U. S. NAVAL SUBMARINE MEDICAL CENTER NAVAL SUBMARINE BASE NEW LONDON GROTON, CONNECTICUT MEMORANDUM REPORT NO

Similar documents
THE EFFECT OF INTERMITTENT EXPOSURE TO 3% C0 2 ON ACID-BASE BALANCE AND ELECTROLYTE EXCRETION

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

Day-to-day management of Tracheostomies & Laryngectomies

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

SPECIAL REPORT No FOR ALTITUDE CHAMBER OPERATIONS. Approved By. Captain Ashton Graybiel, MC, USN Director of Research.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Summary Report for Individual Task Perform Oral Suctioning Status: Approved

Submarine Base, Groton, Conn.

Medical Instruments in the Developing World

SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 855

Breathing Process: Inhalation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Endotracheal Suctioning: In Line ETT

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Operation and Maintenance of the EPV200 Portable Ventilator

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

McHENRY WESTERN LAKE COUNTY EMS SYSTEM FALL 2014 CONTINUING EDUCATION MANDATORY FOR ALL PRIMARY AND PROBATIONARY ALS SYSTEM PROVIDERS.

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

MEDAP-MOBILE GAS SUPPLY

Flow meter. bellow vaporizer. APL valve. Scavenging system

Anaesthetic infrastructure and supplies

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

NIOSH Task Number 18388

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Air Eliminators and Combination Air Eliminators Strainers

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

CAPITAL CONTROLS SERIES NXT3000

EDCO VACUUM UNIVERSITY SECTION 18 VACUUM UNIVERSITY EDCO USA. 18:1

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

WIKA INSTRUMENT CORPORATION

with O 2 Controller Instruction Manual

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

UNDERWATER HEARING IN MAN: II. A Comparison of Temporary Threshold Shifts Induced by 3500 Hertz Tones in Air and Underwater

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Marschalk Model # 94000

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

The Principles of Vacuum And Clinical Application in the Hospital Environment

War Surgery Dr. Abdulwahid INTRODUCTION: AIRWAY, BREATHING

Understanding Tracheostomy Care

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Breathing Devices. Chapter 8 KNOWLEDGE OBJECTIVES SKILL OBJECTIVES. 6. List four precautions to take when using oxygen.

Submarine Base, Groton, Conn. REPORT NUMBER 668

Checking a Breathing System

OPESAVER Super Irrigation System

u. %N&tMz2&foi&INE MEQpa*,G» ER Submarine Base, Groton, Conn. REPORT NUMBER 566 EFFECT ON VISION OF REPEATED EXPOSURE TO CARBON DIOXIDE

The right atmosphere for health. A system for medical gas supply

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Lesson 6: Flow Control Valves

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Float Valve Function and Design Considerations

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Characterizers for control loops

TEST BENCH FOR SAFETY VALVES

NAVY ENTIONEIAL TEHIALVii. INFORMATION SERVICE SPrnqf.ied Va App~vourcr Pu..ic ro1."so; distributlon uraimit"4 6

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Respiratory Physiology Gaseous Exchange

NG Tube and Trach Skills Trainer LF01174U Instruction Manual

PART SEVEN THE HISTORY AND APPLICATION OF HIGH FREQUENCY OSCILLATORY VENTILATION (HFOV)

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Inert Air (N2) Systems Manual

(12) United States Patent (10) Patent No.: US 6,524,267 B1

RESPIRATORY HEALTH PRODUCTS

PAPR Flow Tester. instructions. part no WARNING

MACS Mask CPAP System

AT Kelly Torso. Directions for Use

Lung Volumes and Capacities

7625 West New York Street Indianapolis IN Phone: Fax: Order Desk:

Chlorinator MODEL MK-I

IT is frequently desirable to be able to determine the

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Third measurement MEASUREMENT OF PRESSURE

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

The SAV04 Small Animal Ventilator. Contents Page

COVER PHOTO: JONAS DAHM / DEEP SEA PRODUCTIONS VERSATILE REBREATHERS HANDCRAFTED IN DENMARK

AUTOVENT 4000 VENTILATOR

300 Held Drive Northampton Pa

Series Environmental Chambers

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Budget Range Operators Handbook

