ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Similar documents
R E D I C O N T R O L S

GAS COMPRESSION SYSTEM

Reverse Osmosis System Installation Guide and Operation Manual.

LOCKOUT/TAGOUT: Operating Procedure TABLE OF CONTENTS

COURSE MAPPING RATINGS FORMING PART OF ENGINEERING WATCH

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Lockout Tagout Policy

OPERATING INSTRUCTIONS

FAULT CODE TROUBLESHOOTING INDEX

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

LOCKOUT/TAGOUT PROGRAM

CLEARWATER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL

i) Thirty-six months of seagoing service in the engine department; or

NTF-515. Operation Manual

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

OPERATION MANUAL NTF-60 Plus

Time-Delay Electropneumatic Applications

GAS DEHYDRATION SYSTEM

Portable Oil Lube Air Compressors

NTF-230 OPERATION MANUAL

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Sequence of Operations

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

OPERATION MANUAL NTF-15

THERMAL EVAPORATION UNIT (for Al evaporation)

LENNOX SLP98UHV DIAGNOSTIC CODES

Refrigerant Recovery System Model 3600 Part No

Part IV: Troubleshooting

accidents which arise due to non-observance of these instructions and the safety information herein.

TEST BENCH FOR SAFETY VALVES

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

Start up XXX from normal shutdown Introduction

Model 3600-R410A. Part No Instruction Operation & Maintenance

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

KJ4000 Operating Instructions & Parts Manual NSN

BUBBLER CONTROL SYSTEM

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

R-410A 50% R-32 50% R-125.

MOL LNG Transport (Europe) Ltd File: 02 Checklists 6 pages Rev. No. 1 Loading Plan Part Two (2) (Line UP) Loading Plan Part Two (2) (Line Up)

47' MLB Basic Engineering Casualty Control Exercises

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

Lockout/Tagout - Control of Hazardous Energy Program

GAS DEHYDRATION SYSTEM

KKT Training Series: ECO Series, Preventative Maintenance

Operating Procedures for Metal Evaporator I

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Record of Assessment OFFICER IN CHARGE OF AN ENGINEERING WATCH

Facilities Management

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual

Introduction to Pneumatics

Aquavar SOLO 2 Frequently Asked Questions

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

GM Series Dual-Block Multi-Function Gas Control Valves

REDI CONTROLS, INC. Model RS-503/13-C3. RECOVERY SYSTEM for Very High Pressure Refrigerants R-13, R-23, R-503, & SUVA-95

MICRO BASED CONTROL SYSTEM YLCS-SA/HA/AA YAES-SA 2 System YAES-SA 3 System YAES-DSA 4 System

Inert Air (N2) Systems Manual

FX134, FX1234, FX3030 Problem and Solutions

Exercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control

Elements of a Lockout/Tagout Program OSHA

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

Steam Locomotive Operating Procedures SVLS Locomotive 1973 Steam Up

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Summary Report for Individual Task 551-8ST-1027 Operate Emergency Steering Status: Approved

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

MPC-3000 INSTALLATION MANUAL

Workhorse-15 Oxygen Generator

SAMPLE WRITTEN PROGRAM for Control of Hazardous Energy LOCKOUT TAGOUT

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

BLS 1900 Optimum REVERSE OSMOSIS SYSTEM

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Document How to Set Single Stage Press Pressures

High Performance Oilless Commercial Refrigerant Recovery System. User Manual REV E 06/30/03

Operating Instructions

University of Arkansas Office of Environmental Health and Safety

Lockout/Tagout Program

Refrigeration Scroll For Parallel Applications

ACV-10 Automatic Control Valve

Installation Instructions

Operation and Maintenance Manual

Stand-Alone Bubble Detection System

Record of Assessment OFFICER IN CHARGE OF AN ENGINEERING WATCH

1020 Industrial Drive, Orlinda, TN fax

WESTERN CONNECTICUT STATE UNIVERSITY LOCKOUT/TAGOUT PROCEDURE S-107

RecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual

Remotely-installed Hydraulic Module

Sedan Range. Evaporative Loss System Check Clarified Procedure

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

Lockout/Tagout Program Occupation Safety & Health Standards for General Industry 29 CFR

