Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171

Similar documents
DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

S Surge Arresters

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

Page 1 of 1 04/19/13 SBR

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Anchor Component Material Standard Mechanical Properties

COOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

GP100 SERIES ENDURANCE PLAYGROUND SYSTEMS. Installation and Assembly Instructions. Gared Holdings, LLC 9200 E. 146th St. Noblesville, IN 46060

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

Divider Systems. Rear Tire Divider (RTD) Section 4. Model Years Model Years Model Years

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

3/8" Safety Cable Systems

Only. Gives You the TechLock. System Advantage ASSEMBLY, DISASSEMBLY AND TROUBLESHOOTING INSTRUCTIONS FOR 3000 SERIES FONTAINE

-SWEPT AWAY- Description & Overview. VEX Classroom Competition Swept Away

Soccer Goal. Model: SG20 Series. Installation, Operation and Maintenance Instructions

RZR 900 Hitch Mount Plate

B104ZN BLTD 4H 90 L Bracket. Features. Material, Color, and Finish. Dimensions and Weight. Long Description

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

-Round Down- Description & Overview. VEX Classroom Competition Round Down

MSA Confined Space Entry Equipment

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

Low Wind High Yields Series

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

Troyer s Gourd Rack 8 unit F R H O P

INSTALLATION INSTRUCTIONS FOR: RE4548 JK FRONT COILOVER KIT

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

3 AND 6 SIDE ARMS, STRAIGHT/TAPERED TOWER SECTIONS

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

WHEATLEY Series 500 Swing Check Valve

BICYCLE ACCESS RAMP INSTALLATION INSTRUCTIONS. Customer Service all4cycling.com.au

Using Your Bike Friday : Folding Rear Rack

Effective January 2017 Supersedes July 2011 (I ) VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions

Assembly Instructions. -Cantilever Boat Lifts

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

INSTRUCTIONS 360 Y-DROP HAGIE STS 2015

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

This document to be used with Hurley traditional Davits

Product Catalog and Pricing

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

Installation Instructions

C-M Precast Traffic Islands Index

5. STRUCTURAL ANALYSIS

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

61-31 Corrugated Radiators

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

Tripod Setup Guide (M-TPx)

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

TRAVSMART permanent single-cable horizontal lifeline system

MANITOWOC MODEL TON CAPACITY

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

COMPETITION EQUIPMENT. Enjoy the game

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

CHAINLESS ANCHORING SYSTEM USER MANUAL

EOS LED Pendant Mounted Luminaire

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

COPY. **For U.S. and Canada Customers ONLY:** IF ASSISTANCE IS NEEDED,

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

VISIT THE LIFETIME WEB SITE: **For U.S. and Canada Customers ONLY:** IF ASSISTANCE IS NEEDED,

B-LINE SERIES. Spring steel fasteners KWHS-15. KwikWire. Hanging system

Installation, Operation and Maintenance Manual for Back Pressure Regulator

V-PLOW. ACCUFLO Conveyor Belt Cleaning System MAX SYSTEMS GUIDE. Engineering. LIB-CP-SYS-01-E Rev.9. Page 1

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

Vertical and Horizontal Bladder Tanks

TOWER INSPECTION REPORT

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System

Drop-In Internally Threaded Anchor (DIAB) Mechanical Anchors. Key features. Material: Carbon steel. Coating: Zinc plated

Lock-N-Load. Bullet Feeder

RSL TOWER KITS RSLL-01-A1 RSL GENERAL NOTES

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

30T A/Manual Hydraulic Shop Press

Backboard and Rim Owners Manual

E Lightband Compression Tool Operating Procedure

Installation Guide RHT-380. This Manual Must Be Read Before Operating The Equipment CUSTOMER COPY

Table of Contents. Introduction... 2 Product Overview...2 Safety Information...2 Safety Notes...2

1. Section Summary for loose climbing equipment provided by Owner. 2. Section "Cast in Place Concrete"

Change Crossarm Insulator with Hotsticks

American Flagpole & Flag Co. 1(800)

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

Flagpole Selection Guide

ELECTRIC OPERATING PROCEDURES Date: 11/01/06

IMPORTANT: RECEIVING INSTRUCTIONS:

REVIEW ALL INSTALLATION NOTES PRIOR TO INSTALLATION!