Perfect Medical Product

Digester Processes. 1. Raw Sludge Pumping System

AT Kelly Torso. Directions for Use

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Powers Controls RC 195 Single Input Receiver-Controller

Unity Sleeveless Elevated Vacuum System

Mechanical Ventilation

Waste Oil Extraction Unit

SECTION 11 VACUUM GRIPPER

Electric Blower Based Portable Emergency Ventilator

Basic & Controlled Atmosphere Glove Boxes

Transcription:

U. S. NAVAL SUBMARINE MEDICAL CENTER NAVAL SUBMARINE BASE NEW LONDON GROTON, CONNECTICUT 06340 MEMORANDUM REPORT NO. 68-10 PORTABLE CLINICAL SUCTION DEVICE FOR USE IN HYPERBARIC CHAMBERS MF011.99-9003 23 May 1968 Investigator: Joel J, Nobel Lieutenant, MC, U. S. Naval Reserve Transmitted by: Reviewed and Approved by: \^/^U^9^^'i 0 LCDR T. N. Markham, MC, USN Head, Military Operations Branch Charles F. Gell, MD, DSc(Med) Scientific Director Approved and Released by: Gerald Kr. Duffner Captain, MC, U.S. Navy Commanding Officer

SUMMARY PAGE THE PROBLEM To develop a simple, effective and reliable suction apparatus which will not present a fire hazard in hyperbaric chambers. FINDINGS A light-weight, readily portable instrument was developed which meets all the requirements for operation in hyperbaric chambers. APPLICATIONS The simplicity and effectiveness of this instrument have made it not only useful for hyperbaric chambers but also for other routine clinical applications of suction. ADMINISTRATIVE INFORMATION This investigation was conducted as a part of Bureau of Medicine and Surgery Work Unit MFOH.99-9003 Physiological Effects of Long Duration Habitation in Hyperbaric Air and Artificial Environments. The present report was approved for publication on 23 May 1968 and has been designated Submarine Medical Center, Submarine Medical Research Laboratory Memorandum Report No. 68-10. This is Report No. 4 on the Work Unit listed above: This document has been approved for public release and sale; its distribution is unlimited; PUBLISHED BY THE NAVAL SUBMARINE MEDICAL CENTER ii

\ ABSTRACT A new portable clinical suction device has been developed which operates on compressed gas. Its performance equals that of typical electric rotary aspirators and far exceeds the performance of conventional Venturi devices or foot-powered pumps. It can achieve 27 in./hg. vacuum, has no moving parts, requires little maintenance and incorporates a suction tip, off-on trigger, vacuum control and vacuum release in an easily handled pistol grip. iii

\ \ Figure 1. V^culette Suction Unit.