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Transcription:

110 AIR CONDITIONING CHILLED WATER PLANT 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure chilled water expansion tank level is at its proper level 3. Ensure chilled water system valving is set correctly (i.e.: pump inlet / outlet valves, and chilled water by-pass valve, etc are open) 4. Start appropriate chilled water pump; pump discharge pressure to be maintained at approximately 70 PSI 5. System is now up and running 1. Secure Chilled Water Pump by pressing the Motor Controller OFF pushbutton 2. Close the Chilled Water Pump inlet and outlet valves NOTE: If Chilled Water Pump MCC disconnect switch is opened install the proper Lockout / Tagout devise and make the appropriate entry in the Lockout / Tagout Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 1 of 17

110 TON AIR CONDITIONING PLANT 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure condenser cooling water system is operating 3. Ensure chilled water system is operating, additionally check that all conditioned space thermostats are set properly 4. Check compressor crankcase oil level via sump sight glass; oil level should be between 1/8 to 1/4 of sight glass 5. Verify all system refrigerant valves are lined up as per TABLE 2-1, which is found in the OEM Technical Manual. Only exception being the compressor suction service valve (SSV) 6. Open compressor SSV one full turn 7. Start compressor at Compressor Motor Control (MCC), by momentarily pressing the START button. Immediately continue to open the compressor SSV SLOWLY, watching the compressor suction pressure. If SSV is open too rapidly, potential to pump oil out of crankcase exists. 8. Observe compressor operations for approximately 5-minutes, if there is no evidence of liquid refrigerant returning to compressor open compressor SSV wide 9. System is now up and running 1. Shut dehydrator inlet valve (KING VALVE, KV); system will pump itself down 2. Press Compressor Motor Controller (MCC) STOP push button, even though the compressor has stopped 3. Tag START push button and compressor suction service valve 4. Shut compressor suction and discharge service valves 5. Shut condenser S/W inlet and outlet valves 6. Shut chilled water inlet and outlet valves 7. System is now secured EMERGENCY 1. Depress MCC STOP pushbutton NOTE: If Compressor MCC disconnect switch is opened, install the proper Lockout / Tagout devise and make the appropriate entry in the Lockout / Tagout Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 2 of 17

50 TON AIR CONDITIONING 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure condenser cooling water system is operating 3. Ensure chilled water system is operating, additionally check that all conditioned space thermostats are set properly 4. Check compressor crankcase oil level via sump sight glass; oil level should be between 1/4 to 1/2 of sight glass 5. Verify all system refrigerant valves are lined up as per TABLE 2-1, which is found in the OEM Technical Manual. Only exception being the compressor suction service valve (SSV) 6. Open compressor SSV one full turn 7. Start compressor at Compressor Motor Control (MCC), place POWER and UNIT switches to the ON position. Place the PUMP DOWN switch in the OFF position. 8. Immediately continue to open the compressor SSV SLOWLY, watching the compressor suction pressure. If SSV is open too rapidly, potential to pump oil out of crankcase exists. 9. Observe compressor operations for approximately 5-minutes, if there is no evidence of liquid refrigerant returning to compressor open compressor SSV wide 10. System is now up and running 1. Shut dehydrator inlet valve (KING VALVE, KV); system will pump itself down 2. At the Compressor Motor Controller (MCC), turn the UNIT and POWER switches to the OFF positions 3. Tag START push button and compressor suction service valve 4. Shut compressor suction and discharge service valves 5. Shut condenser S/W inlet and outlet valves 6. Shut chilled water inlet and outlet valves 7. System is now secured EMERGENCY 1. Depress MCC STOP pushbutton NOTE: If Compressor MCC disconnect switch is opened install the proper Lockout / Tagout devise and make the appropriate entry in the Lockout / Tagout Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 3 of 17

