Analysis of dilatometer test in calibration chamber

Similar documents
Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand

THE EFFECT OF EMBEDMENT DEPTH ON BEARING CAPACITY OF STRIP FOOTING IN COHESIVE FRICTIONAL MEDIUM

DEVELOPMENT OF A ROBUST PUSH-IN PRESSUREMETER

Pressuremeters in Geotechnical Design

Level 3 Cambridge Technical in Engineering 05822/05823/05824/05825/05873 Unit 3: Principles of mechanical engineering

STRESS ANALYSIS OF BELL CRANK LEVER

Cubzac-les-Ponts Experimental Embankments on Soft Clay

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Example 4 - Airbag. Summary

UNIT-I SOIL EXPLORATION

Bearing Capacity and Settlement Response of PMS Tanks on Cohesionless Soil Lithology in Lekki, Lagos of Nigeria

Analyses of the fuel cell stack assembly pressure

Abstract. 1 Introduction

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading

Critical face pressure and backfill pressure in shield TBM tunneling on soft ground

Lateral Load Analysis Considering Soil-Structure Interaction. ANDREW DAUMUELLER, PE, Ph.D.

Stress and deformation of offshore piles under structural and wave loading

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

Engineering Practice on Ice Propeller Strength Assessment Based on IACS Polar Ice Rule URI3

Application of pushover analysis in estimating seismic demands for large-span spatial structure

The Seventh International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7) Shanghai, China; September 2-6, 2012 Wind tunnel measurements

THE STABILITY OF THE PIPELINE LAID ON A PORO-ELASTIC SEABED

Calibration and Validation of the Shell Fatigue Model Using AC10 and AC14 Dense Graded Hot Mix Asphalt Fatigue Laboratory Data

Part 11: Flat dilatometer test

computed using Equation 3-18 by setting the 2nd term equal to 0 and K A equal to K o and using the pressure distribution as shown in Figure 3-23.

Deformation parameters of soils determined by the cone penetration test

Theory of a vertically loaded Suction Pile in CLAY

Offshore platforms survivability to underwater explosions: part I

The 9th International Symposium on Automation and Robotic in Construction June 3-5,1992 Tokyo, Japan

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Modeling of thin strip profile during cold rolling on roll crossing and shifting mill

using Strength Ratios

Bending Vibration Analysis of Pipes and Shafts Arranged in Fluid Filled Tubular Spaces Using FEM

Vibrations of table tennis racket composite wood blades: modeling and experiments

ENTUCKY RANSPORTATION C ENTER. College of Engineering

BURIED PIPE RESPONSE SUBJECTED TO TRAFFIC LOAD EXPERIMENTAL AND NUMERICAL INVESTIGATIONS

Title Tsunami during 2011 East Japan Eart. The final publication is available より本文ファイルは に公開.

APPLICATION OF PUSHOVER ANALYSIS ON EARTHQUAKE RESPONSE PREDICATION OF COMPLEX LARGE-SPAN STEEL STRUCTURES

Learn more at

Design and Analysis of an Unfired Pressure Vessel for Conducting Pressure Test

Structural Design and Analysis of the New Mobile Refuge Chamber

Data Acquisition System and Computer

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS

Analysis of Shear Lag in Steel Angle Connectors

EXPERIMENTAL INVESTIGATION ON OPTIMUM INSTALLATION DEPTH OF PVD UNDER VACUUM CONSOLIDATION ABSTRACT

Design and Optimization of Weld Neck Flange for Pressure Vessel

CONE PENETRATION TESTS

Pore-Air Entrapment during Infiltration

Friction properties of the face of a hand-held tennis racket

Chapter 4: Single Vertical Arch

DESIGN OPTIMIZATION OF WORK ROLL CHOCK AND BACKUP ROLL CHOCK IN COLD ROLLING MILL

Rudder Investigation. By Harish M

The tensile capacity of suction caissons in sand under rapid loading

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

ANALYSIS OF THE POSITIVE FORCES EXHIBITING ON THE MOORING LINE OF COMPOSITE-TYPE SEA CAGE

Developing FE-Tire Model Library for Durability and Crash Simulations

Abstract. 1 Introduction

Presented to the International Technical Rescue Symposium, November Abstract

Wind Flow Validation Summary

Tension Cracks. Topics Covered. Tension crack boundaries Tension crack depth Query slice data Thrust line Sensitivity analysis.

