HIGH FLOW HIGH PRESSURE PUMP type BMS

Similar documents
HIGH-PRESSURE HIGH-FLOW PUMP UNITS TYPE BMS

Max. working pressure 3650 bar / 52,200 psi Max. flow up to 50 liters / minute Fully made of stainless steel I N N OVATO R S T H E O U R

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Pneumatic service kit Model CPG-KITP

HAnd-operated HIGH Pressure valves type NV-series

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand test pump Models CPP700-H and CPP1000-H

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Air Operated Hydraulic Pumping Systems to 50,000 psi

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

InnovDos Foam proportioning system

InnoVfoam B.V. InnovDos Foam Proportioning System

Phuel Modular Control Units

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Mechanical Pressure Measurement

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Plant, components and devices for very high and high pressures (7000 bar and over)

Pressure calibration equipment

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

ELRO IP/ XP Peristaltic Pumps

SITRANS P measuring instruments for pressure

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Pneumatic dead-weight tester Model CPB3500

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

GROUTEC SCOTT VICKERS. Grouting Equipment

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Calibrators. Series PC..., PM...

Variable Area Flow Meters

Phuel Portable Control Units

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

QUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Additel 780 Series Pressure Controller

Precision Pressure Regulators

Additel 761 Automated Pressure Calibrators Selection Guide

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Additel 780 Series Pressure Controller

Pneumatic valve islands

Direct Operated Precision Regulator Modular Style. Standard Specifications

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

Pilot Operated Check Valves Catalog Quick Reference

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Liquid level regulating valves Types PMFL / PMFH and SV

DI-DRO ADVANCED FORMING SYSTEMS

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Pressure Equalising Valves Model , for Differential Pressure Gauges

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Instrumentation Catalogue

CAST IRON SAFETY VALVE TYPE 6301

Series IRV1000/2000/3000

Hydraulic pressure balance Model CPB5800

Air Preparation. Regulators, Pressure Regulators, Lubricators and Accessories. Keeping the World Flowing

ADT 761 Automated Pressure Calibrator

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

HP/UHP Spring-Loaded Regulator

Volume Booster. Volume Booster Description Supply pressure Pressure range Connection Device Page max. bar bar thread

kysimply Unique Single Seat

RK-IR Sample Draw Aspirator Adapter Operator s Manual

HumiSys HF High Flow RH Generator

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Hydraulic Accumulators with Back-Up Nitrogen Bottles

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

Operating Procedure TITON SUBSEA BOLT TENSIONER

Air Amplifiers & SYSTEMS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

OWNER S TECHNICAL MANUAL

Differential pressure

CSA Sample Draw Aspirator Adapter Operator s Manual

Additel 761 Automated Pressure Calibrators

DIAPHRAGM PUMP MODEL PDM 1-175

6301 TYPE CAST IRON SAFETY VALVES

Glass tube flowmeters Series 2000

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Transcription:

When you have to test objects on different locations within your workshop, the mobile pump system BMS gives you the possibility to test adequately on different sites. Through its wheels (or forklift pockets) the BMS can in comparison to a workshop unit more easily be moved. Which gives you the opportunity to be flexible in the layout of your workshop. Furthermore, the pump system is an ideal pump to adapt to your specific requirements for testing large volumes at high pressure. The BMS is often equipped with two air driven pumps. Hence, if you want to speed up your operation process by testing objects more quickly a high flow low pressure air driven pump can be added to the high flow high pressure pump that is standard part of the BMS. ORDERING CODE See ordering system in document +31 (0) 50 501 6877 hpsales@resato.com www.resato.com KEY FEATURES Mobile pressure unit Robust design Suitable for pressurizing with oil, water or an emulsion of both Modular design with numerous options KEY SPECIFICATIONS Max. flow up to 50 L/min Max. pressure 3650 bar/52,200 psi Stainless steel construction All parts are made out of non-corrosive materials

UNIT DESCRIPTION PUMP Unlike most other air driven pumps, there are no mechanical pilot valves and long internal pilot channels which have a negative influence on the reliability and cycling speed of the pump. The air drive section of the pump only has the air piston and cycling spool as moving parts. Freezing of the pump is prevented by using an air cycling valve provided with a lightweight spool for high air flow at low air velocity. The high pressure seal can be replaced within minutes, without dismantling the air drive section. Check valve seats can also be replaced within minutes and costly downtime is reduced to a minimum. The pump may be driven by either compressed air or nitrogen at a maximum pressure of 7 bar (100 psi). For output pressures and flow capacities, see the type table. When even higher output capacities are required, the unit can be equipped with Resato pumps of type P200. MATERIALS All critical components e.g. bleed valve, tubing, gauges, fittings and wetted pump parts are made from stainless steel or bronze. The frame of the unit is also made from stainless steel. TEST GAUGE The test gauge has class 1.0% F.S., and a housing of ø 100 mm (4 inch), and is made fully out of stainless steel. The gauge is filled with glycerine and fitted with laminated safety glass. For ranges, see type table. AIR PRESSURE GAUGE The air pressure gauge has a range of 0-10 bar/0-140 psi, class 1.6% F.S., and a housing of ø 63 mm (2.5 inch). The air pressure gauge is made out of fully stainless steel, filled with glycerin and fitted with laminated safety glass. CERTIFICATES The BMS is supplied with a test certificate for the complete unit, a calibration report for the test gauge and optional recorder, and an operating and maintenance manual.

