SC505 Sof Care Inflator. Operating Instructions and Service Manual

Similar documents
Paradise Pump Series Operator s Manual

Alternating Pressure / Low Air Loss Mattress System

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Med Aire Alternating Pressure Pump and Pad System

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Instructions for Cleaning & Maintaining Air Compressor

Instruction Manual for Configura Cushionair Portable Pump

! Warning, refer to accompanying documents.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

INSTALLATION GUIDE Gas Rangetops

Portable oxygen concentrator

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

77-I0PN230 Rev. A. Model 1030 User Manual

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

SPECIFICATIONS ATTENTION

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

RPS900W Redundant Power Supply. Installation Guide.

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

MODELS (2 foot Version) (4 foot Version)

Cocoa Patio Pond with Lit Spillway

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Digital Melting Point Apparatus

Norrsken Family Booklet

DYNAMIC COMPRESSION THERAPY

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

JAVAC EVO-HS REFRIGERANT RECOVERY MACHINE

R E D I C O N T R O L S

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

453 Series Steam Heated Vaporizing Regulator

AIR INLINE METAL SHEAR

Pressure Dump Valve Service Kit for Series 2300 Units

Model 1700 Patient Operating Instructions. Model 1700

Simplified Automated Ventilator Training Slides

MODEL 300 BACKLAPPER OWNERS MANUAL

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

M5400 Operators Manual

200 PSI FAST-FILL AIR SOURCE KIT

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

In Vivo Scientific, LLC INSTRUCTION MANUAL

Pressure Automated Calibration Equipment

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Installation and Maintenance Manual. Compact Medical Gas Outlets

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Vapotherm Q50 Compressor. Instructions for Use

12V AIR STATION ALL-IN-ONE

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

VERTICAL AIR COMPRESSORS

DPC-30 DPC-100. Reference Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

36H SERIES Combination Gas Valve

Budget Range Operators Handbook

3/8" Dr. Air Butterfly Impact Wrench

Installation Instructions Air Compressor Part # 2780, 2781

200 PSI HIGH-FLOW AIR SOURCE KIT

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

TrekMill USER'S MANUAL MM5050

Further technical information is available on

RAM Operation Manual

100C Air Compressor Kit

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Model ASSEMBLY and OPERATING INSTRUCTIONS

2 Gallon, 100 PSI Oilless

BGA158 Series CE Approved Class A Shutoff Gas Valve

5 Channel Calibrator

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Workhorse-15 Oxygen Generator

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

700 SERIES BMS II BUBBLER MONITORING SYSTEM

200 PSI COMPRESSORS - MODEL NUMBERS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

User Manual Models: S36, S40, S50

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

Baseball Pitching Machine

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER MANUAL. JET TST and JET TST S.

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

BGA158 Series CE Approved Class B Shutoff Gas Valve

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

Operating Instructions

POWER ASSISTED BICYCLES OWNERS MANUAL

Transcription:

SC505 Sof Care Inflator Gaymar Industries, Inc. 10 Centre Drive Orchard Park, NY 14127 Toll Free +1 800.828.7341 + 1 716.662.2551 Fax +1 800.993.7890 Outside USA +1 716.662.8636 Outside USA Fax +1 716.662.0730 www.gaymar.com Operating Instructions and Service Manual Sof Care products are made in the USA P/N 101191000 Rev. C 10/10

Table of Contents CONTENTS Section Description Page 1.0 Safety Precautions... 3 2.0 Technical Data... 4 3.0 Description... 4 4.0 Operation... 5 5.0 Cleaning/Storage... 6 6.0 Incoming Inspection/Return Policy... 6 7.0 Functional Check and Safety Inspection... 7 8.0 Troubleshooting... 8 9.0 Parts Replacement... 10 10.0 Drawings/Parts List... 11 11.0 Disposal and Recycling... 14 12.0 Warranty Information... 14 ILLUSTRATIONS Figure Description Page 1 Electrical Schematic... 11 2 Parts Drawing... 12 3 Spare Parts List... 13 Sof Care is a registered in the U. S. Patent and Trademark Office. 2010. Gaymar Industries, Inc. All rights reserved. www.gaymar.com 2