50 AIR CONDITIONING SYSTEM CHILLED WATER PLANT 1. Ensure power to water chiller controller and both fan coil unit controllers is on 2. Ensure chilled water expansion tank level is at its proper level 3. Close the Chilled Water System feed and return crossover valves between the 110 Ton Air Conditioning Chilled Water Plant and 50 Ton Air Conditioning Chilled Water systems (valves located in the upper Main Engine Room) 4. Ensure the remaining 50 Ton Air Conditioning Plant Chilled Water System valving are aligned properly 5. Start the chilled water pump by pressing the ON pushbutton, located on the Chilled Water Pump Motor Controller(MCC); pump discharge pressure to be maintained at approximately 30 PSI 6. System is now up and running (steps to be done after 50 Ton Air Conditioning Plant has been secured) 1. Secure Chilled Water Pump by pressing the Motor Controller OFF pushbutton 2. Close the Chilled Water Pump inlet and outlet valves 3. Open the Chilled Water System feed and return crossover valves between the 110 Ton Air Conditioning Chilled Water Plant and 50 Ton Air Conditioning Chilled Water systems (valves located in the upper Main Engine Room) NOTE: If Chilled Water Pump MCC disconnect switch is opened, install the proper Lockout / Tagout devise and make the appropriate entry in the Lockout / Tagout Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 4 of 17

FUEL OIL PURIFIER 1. Determine which storage tank Fuel Oil Purifier (FOP) will pull from and discharge to. Align valves to accomplish this task 2. At the FOP, open the FOP inlet and outlet valves. 3. NOTE: FOP outlet valve is utilized to maintain FOP backpressure. 4. Start the Oil Feed Pump 5. Start the separator at the motor starter, check for the following items: a. Vibration stop separator immediately, check bowl assembly b. Check amp-meter on motor starter, to ensure that separator is at Full speed c. Ensure that no exceptional noise occurs secure separator if any are heard 6. Start the control program 7. Ensure that the following J/W valves are open: 8. System is now up and running; if there are further question is the OEM Technical Manual 1. Stop the Control Program, following events will occur: a. Stop sequence operation LED lit (YELLOW) b. A sludge discharge is performed c. The separator can not be re-started for 3-minutes 2. Stopping sequence is terminated, when display indicates OFF 3. At Fuel Oil Purifier (FOP) close the inlet and outlet valves; close valves FOP was pulling from and discharging to 4. System is now secured Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 5 of 17

MAIN ENGINE / SSDG 1. Verify DAY TANKS Suction / Return valves are open 2. Verify that the SSDG Fuel Oil inlet and return valves are open 3. Verify that at least 2 of the 3 RACOR filters are on-line (inlet / outlet valves are open) 4. Verify that PORT and STARBOARD Main S/W system skin valves are open 5. Verify that SSDG S/W system OVBD valve is open 6. Verify SSDG start air pressure is at 150 PSI or above 7. Verify individual SSDG air start valves are open; blow down air start line lubricator before attempting to start SSDG 8. At individual SSDG LOCAL switch panel, turn the LOCAL / REMOTE switch to the LOCAL position 9. Move the IDLE / RATED SPEED switch to the IDLE position 10. Toggle the START switch to START position SSDG should start within 10 to 15 seconds. If it does not, refer to SSDG / ENGINE OEM Technical Manual 11. After SSDG has been run at IDLE SPEED for 15 to 20 minutes (minimum), switch the IDLE / RATED SPEED switch to RATED SPEED 12. Change the LOCAL / REMOTE switch to REMOTE SSDG control has now changed to MCS 1. Remove electrical load from the SSDG 2. At the MCS console, open individual SSDG mimic 3. Stroke key for SSDG STOP button; this function will slow SSDG speed from RATED to IDLE; SSDG will operate at the IDLE speed for 15-minutes after which time SSDG will shut down 4. Additional way SSDG can be shut down are: a. At SSDG pull the manual FUEL SHUTOFF LEVER; SSDG will stop without the benefit of a Cool Down cycle b. At the SSDG pulling on the Hydro-Mechanical Shutdown Devise KNOB; SSDG will stop without the benefit of a Cool Down cycle c. In the MCS, pull the ENGINE / SSDG REMOTE EMERGENCY STOP LEVER; SSDG will stop without the benefit of a Cool Down cycle Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 6 of 17