Design and Analysis of Rotary Lawn Mower

An Innovative Solution for Water Bottling Using PET

For a cantilever pile wall shown in Figure 1, assess the performance of the system and answer the following questions.

CENGRS GEOTECHNICA PVT. LTD. Job No Sheet No. 1

Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA , United States.

Irrigation &Hydraulics Department lb / ft to kg/lit.

Wind tunnel tests of a non-typical stadium roof

DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS

ESTIMATION OF LATERAL SPREAD OF A CAISSON TYPE QUAY CAUSED BY BACK FILL LIQUEFACTION

Desaturating sand deposit by air injection for reducing liquefaction potential

Pressure coefficient on flat roofs of rectangular buildings

Investigation of Stresses in Ring Stiffened Circular Cylinder

Influence of Settlement on Bearing Capacity Analysis of Shallow Foundations on Sandy Clays in the Niger Delta, Nigeria

6995(Print), ISSN (Online) Volume 4, Issue 1, January- April (2013), IAEME TECHNOLOGY (IJDMT)

Plastic non-symmetric bifurcation buckling of circular cylinders under uniform external hydrostatic pressure

STUDY ON UPWARD MOVEMENT OF FINES FROM SANDY SEABED UNDER CYCLIC WATER PRESSURE CHANGE DUE TO WAVES

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

STUDY OF UNDERWATER THRUSTER (UT) FRONT COVER OF MSI300 AUTONOMOUS UNDERWATER VEHICLE (AUV) USING FINITE ELEMENT ANALYSIS (FEA)

V-H-M Yield Surface describing Soil Structure Interaction of Sub-sea Structures and Wind Turbines on Caisson Foundations in Soft Clays

382. Fellenius, B.H. and Terceros, M.H., Information on the single pile, static loading tests at B.E.S.T. Proceedings of the 3rd Bolivian

Appendix E BACKGROUND TO STRAIN GAUGE AND EXTENSOMETER CALIBRATIONS. R. Frederking and D. Sudom

SHEAR PERFORMANCE OF RC FOOTING BEAMS BY CAP-TIE SYSTEM USING WELDED STIRRUPS

Bottom End-Closure Design Optimization of DOT-39 Non-Refillable Refrigerant Cylinders

Soil-Structure Interaction Analysis for Bridge Caisson Foundation

World Journal of Engineering Research and Technology WJERT

ISOLATION OF NON-HYDROSTATIC REGIONS WITHIN A BASIN

Autodesk Moldflow Communicator Process settings

Effects of Changes of Spokes in the Operation of a Rimmed Flywheel

Golf Ball Impact: Material Characterization and Transient Simulation

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

Saturated-Unsaturated Consolidation

Residual Stresses in Railway Axles

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Fatigue Analysis of English-Willow Cricket Bat

A STUDY ON LIQUEFIED GROUND DISRUPTION EFFECTS ON LIQUID STORAGE TANK BEHAVIOR

Typical factors of safety for bearing capacity calculation in different situations

Design and Structural Analysis of Cylindrical Shell

Computer aided sand wedge shape assessment by using particle simulation

Stress evaluation of a bicycle crank arm connection using BEM

Transcription:

Analysis of dilatometer test in calibration chamber Lech Bałachowski Gdańsk University of Technology, Poland Keywords: calibration chamber, DMT, quartz sand, FEM ABSTRACT: Because DMT in calibration test chamber is two parameter test performed in well defined boundary conditions with a homogeneous soil mass, it presents an interesting possibility for numerical simulations. Insertion of the blade followed by membrane inflation was modeled. Dilatometer tests performed in calibration chamber at Gdańsk UT were modeled with finite element methods using Mohr-Coulomb and Hardening Soil Models. Soil data from triaxial tests were used to define model parameters. The tests made in loose and dense sand at different stress levels were modeled. The influence of BC1 and BC conditions and size effect in the calibration chamber was studied numerically. A and B values measured in dilatometer tests were compared to the calculated mean contact normal stress acting on the dilatometer membrane after the blade insertion and after the inflation of the membrane, respectively. Two modes for membrane inflation were applied: uniform horizontal stress and volumetric strain imposed. A more realistic shape of the membrane displacement and a better correlation with calibration chamber data were obtained with volumetric strain imposed. A good correlation was found between A and B values measured in calibration chamber and the calculated mean normal contact stress on the membrane. 1 DMT TESTS IN CALIBRATION CHAMBER A series of dilatometer tests in the calibration chamber were performed for confining pressures ranging from 50 to 400 kpa with either loose or dense sands. The soil specimen was 5 cm in diameter and 100 cm high. The detailed description of the calibration chamber is given in Bałachowski and Dembicki (2000). Soil mass in the calibration chamber is prepared with sand raining. Dense soil mass (I D =0,8) is obtained with stationary device. Soil mass with I D =0,4 is formed using small traveling sieves and small falling height of grains. The sand mass is consolidated with K 0 conditions. Predominantly quartz uniform (U=1,4) fine sand (d 50 =0,21 mm) from the Baltic beach in Lubiatowo is used. The sand parameters were obtained from triaxial CID tests for loose, medium dense and dense sand specimens. Maximum angle of internal friction max (Fig. 1), modulus of deformation E 50 at the half of deviatoric stress at failure (Fig. 2) and dilatancy angle were determined. These parameters at given consolidation stress (here 50 kpa) are used (Table 1) to model the soil behavior using Mohr-Coulomb (M-C) and Hardening Soil Model (HSM). A boundary condition with constant lateral stress (BC1) was maintained during blade insertion. At the end of each 5 cm step of penetration the membrane was inflated and A and B measurements were read. An example of readings taken at a vertical stress of 100 kpa applied to the upper membrane in the calibration chamber is given for loose and dense sand (Fig. ). Quite uniform distribution of readings with depth is observed. Derived A/B ratio, up to 10, is typical for clean quartz sand. Figure 1. Angle of internal friction.

a) b) q q E,,h l f= 2 5 4 ql (1-2 ) Eh E,h l f= 0.7 16 Eh ql 4 Figure 4. Schemes for membrane deflection: a) simple beam in plane strain conditions, b) circular plate Figure 2. Modulus of deformation E 50. Table 1. Soil parameters from triaxial tests. I D [-] E 50 [MPa] 0,4 5 5 40 0,8 42 15 70 Figure. Profiles of A, B measurements in calibration chamber with v = 100 kpa. 2 NUMERICAL ANALYSIS 2.1 Plain strain vs. axisymetric problem The penetration of dilatometer and the inflation of the membrane are very complex, truly three dimensional phenomena. The penetration of the dilatometer blade, being almost flat, can be considered in simplified manner as 2D problem. The inflation of the circular membrane is, however, a truly D phenomena. Two schemes for membrane inflation analysis in elastic conditions can be considered (Fig. 4). In a first one corresponding to plane strain conditions - membrane can be treated as a simple beam with free supports. In the second scheme circular plate with free supports on the circumference is considered. The formula for membrane deflection under uniform load for both schemes (Fig. 4) are given for : - simple beam with v=0, as : 4 ql f 0,1422 (1) Eh - circular plate as : 4 ql f 0,047 (2) Eh For the same load, the membrane deflection will be thus about,5 times more important in plane strain conditions than in axisymetric ones. In order to model properly the inflation of circular membrane one should increase,5 times the imposed deflection of the membrane center for the calculation under plane strain conditions. The problem is however more complex as the soil is elasto-plastic and we should include not only the imposed pressure, but the soil response as well. Some numerical analyses were done to verify the membrane response in plane strain and axisymetric conditions. The calculations were performed using PLAXIS v.8.2 code and Mohr-Coulomb (M-C) and Hardening Soil Model (HSM). A fine mesh, additionally refined near the blade and the membrane, with 15 nodes elements was used. The blade was placed horizontally on the surface of the box filled with sand. Due to symmetry only a half of the membrane was modeled. Vertical stress of 40 kpa was applied on the box surface to simulate lateral stress in the calibration chamber v = 100 kpa. Then the membrane was inflated by imposing volumetric strain in the cluster just behind the membrane. A numerical response corresponding to B reading was evaluated for plane strain (beam) and axisymetric conditions (circular plate). The computed contact normal stress distribution on the half of the membrane is given in Figure 5. Considerably higher contact normal stress is obtained for axisymetric conditions than for plane strain ones. Normal stress distribution is also given for the 1,1 mm displacement multiplied by,5 in plane strain conditions. Due to soil plasticity the contact normal stress in axisymetric case is higher than in plane strain conditions with,85 mm deflection at the membrane center.