11.0 Disposal and Recycling Metal parts of the device should be disposed of as scrap metal. Synthetic materials, electrical components, and printed circuit boards should be disposed of as electrical scrap. Material must be disposed according to the relevant local legal regulations. Consult specialized disposal companies for this purpose. Please contact local city/community administrations concerning local disposal companies. 1.0 Safety Precautions The user must understand this Operator s Manual and all precautions prior to use. Handle this system with the same care you would use when handling precision medical equipment. Review the following safety precautions prior to using the inflator. DANGER Explosive hazard. Do not use in the presence of flammable anesthetics. Risk of electric shock. Disconnect power before servicing inflator. 12.0 Warranty Information ALL GAYMAR EQUIPMENT AND PRODUCTS ARE WARRANTED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP UNDER NORMAL USE AND OPERATION. Warranty entitlements on the inflator are as follows: Free replacement of the SC505 Inflator unit where defects in materials and/or workmanship are evident at time of delivery. All labor and parts are free of charge for a period of one full year from the date of purchase, providing the equipment is returned prepaid to Gaymar Industries. (See Section 6.0) WARNING Repairs should be performed only by qualified personnel such as biomedical electronic technicians or certified clinical engineers familiar with repair practices for servicing medical devices and accessories in accordance with Sections 7.0, 8.0 and 9.0 of this manual. Damage to the inflator or malfunction could otherwise result. CAUTION Check skin condition daily. Consult physician if any redness or skin break occurs. Left untreated, serious injury could result. For grounding reliability, plug inflator only into a grounded outlet labelled Hospital Grade. Do not position unit near any objects that can generate a strong electrical/magnetic field. Unit has been investigated to be in compliance with IEC60601-1-2. Potential electromagnetic interference may result. 14 3

2.0 Technical Data Model number SC505 Classification Class 1 grounded equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. Regulatory UL60601-1, CSA C22.2 No 601.1-M90 Ingress IPX0 EMC IEC 60601-1-2:2007 CISPR 11/EN 55011, Class A, Group 1 ISM equipment Mode of Operation INTERMITTENT Operation 1 Minute ON/10 Minutes OFF Voltage Current Frequency Fuses Power Cord Static Pressure Operating Temperature Storage Temperature Storage Humidity Weight Size 3.0 Description 120 VAC 2.1 A 60 Hz Two 5x20mm Fuses: 2.5A, 250V, T, L Detachable, 15', #18AWG minimum with ground wire. 30 mm Hg minimum; 37 mm Hg maximum 60-90 F (16-32.2 C) -20-120 F (28-48 C) 0%-95% Non-Condensing 3 lb (1.4kg) 4" X 10.5" (10.5cm x 26.7cm) The SC505 Sof Care Inflator is Class 1 device designed for the intermittent operation required to fill Sof Care series cushions. Item Description Part Number 1 Handle Assembly 77550000 2 Switch Assembly Kit 101335000 3 Inflator Adaptor 11299000 4 Gasket 05423000 5 Test Kit 77553000 6 Foam Gasket 05892000 7 Screen 05506000 8 Trim (12" Long) 81175000 9 Power Entry Module 91368010 10 Cordset Lock 78154000 11 Power Cord 10031000 12 Fuse (Not Shown) 10219 Figure 3 - Spare Parts List CAUTION The use of other parts or materials other than those specified in the table above can degrade the safety of this device. By using the SC505 Sof Care Inflator, the Sof Care Cushion can be correctly filled with the proper air pressure for each patient. 4 13

4.0 Operation 8 1. Plug the power cord into a properly grounded outlet. 2. Insert the inflator into the air valve of the Sof Care cushion. 11 3. Switch the ON/OFF switch to the ON position for: 60 seconds for Sof Care Bed Cushions, Strecher Cushions and Heel Cushions. 30 seconds for Sof Care Operating Room Cushions. The inflator automatically avoids putting too much air into the bed cushion. 1 4. Remove and swich the ON/OFF switch to the OFF position. Quickly replace and tighten the Sof Care Cushion valve cap. Ensure inflator remains OFF for 10 minutes before next use. 5. Perform a HAND CHECK: 2 6 9 10 Place hand under the Bed Cushion, beneath the patient's buttocks. Hand must be positioned with palm up and fingers flat. (If fingers are flexed, the HAND CHECK will be misleading.) If patient does not touch hand, the Bed Cushion is correctly inflated. If patient does touch hand, reinflate until patient's buttocks no longer touch hand. 3 7 4 Perform the HAND CHECK every 8 hours and after each inflation. 5 For further cushion instructions refer to the Instructions for Use booklet enclosed in Sof-Care Cushion package. Figure 2 - Parts Drawing 12 5

5.0 Cleaning and Storage Do not allow liquids to enter housing. Unplug the power cord. Clean the housing with a mild detergent and damp cloth. Wipe dry before operating. Cleaning should be performed as often as required by institution protocol. 10.0 Drawings/Parts List 6.0 Incoming Inspection and Return Policy 1. Check the shipping carton for damage immediately after receipt. If package damage is discovered, the device should be unpacked with the carrier s agent present. Make a claim immediately to the carrier for damage. 2. Do not return damaged goods without notifying the carrier. If goods damaged during shipping are returned to Gaymar without notifying the carrier, Gaymar will assume the repairs will be made at the customer s expense. 3. Merchandise returned to Gaymar must be accompanied by a Return Goods Number (RG#) given by Gaymar, authorizing goods to be returned. Contact Customer Service at: 1 800 828-7341, or (716) 662-2551 Figure 1 - Electrical Schematic 6 11