MAIN ENGINE LUBE OIL TRANSFER PUMP 1. Verify there is a proper level in the storage tank; record lube oil meter reading 2. Energize the Lube Oil Transfer Pump Motor Controller 3. Verify that the other engine lube oil valves, as well as Main Deck valves are secured 4. Open following valves: a. Storage Tank outlet valve b. Meter inlet and outlet valves 5. Start the Lube Oil Transfer Pump at the local controller 1. Once proper level achieved secure Lube Oil Transfer Pump at the local controller by pressing the STOP pushbutton 2. Open following valves: a. Storage Tank outlet valve b. Meter inlet and outlet valves c. Engine Oil Fill valve 3. Secure power the Lube Oil Transfer Pump at MCS Motor Controller 4. Obtain meter reading, enter amount of Lube Oil used in the Official Engineering Dept. Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 7 of 17

PROPULSION BUS FROM SWBD PROPULSION BUS Dead Bus 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the PROPULSION BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the LOCAL position, remove key 5. At individual SSDG, place the key into the GEN PROP NO. BUS SYNC SWITCH 6. The GEN PROP NO. BUS SYNC SWITCH can be placed in the following two positions: a. AUTO Circuit Breaker will automatically sync with other SSDG that is on the BUS, once satisfied Breaker will close; if BUS is dead then Circuit Breaker will close once AUTO position is chosen b. MANUAL Operator must manual sync the oncoming SSDG to the match the existing SSDG on-line, once all parameters are satisfactory, then Circuit Breaker can be closed; even if BUS is dead, operator must still manually close Circuit Breaker 7. Once Circuit Breaker has closed, place the GEN PROP NO. BUS SYNC SWITCH to the OFF position and place key back into the SWBD LOCAL / REMOTE switch 8. Power is now available on the PROPULSION BUS ONE SSDG ON PROPULSION BUS, ship underway 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the PROPULSION BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Notify BRIDGE of intention to place additional SSDG on PROPULSION BUS; if ship s SHAFT turns are above 400 RPM, request BRIDGE reduce turns below 400 turn for SSDG evolution; once shaft turns are below 400 RPM proceed to next step 5. Verify that SWBD LOCAL / REMOTE switch key is installed and in the LOCAL position, remove key 6. At individual SSDG, place the key into the GEN PROP NO. BUS SYNC SWITCH Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 8 of 17

7. The GEN PROP NO. BUS SYNC SWITCH can be placed in the following two positions: a. AUTO Circuit Breaker will automatically sync with other SSDG that is on the BUS, once satisfied Breaker will close; if BUS is dead then Circuit Breaker will close once AUTO position is chosen b. MANUAL Operator must manual sync the oncoming SSDG to the match the existing SSDG on-line, once all parameters are satisfactory, then Circuit Breaker can be closed; even if BUS is dead, operator must still manually close Circuit Breaker 8. Once Circuit Breaker has closed, place the GEN PROP BUS SYNC SWITCH, to the OFF position and place key back into the SWBD LOCAL / REMOTE switch 9. Once all SSDG parameters have stabilized and are acceptable, inform BRIDGE that they may increase SHAFT back to previous setting Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 9 of 17

PROPULSION BUS FROM MCS No SSDG assigned to STANDBY, DEAD BUS GEN SELECT PROPULSION BUS 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the PROPULSION BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the REMOTE position 5. At SSDG mimic, place the cursor on the ON LINE, PROPULSION button and stroke the mouse button twice 6. SSDG Circuit Breaker will close, power is now available on the PROPULSION BUS ONE SSDG ON PROPULSION BUS, ship underway 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the PROPULSION BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the REMOTE position 5. Notify BRIDGE of intention to place additional SSDG on PROPULSION BUS; if ship s SHAFT turns are above 400 RPM, request BRIDGE reduce turns below 400 turn for SSDG evolution 6. At SSDG mimic, place the cursor on the ON LINE, PROPULSION button and stroke the mouse button twice 7. SSDG will synch will SSDG already on-line, once everything is satisfactory the SSDG Circuit Breaker will close 8. Once all SSDG parameters have stabilized and are acceptable, inform BRIDGE that they may increase SHAFT above 400 RPM ONE SSDG assigned as the STANDBY, DEAD BUS GEN SELECT PROPULSION BUS (only works if there is 1 SSDG on the Propulsion Bus) 1. If the SSDG on-line experiences a fault and shuts down, the SSDG assigned as the STAND-BY, AUTO DEAD BUS PROPULSION SSDG will start and come on line 2. All machinery on the PROPULSION BUS will have to be re-set, see PLANT RECOVERY PROCEDURE for equipment list Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 10 of 17

SHIP SERVICE BUS FROM MCS No STANDBY, DEAD BUS GEN SELECT SHIP SERVICE BUS 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the SHIP SERVICE BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the REMOTE position 5. At SSDG mimic, place the cursor on the ON LINE, SS button and stroke the mouse button twice 6. SSDG Circuit Breaker will close, power is now available on the SHIP SERVICE BUS 7. Close either Transformer # 1 (Circuit PO602 #1) or Transformer # 2 (PO602 # 2)-line side Circuit Breakers; breakers are located on the lower middle section of the 600 VAC SHIP SERVICE BUS 8. At the 480 VAC SHIP SERVICE SWBD, close either Transformer # 1 (Circuit PO602 #1) or Transformer # 2 (PO602 # 2) load side circuit breaker NOTE: Whichever 480 VAC SHIP SERVICE BUS Transformer Circuit Breaker that is closed, MUST match the line side Transformer Circuit Breaker close on the 600 VAC SHIP SERVICE BUS 9. The 480 VAC SHIP SERVICE SWBD is now powered up PARALLELING SSDG ON SHIP SERVICE BUS 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the SHIP SERVICE BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the REMOTE position 5. At SSDG mimic, place the cursor on the ON LINE, SS button and stroke the mouse button twice 6. SSDG will synch will SSDG already on-line, once everything is satisfactory the SSDG Circuit Breaker will close Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 11 of 17

SHIP SERVICE BUS FROM MCS (continued) ONE SSDG assigned as the STANDBY, DEAD BUS GEN SELECT SHIP SERVICE BUS (only works if there is 1 SSDG on the Ship Service Bus) 1. If the SSDG on-line experiences a fault and shuts down, the SSDG assigned as the STAND-BY, AUTO DEAD BUS SHIP SERVICE SSDG will start and come on line 2. All machinery effected by this the loss of the SHIP SERVICE BUS will have to be reset, see PLANT RECOVERY PROCEDURE for equipment list Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 12 of 17

SHIP SERVICE BUS FROM SWITCHBOARD SHIP SERVICE BUS 1. SSDG must be running at RATE SPEED; see MAIN ENGINE SSDG OPERATING PROCEDURE 2. Call up SSDG mimic that will be placed on the SHIP SERVICE BUS 3. Review all SSDG parameters (i.e.: J/W, Lube Oil temperature and pressure, etc); if satisfactory proceed to next step, if not rectify problem before proceeding 4. Verify that SWBD LOCAL / REMOTE switch key is installed and in the LOCAL position, remove key 5. At individual SSDG, place the key into the GEN SHIP SERVICE NO. BUS SYNC SWITCH 6. The GEN SHIP SERVICE NO. BUS SYNC SWITCH can be placed in the following two positions: a. AUTO Circuit Breaker will automatically sync with other SSDG that is on the BUS, once satisfied Breaker will close; if BUS is dead then Circuit Breaker will close once AUTO position is chosen b. MANUAL Operator must manual sync the oncoming SSDG to the match the existing SSDG on-line, once all parameters are satisfactory, then Circuit Breaker can be closed; even if BUS is dead, operator must still manually close Circuit Breaker 7. Once Circuit Breaker has closed, place the GEN SHIP SERVICE NO. BUS SYNC SWITCH, to the OFF position and place key back into the SWBD LOCAL / REMOTE switch 8. Power is now available on the SHIP SERVICE BUS 9. Close either 1500 KVA XFMR # 1 (Circuit PO601) or 1500 KVA XFMR # 2 (PO602); breakers are located on the lower middle section of the 600 VAC SHIP SERVICE BUS 10. At the 480 VAC SHIP SERVICE SWBD, close either XFMR 1500 KVA # 1 Circuit Breaker or XFMR # 2 Circuit Breaker NOTE: Whichever 480 VAC SHIP SERVICE BUS Transformer Circuit Breaker that is close, MUST match the Transformer Circuit Breaker close on the 600 VAC SHIP SERVICE BUS 11. The 480 VAC SHIP SERVICE SWBD is now powered up Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 13 of 17

