ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Similar documents
Multiple Gas#5 GC configuration Jan 2016

SRI Multi Gas Analyzer 2016

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

SRI 8610C Gas Chromatograph Multiple Gas #3 GC configuration

System Overview. TCD Detector temperature setpoint Regulator

New improved robot for gas kinetics

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Automated Determination of Dissolved Gases in Water Anne Jurek

GCMSD-Headspace Analysis SOP

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Rapid and Reliable Detection of Dissolved Gases in Water

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

This GC has two columns (I think new columns can be ordered from Restek)

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Buck Scientific, Inc.

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Agilent 490 Micro GC Natural Gas Analyzer

Applied Technology and Best Practices in CEE. Conference

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

6890 GC Site Preparation

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Manual Solvent Purification System. Innovative Technology, Inc.

Experiment 18 Properties of Gases

APPLICATION NOTE. GC Integrated Permeation Device

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Supporting Information for Measurement of Dissolved H 2, O 2, and CO 2 in Groundwater Using Passive Samplers For Gas Chromatographic Analyses

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Improved Monitoring of Dissolved Transformer Gases on the Basis of a Natural Internal Standard (NIS)

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

5890II GC Standard Operating Procedure 9/2/2005

Figure. Experimental set up of catalyst, reactants and product syringes.

Generating Calibration Gas Standards

Agilent 7697A Headspace Sampler

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

REFINERY GAS ANALYSIS BY GAS CHROMATOGRAPHY

The Helium Leak Detector

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

ISO INTERNATIONAL STANDARD

7820A GC Site Preparation Checklist

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Ultimate Performance in Gas Chromatography

NOTE: Performance of this method should not be. attempted by persons unfamiliar with the operation of a gas

Carrier Gases in Capillary GC

3 Flow and Pressure Control

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Zebron Gas Management

Online DGA-monitoring of power transformers

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

AKTA pure 25 New Owner s Intro

Unit 9 Packet: Gas Laws Introduction to Gas Laws Notes:

Sampling Considerations for Equilibrium Dissolved Oxygen [DO] Sensors

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

CP-3800 GC Operator s Manual

Since the beginning of production of oil for transformers

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Determining the Oxygen Transmission Rate of Carton Packages

Carrier Gases in Capillary GC

Mass Spec will not Autotune

Using the Akta Prime plus October 22, 2012

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Svensk läkemedelsstandard

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Dissolved Gas Analysis - Past, Present and Future

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

FUNDAMENTALS OF GAS CHROMATOGRAPHY, GAS QUALITY & TROUBLESHOOTING Larry Ewing Chandler Engineering Company LLC

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Fundamentals of NGL Sampling Systems. By Dominic Giametta & Jim Klentzman

6890 GC Not Ready Messages (A16010)

Chapter 14 Practice Problems

SOP: Buck Scientific BLC-20P HPLC Operation

Best Practice for Identifying Leaks in GC and GC/MS Systems

be present throughout these services; otherwise, they will miss important operational, maintenance and safety information.

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Basic Flows in a Microfluidic Device

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

28 Site Preparation. Supplying valve actuator air

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

CTB3365x Introduction to Water Treatment

Comparison of Different DGA (Dissolved Gas Analysis) Methods for the Condition Assessment of Power Transformers

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

no peaks missing peaks too small peaks increasing retention decreasing retention

CONNECTIONS. The Thermal Conductivity Detector

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Transcription:

The SRI ASTM 3612/TOGA/ Dissolved Gas GC configuration ( TOGA GC ) permits measurement of gasses dissolved in water, oil or other liquids, and is based on the requirements of ASTM method 3612, option C, which specifies the use of headspace to extract the gas molecules from the liquid. A headspace vial like the 40ml vial shown above is half filled ( 20ml ) with liquid and then the gas above the liquid is purged with inert gas like argon, nitrogen or helium. Gases ( CH4, CO, CO2 etc ) which are dissolved in the liquid then escape into the inert headspace where they accumulate until an equilibrium is reached. Those gases are then injected into the GC. Page 1

The GC is configured with two detectors ( TCD and FID/Methanizer ) which are connected in series at the end of the two separation columns ( Haysep-D and Haysep-N). A 10port gas sampling valve ( GSV ) injects 1ml of headspace gas into the columns where the various gas moleclules are separated. The valve is connected as shown. This diagram is also displayed on the cover of the GC s valve oven. The valve is plumbed to backflush the columns when the peaks of interest ( H2, CO, CO2, ethane, ethylene and acetylene have eluted. Before measuring liquids, it is helpful to inject the calibration gas itself with no liquid in the vial. This permits the operator to optimize the separation of the gases of interest, identify and calibrate the peaks etc. Take a new empty 40 ml vial with septum cap ( CRS part# 279545 www.chromres.com ) and slide it into the headspace sampler from the bottom. Page 2

Make sure the 40ml vial is inserted all the way so you can see the septum. As the vial is pushed upwards, the septum is pierced by two needles. Find some calibration gas which contains the molecules you want to measure in the liquid. In this example we are using a mix which contains 1% each of H2, O2, CO, CH4 and CO2 in nitrogen. Other gas mixes are available which might also include C2H6, C2H4, C2H2 and others. FPD sig Withdraw 20ml of the calibration gas into a 60ml syringe with 27gage needle ( supplied with GC ) and then push the calibration gas into the vial as shown. Pierce the vial s septum with the 27 gage needle at an angle. Use a new septum each time since the holes from a previous puncture will leak. Page 3