Universal Anchoring Adapter For Mercedes

Thank you for purchasing a Porta-Dock product! *Please read and follow these instructions step by step*

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

Spring steel fasteners KWHS-14R. KwikWire. Hanging system

Instant Garage 20' x 12' 3" x 8' 3"

LEGACY II TM STARTING PLATFORMS

Transcription:

Transformer Business Department Regulator & Inductive Products Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171 Last Update 11-19-2013 Tom Dauzat, Shreveport 1

ASSEMBLY INSTRUCTIONS CONTENTS PAGE REFERENCES....2 INTRODUCTION....3 SUB-BASE HEIGHTS...3 I. Adjustable Construction.....4 II. Post Construction.....7 III. Formed Channel Construction.....9 IV. Short Channel Construction With Cross Tie-Rod....11 V. Short Channel Construction..13 RENEWAL AND SPARE PARTS....15 SERVICE....15 REFERENCES PAGE SUB-BASE CONSTRUCTION SKETCHES A. Adjustable....5,6 C. Post.....8 D. Formed Channel.....10 E. Short Channel With Tie-Rod.... 12 F. Short Channel......14 SUB-BASE CONSTRUCTION TABLES I. Adjustable...4 II. Post...7 III. Formed Channel...9 IV. Short Channel With Tie-Rod...11 V. Short Channel...13 NOTE The equipment covered by these operating instructions should be operated and serviced only by competent technicians familiar with good safety practices, and these instructions are written for such personnel and are not intended as a substitute for adequate training and experience in safe procedures for this type of equipment. 2

INTRODUCTION The Sub-Base assembly for the type ML 32 step voltage regulator is an older design whereas the VR-1 is most recent. There are various sizes and differ in construction depending on the unit catalog number and overall regulator height desired. In order for each size to serve multiple catalog numbers, sub-base holes are drilled on top channels and cross tie rods, when furnished and adjustable sub-bases are made with adjustable legs to conform to the desire height NESC requirements for lowest live parts. The Sub-Base assembly is shipped disassembled. Directions for assembly are included in these instructions. They include sketches and tables. To ascertain the construction to be used on a particular regulator check the sketch with the parts furnished. Refer also to the section SUB- BASE HEIGHTS The complete Sub-Base assembly should be fastened firmly to a level foundation concrete pad with anchor bolts. It should be thoroughly and effectively grounded utilizing the regulatorgrounding fixture attached to the regulator base or tank wall. WARNING: TO PROVIDE MAXIMUM PROTECTION TO THE OPERATOR, THOROUGHLY AND REFECTIVELY GROUND THE REGULATOR. GROUNDING CONDUCTOR SIZE SHOULD BE IN ACCORDANCE WITH NEC AND ANIS REQUIREMENTS TO ELIMINATE THE POSSIBILITY OF BURNING-OFF IN CASE OF A LINE GROUND. DO NOT REMOVE THE GROUND CONDUCTOR WHILE THE REGULATOR IS ENERGIZED. SUB-BASE HEIGHTS: To simplify choice of sketches and tables the following measurements are included. Height Dimension (Inches) Parts Assembly USE 24.5, 27.5, 30.5, 33.5 Sketch A,B, Table I 15.5, 18.5, 21.5, 24.5 Sketch A,B, Table I 33.5, 36.5, 39.5, 42.5 Sketch A,B, Table I 23-3/4, 33-3/4, 44 Sketch C, Table II 28-3/4, 38-3/4, 49-3/4 18-1/2 Sketch D, Table III 13 Sketch E, Table IV 7-1/4 Sketch F, Table V 3

I. Adjustable Sub-base Construction 1. Assembly should be completed on a dry, flat surface. See Sketch A. 2. Extension legs (Item 2) must be assembled on the inside of the fixed-base support legs (Item 1). 3. Each extension leg (Item 2) must be attached using (2) carriage bolts on each side of the leg and spaced in overlapping holes farthest apart (Ensure Square Head fits in Square Hole). 4. Carriage Bolts used to attach the extension leg to the fixed support leg should be 0.5- inch diameter. 5. Qty. of 4 3/4 inch diameter zinc plated or stainless 5-inch long bolts should be used to attach regulator to the sub-base. 6. Bolts and washers are assembled per the Bolt Assembly Drawing. See Detail A. 7. The sub-base should be mounted to a foundation with qty. 4 3/4 inch diameter bolts in each of the 4-leg surface mounting brackets. See Detail B. 8. NOTE: For seismic area zone, use x-bracing provided. See Sketch B for Configurations. TABLE I ADJUSTABLE SUB-BASE GROUPS PART NUMBERS ADJUSTABLE HEIGHTS 21 & 25 Tanks 7025B108G01 24.5, 27.5, 30.5, 33.5 21 & 25 Tanks 7025B108G02 15.5, 18.5, 21.5, 24.5 21 & 25 Tanks 7025B108G03 33.5, 36.5, 39.5, 42.5 28 Tank 7025B108G06 24.5, 27.5, 30.5, 33.5 28 Tank 7025B108G07 15.5, 18.5, 21.5, 24.5 28 Tank 7025B108G08 33.5, 36.5, 39.5, 42.5 4

