DSL, DSH: Specially designed pressure limiter

Similar documents
DSB, DSF: Pressure monitors and pressure switches

DSB, DSF: Pressure monitors and pressure switches

Pneumatic pressure switch 20DD

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

RLP100F901, F915, F924: Pneumatic room-pressure controller

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pressure switch Type BCP

RLP100F910, F916, F918: Dual-channel volume flow controller

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Technical Data. Dimensions

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Pressure Measurement Single-range transmitters for general applications

Model range*1) Switching pressure difference

Hydraulic (Subsea) Shuttle Valves

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Pressure switch and Thermostat CAS

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Pressure switch, Differential pressure switch and Thermostat RT-E

Bespoke Hydraulic Manifold Assembly

[Instruments for vacuum measurement, checking and adjustment] 3

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Technical Data. General specifications. Rated operating distance s n 5 mm

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Technical Data. Dimensions

Special Documentation Proline Promass 80, 83

Technical Data. Dimensions

Pressure Switches Application Guideline

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Safety Manual VEGASWING 61, 63. NAMUR With SIL qualification. Document ID: 52084

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Safety Manual VEGAVIB series 60

Gas density monitor With integrated transmitter Model GDM-100-TI

Types and approvals. Page 1/6. Data Sheet

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure Measurement Single-range transmitters for general applications

What safety level can be reached when combining a contactor with a circuitbreaker for fail-safe switching?

Safety Manual VEGAVIB series 60

New Thinking in Control Reliability

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Proportional pressure regulators VPPE

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Safety manual for Fisher GX Control Valve and Actuator

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Pressure switch KP-E. Data sheet

Pressure controls for hydro carbons, zone II applications, Type KPE

Differential pressure switch MP 54, MP 55 and MP 55A

Safety Manual OPTISWITCH series relay (DPDT)

Vibrating Switches SITRANS LVL 200S, LVL 200E. Safety Manual. NAMUR With SIL qualification

Pressure transmitter PASCAL Ci4

Pressure control, differental pressure control and thermostat Type RT

Pressure switch and Thermostat Type KPS

4/2 way Pneumatic Solenoid Valve

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

SPCH/ Blowing block

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Compact pressure switches for gas and air

Safety. Operating instructions Pressure switches for gas DG..H, DG..N Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Precision pressure sensor Basic version Model CPT6020

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Differential Pressure Control Types MP 54, MP 55 and MP 55A

B2KL: 6-way ball valve with male thread, PN 16

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Pressure transmitters EMP 2

Technical Data. General specifications. Rated operating distance s n 2 mm

Inverse Proportional Pressure-Relief Cart., Size 2 4

SPR - Pneumatic Spool Valve

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Rosemount 2130 Level Switch

Pressure Transmitters 36 F-27839

Prewired position switches FA series

C-Flow Coriolis Mass Flow Meters

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Pressure switches and thermostats, type KPS

Pressure Switch for gas and air

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

AMS 2710 PCB pressure sensor module with V output

JUMO dtrans p30 Pressure Transmitter

Mass Flow Controller (MFC) for Gases

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Pressure switch with bourdon tube

Technical Data. Dimensions

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Pressure switch and Thermostat KPS

Expansion Thermometers Stainless Steel Series, Model 70

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Self-operated Pressure Regulators for special applications

Transcription:

Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching point can be adjusted Sealable Pressure sensor made of brass for non-aggressive media (DSL) Pressure sensor made of stainless steel for aggressive media (DSH) Locking type: With falling pressure (DSL) or with rising pressure (DSH) SIL 2 certified as per EN 61508 Approved for marine applications (GL and LR certified) Xsd P Technical data Xs Power supply Maximum load with gold-plated contacts1) 400 ma, 24 V, 10 VA Minimum load with gold-plated contacts 4 ma, 5 V Maximum load with silver-plated con- 10(4) A, 250 V~, 50 W, 250 V= tacts 3 2 B03377 1 DSL1**F001 Minimum load with silver-plated con- 100 ma, 24 V tacts G½" male Admissible ambient temperature -20...70 C Xsd Xs Pressure connection P Parameters Ambient conditions 1 B01574 3 2 Construction Housing Transparent cover Housing material Impact-proof thermoplastic Device plug Standard plug with female connector for cable of Ø 6...10 mm Type of protection2) IP65 (EN 60529) DSH1**F001 Standards and directives CE conformity according to SIL-conformity as per SIL 2 1) 2) 3) Protection class I (IEC 60730) Test marks3) TÜV DSL: SDBF ID: 0000006022 DSH: SDB ID: 0000006023 PED: 2014/68/EU, cat. IV Ship-approved Germanischer Lloyd (GL) Lloyds Register EMC Directive 2014/30/EU EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 Low-Voltage Directive 2014/35/EU EN 60730-1, EN 60730-2-6 PED 2014/68/EU VdTÜV pressure information sheet 100, cat. IV EN 12952-11 EN 12953-9 Machinery Directive 2006/42/EC (according to Appendix II, 1 B) EN ISO 12100 Standards IEC 61508 parts 1-2 and 4-7 IEC 61511 parts 1-3 If the contacts are subjected to a load greater than specified, the gold plating will be destroyed. They are then classed merely as silver contacts and lose the properties of gold-plated contacts Depending on the fitting position, see the fitting instructions. The devices are not suitable for outdoor applications. Certificates can be downloaded from www.certipedia.com Right of amendment reserved 2017 Fr. Sauter AG 1/6