OPTIONS RECORDER The mechanical recorder is clockwork-driven, has class 1.0% F.S. and a chart diameter of ø 223 mm, and is fully made out of stainless steel. Its range is in accordance with the installed test gauge. The chart can be used as a test certificate. For chart revolutions, see type table. PC DATA ACQUISITION AND RECORDING SYSTEM The documentation of test results is very important. Therefore Resato offers a PC data acquisition and recording system (type CR). This system generates a test certificate with a graph immediately after completion of a test. ATEX As an option, Resato air driven pumps can be delivered in a version that comply with ATEX 94/9/ EC. The user of the unit is responsible for classifying the area of use, while identifying the equipment category is the responsibility of the manufacturer. The Resato units are ATEX approved for Group II, category 2 zones G & D. MORE OPTIONS See the type table for more options. TECHNICAL SPECIFICATIONS GENERAL Dimensions Maximum operating pressure Maximum flow 1100x550x850 mm (lxwxh, lid closed) 1100x550x1375 mm (lxwxh, lid open) 3.650 bar/52,200 psi 50 L/min WEIGHT BMS-W models (single acting) BMS-D models (single acting) Extra weight Double acting pump 2nd single acting pump 2nd double acting pump 70 kg 85 kg +4 kg +9 kg +25 kg +29 kg

TYPE ORDERING SYSTEM Unit type Reservoir BMS D 20 (1 Single acting pump) 2 Double acting pump Order example: BMS-D-20-2 (Order example in case of a low and high flow pump: BMS-D-20-2/255-1) TYPE TABLE Reservoir High flow low pressure pump (option) L/min High pressure low flow pump L/min Max. outlet pressure bar/psi Gauge ranges 1 2 1 2 bar psi 20 13.2 25.0 20 13.2 25.0 140/2100 0-160 0-2,500 30 9.5 18.0 30 9.5 18.0 200/2850 0-250 0-4,000 40 6.4 12.2 40 6.4 12.2 285/4100 0-400 0-5,000 D = 40 l Reservoir W = No reservoir 65 4.2 8.0 115 2.4 4.5 180 1.5 2.9 65 4.2 8.0 115 2.4 4.5 180 1.5 2.9 450/6400 800/11,400 1245/17,800 0-600 0-1000 0-1600 0-8,000 0-15,000 0-20,000 255 1.1 2.1 255 1.1 2.1 1790/25,600 0-2000 0-30,000 400 0.7 1.3 400 0.7 1.3 2800/40,000 0-3000 0-45,000 520 0.5 0.9 520 0.5 0.9 3655/52,200 0-4000 0-55,000

OPTION ORDERING SYSTEM RPS TYPE: Float cock Components Atex BMS-W-20-2 /R0 /D /I /EX Order example: BMS-W-20-2/R0/D/I/EX OPTION TABLE rev/hr(s) R0 = 1/4-1 hr R1 = 1 hr R4 = 4 hrs R8 = 8 hrs R24 = 24 hrs Gauge scale B = bar P = psi D = double scale (standard) Components I = Isolate valve F = Float cock in reservoir (BMS-D only) M = 4 wheels instead of 4 legs L = Lid to protect the instruments H = Lifting pads FO = Forklift pockets CP = Closed panels Atex EX ACCESSORIES HIGH PRESSURE OUTLET CONNECTIONS Pump High flow low pressure pump/ High pressure low flow pump 20 30 40 65 115 180 255 400 520 HP outlet connection F F Explanation of outlet connection types A = 1/2 NPT female B = 1/2 BSP female C = 1/2 BSP male hose connection E = 1/4 BSP male hose connection F = M30x2 H.P. female connection 1e Energieweg 13 9301 LK Roden - Holland Resato international BV P.O. Box 30 hpsales@resato.com 9300 AA Roden - Holland www.resato.com/highpressure +31 (0) 50 501 6877 +31 (0) 50 501 2402 V0.1 - Please note that general data and specifications given in this brochure are subject to change without notice. Feel free to contact our sales department if you need more definite information.