Sketch A Sketch B 5

Sketch B cont. 6

II. Post Construction (Obsolete Design) 1. Determine dimensions between regulator base mounting holes form the regulator outline. Refer to TABLE II for channel angle mounting holes to be used. 2. Assemble CORNER posts (legs) to the proper holes in the bottom channels. See Sketch C, which shows hardware. 3. Insert bottom cross tie in holes provided on bottom channels and secure in place maintaining 28.5 between inside of channels. 4. Assemble top angles to corner post (legs). Observe positioning of beveled edge (* in Sketch C ). Attach U-bolt to firmly secure top angles to corner posts. 5. Assemble gusset braces to corner posts with U-bolts. 6. Position regulator sub-base and fasten using 3/4 inch hardware. 23-3/4, 33-3/4, 44 28-3/4, 38-3/4, 49-3/4 TABLE II POLE SUB-BASE HEIGHTS (NOT ADJUSTABLE HEIGHTS) REGULATOR BASE DIMENSIONS BETWEEN MOUNTING CHANNEL MOUNTING ANGLE MOUNTING 14-312 1 1 16 2 2 19 3 3 21 4 4 23 5 5 7

8 Sketch C

III. Formed Channel Construction 1. Determine dimensions between base mounting holes form the regulator outline. Refer to TABLE III for channel mounting holes to be used. See Sketch D. 2. Assemble angle M to sides of channel. 3. Assemble support plate P, refer to proper L dimension as called for in TABLE III. 18.-1/2 TABLE III FORMED CHANNEL SUB-BASE HEIGHT (NOT ADJUSTABLE HEIGHTS) REGULATOR BASE SUPPORT CHANNEL ANGLE M DIMENSIONS PLATE MOUNTING MOUNTING BETWEEN MOUNTING P L (DIM.) 16 4 3 6-1/2 19 1 1 13-1/2 21 2 2 13-1/2 23 3 3 13-1/2 9

Sketch D 10

IV. Short Channel Construction With Cross Tie-Rods 1. Determine dimensions between regulator base mounting holes form the regulator outline. 2. Refer to TABLE IV for channel mounting holes to be used to mate with the regulator base. 3. Refer to Sketch E for proper H width dimensions. Apply cross tie-rods as shown in Sketch E insert. TABLE IV 13 SHORT CHANNEL SUB-BASE (CROSS TIE-RODS) HEIGHT (NOT ADJUSTABLE HEIGHTS) REGULATOR BASE DIMENSIONS BETWEEN MOUNTING CHANNEL MOUNTING ANGLE MOUNTING 19 1 15-3/4 21 2 17-3/4 23 3 19-3/4 11

12 Sketch E

V. Short Channel Construction 1. Determine dimensions between regulator base mounting holes from the regulator outline. Refer to TABLE V for channel mounting holes to be used to mate with regulator base and proper separation per H width dimensions. See Sketch F. TABLE V 7-1/4 SHORT CHANNEL SUB-BASE HEIGHT (NOT ADJUSTABLE HEIGHTS) REGULATOR BASE DIMENSIONS BETWEEN MOUNTING CHANNEL MOUNTING ANGLE MOUNTING 21 1 18 23 2 20 13

14 Sketch F

RENEWAL AND SPAER PARTS Orders for renewal or supply parts should be placed with the nearest Apparatus Sales Office of the General Electric Company. Specify the Serial Number, the quantity required, description of the part and the Catalog or Drawing Number of the part whenever possible. Always specify the Serial Number appearing on nameplate. Any Renewal parts supplied will be manufactured from the same or similar materials as those used originally. Successful operation of the renewal parts is contingent upon proper field assembly, the condition of the remaining parts, and a thorough drying cycle if moisture has entered the regulator. SERVICE If you need to repair, recondition or rebuild any electrical apparatus, a General Electric Service Shop near you is available for work in the shop or on your premises. Latest factory methods and genuine G-E Renewal Parts are used to maintain the original performance f your General Electric equipment. For full information about these services, contact the nearest General Electric Service Shop or Apparatus Sales Office. 15