BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

Similar documents
AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

American Weigh Scales, Inc. LB User Manual

STANDARD OPERATING PROCEDURE

User Manual. Portable Balances PL-E

Operating Manual Body fat balance

KERN CM Version /2004

YAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO USA Tel (719) Fax (719)

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

All Purpose AP-Series Operation Manual

StockWeigh 500 D3632 US-B

CHM Introductory Laboratory Experiment (r17sd) 1/13

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

Sartorius Basic plus Service Manual. WBP5007-e95021

SPECIFICATIONS APCEPH1

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

KERN EG/EW Version /02

SAUTER FK Version /2016 GB

Ambient Weather WS-03 Thermo-Hygrometer

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

SPS-5. Rate Computing Scale. Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual. MODEL ½ Digit DRUM SCALE

User Manual GRI- 1500Li

Manual Weighingblock VB2 series and Uniscale

Harvard Trip Balance BA710. Impact Test Equipment Ltd & User Guide. User Guide

Relative Humidity Calibration Kit

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Altimeter and Compass Watch Instruction Manual

Eclipse Precision & Analytical Balances

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

DTG - LCD Digital Temperature Gauge USER MANUAL

Operation Instruction. BSM Series Electronic Precision Balances

General Accreditation Guidance. User checks and maintenance of laboratory balances

How to Achieve Optimal Weighing Performance

ISO 9001 & ISO Rev. G. Authorized Representative in the E.U.: MT Promedt Consulting GmbH Altenhofstrasse 80 D St.

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

M104 Series: Digital Manometer: 0.1 % of Full Scale

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

PTG100 Precision Test Gauge

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Application Notes. SLP85xD Load Cells

Owner s Manual Humiport 10/20

RAM Operation Manual

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Adam Equipment PGL SERIES. (P.N. 9326, Revision C5, March 2009)

Operating Instructions

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

Introduction to Scientific Notation & Significant Figures. Packet #6

BASIC LABORATORY TECHNIQUES (Revised )

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

Heavy Duty Dissolved Oxygen Meter

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

Short manual testo

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

RAM 4021 Operation Manual

DIGITAL AUTOMATIC TYRE INFLATOR

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

Operating Instructions Part No

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

P7911C PressureTrol Controller

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Service Manual. Sartorius Expert. LE-Models Electronic Analytical and Precision Balances. WLE5001-e04022

Gilson Aqua-Check Moisture Tester MA-26X

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Elcometer ISO Groove Depth Checker. Operating Instructions

Infrared Ear and Head Thermometer Instruction Manual

Coriolis Mass Flow Meter

WIKA INSTRUMENT CORPORATION

DPC-30 DPC-100. Reference Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

ActiveYield. Operation and Adjustment

PM105 PRESSURE METER USER S MANUAL

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

RAM 4021-DPX Operation Manual

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

RayPette Plus Autoclavable Pipette. User Manual

Fingertip Pulse Oximeter

Operating Instructions Part No

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Operating Instructions Electronic Precision Balances 1 TECHNICAL DATA UNPACKING AND STANDARD EQUIPMENT INSTALLATION...

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

The pipettes cover a volume range from 0.1µl to 10ml.

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Transcription:

American Weigh Scales BCM-Series User Manual BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.2

BCM-Series Manual Thank you for purchasing the American Weigh BCM-Series digital pocket scale. Please read all operating instructions carefully before use. Scales are precision measuring devices and should always be handled with proper care. To ensure years of reliable service, keep these simple tips in mind: Do not exceed the scale s maximum capacity. This scale has integrated overload protection, but any overload protection has its limits! Avoid exposure to extreme heat or cold. Scales perform best at normal room temperature. If temperatures have changed dramatically, recalibration may be necessary. Allow your scale to warm up for 30-60 seconds before performing calibration (if available). Store your scale in a clean, dry location. Dust, dirt, and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction. Avoid using your scale in close proximity to strong radio wave emitting devices such as cordless phones. Always weigh on a flat and level surface, free from vibrations and drafts. The corner of a room is usually the most stable. Gently apply all items to be weighed. Do not drop items onto the weighing platform. Avoid dropping your scale. The warranty does not cover damage due to rough treatment or overload. Check the batteries first if you are having any trouble with your scale. This simple step can remedy most scale issues. Calibration should be checked and adjusted occasionally as part of routine scale maintenance.

I. Part List 1. Scale 2. Cover/Expansion Tray 3. AAA Batteries (x2) II. Key Description g 1. 3. 2. ON/OFF MODE TARE 1. ON/OFF - Turns the scale on or off. 2. Mode Key - Tap to change the displayed unit of measure. Hold to enter calibration (see VII). 3. Tare Key - Re-zeros the scale. Used to remove the weight of a tray or container. III. Battery Installation Proper Battery Installation

BCM-Series Manual Low batteries can cause inaccuracies in digital scales. If you are experiencing issues with your scale, first try new batteries. Most times, this will solve the problem. 1. Before using the scale for the first time, check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping/storage. 2. If you are replacing the batteries, make sure the positive and negative contacts are properly aligned. IV. Operation 1. Place the scale on a flat, level surface and press the ON/OFF key to turn the scale on. 2. Once the start-up process completes and the scale goes to zero you are ready to weigh. 3. Place the quantity to be weighed onto the weighing platform. 4. Wait a couple seconds for the display to stabilize before taking a weight reading. 5. To turn the scale OFF, press the ON/OFF key again. V. Changing the Unit of Measure 1. Press the MODE key to change the scales displayed unit of measure. 2. If the scale is turned off then back on, it will default to the last unit used. BCM-100 & BCM-650 Units: g (gram) oz (ounce) ozt (troy ounce) dwt (pennyweight) ct (carat) gn (grain)

VI. Using the Tare Feature You can use this scale s tare feature to subtract the weight of an empty container or vessel for net weight determination. NOTE: The weight of the container will subtract from the available capacity (subtractive taring). VII. 1. Place the empty container or vessel on the weighing platform. 2. Press the TARE key once. The display will then reset to zero. If the container is removed, its weight will be displayed as a negative number. 3. You may now fill the container with the quantity to be weighed. The display will show the net weight of the contents. 4. To return to normal weight display (gross weight), remove any items from the weighing platform and press the TARE key again to re-zero the scale. Calibration Initial calibration is performed at the factory. However, the calibration can drift slightly due to stresses from shipping. Also, due to changes in local acceleration of gravity around the world, adjustment is recommended when moving the scale from one location to another. To check calibration: 1. Place the required calibration weight on the scale and note the displayed value. 2. If the displayed value is not within acceptable tolerance (see chart on next page), adjustment is required.

BCM-Series Manual Model Acceptable Calibration Recommended Tolerance (±) Weight Accuracy Class BCM-100 0.02g 100g OIML M2 VIII. BCM-650 0.2g 500g OIML M2 Adjustment 1. Press and hold the MODE key until the display shows CAL 2. Make sure nothing is on the scale platform then press the MODE key again. 3. The display will flash CAL followed by the required calibration weight (see chart above). 4. Place the required calibration weight on the platform. The display will flash PASS then return to normal weighing mode. Adjustment is complete! IX. Troubleshooting Problem: Scale will not turn on Solution: Check the batteries and battery contacts. Problem: Displayed weight fluctuates randomly Solution: Make sure your workspace is stable and free of any air currents or vibration. In some cases, nearby radio wave emitting devices can cause fluctuations. Problem: Displayed weight is inaccurate Solution: Perform a calibration adjustment. If you are still having trouble, contact our warranty department.

X. Error Codes 1. OUTZ - Zero point has drifted out of the acceptable range. Try to perform a calibration adjustment. If the problem persists, the load cell may be permanently damaged due to overloading. 2. O-Ld - Overload. The maximum capacity has been exceeded. Remove the extra weight to avoid permanently damaging the load cell. 3. Lo - Batteries are low. Replace the batteries. XI. Specifications BCM-100 BCM-650 Max. Capacity 100g 650g Readability 0.01g 0.1g Min. Weight 0.03g 0.2g Power 2 x 1.5V AAA Alkaline Dimensions 2.7 x 4.0 x 0.9 in. Platform Dimensions 2.3 x 2.5 in. Warranty 10 Year Limited Warranty XII. Capacity/Readability Charts BCM-100 100g x 0.01g 3.527oz x 0.001oz 3.215ozt x 0.001ozt 64.30dwt x 0.01dwt 500ct x 0.05ct 1543.2gn x 0.2gn BCM-650 650g x 0.1g 22.92oz x 0.01oz 20.89ozt x 0.01ozt 417.95dwt x 0.1dwt 3250ct x 0.5ct 10031gn x 2gn

BCM-Series Manual American Weigh Scales, Inc. Norcross, GA 30092 Made In China to our exact specifications and quality control.