CHECK VALVES FOR CRYOGENIC SERVICE

Similar documents
Self-operated Pressure Regulators for special applications

Valve Inspection & Testing

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Products for Cryogenic Applications

Annex G (normative) Requirements for Nondestructive Examination

KLINGER CONAXE Double Offset High Performance Butterfly Valve DN

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Non-intrusive Natural Gas Flow Measurement

Perform Pressure & Leak Test, Tubing & Piping. Module 12306

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

776 Cryogenic Safety Valve

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Industrial valves Isolating valves for low-temperature applications Part 1: Design, manufacturing and production testing

CONTROL VALVE TESTING

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

Flexible Engineered Solutions International CALM Buoy Swivels

v. Size shall be specified on drawings.

Finding leaks in Main Cryogenic Heat Exchangers without shutdown

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Pibiviesse High Performance Control Ball Valve

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS

On-Stream Tightness Testing of Vacuum Process Installations

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

HYDROSTATIC LEAK TEST PROCEDURE

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

INDUSTRIAL GAS SOLUTIONS. Cryogenic & Non-Cryogenic

SV60 Safety valves. for use with steam, gas and liquids

PIP PNE00012 Piping Examination and Leak Test Guide

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

LEAKAGE ACCEPTANCE RATES COMPARISON METAL & SOFT SEATED VALVES ISO 5208/API 598/API 6D/MSS SP-61/FCI 70-2

FLAME ARRESTOR MODEL L76C-UF

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Trifecta High-Pressure Systems

H&D Fitzgerald Pressure Pyknometry System Mark 5

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Installations & Equipment

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Description Advanced Features Typical Applications

Standard: NFPA 86 Process Ovens and Furnaces. NFPA 85 Boiler and Combustion Systems Hazards Code

756 Safety Relief Valves

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Materials : Carbon steel ASTM A216 WCB

Series 100 Slam Shut Valve. Technical Bulletin

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

CRYOGENIC PRESSURE REGULATOR

ASX 176 Axial Pressure regulator

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Cast iron swing check valve. BS EN 12334:2001 PN16

Loss Prevention Standard

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Vehicle-mounted meters, pump supplied

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Instruction Manual Contact Pressure Vacuum Gauge

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

RULES PUBLICATION NO. 119/P

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

N2 Membrane+ Nitrogen Production Systems for Offshore. Where you are. Where you need to be. We are here too.

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

World Area Differences Technical Information

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

TESTING SAFETY OF HYDROGEN COMPONENTS

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Norval Pressure regulator

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Pressure regulating valves Types OFV, OFV-SS

TECHNICAL DATA. Q = C v P S

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

USE A RELIABLE A INNOVATIVE A COST EFFICIENT GAS EQUIPMENTS AND GAS SYSTEMS

Deltaflux Control Valve

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

CHE Well Testing Package/Service:

TSS21 Sealed Thermostatic Steam Tracer Trap

BRITISH STANDARD BS : Flat-bottomed, vertical, cylindrical storage tanks for low temperature service

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Gases and welding distributors continue

PIPELINE SAFETY. Darin Burk, Manager Pipeline Safety. January 28, 2014

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

TECHNICAL DATA. Q = C v P S

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Pipeline Systems PIP PLSC0019 Specification for Pressure Testing HDPE Plastic Pipeline Systems

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Measurement & Analytics Wet gas monitoring

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

LEAKAGE ACCEPTANCE RATES COMPARISON METAL & SOFT SEATED VALVES ISO 5208/API 598/API 6D/MSS SP-61/FCI 70-2

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

Transcription:

CHECK VALVES FOR CRYOGENIC SERVICE www.checkvalves.co.uk

Performing where it matters Goodwin International is globally approved for its design, manufacture and supply of Dual Plate Check Valves and Non-Slam Axial Check Valves to all aspects of the world s hydrocarbon, energy and process industries upstream, midstream, downstream. With a track record of supply of over 35 years, Goodwin has an enviable reputation for quality and reliability of product at internationally competitive prices. This high quality product is supported by an organisation that has extensive experience, knowledge and skill sets to meet today s stringent end-user specifications and their quality management systems expectations. Based in the United Kingdom, Goodwin sells internationally exporting to over 80 countries and providing its customers with outstanding service and support. Listed amongst its customers are the vast majority of the world s end users, both oil majors and national oil companies, and national and international engineering contractors. A Success Story in LNG Goodwin has 30 years of supply experience into cryogenic and liquid gas applications and has been a major supplier to the world s new build LNG projects over that time. Both its range of Dual Plate Check Valves and Non-Slam Axial Check Valves are utilized in all facets of the LNG industry Liquefaction, LNG ships, receiving terminals, LNG tanks, Regasification. Goodwin has been hugely successful in securing contracts for supply to the world s most prestigious and high value capex LNG export projects as well as many LNG ships and receiving terminal projects. The vast majority of valves are of 316 Stainless Steel constructions for use in Liquefied Natural Gas at a temperature of -161 C. Often these valves are accompanied by a large number of valves of Low Temperature Carbon Steel (LTCS) construction for low temperature service applications and which require low temperature testing. www.checkvalves.co.uk

