Laboratory Standard Operating Procedure: Carcinogens

Similar documents
Laboratory Standard Operating Procedure: Sensitizers

Laboratory Standard Operating Procedure: Reproductive Toxins

Laboratory Standard Operating Procedure: Acutely Toxic Substances

Laboratory Standard Operating Procedure: Irritants

Laboratory Standard Operating Procedure: Specimen Preservatives

Laboratory Standard Operating Procedure: Cryogenic Liquids

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

STANDARD OPERATING PROCEDURE TEMPLATE

STANDARD OPERATING PROCEDURE (SOP): URETHANE

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Laboratory Chemical Hygiene Plan

Standard Operating Procedure (SOP)

Hydrogen Cyanide (HCN)

Standard Operating Procedure

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Hazardous Materials Spill Response

Developing Safety Guidelines for Cryogenic Liquids.

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

13 Listed Carcinogens

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

Hazardous Materials Spill Response

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

1. Substance Information

Standard Operating Procedure for Solvent use in EMAL

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

14 FORTUNE DRIVE PRODUCT NAME: EPO-TEK H74 UNF, Part A BILLERICA, MA 01821

Hydrofluoric Acid SOP

Laboratory Specific Standard Operating Procedures. This SOP must be kept on file for all laboratory employee training and review.

Standard Operating Procedure

The health hazards of HF are dependent upon the concentration, temperature and nature of exposure.

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Yeo Soh Bee A/Prof Dan Yock Young 28/03/2016 Prepared by Approved By Issue Date

Standard Operating Procedure

Standard Operating Procedure (SOP) for (_Hydrpchloric Acid_)

Gulf Compressor Synthetic DE Lubricant

All Multi-Tech Non-Phthalate Color Inks MATERIAL SAFETY DATA SHEET

Product Name:Heat Sink Compound 1801 Morgan Street MSDS Number:148

Material Safety Data Sheet

14 FORTUNE DRIVE PRODUCT NAME: EPO-TEK H20E, Part A BILLERICA, MA 01821

MATERIAL SAFETY DATA SHEET WATER GUARD, INC.

SAFETY DATA SHEET (SDS)

Working Safely with Hydrofluoric Acid

* HMIS CODE ratings are estimated by Epoxy Technology. II. HAZARDOUS INGREDIENTS CAS# WT % TOXICITY DATA

SAFETY DATA SHEETS. This SDS packet was issued with item: N/A

SAFETY DATA SHEET (SDS)

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET (SDS)

SAFETY DATA SHEET INTERNATIONAL FLAVORS & FRAGRANCES

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

Carcinogen: NTP (No) IARC (No) OSHA (No) DATE REVISED: 6/5/01 REV: A * HMIS CODE ratings are estimated by Epoxy Technology.

SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION

14 FORTUNE DRIVE PRODUCT NAME: EPO-TEK OM125, Part A BILLERICA, MA 01821

MATERIAL SAFETY DATA SHEET. COPPER CARE PRODUCT NAME: Aqua-Nap-5. ATTENTION: SAFETY MANAGER MSDS Number: Date of Last Revision: 04/10/2006

MATERIAL SAFETY DATA SHEET M.S.D.S.

Activated Carbon %

MINNESOTA STATE UNIVERSITY MOOHREAD CHEMICAL HYGIENE PLAN

Standard Operating Procedure (SOP) for ( Sodium Hydroxide )

Carcinogen: NTP (No) IARC (No) OSHA (No) DATE REVISED: 11/8/11 REV: E * HMIS CODE ratings are estimated by Epoxy Technology.

SOP Standard Operating Procedure. Etching All Materials

MATERIAL SAFETY DATA SHEET High Pressure Laminate

Laboratory Safety Training. Environmental Health and Safety

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Standard Operating Procedure (SOP)

TESCO Products Inc. Crystal Seal II

Chemical Spill Clean-up Protocol

SECTION 1: Identification of the substance/mixture and of the company/undertaking. SECTION 2: Hazards identification

SECTION I - PRODUCT IDENTIFICATION SECTION II - HAZARDOUS INGREDIENTS & OTHER COMPONENTS SECTION III PHYSICAL DATA / CONTENTS WITHOUT PROPELLENT

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET SDS DATE: 1/15/2016 Sperm Viability Stain

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

While this material has a low level of toxicity, good industrial hygiene practices are encouraged to minimize exposure.