9.0 Parts Replacement [refer to figures 1-3] WARNING Unplug the power cord before replacing any parts. NOTE: Removing the front cap may result in air leakage. If necessary, use a replacement front cap gasket (item 6, page 13). 9.1 Fuses Unplug the power cord. Remove the front cap for access to the interior of the inflator. Replace blown fuse(s) with 5x20mm, 2.5A, 250V, T, L fuses as indicated on the label inside the device. Replace the front cap. 9.2 Power Switch Unplug the power cord. Remove the front cap to access the interior. Remove the glamour cap from the switch. Remove the two screws securing the switch to the housing. Disconnect the black and white switch wires from the two fuse holders. Cut and remove ty-wraps. Remove two screws from fuse plate and push plate aside to gain access to switch. Cut off the two splice connectors from the two motor wires. Strip the two motor wires to 1/4". Using a crimp tool, crimp the motor wires to the butt connectors on the new power switch assembly, polarity does not matter. Place the switch back in the inflator housing with the push on terminals facing the top. Secure switch with the two screws and place the glamour cap back on the switch. Remount fuse plate and secure with two screws. Reconnect the push on terminals to the fuse holders ensuring the white wires connect to each other and the black wires connect to each other. Fasten one wire splice to each fuse holder, through the fuse holder plate, with a ty-wrap. Replace the front cap. Procedures within this section should be performed only by qualified personnel such as biomedical electronics technicians or certified clinical engineers familiar with repair practices for servicing medical devices and accessories in accordance with this manual. Damage to the inflator or malfunction could otherwise result. 7.0 Functional Check and Safety Inspection Perform the following procedures every 12 months (or as specified in the facility's preventitive maintenance program) and after each repair to assure optimum performance, dependability, and safety. 7.1 Enclosure Unplug the power cord. Examine the enclosure. Check that screws are tight, labels and markings are legible, and air vents are free of dirt. Examine the power cord for cracks and bent, broken, or missing pins. 7.2 Ground Resistance Measure the resistance between the ground pin on the power cord plug and the screw on the handle. It should be less than 0.5 ohms. If it is greater than 0.5 ohms, check the condition of ground connections inside the inflator. Remove the front cap to access the interior of the inflator. Refer to Section 9.0. 7.3 Current Leakage Test Measure the current leakage between the inflator enclosure and 9.3 Motor ground. It should not exceed 500 µa for any combination of input line polarity and ground conductor open. If the inflator fails the current The motor is designed for long, trouble-free service. Motor leakage test, return the inflator to the factory or an approved service replacement is difficult. If the motor fails, return the complete inflator to center for repair. (See Section 6.0, Incoming Inspection and Return the factory. (See Section 6.0, Incoming Inspection and Return Policy.) Policy.) 10 7

7.4 Pressure Check [refer to figure 2] Gaymar Test Tool P/N 77553-000 adapts the SC505 inflator to tubing (3/16" ID) for connection to a manometer. See figure 2, item 5. Attach the tubing end to a standard manometer. Hold the inflator and test tool together firmly. Turn the inflator on. Verify that the output pressure is at least 30 mm Hg, but not more than 37 mm Hg. If the unit fails pressure check, refer to Section 8.0 paragraph 5. 5. If the inflator fails the pressure check, check the integrity of the gasket between the front cap and the enclosure. If the adapter assembly was removed, check the integrity of the gasket between the front cap and the adapter. Replace gasket if missing, damaged, or otherwise unusable. If the problem persists, return the inflator to the factory or an approved service center for repair (See Section 6.0). 8.0 Troubleshooting [refer to figure 1] WARNING Always perform the Functional Check and Safety Inspection (Section 7.0) after making repairs and before returning the inflator to use. Failure to do so could result in user injury. 1. If the inflator fails to operate, make sure it is plugged in and the receptacle has power. Next check for a blown fuse. If a fuse has blown, replace it per Section 9.1. If a fuse blows repeatedly, check wiring or switch for electrical short. If the problem persists, return the complete inflator to the factory for repair (See Section 6.0). 2. If the unit fails to operate with a new fuse, check for continuity of the motor and switch separately. 3. If the motor shows no continuity, return the complete inflator to the factory or to an approved service center (See Section 6.0). 4. If the switch shows no continuity in the on position, replace it per Section 9.2 or return the complete inflator to the factory for repair (See Section 6.0). 8 9