Figure 5. Calculated contact normal stress distribution on the dilatometer membrane. 2.2 Modeling of blade insertion As a first approximation the real chamber dimensions were assumed for calculation mesh. The DMT blade was placed in the middle of the chamber. Stage calculations were made. Gravity was applied in addition to the boundary stresses and conditions. The blade shape was reproduced with the membrane 6 cm in diameter. An interface was introduced between the membrane and the soil. The penetration of the blade was stopped in the calculation when penetration resistance approaches asymptotic value. At this moment the normal stress distribution in the membrane interface was registered, which corresponds to A measurement. A series of preliminary calculations show that a considerable chamber size effect was observed during insertion phase (Fig. 6). Horizontal displacement fields after the blade insertion for the chamber of 5 cm and 200 cm in diameter are presented. For further analysis a chamber 200 cm in diameter was assumed. 2. Modeling of blade inflation The membrane inflation was modeled in two manners (Fig. 7). According to the first one a cluster behind the membrane was inactivated and the lateral uniform stress was applied behind the membrane until its center was displaced 1,1 mm, corresponding to B measurement. Larger displacements at the edges of the membrane, related to the stress concentration, are observed than in the center (Fig. 8). Such a form of the membrane deflection is however unrealistic, so a different solicitation mode was considered. Moreover, as the membrane inflates the applied stress remains horizontal. The membrane inflation was modeled with volumetric strain imposed in the cluster behind the membrane. The stress exerted on the membrane is not horizontal, but it is perpendicular to the membrane, which simulates the gas pressure. The maximum deflection of the membrane is observed in its center (Fig. 8). This mode of solicitation was chosen for further analysis. a) b) P membrane membrane imposed volumetric strain Figure 7. Two modes for membrane inflation. Figure 6. Horizontal displacement fields after the blade insertion for different diameter of the chamber. Figure 8. Shape of the inflated membrane with imposed horizontal stress and volumetric strain.

A considerable influence of chamber size effect can be found (Fig. 9) for the B measurement (inflated membrane). Chamber size effect in numerical analysis of normal stress distribution along the membrane corresponding to A and B measurements is given for dense sand (Fig. 10) and for loose sand (Fig. 11). Chamber radius of 100 cm minimizes the influence of the chamber size effect in the calculation. A calibration chamber 200 cm in diameter was used for further parametric studies. Figure 11. Normal contact stress on the membrane - chamber size effect for loose sand. Figure 9. Horizontal displacement fields with inflated membrane. An influence of the soil modulus of deformation E 50 on the calculated normal stress for A and B measurements was studied (Fig. 12). Calculations were performed for the angle of internal friction equal to 42. The calculated normal contact stress distribution on the membrane for A and B measurements is insensitive to soil modulus of deformation E 50 higher than 70 MPa. The contribution of the angle of internal friction was studied (Fig. 1) for dense sand with E 50 =70 MPa. Contact normal stress to the membrane corresponding to A and B measurements is sensitive to the internal friction angle, especially for its high values. The distribution of contact normal stress on the membrane for loose and dense sand is presented (Fig. 14) for the calculations performed with the soil parameters derived from triaxial tests. Mean contact normal stress on the membrane for loose and dense sand calculated with assumed soil parameters (Table 1) is given for dense sand (Table 2) and loose sand (Table ). The evaluated mean contact stresses corresponding to both A and B measurements are close to the values measured in DMT test in calibration chamber (Table 2, Table ). Figure 10. Normal contact stress on the membrane - chamber size effect for dense sand. Figure 12. Normal contact stress on the membrane - influence of deformation modulus.