All ingredients are on the TSCA inventory or comply with TSCA requirements

MATERIAL SAFETY DATA SHEET (MSDS) MATERIAL SAFETY DATA SHEET EM SCIENCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Catalog Number(s):

14 FORTUNE DRIVE PRODUCT NAME: EPO-TEK H61LV BILLERICA, MA 01821

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET (MSDS) MATERIAL SAFETY DATA SHEET EM SCIENCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Catalog Number(s):

CSU Channel Islands Chemical Hygiene Plan

Emergency Response Code CODE BROWN HAZARDOUS SPILLS. Purpose & Authority. Definitions

LUSTER SEAL WB 150 Version 3.0 Print Date 07/08/2012 REVISION DATE: 07/07/2012

RILCO INC st STREET ROCK ISLAND, IL PRODUCT NAME: RILCO Tapping Oil 2889 / NFPA CHEMICAL NAME: N/A HAZARD

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS) Critical Care Plus

1. IDENTIFICATION OF THE SUBSTANCE OR PREPARATION AND OF THE COMPANY. Concrete Stain Away. Date: September 1, 2015

MATERIAL SAFETY DATA SHEET. Product Name: Magic Warmer Product Code: MAG4057 Page 1 of 7

Standard Operating Procedure

MATERIAL SAFETY DATA SHEET RPM Wood Finishes Group 3194 Hickory Boulevard Hudson, North Carolina

ZERO VOC URETHANE REDUCER

SAFETY DATA SHEET (SDS)

PRODUCT NAME: AC 303 W/B ACRYLIC EPOXY ENAMEL WTB

EUCON CIA - BULK GALLONS Version 2. Print Date 09/13/2008 REVISION DATE: 09/12/2008

MATERIAL SAFETY DATA SHEET

"LABORATORY SAFETY SERIES"

Quenching of Self-Heating Substances and Mixtures

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS) Kidney Check

CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

LIQUID ICE CORPORATION

Material Safety Data Sheet. 1. Identification of the substance/preparation and of the company/undertaking

Transcription:

I. THIS STANDARD OPERATING PROCEDURE (SOP) IS FOR A: Specific laboratory procedure or experiment Examples: synthesis of chemiluminescent esters, folate functionalization of polymeric micelles, etc. Generic laboratory procedure that covers several chemicals Examples: distillation, chromatography, etc. Generic use of specific chemical or class of chemicals with similar hazards Examples: organic azides, mineral acids, etc. This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with carcinogenic materials. This general use SOP only addresses safety issues specific to carcinogenic hazards of chemicals. In some instances, several general use SOPs may be applicable for a specific chemical (i.e., for benzene, both general use SOPs for flammables and carcinogens would apply). If you have questions concerning the applicability of any item listed in this procedure contact the Principal Investigator/Laboratory, Supervisor of your laboratory or the Chemical Environmental Health and Safety Coordinator [CEHSC] at (813) 842-3528. II. CLASS OF HAZARDOUS CHEMICALS A carcinogen is a substance or agent that meets one of the following criteria: 1. It is regulated by OSHA as a carcinogen. 2. It is listed under the category, "known to be carcinogens" in the Annual Report on Carcinogens published by the National Toxicology Program (NTP s most recent edition); or 3. It is listed under Group 1 ( carcinogenic to humans ) by the International Agency for Research on Cancer (IARC) 4. It is listed in either Group 2A or 2B by IARC or under the category, "reasonably anticipated to be carcinogens" by NTP, and causes statistically significant tumor incidence in experimental animals in accordance with any of the following criteria: a) After inhalation exposure of 6-7 hours per day, 5 days per week, for a significant portion of a lifetime to dosages of less than 10 mg/m3; b) After repeated skin application of less than 300 mg/kg of body weight per week; or c) After oral dosages of less than 50 mg/kg of body weight per day. III. GENERAL HAZARD CONTROL Laboratory specific SOPs will vary according to the material used and detail of experimentation techniques. The following guidelines are to be applied as a general precaution for projects involving carcinogens: 12 April 2013 Page 1 of 6 ut sop carcinogens v1.1