PORTABLE CLINICAL SUCTION DEVICE FOR USE IN HYPERBARIC CHAMBERS INTRODUCTION Aspiration of the naso-oropharynx and trachea to remove secretions, debris and vomitus is often essential to ensure adequate pulmonary ventilation. Under relatively controlled conditions in an intensive care unit or with a tracheostomy present, aspiration can usually be performed without difficulty. When the need for aspiration arises under conditions of emergency care and resuscitation, suction becomes a difficult task for a variety of reasons. The need for rapidity, the natural tendency for human error in emergencies, unsatisfactory patient position, lack of assistance and the mechanical inadequacy of portable suction devices all contribute to the problem. Proper equipment design incorporating good mechanical and technical characteristics can be supplemented by good human engineering to enhance rapidity of use and decrease the probability of error and the need for assistance. Rosen and Hillar have characterized the ideal clinical suction apparatus. A minimum vacuum of 25 in./hg., free air flow of 25-30 I/min and rapid drawdown time to maximum vacuum to decrease the time required for adequate suctioning are all desirable. 1 Currently available equipment fails, for the most part, to attain these goals. There are four basic types of portable aspirators in use today. The suction bulb, while inexpensive and reliable, creates insufficient vacuum and will not remove viscid secretions or adequate volume. Electric-powered, rotary aspirators provide adequate suction but require large heavy battery power packs or frequently overload already burdened ambulance electrical systems. The commonly used AMBU foot powered unit is very awkward for a single operator to use and provides Only 11 in./hg. suction. Gas-powered Venturi aspirators of the type so frequently incorporated in resuscitation apparatus for use in the hospital, ambulances, aid stations and the field are wasteful of oxygen and do not provide adequate suction. One commonly used portable unit can only attain 4 in./hg. Such devices have been notoriously ineffective in removing any significant amount of viscid material or vomitus from the airway. A new device has been developed to meet the heed for a lightweight, portable suction apparatus.* It is capable of exceeding 25 in./hg. vacuum, contains rto moving parts, is modest in its consumption of compressed gas or oxygen and has proved reliable and easy to use. It has been designed specifically for portable resuscitation kits, litters, ambulances, and emergency life support and resuscitation carts. It also has general use within the hospital, emergency room and intensive care unit and may be used in hazardous locations where electric motors might be dangerous, e.g., hyperbaric chambers or coronary care units. It is especially useful on litters when it is desirable to have suction immediately available for post-operative patients in transit between operating room, recovery room, intensive care unit and ward. The need for aspiration frequently arises at inopportune times made worse by the vagaries of hospital elevators. DESCRIPTION In a typical configuration for use on resuscitation carts or within the hospital, a block containing the air ejector and vacuum gauge is attached to a heavy aluminum chassis which also holds the collection bottle, hose and pistol grip (Fig. 1). The basic apparatus is a one-stage air ejector powered by compressed gas with an input pressure which may vary from 40 to 75 psig. Maximum performance is attained with pressures approximating 50 psig. This pressure value is provided by the vast majority of hospital wall oxygen systems and most resuseitator regulators. * Corbin-Farnsworth Inc., Palo Alto, Calif. 1

Figure 2. Pistol Grip of the Suction Unit which Contains the Off-On and Suction Control. Figure 3. Deep Suction Catheter Attached to the Pistol Grip Control. 2 I

The air ejector is attached to a 500 cc collection bottle which is equipped with an overflow valve to prevent suctioned material from passing into the air ejector. Should debris inadvertently enter the ejector, the mechanism tends to be self-purging and, in addition, is easily cleaned. The suction tubing leads from the collection bottle to the pistol grip. The off-on control and suction control are incorporated into an instinctively held pistol grip (Fig. 2). Squeezing the trigger supplies oxygen or other compressed gas from the primary source to the air ejector. The amount of vacuum created, from 0 to 27 inches/hg. depends on the pressure exerted on the trigger by the operator. A tapered nozzle, representing the barrel of the pistol, may be used as the oropharyngeal suction tip or will receive a standard catheter for deep suction. Releasing the trigger immediately causes the vacuum to drop to zero in the same manner as removing one's thumb from the T or Y connector between tubing and catheter of a conventional aspirator. Intermittent suction or release of caught tissue is thus easily controlled. The pistol grip provides single hand control of the off-on trigger, degree of vacuum desired and manipulation of the suction nozzle or catheter. This permits the other hand to be used for positioning the patient or fine manipulation of a deep suction catheter (Fig. 3). The combination of the trigger off-on control in the same hand as the suction tip or catheter, together with the very rapid increase in vacuum, permits insertion of the suction tip or catheter with the apparatus shut off. Squeezing the trigger builds up vacuum very rapidly during the manipulation or removal withdrawal phase«oxygen is thus consumed only during the actual period of auctioning and not during the period of handling the catheter or inserting it. This results in a great reduction of gas consumption. This is important in ambulances and portable resuscitation kits which carry limited supplies of bottled oxygen. Quick connect-disconnect fittings permit rapid removal and assembly of the clear Polyvinylchloride oxygen tubing. The clear Polyvinylchloride aspiration tubing itself snaps into the pistol grip and may be easily cleaned or discarded and replaced. Various mountings and chassis may adapt the unit to its various applications. Attachment to a wall oxygen outlet or oxygen tank, placement on a shelf or bedside table, use in specialized life support systems or portable resuscitation kits are all within the device's capabilities. RESULTS The performance characteristics of a production unit of the new portable aspirator were determined using a mercury manometer, calibrated American Gas Meter Company Model 802 totalizing flowmeter and a stop-watch. Values represent the average of ten trials. Comparative performance of other aspirators were made with the same instrumentation and conditions (Table I). All aspirators were new as supplied by the manufacturers. This new self-contained portable suction device exceeds the degree of vacuum attained by available foot pumps and Venturies and approximates that attained by electric rotary types. Free air flow rate and ability to suction a viscid test medium is superior. Using the factory provided collection jars, time required to attain an adequate clinical level of vacuum is less in the device described than in the electric rotary type (Fig. 4). DISCUSSION While air ejectors have been used for suction devices for many years, 2 they have never been able to attain the vacuum forces of electric rotary pumps. Within the past few years, increased understanding of fluid dynamics has elevated the state of the art in design of such devices. It is now possible to build devices which exceed the specifications of electric aspirators. In addition to increased portability, freedom from power lines or vehicular electrical systems, air ejectors have no moving parts, are virtually maintenance free and require no lubrication. There is no inherent electrical hazard with danger of inadvertent ground paths. ~3

