Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Similar documents
Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

A9600 Anesthesia Workstation. Your healthcare, we care.

D The plus that gives you more DRÄGER FABIUS PLUS

State-of-the-art anesthesia technology

Emergency Transport and Ventilation

Safe Accurate Reliable. CWM-301 Anesthesia System

Aespire 7100 Essential performance Compact design

Anesthesia Workstation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

D The specialist for every environment DRÄGER FABIUS TIRO

Hospital and Transport for Controlled Breathing

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

D The plus that makes all the difference DRÄGER FABIUS PLUS

Dräger Fabius plus XL Anaesthesia Workstations

Draeger Fabius GS Pre-Use Check

The centerpiece of a comprehensive anaesthesia workstation

Flow meter. bellow vaporizer. APL valve. Scavenging system

Oxylog VE300 Emergency & Transport Ventilation

Dräger Savina Sub-Acute Care Ventilation

Dräger Fabius GS premium Anaesthesia Workstations

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

Dräger Fabius Tiro Anaesthesia Workstations

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Hallowell EMC Anesthesia WorkStation Operating Manual

Technical Data and Specifications

Your patients, our primary focus. Siesta i Whispa anesthesia machine

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Anes Machine Use and Pre-use Check - CA1 focus

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Dameca MRI 508. State-of-the-art MRI technology

SLE5000 Neonatal Ventilator with High Frequency Oscillation

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations


NEONATAL/INFANT VENTILATOR

APUS Anesthesia Machines

Blease900 Ventilator PATIENT CENTERED VENTILATION

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Focused on essentials DRÄGER SAVINA 300

Focused on essentials DRÄGER SAVINA 300

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Oxylog 3000 plus Emergency & Transport Ventilation

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

Airox Supportair Ventilator

Resuscitaire Neonatal Open Care

Recommendations on Checking Anaesthesia Delivery Systems

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

DATA SHEET. VENTILATION SERVO-s

ALLIED HEALTHCARE PRODUCTS, INC. Litholyme, GE Medisorb, Carbolime, and Amsorb Plus. Test Summary

An intuitive and innovative answer to your anaesthesia challenges

D Beyond essentials DRÄGER SAVINA 300 SELECT

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

Innovating with you Shaping exceptional care

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Anesthesia Machine Intro

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

D Designed for non-invasive ventilation DRÄGER CARINA


S/5 Aespire. Quick Reference Guide

IEC C LASSIFICATIONS:

Panther 5 Acute Care Ventilator

Your patients, our primary focus

Primus Anaesthesia Workstations

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

The anaesthesia workstation focused on you

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

Oxylog 2000 plus Emergency & Transport Ventilation

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Carestation 620. Key Features. Ventilation. Design

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Introducing Astral. Greater freedom. Confident care. Designed efficiency

SLE5000 Infant Ventilator with HFO

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Carestation 650. Key Features. Design. Ventilation

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

GE Healthcare. Aestiva/5. More than superior ventilation

AUTOVENT 4000 VENTILATOR

Milestones of Aeonmed Ventilators

HAMILTON-MR1. Technical specifications HAMILTON-MR1

Carestation 650c. Key Features. Design. Ventilation

D Beyond essentials DRÄGER SAVINA 300 SELECT

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Anesthesia. Midmark Animal Health Products

Penlon MRI Product Range ANAESTHESIA SOLUTIONS

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Supporting your patients every breath

GE Healthcare. Avance Carestation. Upgrade promotions guide

SERVO-s v8.0 Data sheet

Operation and Maintenance of the EPV200 Portable Ventilator

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

Transcription:

Narkomed MRI-2 A perfect fit for the MRI environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care

The complete anesthesia solution for the MRI environment A Perfect Fit for the MRI Environment The Narkomed MRI-2 is the only anesthesia system with an integrated ventilator and VPO monitor, designed and engineered to perform, without distance or electromagnetic restrictions, in shielded or unshielded MRI environments of up to 3.0 Tesla. This feature allows operation with the shortest possible distance between the patient and the machine; a very important consideration when scanning pediatric and neonatal patients. The powerful magnetic fields that create detailed patient images, can create substantial problems with standard anesthesia equipment. Even when placed in direct contact with the MRI, the Narkomed MRI-2 works dependably and produces no detectable image distortion. The machine combines an integrated electronic ventilator and an integrated exhaled volume, airway pressure and oxygen monitor in one compact unit.