1) Use the smallest amount of chemical that is consistent with the requirements of the work to be performed. 2) Use containment devices (such as lab fume hoods or glove boxes) when: a) Volatilizing these substances, b) Manipulating substances that may generate aerosols, and c) Performing laboratory procedures that may result in uncontrolled release of the substance. 3) Use high efficiency particulate air (HEPA) filters, carbon filters, or scrubber systems with containment devices to protect effluent and vacuum lines, pumps, and the environment whenever feasible. 4) Use ventilated containment to weigh out solid chemicals. Alternatively, the tare method can be used to prevent inhalation of the chemical. While working in a laboratory hood, the chemical is added to a pre-weighed container. The container is then sealed and can be re-weighed outside of the hood. If chemical needs to be added or removed, this manipulation is carried out in the hood. In this manner, all open chemical handling is conducted in the laboratory hood. IV. ENGINEERING & VENTILATION CONTROLS Carcinogenic chemicals should be used in lab fume hoods or a well-ventilated area. When used in larger quantities (> 500mL) or when using above room temperature and/or pressure fume hoods are mandatory. If the process does not permit the handing of large quantities of carcinogens in your fume hood, contact the CEHSC at 813-840-3528 to request ventilation review. Lab ventilation should have a minimum of 6 air changes per hour. NOTE: Certain carcinogens are also considered particularly hazardous substances (i.e., benzene) and may require use of fume hood due to the flammables potential. FOLLOW SAFE FUME HOOD PRACTICES: 1. Ensure the fume hood s certification date is within a one-year period. Verify sufficient inward airflow before using a hood by checking the hood s airflow indicator. Report any problems to PI/Lab Supervisor and the CEHSC. 2. Maintain hood sash at or below the maximum height indicated by an arrow on the side of the fume hood. 3. Close the hood sash when not working in the hood. 12 April 2013 Page 2 of 6 ut sop carcinogens v1.1

4. Avoid rapid movements at the face of the hood to avoid creating competing air currents that reduce the ability of the hood to contain air contaminants. 5. Equipment used in hoods should be placed securely on blocks to allow air to flow under and around the equipment. 6. Keep chemical sources and equipment at least six inches away from the face or rear of the hood. 7. Minimize equipment and chemical storage placed in the hood to avoid dead air spaces or eddies and to prevent blocking back baffles. V. PERSONAL PROTECTIVE EQUIPMENT Lab Coat Long pants Close-toed shoes Safety glasses The above listed personal protective equipment should be worn when handling highly reactive or unstable substances. Additional protection may be required based upon each chemical agent. Check all personal protective equipment [PPE] prior to use to ensure good undamaged condition. At a minimum: 1. When handling hazardous chemicals or contacting potentially contaminated surfaces, protective gloves are to be worn. For proper selection of glove material, review chemical MSDS and glove selection guidance. 2. Goggles (not safety glasses) are appropriate for processes where a splash or spray potential exists. 3. Additional protective clothing (i.e., face shield, apron, and oversleeves) is appropriate for chemicals that are toxic through skin contact or dermal absorption. VI. SPECIAL HANDLING PROCEDURES AND STORAGE REQUIREMENTS Ensure secondary containment and segregation of incompatible chemicals per guidance within the UT Chemical Hygiene Plan. Also, follow any substance-specific storage guidance provided in SDS documentation. 12 April 2013 Page 3 of 6 ut sop carcinogens v1.1