Table 2. Calculated mean normal contact stress to the membrane for dense sand. M-C HSM E 50 [MPa] [ ] A B A B 40 42 65 679 78 662 8 42 558 70 40 44 608 42* 85 81 76 721 100 42 101 858 * A=92 kpa, B=670 kpa for DMT in calibration chamber Figure 1. Normal contact stress on the membrane influence of angle of international friction. Table. Calculated mean normal contact stress to the membrane for loose sand. M-C E 50 [MPa] [ ] A B 0 5 41 402 5# 45 427 40 8 50 518 70 5 4 475 # A=62 kpa, B=520 kpa for DMT in calibration chamber Figure 14. Normal contact stress on the membrane for loose and dense sand for A and B measurements. 2.4 Influence of boundary conditions The comparison of the calculated distribution of normal contact stress at BC1 and BC boundary conditions is given for dense (Fig. 16) and loose sand (Fig. 17). Higher normal stress is calculated for no lateral strain condition (BC) than at constant lateral stress (BC1) condition. The contribution of the boundary condition is more evident for dense sand. Comparative analyses with M-C and HSM Soil Models were performed for dense sand using the same values of internal friction angle and modulus of deformation E 50. For A measurements the numerical analysis gives a similar response for both soil models. For membrane deflection analysis, HSM gives smaller normal contact stress than M-C (Fig. 15). Figure 16. Normal contact stress on the membrane for BC1 and BC conditions for A and B measurements. Figure 15. Normal contact stress on the membrane calculated for M-C and HSM soil models.

ACKNOWLEDGEMENTS I express my gratitude to prof. Silvano Marchetti for his suggestions and for supplying DMT equipment used in the calibration chamber tests. REFERENCES Figure 17. Normal contact stress to the membrane for BC1 and BC conditions for A and B measurements. CONCLUSIONS DMT model test with well defined boundary conditions in a reference sand was studied with FEM. Simplified two dimensional analysis in plane strain conditions were used to model D problem of blade insertion and membrane inflation. Larger deflection of the dilatometer membrane was applied in numerical analysis in order to adjust and approximate axisymetric response of circular membrane. A quite good approximation of DMT model tests was obtained in numerical modeling of two pressures (A, B), independently. The parametric studies were performed and the analysis shows that the calculation performed with the soil parameters derived from triaxial tests fits well the measurements in calibration chamber. The results are sensitive to the internal friction angle and less to the modulus of deformation. Sensitivity analysis shows that the chamber with at least 200 cm in diameter is necessary to minimize chamber size effect in numerical calculation. In reality the blade insertion induces less soil disturbance than in 2D case. Inflation of circular membrane generates less soil deformation than in plane strain conditions. It is generally considered that classical chamber 120 cm in diameter permits to avoid size effect in dilatometric tests. With the calibration chamber 5 cm in diameter some size effects could be however observed, especially for dense specimen. Additional analysis are necessary to model the blade insertion with large deformation analysis. Analysis with PLAXIS code, even with updated mesh procedure, does not permit to reach large displacement during dilatometric blade insertion. Further research with D analysis is necessary. Baldi, G. Bellotti, R. Ghionna, V. Jamiolkowski, M. Marchetti, S. & Pasqualini, E. 1986. Flat dilatometer tests in calibration chambers. Proc. In Situ 86, GT Div., ASCE, June 2-25, Blacksburg, VA : 41-446. Bałachowski, L. & Dembicki, E. 200. La construction d une chambre d étalonnage à l Université Technique de Gdańsk. Studia Geotechnica et Mechanica, Vol. XXV, No. 1-2. Jamiolkowski, M. Lo Presti, D. C. F., Manassero, M. 2001. Evaluation of relative density and shear strength of sand from CPT and DMT. LADD Symposium, October 2001. Marchetti, S. 1980. In situ tests by flat dilatometer, Journal of the Geotechnical Engineering Division, ASCE, Vol. 106, No. GT. Marchetti, S. Monaco, P. Totani, G. & Calabrese, M. 2001. The flat dilatometer test (DMT) in soil investigations. A report by the ISSMGE Committee TC16. Proc. IN SITU 2001, Bali, May 21. PLAXIS v.8.2 manual