Overview of types / Min. change for reset: Average values Type Setting range Min. change for reset Maximum pressure Admissible sensor temperature Admissible vacuum loading Weight DSL140F001 0...2.5 bar 0.4 bar 12 bar 70 C -0.7 bar 0.5 kg DSL143F001 0...6 bar 0.5 bar 16 bar 70 C -0.7 bar 0.5 kg DSL152F001 6...16 bar 1.2 bar 30 bar 70 C -1.0 bar 0.4 kg DSH127F001-1...5 bar -0.4 bar 16 bar 110 C -1.0 bar 0.5 kg DSH143F001 0.5...6 bar -0.45 bar 16 bar 110 C -0.7 bar 0.5 kg DSH146F001 1...10 bar -0.8 bar 18 bar 110 C -1.0 bar 0.5 kg DSH152F001 2...16 bar -1.5 bar 60 bar 110 C -1.0 bar 0.3 kg DSH158F001 5...25 bar -1.8 bar 60 bar 110 C -1.0 bar 0.3 kg DSH170F001 15...40 bar -2.0 bar 60 bar 110 C -1.0 bar 0.3 kg A A DSL: Locks when the pressure falls (SDBF); pressure sensor made of brass for non-aggressive media DSH: Locks when the pressure rises (SDB); pressure sensor made of stainless steel Accessories Type Description 0192222000 Cap nut with solder connector 0259239000 Reduction nipple G½" on 7/16" 20-UNF-2A for copper tubes of Ø 6 mm, brass 0292001000 Setpoint adjuster according to customer's wishes (setting accuracy: ±3% of the setting range, but a minimum of ±0.2 bar) 0292004000 Setpoint adjuster sealed (with accessory 0292001 only) 0292150001 Fixing bracket for wall mounting 0296936000 Fixing brackets for rail: top-hat rail EN 60715, 35 7.5 mm and 35 15 mm 0311572000 Screw fitting for copper tubes of Ø 6 mm, brass 0381141001 Profile sealing ring, copper, for G½" A 0296936000: With accessory 0292150001 only Description of operation For regulating and monitoring pressure in liquids, gases and vapours, according to VdTÜV pressure information sheet 100. Especially suitable for applications in compact installations, for pipe mounting or wall mounting. Minimum pressure limiter DSL: When the pressure falls below the lower change-over point (adjustable setpoint X S ), the pressure limiter locks mechanically and switches the contacts from 1-3 to 1-2. When the pressure exceeds the lower change-over point by the amount of the min. pressure increase X sd, the contacts can be reset from 1-2 to 1-3 by levering out the reset button using a screwdriver. Maximum pressure limiter DSH: When the pressure exceeds the upper change-over point (adjustable setpoint X S ), the pressure limiter locks mechanically and switches the contacts from 1-2 to 1-3. When the pressure falls below the upper change-over point by the amount of the min. pressure decrease X sd, the contacts can be reset from 1-3 to 1-2 by levering out the reset button using a screwdriver. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product regulations must also be adhered to. Changing or converting the product is not admissible. Electrical serviceable life Mechanical serviceable life of the pressure pads according to pressure 100 > 2 10 6 switch strokes Typically 2/6 Right of amendment reserved 2017 Fr. Sauter AG

cos φ = 1 cos φ = 0.6 cos φ = 0.3 4) 10 A, 250,000 switchings 5 A, 400,000 switchings 2 A, approx. 10 6 switchings 3 A, 400,000 switchings 3 A, 250,000 switchings 2 A, 400,000 switchings 1 A, 700,000 switchings ) Important: Using the device in SIL applications and as a safety device in machine construction changes its electrical serviceable life. Typically to be considered: 10 A, 6,000 switchings Technical appendix B03772 RC circuitry for inductive load For the optimum RC circuitry, see the information from manufacturers of gates, relays, etc. If this is not available, the inductive load can be reduced by applying the following rule of thumb: Capacity of the RC circuitry (µf) equal to or greater than the operating current (A) Resistance of the RC circuitry (Ω) approx. the same as the resistance of the coil (Ω) Materials Materials that come into contact with the medium: Pressure sensor made of brass (DSL): brass, stainless steel, nitrile rubber. Pressure sensor made of stainless steel (DSH): stainless steel, material no. 1.4104 5) and 1.4541 Admissible fluids for pressure switches with a safety function: Fluid group I, danger potential categories IV or V as per article 13 of Pressure Equipment Directive 2014/68/EU. Fluid group II Notes: Additionally, the extents of applicability of the TÜV certifications and the standards they contain must be considered. The user must check the compatibility of the fluids used with the materials of the pressure sensor. Engineering and fitting notes The pressure limiters conform to the European Directive on pressure equipment 2014/68/EU and belong to device category IV as safety components. The devices also conform to Low-Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. The devices are suitable for use in installations based on TRD 604, sheet 1 and sheet 2. 4) cos φ < 0.3: significant reduction in serviceable life. With RC circuitry, serviceable life as with cos φ > 0.3 (also see technical appendix) 5) TÜV individual certification Right of amendment reserved 2017 Fr. Sauter AG 3/6