As you push the calibration gas into the vial you should see the vial pressure increase. FPD sig 20ml into a 40ml vial should result in a pressure of.5bar ( 8psi ). The pressure will remain indefinitely if the vial is not leaking. Because 20 ml of calibration gas was added to 40ml of air in the vial the resulting concentration of the calibration gas in the vial is 3 times less that it was coming out of the calibration gas cylinder. Use the View/Relay-Pump Window to actuate Relay C. This opens the solenoid mounted at the rear of the valve oven which releases the pressure in the vial through the 1ml sample loop. ( See the valve diagram to visualize the path that the gas takes ). The loop is now filled with diluted calibration gas. Page 4

We used the Temperature program and Event table shown at right for this analysis. Nitrogen carrier was set at 20psi on the GC. The two columns were 2meter Haysep-D and2meter Haysep-N in series. The Haysep-N was the upstream column with the valve in the INJECT position. A chromatogram such as the one shown should result from the injection of a calibration gas standard containing CO, CO2, methane, ethane, ethylene and acetylene. The TCD measures hydrogen and oxygen, while the FID/methanizer shows CO, CH4, CO2 and the C2 compounds. This chromatogram was run using nitrogen carrier gas. FID/ methanizer signal TCD signal Page 5

Revised Ocober 2013 Gas calibration standards are readily available, but liquid standards ( known amounts of gases dissolved in liquids ) are not easily found, so you might have to make your own. ASTM 3612 has a procedure, but it is cumbersome. Another standard preparation method is to bubble calibration gas through a liquid until the liquid and calibration gas are in equilibrium. Supplied with the TOGA GC system is a pressure regulator, restrictor tube, silicone tubing with Luer lock, and two needles for this purpose. Connect the regulator to the calgas cylinder as shown and adjust the pressure so a slow stream of bubbles comes out of the needle which is positioned below the surface of the liquid. You may have to lay the VOA vial down on its side. The 2nd needle ( 27gage ) is inserted to vent the calgas from the top of the vial. After one hour or so, the calgases dissolved in the liquid should have reached equilibrium. From the Internet you can get a table which shows the amount of each gas which will be dissolved in the liquid once equilibrium is achieved, at least for water. Slow bubbles The solubility of gases in transformer oil is assumed to be the same as for water, although this is not completely accurate, and different oil types will exhibit different solubilities. Page 6

When gases are dissolved in liquids the concentration of those gases can be described by the volume of gas in a volume of water ( volume% ) or by weight of gas in a weight of liquid, or volume of liquid, or by moles. There is a very large difference between volume%, weight% and mole%. Volume% is the method many people use. For example: From the Internet we learn that the weight of CO2 in 100ml of water when completely saturated with a pure CO2 purge gas is 0.169grams. By multiplying this by a series of unit conversions we get 1.45ml CO2 in every ml of water, or 145%. If our calgas contains1% CO2 ( which it does in this case ) then the water would contain 1.45% CO2 ( 14,500ppm ) by volume. By weight% the answer comes out to be 16.9 ppm By mole% the answer comes out to be 1.08ppm So there is at least a factor of 10000 difference between vol% and mole% Volume% calculation assuming 100% CO2 at 1 atm and saturated.169gramco2 1moleCO2 24litersCO2 1000mlCO2 = 1.45ml CO2 100mlH2O 28gramCO2 1moleCO2 1literCO2 1.00ml H2O *Grams of gas dissolved in 100 g of water when the total pressure above the solu on is 1 atm. Oxygen.0043 Acetylene.117 Nitrogen.0019 Hydrogen.00016 Methane.0023 CO.0028 CO2.169 Ethane.0062 Ethylene.0149 Reference: G.W.C. Kaye and T.H. Laby, "Tables of Physical and Chemical Constants," 15th ed., Longman, NY, 1986, p. 219 Page 7

The chromatogram at right show the results for a 20ml water standard which was saturated with a 1% calgas in Nitrogen. The volume% concentrations in the water would have been: Hydrogen 192ppm Oxygen Nitrogen CO Methane CO2 64.5ppmv 1539ppmv Since this was the 94% balance in the calgas 33.6ppmv 34.5ppmv 14,500ppmv Had they been present in the calgas, the C2s would have been: Ethylene 128ppmv Acetylene 108ppmv Ethane 49.6ppmv FID signal TCD signal Page 8

The temperature program and event table had to be modified from the previous ones to run this sample because a 10 minute headspace time had to be included in the analysis. This required holding the initial oven temperature at 50 degrees for 13 minutes instead of 3 minutes as before. Also the Event table was modified to shake ( Relay D ) and heat the 40ml vial ( Relay F) for the first 10 minutes of the analysis. The existing headspace in the vial was also purged for.2 minutes ( Relay E and Relay C ) at the very beginning of the analysis. This may not be necessary or required for real samples which have been inserted into pre-purged vials and remained in the 40 ml vials for some time prior to analysis. As the samples sit in the vial, they are already in the process of equilibrating the headspace so no flushing may be necessary. Notice that to purge the headspace in the vial at time 0.05 minutes, Relay C is turned on first, and off last, so that the purge gas can flush out the headspace and then depressurize through the Relay C solenoid. When the vial is pressurized at 9.8 minutes however Relay C remains off until 9.8 minutes so the headspace gas has a few seconds to homogenize before being released through the loop. Page 9

Revised 2013 Shown at right is the 1% gas mix ( equilibrated into water ) using nitrogen carrier gas and high ( 120ma ) filament current. Nitrogen carrier enables detection of hydrogen in liquids to 5ppm but sacrifices detection of nitrogen. 192ppmv Hydrogen in waterwater TCD signal The FID/Methanizer detects Methane, CO, CO2, ethane, ethylene, and acetylene and other hydrocarbons down to 1ppmv. Page 10