Check Valve Range for Cryogenic Service Dual Plate & Non-Slam Axial Check Valves Size range: 1 to 72 Pressure Classes: ASME 150-2500 Materials: Stainless Steel, Low Temperature Carbon Steel End Connections: Flanged, Butt Weld End, Hub-end Further information on these 2 types of valve is available on www.checkvalves.co.uk Achievable Seat Leakage Rates A check valve is not a shut-off valve but is the first line of defence it being immediately responsive in the event of an unexpected event producing unwanted reverse flow, e.g. pump failure, pipe rupture. Consequently, in LNG there is invariably a stringency in specification that demands a very high degree of leak tightness across a check valve. With both its check valve types, Goodwin can meet most customers stringent tightness requirements. In its Dual Plate Check Valve, Goodwin has a unique (patented) slim plate design that flexes on to the body seat with back pressure enabling a higher degree of shut-off than is readily achievable by its competitors. Goodwin International is capable of incremental pressure testing at temperatures from room temperature down to -196 C. In its custom built test chamber Goodwin can conduct the safe testing of valves with helium at the full design pressure of the valve (to 20000psig/1380barg) at -196 C. The test procedure is in accordance with Shell International specification SPE 77/200. Valves to be used in cryogenic or low temperature service are prepared and conditioned. Seat leakage is measured with calibrated flow meters. Valve Inspection and Test Standard API 598 defines the maximum permissible leakrate with air or inert gas at ambient temperature conditions as 700cc/minute/NPS. However, for cryogenic service Goodwin manufactures, as standard, both its valves with a maximum leakrate of 450cc/minute/NPS (ISO 5208 Rate E) with Helium at -196 C. Goodwin has selected this maximum leakrate in response to the requirements of today s LNG plant designers. Lower leakage rates can be achieved at additional cost. Acceptance Standards Seat Leakage: ISO 5208 Rate E - 450 cc/min/nps [Note: API 598-700 cc/min/nps] Outside Leakage (body): Zero

Low Temperature & Cryogenic Testing Procedures Whether the valve is to be low temperature tested or cryogenic tested, the test method will be in accordance with *SPE 77/200 (latest revision) or similar procedure e.g. BS6364. The sequence of testing per SPE 77/200 is as follows: Hydrotest at ambient temperature Acceptance standard API 598 Pneumatic test at ambient temperature Acceptance standard ISO 5208 Rate E Cryogenic/Low temperature testing Cryogenic/Low Temperature Testing Coolant Selection: Cryogenic testing at -196 C: Immersion of valve in liquid nitrogen. Low temperature testing -46 C: Immersion in liquid nitrogen vapour. Intermediate temperature testing: Immersion in liquid nitrogen or liquid nitrogen vapour. Temperature Control: Temperature is monitored by the use of thermocouples located both internally and externally of the valve body and internally and externally of the test tank. Once the required valve temperature has been achieved and stabilised the pressure test commences. *SPE 77/200 is the specification of Shell Global Solutions International B.V. for Valves in Low Temperature and Cryogenic Services Selection of leak test medium: Cryogenic i.e. -196 C: pure helium. Low temperature i.e. -46 C: 99% nitrogen/1% helium mix or pure helium. Intermediate temperature: pure helium, or 99% nitrogen/1% helium mix dependent on test temperature. Test Method SPE 77/200: Pressure within the test valve is increased in 4 equal increments and seat leakage is measured using a series of calibrated flowmeters. The maximum pressure at which the valve is tested is limited by the Cold Working Pressure (CWP) as designated in ASME B16.34 for the rating of valve under test. Shell (body) Leakage Test: Following seat leakage test, the valve is removed from the tank and the valve body integrity is tested whereby the body cavity is pressurised and a shell leak detection test carried out using a Helium Mass Spectrometer. The detection limit for acceptance is 5 x 10-4 mbarl/sec, this being defined as zero leakage. Test Reports All observations, data and results shall be recorded in sequence with dates and times into a single Test Report document.

Facilities & Expertise At Goodwin International s cryogenic test facility, cryogenic and low temperature testing is conducted in accordance with Shell s MESC SPE 77/200 specification or like procedure. Goodwin can accommodate most clients testing regimes. With its supply history of some 30 years into LNG and other liquid gas applications, Goodwin has proven experience and expertise in the rigorous testing of cryogenic valves and the meeting of customers specifications and requirements. Features BS EN ISO 9001 registered facility Onsite technical support from qualified engineers Onsite skilled fitters Provision of Test Report certification Facilities Dedicated cryogenic & high pressure gas test chamber On-site bulk liquid nitrogen supply On-site portable PMI (Positive Material Identification) Thermocouple connections State-of-the-art equipment for temperature and time recording and graph plotting Calibrated equipment/regular calibration Helium Mass Spectrometer Drying out/warming furnace Capabilities High pressure gas testing (20000psig/1380barg) Testing down to -196 C Incremental pressure testing Testing to SPE 77/200 (or BS6364 or customer specification) Maximum size: to 2m (80 ) overall dimension Maximum weight: 10,000 kg

CHECK VALVES FOR CRYOGENIC SERVICE FM 00343 EMS 600979 OHS 600980 IMR 613512 Registered Supplier No. 42851 UVDB Registered Supplier No. 206106 Newstead Industrial Estate, Trentham, Stoke-on-Trent, ST4 8HU, England Tel +44 (0)1782 654000 Fax +44 (0)1782 208060 Email checkvalves@goodwingroup.com www.checkvalves.co.uk GIV-067-2000 1v6