TABLE I COMPARISON OF NEW GAS POWERED ASPIRATOR WITH CONVQfTIONAL ELECTRIC ROTARY, FOOT POWERED AND GAS POWERED ASPIRATORS ASPIRATION TIME FOR FREE AIR FLOW THROUGH 100 ml. UNIFORM MAXIMUM VACUUM NO. 16 FR. RUBBER PHISOHEX TEST CATHETER MEDIUM THROUGH NO. 16 FR. RUBBER CATHETER VACULETTE 27 ln./hg. 17 l./min. 46 Seconds SORENSON 28 in./hg. 14.3 l./min. 64 Seconds l/10th h.p. Electric Rotary Aspirator AMBU 11 ln./hg. 10.6 l./min. Unsatisfactory Foot powered äspirato r EMERSON 7.6 ln./hg. 8.0 l./min. Unsatisfactory Venturi on Resuscitator STEPHENSON 6.2 ln./hg. 11.0 l./mln. Unsatisfactory 25r RATE OF ATTAINMENT OF VACUUM VACULETTE with 560cc factory Collection Jar SORENSON Factory Collection Jar SORENSON Collection Jar Adjusted to 560ml 6 SECONDS 10 12 Figure 4. Rate of Attainment of Vacuum. 4

In addition, this device may possess a significant physiologic advantage over electric or gas powered suction devices which are turned on prior to insertion of the catheter. All deep suction results in negative pressure in the lungs. The degree of negative pressure created and the probability of resultant atelectasis or decreased intrathoracic pressure resulting in increased systemic venous return and dilation of the vena cava and right heart are dependent on the suction created, the size of the catheter with respect to the tracheal diameter and related factors. 3 Radiographic demonstrations of this phenomena during suction have been made 4 and reductions in arterial oxygen saturation during suction are also well established. 5 It is clearly advantageous that suction not exist until the intended moment of actual aspiration and during withdrawal of the catheter. Some suction exists at the catheter tip even though the T or Y junction of an electric or gas powered suction apparatus may be open to the atmosphere. 6 The operator might possibly avoid activating the suction machine until the catheter is in position. However, many off-on switches cannot easily be reached by the person manipulating the catheter, and it is often difficult to completely compress and block many rubber or plastic catheters while positioning them. The combination of a trigger switch to energize the suction apparatus and modulate vacuum together with the short time to achieve maximum vacuum may minimize undesirable intrapulmonary and intrathoracic negative pressures and their potential consequences in this new suction unit. was therefore undertaken to determine its suitability for chamber use. This portable clinical suction device has been recently developed and operates from compressed gas. Its performance equals that of typical electrical rotary aspirators and far exceeds the performance of conventional Venturi devices or foot powered pumps. It can achieve 27 in./hg. vacuum, has no moving parts, requires little maintenance and incorporates a suction tip, off-on trigger, vacuum control and vacuum release in an easily handled pistol grip. As long as the device is supplied with an input pressure of 50 psig over ambient pressure, it will function well. REFERENCES 1. Rosen, M., and Hillard, E.K.: The use of suction in clinical medicine, Brit. J. of Anaesth. 