VII. DESIGNATED AREA For use of carcinogens, a designated area shall be established where limited access, special procedures, knowledge, and work skills are required. A designated area can be the entire laboratory, a specific laboratory workbench, or a laboratory hood. Designated areas must be clearly marked with signs that identify the chemical hazard and include an appropriate warning; for example: WARNING! FORMALDEHYDE WORK AREA CARCINOGEN.. VIII. EMERGENCY SPILL AND ACCIDENT PROCEDURES Health-Threatening Emergencies Examples: Fire, explosion, health-threatening hazardous material spill or other Immediate Danger. 1. Call 911 2. Alert people in the vicinity to evacuate 3. Activate the local alarm systems 4. Call Campus Security at 813-257-7777 or xtn. 7777 5. Remain nearby to provide arriving emergency responders information about chemicals 6. Once personal safety is established, call the CEHSC at (813) 842-3528 Personnel Injury or Exposure Non-Health Threatening Emergencies Small Spill Clean-Up 1. Remove the injured/exposed individual from the area if it is safe to do so because of the medical condition of the victim or the potential hazard to rescuers. 2. Call 911 3. Administer first aid as appropriate. 4. Flush contamination from eyes/skin using the nearest emergency eyewash/shower for a minimum of 15 minutes. 5. Remove any contaminated clothing to prevent contaminants from continuing to absorb onto skin. 6. Give medical responders copies of SDSs for all chemicals the victim was exposed to. 7. Report the exposure to the CESHC Call Security at 813-257-7777 or xtn. 7777 to report incident Note: Only minor spills or releases can be cleaned up by knowledgeable personnel using readily available equipment: 1. Notify personnel in the area and restrict access. Eliminate all sources of ignition. 2. Review the SDS for the spilled material, or use your knowledge of the hazards of the material to determine the 12 April 2013 Page 4 of 6 ut sop carcinogens v1.1

appropriate level of protection. 3. Wear gloves and protective eyewear. Clean up using absorbent. Put the contaminated absorbent in a labeled hazardous waste container. 4. If greater than 30 ml, or if it will take longer than 15 minutes for you to clean-up, immediately call Security (813) 257-7777 or xtn. 7777 to report the spill, and notify your supervisor. 5. Submit waste pickup request to the CEHSC. Incident Reporting 1. Report all occupational injuries or illness to laboratory supervisor as soon as practical. 2. Laboratory personnel are encouraged to report "near misses" as they are considered a precursor to actual incidents. 3. Laboratory supervisor is to conduct (or coordinate) an investigation of all incidents and "near misses." The goal of the investigation is to identify and address any deficiencies that may have contributed to the incident. Medical Consultation Laboratory personnel who work with hazardous chemicals are to be provided the opportunity to receive medical attention/consultation when: 1. A spill, leak, explosion or other occurrence results in a hazardous exposure (potential overexposure). 2. Symptoms or signs of exposure to a hazardous chemical develop. IX. WASTE DISPOSAL Carcinogens intended for disposal are considered hazardous wastes. Please call the CEHSC at (813) 842-3528 to Describe the quantities of waste you anticipate generating and appropriate waste disposal procedures. Include any special handling or storage requirements for your waste.. X. DECONTAMINATION PROCEDURES PERSONNEL Immediately after working with carcinogens, remove gloves, wash hands and arms with soap and water. If immediate medical attention is required, call 911. Remove any contaminated clothing, and IMMEDIATELY flush contaminated skin with water for at least 15 minutes following 12 April 2013 Page 5 of 6 ut sop carcinogens v1.1

any skin contact. For eye exposures, IMMEDIATELY flush eyes with water for at least 15 minutes. Consult SDS for guidance on appropriate first aid. Where medical attention is required, ensure to bring along SDS(s) of chemical(s) to aid medical staff in proper diagnosis and treatment. AREA 1. Decontamination procedures vary depending on the material being handled; consult the SDS. 2. Some materials can be neutralized with other reagents. 3. All surfaces should be wiped with the appropriate cleaning agent following dispensing or handling. Note: Waste materials generated should be treated as a hazardous waste. EQUIPMENT Decontaminate laboratory apparatus or other contaminated equipment (glassware) before removing them from the designated area. XI. TRAINING REQUIREMENTS General Training (check all that apply): General Safety & Emergency Preparedness Annual Orientation Training Review of MSDS for other chemicals involved in process/experiment Compressed gas safety Review of this SOP Other: The University may require additional safety training depending on the hazardous materials and laboratory-specific processes consult the PI for more information. 12 April 2013 Page 6 of 6 ut sop carcinogens v1.1