 800 OD 1000 OD 1200 OD 520-250-RBR 520-315-RBR 520-400-RBR 520-500-RBR 520-630-RBR 520-800-RBR 520-1000-RBR 520-1200-RBR SEALING ADAPTORS SIZE CODE COMMENT 160 ID 521-2430-160 200 ID 521-2430-200 HOLESAW SIZE CODE COMMENT 110 OD 521-2431-110 160 OD 521-2531-160 200 OD 521-2431-200 Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 2

SEALING RINGS SIZE CODE COMMENT 110 ID 521-2439-110 160 ID 521-2439-160 200 ID 521-2439-200 REDUCERS SIZE CODE COMMENT 315 x 250 521-315-250 400 x 250 521-400-250 400 x 315 521-400-315 BENDS AND JUNCTIONS SIZE CODE COMMENT 400 x 45 521-400-45 400 x 45 521-400-45J Junction 400 x 90 521-400-90 500 x 45 521-500-45 500 x 90 521-500-90 630 x 45 521-630-45 630 x 90 521-630-90 Note: Other fittings can be made to order Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 3

EUROFLO PIPE Farm Culvert 5.5 metre lengths Rubber ring joint if needed - see fittings page for codes for the rubber rings SN8 & SN16 stiffness available to order PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL SIZE (MM) OUTSIDE DIAMETER (MM) 520-250-5.5M 250 Farm Culvert Pipe Euroflo SN4 11 220 250 520-315-5.5M 315 Farm Culvert Pipe Euroflo SN4 6 285 315 520-400-5.5M 400 Farm Culvert Pipe Euroflo SN4 3 350 400 520-500-5.5M 500 Farm Culvert Pipe Euroflo SN4 2 450 500 520-630-5.5M 630 Farm Culvert Pipe Euroflo SN4 1 530 630 520-800-5.5m 800 Farm Culvert Pipe Euroflo SN4 1 700 800 520-1000-5.5M 1000 Farm Culvert Pipe Euroflo SN4 1 900 1000 520-1200-5.5M 1200 Farm Culvert Pipe Euroflo SN4 1 1100 1200 520-1550-5.5M 1550 Farm Culvert Pipe Euroflo SN2 1 1400 1550 520-1750-5.5M 1750 Farm Culvert Pipe Euroflo SN2 1 1600 1750 520-1950-5.5M 1950 Farm Culvert Pipe Euroflo SN2 1 1800 1950 520-2150-5.5M 2150 Farm Culvert Pipe Euroflo SN2 1 2000 2150 Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 4

Farm Culvert 5.5 metre lengths Inside diameter sizing PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL SIZE (MM) OUTSIDE DIAMETER (MM) 530-225-5.5M 225 Farm Culvert Pipe Euroflo SN4 11 220 250 530--5.5M Farm Culvert Pipe Euroflo SN4 6 360 Slotted Pipe 5.5 metre lengths PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL SIZE (MM) OUTSIDE DIAMETER (MM) 590-160-5.5M 160 Slotted Drainage Pipe 33 140 160 590-200-5.5M 200 Slotted Drainage Pipe 18 180 200 590-250-5.5M 250 Slotted Drainage Pipe 11 220 250 590-315-5.5M 315 Slotted Drainage Pipe 6 285 315 590-400-5.5M 400 Slotted Drainage Pipe 3 350 400 590-500-5.5M 500 Slotted Drainage Pipe 2 450 500 590-630-5.5M 630 Slotted Drainage Pipe 1 530 630 Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 5

NOTES: 6

NOTES: 7

EUROFLO CULVERT PIPE BENEFITS: > Easy to handle > Smooth bore = flow faster, less silt build-up > Maintenance-free life span > Rust free > Resists chemically aggressive soil conditions D+ D+ D+ INSTALLATION: EXCAVATION Dig a trench wider than the pipe. Ideal depth of cover is 600. TECHNICAL DATA: > Nominal stiffness SN4 (stocked). SN8 and SN16 available on indent > Socket one end > HDPE (polyethylene) > 5.5m long standard length > 6m long available > Sizes are outside diameter of pipe USES: > Farm culverts > Forestry culverts > Cut in 1/2 lengthways for stock troughs, fluming > Highway culverts > Mine culverts TIPS: > Project end of pipe to prevent erosion of backfill downstream > Timber, stone or grass headwalls to prevent erosion upstream > No sharp objects in contact with pipe when laying or backfilling > Socket end of pipe to face upstream ED GRANULATED ED BEDDING GRANULATED BEDDING ED GRANULATED BEDDING IMPORTANT: THOROUGHLY ALONG SIDES OF IMPORTANT: PIPE BY HAND RAMMING THOROUGHLY ALONG SIDES OF PIPE BY HAND RAMMING PIPE DIAMETER (D) PIPE DIAMETER (D) PIPE DIAMETER (D) 600 600 100 100 100 FINALLY FINALLY 600 500 500 PIPE LAYING Bedding to be 5-20 compacted granular material. Lay pipe in centre of trench. Selected compactible fill (not wet clay) added in layers around pipe to cover. Top up trench with compacted ordinary fill. ION OF BEDDING EUROFLO pipe uses its flexibility to transfer load to the surrounding bedding. Thorough compaction of the fill along the pipe sides is important to ensure long, trouble free service. Fill should be carefully compacted by hand raing along the sides of and around the pipe and built up to the finished ground surface. LIGHT DUTY INSTALLATION Selected excavation fill may be used as bedding. It should be substantially free from rock, tree roots or rubbish. Wet or saturated clay shouldn t be used as bedding or surrounding material. The minimum depth of cover should be 500. SUPPLIER: