FOAM TANK (1/2) DATA SHEET

Similar documents
FOAM TANK (1/2) DATA SHEET

AIR FOAM CHAMBER DATA SHEET

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

VERTICAL BLADDER TANK

HORIZONTAL BLADDER TANK

Foam Chamber Model-FC

Horizontal Bladder Tanks

Vertical Bladder Tanks

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Model MTB-ASME Horizontal Bladder Tanks

Vertical and Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA OBSOLETE

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

TECHNICAL DATA Q= C. Table 1 - Specifications

Bladder Tank Installation & System Design Information

Wet pipe low flow foam/water system

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

OBSOLETE. Wet pipe low flow manifold system

TECHNICAL DATA. Table 1 - Specifications

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

BALANCED PRESSURE PROPORTIONERS

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

OPERATION AND MAINTENANCE MANUAL

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA CAUTION

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA OBSOLETE

KFI Approved. High Pressure CO2 System Technical Datasheets

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

TECHNICAL DATA. Q = C v P S

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Foam Mixers & Proportioning Systems

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q= Cv S

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

GREIG FILTERS, INC. OPERATION MANUAL

CASH VALVE TYPE KP BACK PRESSURE VALVES

Bermad Model:

Installation Operation Maintenance

MEDICAL EQUIPMENT CATALOG

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

756 Safety Relief Valves

TECHNICAL DATA. Q = C v P S

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Foam Systems. Fire Protection Solutions

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

Models 106-RF / 206-RF Rate of Flow Control Valve

776 Cryogenic Safety Valve

Bermad Pressure Reducing. Model: 42T

INSTALLATION OPERATION MAINTENANCE

ML3M Monnier Miniature Compressed Air Lubricator

L21S/SR/ST Glass Level Gauges

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

VIKING OBSOLETE CONCENTRATE CONTROL SYSTEM OPERATING, MAINTENANCE, AND FILLING MANUAL. Vertical And Horizontal Bladder Tanks

Chlorinator. MODEL C-731 (Floor Mounted)

MANUAL. Sesame. Thermoplastic Tank Technologies

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

29 SERIES - SAFETY VALVE

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Fire & Rescue Service Equipment Manual Branch - Foam Chubb FB5X Foam Making Branch Table of Contents 1 General Description Primary Function...

Installation, Operation, and Maintenance Manual

Anti-flood device Model B-1

TECHNICAL DATA NOTICE

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

TECHNICAL DATA OBSOLETE

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Model: 43T. Bermad Pressure Relief Valve

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

TECHNICAL DATA CAUTION

Transcription:

FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS 06 MODEL NO. YS-FT- 07 APPROVALS UL LISTED FM APPROVED KFEIC KISCO OTHERS 08 CODE & STANDARDS NFPA BS KFPL OTHERS 09 OPERATING CONDITIONS 10 TEMPERATURE MIN. : ( ) OPER. : ( AMB ) DESIGN : ( ) 11 PRESSURE OPER. : ( ) kg/cm² DESIGN : ( ) kg/cm² HYDRO TEST : ( ) kg/cm² 12 FLUID HANDLED WATER AND / OR SEA WATER FOAM-WATER SOLUTION 13 INSTALLATION OUTDOOR AND / OR INDOOR 14 DESIGN FEATURES 15 TANK TYPE HORIZONTAL VERTICAL ATMOSPHERIC INTERNAL BLADDER 16 TANK CAPACITY * LITER ( * GALON ) 17 TANK SIZE * mm(l) x * mm(i.d) 18 INSULATION * 19 FOAM PROPORTIONING (1) PROPORTIONER PUMP PROPORTIONER LINE PROPORTIONER 20 PRESSURE PROPORTIONER PRESSURE SIDE PROPORTIONER 21 (2) SIZE 1" 1-1/2" 2" 2-1/2" 22 3" 4" 6" 8" 23 ANSI KS R.F F.F 24 150LBS 300LBS 10K 20K 25 (3) PROPORTIONING 1% 3% 6% 3% x 6% 26 RATE AFFF FFFP ATC AFFF / ATC 27 (4) ACCESSORIES BLANCED DIAPHRAGM CONTROL VALVE 28 FOAM LIQUID PUMP 29 : GENERAL WEATHER PROOF EXPLOSION PROOF 30 CONTROL VALVE 31 : PNEUMATIC MOTER OPERATED MANUAL 32 : GENERAL WEATHER PROOF EXPLOSION PROOF 33 : BALL BYTTERFLY GATE 34 FOAM FLUSH-IN & FLUSH OUT CONNECTOR 35 FOAM SKID CONTROL PANEL 36 : GENERAL WEATHER PROOF EXPLOSION PROOF 37 PRESSURE RELIEF VALVE 38 PIPING, PRESSURE GAUGE 39 FILLING, DRAIN & OTHER VALVES, ETC. 40 MATERIALS 41 SHELL & BODY CARBON STEEL STAINLESS STEEL 42 LUG & SUPPORT CARBON STEEL STAINLESS STEEL 43 44 REV DATE PRP'D CHK'D APP'D DESCRIPTION 45 0 2006-11-25 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION 46 47 48 49 1 2 3 4

FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (2/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 MATERIALS 02 PUMP CASING CAST IRON CAST STEEL STAINLESS STEEL 03 BALANCED DIAPHRAGM CONTROL VALVE BRASS BRASS STAINLESS STEEL 04 CONTROL VALE CAST IRON CAST STEEL STAINLESS STEEL 05 FOAM SKID CONTROL PNAEL CARBON STEEL STAINLESS STEEL 06 PRESSURE RELIEF VALVE BRASS BRASS STAINLESS STEEL 07 FOAM SUCTION & DISCHARGE PIPE, FITTING, VALVE CARBON STEEL STAINLESS STEEL 08 WATER LINE & FOAM SOLUTION DISCHARGE LINE CARBON STEEL STAINLESS STEEL 09 ACCESSORIES 10 LEVEL GAUGE VENT VALVE FILLING CAP DRAIN VALVE WATER INLET PIPING 11 FOAM OUTLET PIPING VALVE BREATHER VALVE ANCHOR BOLT, NUT & WASHER 12 NAME PLATE ACCESS LADDER EXPLANATION BOARD FOR OPERATING PROCEDURE 13 TEST & INSPECTION 14 DIMENSION INSPECTION WITNESS REVIEW MATERIAL INSPECTION WITNESS REVIEW 15 VISUAL INSPECTION WITNESS REVIEW PERFORMANCE TEST YES NO 16 FINISH UNIT WEIGHT 17 PAINTING * ( * ) Kg 18 COLOR * 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 REV DATE PRP'D CHK'D APP'D DESCRIPTION 45 0 2006-11-25 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION 46 47 48 49 1 2 3 4

BLADDER TANK PROPORTIONING SYSTEM TECHNICAL DATA : TANK MOUNTING TYPE Vertical or Horizontal CONCENTRATE For Vertical Tank : STORAGE 150 litres to 5000 litres. CAPACITY (40 TO 1320 Gallons(US)) For Horizontal Tank : 150 litres to 10000 litres. (40 to 2640 Gallons (US)) RATED PRESSURE FACTORY TEST PRESSURE VESSEL CONSTRUCTION BLADDER 12 Bar (175 PSI) 18 Bar (261 PSI) Carbon steel as per ASME Code Section VIII for unfired pressure vessels. Thermo Plastic,Mullen burst presure +800 PSI. Thickness 1.44 + 0.127 mm CENTRE TUBE EXTERNAL PIPING PVC Water side : Carbon steel seamless pipe sch 40. Foam concentrate side : SS sch 40 VENT AND DRAIN Ball valve (Bronze /SS ) OPTIONAL FINISH ORDERING INFORMATION Sight gauge with shut off and drain valve, ladder and concentrate supply control valve. Epoxy red painted. Please specify 1) Tank type, vertical or horizontal 2) Storage capacity of foam concentrate 3) Model number, size of ratio controller with flow and pressure. 4) Type of foam concentrate to be used and percentage of induction required. APPLICATION The Bladder Tank Foam Proportioning System utilises the water pressure to inject foam concentrate into a water supply and automatically proportions foam concentrate over wide range of flow and pressure, with very low pressure drop. This system does not require concentrate supply pump. SPECIFICATION The Bladder Tank Foam Proportioning System are available with vertical and horizontal bladder tanks. The carbon steel tanks are designed and constructed in accordance with ASME Code Section VIII for unfired pressure vessels. The maximum working pressure is 12 Bar (175 psi) and factory tested for 18 Bar (261 psi). The vertical tank assembly is supported by a continuous skirt with provision for anchoring. The horizontal tanks are supported by two saddles welded to the tank and drilled for anchoring. Tank is provided with lifting lugs. The system is supplied with pressure vessel, bladder, fill and drain valve for water and foam concentrate, ratio controller and vent valve. The ladder and sight glass assembly is supplied as optional item on request. PRINCIPAL OF OPERATION The foam concentrate is to be filled into the bladder very carefully to avoid rupture of the bladder. The instructions for filling are provided with the equipment. Once the main water flow is established and water inlet and foam outlet valves are opened, the water JANUARY, 2006 PAGE 1 OF 4 HD191

enters the area between vessel wall and bladder, applying pressure to the bladder. The foam concentrate is forced out of the bladder through the foam outlet pipe and into the ratio controller through metering orifice. The concentrate pressure and water inlet pressure at ratio controller will be same, as the main water supply pressure is utilised to expel the foam from the bladder. The water flowing through the ratio controller jet creates a low pressure area common both to down stream water and foam concentrate. This injects the concentrate in to the ratio controller through an accurate sized orifice proportioned to water venturi. This ensures correct proportioning over a wide range of flow condition. The bladder tank proportioning system operates on same principle as that of a balance pressure proportioning system. In bladder system, the bladder is used as diaphragm to separate the water and foam concentrate within the tank. The foam concentrate is injected into the ratio controller utilising water pressure. The system is also supplied with foam concentrate control valve as an optional item. The valve allows concentrate flow only when minimum of 3.0 kg/sq.cm. water pressure is established in the system. For pressure drop and flow characteristics refer catalogue of ratio controller. maintenance of the system. 3. Sight glass is not pressure tight, so before taking concentrate level reading, tank pressure must be released. 4. The bladder tank is to be installed under a shade to avoid direct sunlight on the equipment. NOTE 1. The foam concentrate is to be filled in the bladder very carefully to avoid rupture of the bladder. The filling guideline provided with the equipment must be adhered to strictly. 2. Air supply with regulator (0 to 1.0 kg/sqcm) required during filling procedure, to be provided by user/ installer 3.Water supply at 0-1.5 kg/sqcm required for tank filling during commissioning, to be provided by installer/user. INSTALLATION, INSPECTION AND MAINTENANCE An installation, inspection and maintenance manual is provided with each unit. The manual provides detail schematic, initial procedure, inspection and maintenance procedures. The instruction manual must be read carefully and followed during installation and commissioning of the system. After few initial successful tests an authorised person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system regularly, the inspection should verify that no damages have taken place to any component and all the valves are in their proper position as per the system requirement. The system should be fully tested at least once in a year and in accordance with applicable NFPA/TAC code or in accordance to the guidelines of the organisation having local jurisdiction. Do not turn off the system or any valve to repair or test the system, without placing a roving Fire Patrol in the area covered by the system. The patrol should continue until the system is put back in service. Also inform the local security personnel and the control room so that a false alarm is not signalled. CAUTION 1. Do not weld on the tank as it may damage the bladder. 2. Release pressure before an inspection and JANUARY, 2006 PAGE 2 OF 4 HD191

VERTICAL BLADDER TANK PROPORTIONING SYSTEM (OPTIONAL) MATERIAL OF CONSTRUCTION SR.NO. DESCRIPTION SPECIFICATION 1 VALVE SS/BRONZE 2 FOAM CONCENTRATE SS/BRONZE SHUT OFF VALVE 3 WATER SHUT OFF VALVE SS/BRONZE 4 LEVEL INDICATOR GLASS/ACRYLIC 5 PRESSURE GAUGE 0-16 KG/SQCM 6 CHECK VALVE SS/BRONZE 7 SPOOL PIECE CARBON STEEL 8 RATIO CONTROLLER BRONZE 9 BLADDER THERMOPLASTIC RUBBER 10 TANK CARBON STEEL 11 NAME PLATE BRASS 12 WATER LINE PIPING CARBON STEEL 13 FOAM CONCENTRATE SS PIPING JANUARY, 2006 PAGE 3 OF 4 HD191

HORIZONTAL BLADDER TANK PROPORTIONING SYSTEM (OPTIONAL) MATERIAL OF CONSTRUCTION SR.NO. DESCRIPTION SPECIFICATION 1 VALVE SS / BRONZE 2 FOAM CONCENTRATE SS / BRONZE SHUT OFF VALVE 3 WATER SHUT OFF VALVE SS / BRONZE 4 LEVEL INDICATOR GLASS/ ACRYLIC 5 PRESSURE GAUGE 0-16 KG/ SQCM 6 CHECK VALVE SS/ BRONZE 7 SPOOL PIECE CARBON STEEL 8 RATIO CONTROLLER BRONZE 9 BLADDER THERMOPLASTIC RUBBER 10 TANK CARBON STEEL 11 NAME PLATE BRASS 12 WATER LINE PIPING CARBON STEEL 13 FOAM CONCENTRATE SS PIPING JANUARY, 2006 PAGE 4 OF 4 HD191