11.1 Product data sheet 23.770 Use in safety applications The devices fulfil the requirements of standard EN 61508 and can be used in safety applications up to SIL 2. The information in the related operating instructions and in the safety manual must be considered. The products are SIL2-compatible as per EN/IEC 61508 and EN/IEC 61511 and are therefore suitable for use in safety-oriented systems. SIL-compatibility figures Type A Type of sub-system Operating mode Probability of failure on demand Low demand rate PFDspec 3.12 E-05 Assumed demand rate fnp 1/a Test interval Ti 1a Non-dangerous failure rate SFF > 63.3% Hardware error tolerance HFT 0 Diagnostic degree DC 0 Confidence level 1-α 95% Diagnostic degree of cover for repeat check PTC > 72.2% fnp 1/a 1.14 E-04 /h Total error rate λs + λd 9.71 E-09 / h 10 FIT Lambda dangerous detected λdd 0.00 E+00 / h 0 FIT Values for 1001 architecture at low demand rate Assumed demand frequency Lambda dangerous undetected λdu 3.56 E-09 / h 4 FIT Lambda safe detected λsd 0.00 E+00 / h 0 FIT Lambda safe undetected λsu 6.14 E-09 / h 6 FIT Average time between two errors MTTF 1.03 E+08 h 11,761 a Average time between two dangerous errors MTTFD 2.81 E+08 h 32,046 a Average probability of a failure when demand arises PFDavg 1.56 E-05 ) When the minimum required hardware error tolerance of HFT=1 is considered, the pressure switches are compatible up to SIL 3 when operated redundantly. β factor: Proportion of failures that can have the same cause. Architecture β 1002 10% 1003 5% 1004 3% 2003 15% 2004 6% Architectural and structural requirements must be tested by the end user. Duration of use and repeat checks: Approving a duration of use of over 5 years (+1.5 years in storage) is solely the responsibility of the operating company when considering the specific usage conditions and the prescribed test cycles. The operating mode as per IEC/EN 61508-4, article 3.5.12, has been defined as operating mode with low demand rate. To check that the pressure switches are functioning correctly, repeat checks must be performed in the installations. These checks should be performed a maximum of 10 times per year. But at least once a year. Applications as a safety device in machine construction Based on standard ISO 13849-1 and for use in systems with a high demand rate, the following parameters were determined. Maximum admissible demand rate: 50 per year B10d = 6000 PFH = 9.51 E-08 4/6 Right of amendment reserved 2017 Fr. Sauter AG

A single pressure monitor or limiter can be used within the operating range of standards EN ISO 13849-1 to PL c. To safeguard against higher risks (PL d, PL e), they must be used redundantly, and in the downstream safety module, the plausibility of the switching states must be monitored continuously. Architectural and structural requirements must be tested by the end user. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Additional information Technical information Fitting instructions DSB1.., DSF1.., DSH1..., DSL1.. P100014216 Declaration on materials and the environment MD 23.770 Safety manual D100237459 Connection diagram Dimension drawing 1 2 3 P A01503b 46 Reset (DSH/ DSL) 44 73 67 18 10 296936 35 a 20 54 20 292150/001 4,5 7 296936 70 82 S 2 G1/2A Typ a b s DSA 140, 143, 146 134 40 36 DSB 138, 140, 143 DSL(F) 140, 143,146 DSF 125,127, 135, 138 DSH 127, 143, 146 DSB 146, 152, 158, 170 148 30 27 DSL 152 DSF,DSH 152, 158, 170 113 25 22 29 41 b M07815c Right of amendment reserved 2017 Fr. Sauter AG 5/6

Accessories G1/2 42,5 s27 Ø 12 M00317a G1/2 38 s27 7/16" 20-UNF-2A M00315 292150 Ø4,2 4,5 25 5 4,5 9 15 9 7 35 54 2 18 13 30 32 40 70 33 4,5 12 13 0,5 M08427 18 M00166 s22 8 25,5 381141 14,8 8 Ø6 G1/2 Ø26 M00777 4,2 M06962 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 Right of amendment reserved 2017 Fr. Sauter AG