MT-32-2001

Familiar Narkomed Features Integrated Monitor Airway pressure, volume and oxygen data are displayed along with an airway pressure waveform. Automatic integrated alarms warn if parameter limits are exceeded. These adjustable alarms allow individual settings to satisfy a wide range of clinical operations. The monitor is similar in display and operation to the Narkomed GS, which is sold throughout the world. Patient Suction The familiar Narkomed Patient Suction system with a regulator and reusable canister specifically designed for MRI use is a standard feature on the Narkomed MRI-2. Battery Backup A three-hour battery backup guarantees continuous operation of all machine functions, including monitoring and alarm functions, in the event of a power failure. AV2+ Ventilator The AV2+ ventilator is a volume-preset, time-cycled, pressure-limited anesthesia ventilator. It is equipped with electronic timing, pneumatic circuitry and independent controls for breathing rate, inspiratory to expiratory ratio, tidal volume, inspiratory flow and inspiratory pressure limit for flexible ventilation. The unit is capable of inverse I:E ratios with a built-in safety mechanism and can be used in a wide range of patient conditions. Venturi technology is incorporated to ensure economical usage of drive gas. Flow Sensor The new ultrasonic flow sensor has no moving parts, is easy to clean, and is extremely accurate and reliable. Absorber Assembly The dual canister absorber provides for extended operation between absorbent changes. It incorporates an Auto/Manual selector that permits easy ventilation mode selection.

Optional Features Vapor 2000 The Vapor 2000 vaporizer compensates for variances in pressure, temperature and flow and needs no annual recalibration. Filling is accomplished with either a pin index system or conventional funnel filling. Scavenger System Waste gas scavenging is accomplished with either an open or closed scavenging system. In the open system neither positive nor negative pressure can build up since the patient breathing system relief ports are open to the atmosphere. The closed system uses spring-loaded valves for positive and negative pressure relief. Additional Power Solutions Kits are available to solve power needs in MRI and non-mri environments. Use of an optional power supply kit gives you the versatility to use the machine in MRI environments with different field strengths. A complete anesthesia machine, the MRI- 2 can be used in non-mri environments as well.

Specifications General Dimensions (W x H x D) Weight Weight of Battery Charger Electricity 31.5 x 53 x 27 (80 x 135.3 x 68.6 cm) 230 lbs (104.3 kg) 3 lbs (1.36 kg) 120 Volt Power Supply 100-120 VAC @ 50/60 Hz 220/240 Volt Power Supply 200-240 VAC @ 50/50 Hz Battery Reserve Power Time Charging Time Gas Delivery System Number of Gases 3 hours 16 hours Oxygen Flush Flow Rate 55 L/min Low Oxygen Supply Pressure Alarm 34-40 psi Vaporizer Vapor 2000 Positions 2 Mounting 3 gas capability (O 2, N 2 O, Air) Fixed Ventilator AV 2+ Frequency I:E Ratio 4:1-1: 4.5 Inspiratory Flow Tidal Volume Pressure Limit Adjustment Oxygen Monitoring 1-99 (in 1 BPM increments) 10-100 L/min 20-1500 ml 15-120 cmh 2 O Display Range 10-100 % Resolution 1 vol% O 2 Airway Pressure Monitoring Display Range Resolution Tidal Volume Monitoring Display Range Resolution 10 to 125 cmh 2 O 1 cmh 2 O.01-2.0 L 0.01 ml Utility Requirements System operates with 120 VAC @ 50/60 Hz electrical source. Regulator assemblies and yokes for external O 2 and N 2 O cylinders. O 2, N 2 O and Air hoses for connecting pipeline sources to DISS machine connections. Tests with MRI Scanners of up to 3.0 Tesla (shielded or unshielded) Testing done with unit touching the MRI. North America: Draeger Medical, Inc. 3135 Quarry Road Telford, PA 18969 USA Tel: +1-215-721-5400 Toll-free: +1-800-437-2437 Fax: +1-215-723-5935 E-mail: wwwinfo@draegermed.com www.draeger-medical.com 90 49 320 / 04.05-3 / gm-ls-dw / Printed in Germany / Chlorine-free - environmentally compatible / Subject to modifications / 2005 Dräger Medical AG & Co. KGaA