32: 486, 1960. 2. Lake, N.C.: The use of suction in surgery, Lancet, 2:1166, 1924. 3. Rosen, M., and Hillard, E.K.: op cit. 4. Rigler, L.G.: Functional roentgen diagnosis: anatomical image-physiological interpretation, Amer. J. Roentgenol. 82:1, 1959. 5. Kergin, F.J., Bean, D.M., and Paul, W.: Anoxia during intrathoracic operations, J. Thorac. Surg. 17:709, 1948. 6. Saher, N.F., and Salt, R.: A portable suction apparatus not dependent on a source of electricity, Brit. Med. J. 1:790, 1943. 7. Saklad, M., and Paliotta, J.: Trans-endotracheal tube suction in the simulated breathing patient, Anesthesiology, 28:4, 1967. SUMMARY The simplest clinical suction device for use in hyperbaric chambers is a value and tubing to utilize the pressure differential between the inside of the chamber and the atmosphere. This presents certain dangers, however, since the suction can far exceed that which is desirable, with resultant damage to tissue. Electric rotary aspirators present a potential fire hazard. Evaluation of a new commercially available, gas-powered aspirator 5

UNCLASSIFIED Security Classification DOCUMENT CONTROL DATA -R&D (Security classification of title, body of abstract and indexing annotation must be entered when the overall report is classified) 1. ORIGINATING ACTIVITY (Corporate author) U.S.Naval Submarine Medical Center, Submarine Medical Research Laboratory 2«. REPORT SECURITY CLASSIFICATION UNCLASSIFIED 2b. GROUP N/A 3. REPORT TITLE PORTABLE CLINICAL SUCTION DEVICE FOR USE IN HYPERBARIC CHAMBERS 4. DESCRIPTIVE NOTES (Type of report and inclusive dates) Interim report 5- AUTHOR<s> (First name, middle initial, last name) JoelJ. NOBEL, LT MC, USNR «REPORT DATE 23 May 1968 6«. CONTRACT OR GRANT NO. b. PROJECT NO. MF011.99-9003.04 7«, TOTAL NO. OF PAGES 5 9a. ORIGINATOR'S REPORT NUMBER(S) 76. NO. OF REFS 7 Memorandum Report No. 68-10 9b. OTHER REPORT NO(S) (Any other number» that may be assigned this report) 10. DISTRIBUTION STATEMENT This document has been approved for public release and sale; its distribution is unlimited 11. SUPPLEMENTARY NOTES 12. SPONSORING MILITARY ACTIVITY ÜiS.Naval Submarine Medical Center Box 60Ö, Naval Submarine Base Grotön, Connecticut 06340 13. ABSTRACT A new portatie clinical suction device has been developed, which operates from com- pressed gas. Its performance was evaluated and found to equal that of typical electric rotary aspirators and to far exceed the performance of conventional Venturi devices or foot-powered pumps. It can achieve 27 in./hg. vacuum, has no moving parts, requires little maintenance and incorporates a suction tip^ off-on trigger, vacuum control and vacuum release in an easily handled pistol grip. DD^.,1473 t NOV es S/N 0101-807.6801 (PÄGE,) UNCLASSIFIED Security Classification 3ND PPSO 13152

UNCLASSIFIED Security Classification KEY WORDS LINK A ROUE [ WT Suction device, portable, clinical (compressed gas powered) Suction device for use in hyperbaric chambers Non-electrical, clinical suction apparatus DD, F? 1473 «BACK, (PAGE 2) UNCLASSIFIED Security Classification