REFRIGERATION PLANT 1. Check for proper compressor oil level; level should between ½ to ¾ of the crankcase sump sight glass 2. Energize the appropriate unit coolers in the two shipboard refrigeration boxes. If there are any question, see the OEM Technical Manual 3. Verify that all valves are aligned for the appropriate mode of operations, as per TABLE 2-2 & 2-3 in the OEM Technical Manual 4. Verify that auxiliary S/W system is operating, in addition check that the condenser inlet and outlet valves are open 5. Open compressor Suction Service Valve (SSV) one full turn 6. Start the compressor by momentarily pressing the START pushbutton on the compressor Motor Controller (MCC) 7. Continue to open the SSV as suction pressure is reduced. Open SSV slowly to prevent rapid pumping down of the compressor crankcase oil 8. Observe compressor operations for approximately 5-minutes. If there is no evidence of liquid refrigerant returning to the compressor open the compressor SSV wide 9. Unit is now up and running 1. Verify that the dehydrator inlet valve (KING VALVE, KV) is closed and close the dehydrator inlet valve; system will pump itself down 2. Allow compressor to cycle off on low pressure 3. Disable the oil cooler by closing valve 1 on unit being secured 4. Monitor suction pressure gauge; press and hold the LPBP (Low Pressure By-Pass) momentary pushbutton 5. Release LPBP pushbutton when suction pressure drops to 1 to 2 PSI 6. Press Compressor Motor Controller (MCC) STOP push button, even though the compressor has stopped 7. Tag START push button and compressor suction service valve 8. Shut compressor suction and discharge service valves 9. Shut condenser S/W inlet and outlet valves 10. Secure power to shipboard refrigerated box unit coolers 11. System is now secured EMERGENCY 1. Depress MCC STOP pushbutton Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 14 of 17

NOTE: If Compressor MCC disconnect switch is opened install the proper Lockout / Tagout devise and make the appropriate entry in the Lockout / Tagout Logbook Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 15 of 17

REVERSE OSMOSIS WATER MAKER PLANT 1. Open the sea water supply valve 2. Open the product line valve and the ship s potable water supply valve 3. Open the waste brine valve 4. Fully open the high pressure regulating valve by turning it counterclockwise until it stops 5. Position all valves on the membranes isolation manifold in the RUN position with the handle vertical 6. Position the handles of the CLEANING VALVE in the RUN position 7. Press that BOOST PUMP button (YELLOW) to start up the booster pump 8. Press system ON / OFF button (WHITE) to start water maker 9. Once there is adequate water pressure (@ least 15 PSI) is shown on the LOW PRESSURE gauges, turn the high-pressure valve counterclockwise until the pressure reads 1000 PSI, or the product water flow rate reads 2.77 GPM on the flow meter. Note: Do not exceed either of these parameters or damage will occur to membrane assy 10. The RED (non-potable) light should be on for the first three minutes 11. After three minutes, the RED (non-potable) light should go out and the GREEN (potable) light should come on. This indicates that the Water Maker is producing potable water and the quality of the potable water should be displayed in the digital display on the salinity controller @ the units electrical control panel 12. Adjust the high pressure valve until the product water output is between 2.5 and 2.77 GPM, but do not exceed 1000 PSI on the high pressure gauge 13. Periodically, monitor the gauges / lights and adjust as needed to maintain correct pressure and flow 1. Press the system ON / OFF button for the high pressure pump to stop operation of the Water Maker 2. Fully open the high pressure regulating valve by turning it counterclockwise until it stops 3. The Fresh Water Flush (FWF) will automatically activate when the unit is shut down and the display will read FRESH WATER FLUSH. To override the FWF, press the YELLOW button labeled FRESH FLUSH CANCEL. The unit cannot be re-started while the FWF is in operation 4. Close the sea water supply valve, the product line and the potable water supply valve. 5. Close the waste brine valve 6. Unit is now secured Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 16 of 17

Number: ALT 7.5.4 -APPENDIX Revision: 5 Effective Date: 4/15/02 Page 17 of 17