CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

Similar documents
PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Float valves Types SV 4, SV 5 and SV 6

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Pressure Management Solutions

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Air Operated Hydraulic Pumping Systems to 50,000 psi

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

The 700 Series Roll Seal Control Valve is the Best Choice for All Your Special Applications

CASH VALVE TYPE KP BACK PRESSURE VALVES

FILTER BYPASS CONTROL

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

V43 Pressure Actuated Water Regulating Valve

BACK PRESSURE / SUSTAINING

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE

DS06D,G Dial Set Pressure Regulating Valve

Liquid Level Controllers

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

BACK PRESSURE / SUSTAINING

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

SINGLE VALVE WITH LOW-FLOW BYPASS

Rate of Flow Valve Series 120

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

Speed control assembly model A-1

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Pressure Regulator B-95

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Page 1 of 12

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

CLASS TLP Pressure Reducing Valve

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Models 106-RF / 206-RF Rate of Flow Control Valve

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA CAUTION

Choosing the right miniature instrument and control valve is a snap

Technical Data Sheet T 2025

shutoff valves 900 Series psig Manual Shutoff Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MM-701. McDonnell & Miller Replacement Parts Catalog. For Residential, Commercial and Industrial Applications

Pressure Dump Valve Service Kit for Series 2300 Units

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Float valves Types SV 1 and SV 3

Vertical and Horizontal Bladder Tanks

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

D05 Pressure Regulating Valves

North American Simplex Basket Strainers for Gas and Oil

SV5 Safety Valve Installation and Maintenance Instructions

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

D05T Compact Design Pressure Regulating Valves

L21S/SR/ST Glass Level Gauges

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

TW Temperature Control Valve

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

210 & 220 series gas pressure regulators for industrial applications

Avenger Model 33M Installation & Operation Instructions

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Float Operated Level Controllers

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

SECTION BUTTERFLY VALVES

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Service and installation must be performed by a trained/experienced service technician.

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

Pilot valves for pilot operated servo valves

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

C 10 Pressure Reducing Valve

TECHNICAL DATA. Q= Cv S

Industrial Products Catalog Tank Valves

S300 Series. Valve Link. Features. Fisher Controls

DESIGN AND PRE - INSTALLATION INFORMATION

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

CL838 Series Twin Parallel Flow Service Regulators

Noth American 7347 High Pressure Gas Regulators

DS05C,D,G Dial Set Pressure Regulating Valves

Air Amplifiers & SYSTEMS

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Model VR6 System. Installation, Operation & Maintenance

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

ALF400 to 900, ALT-5/-9

Model 141-A Regulators

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

GM Series Dual-Block Multi-Function Gas Control Valves

TECHNICAL DATA. Q = C v P S

Transcription:

MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control The Cla-Val Model Float Control is a float-actuated, multiport pilot control which provides non-modulating, two-position, onoff operation. It is used primarily to operate remotely located Cla- Val Valves requiring three-way or four-way pilot valve operation. Designed for use in closed tanks, this control operates on a minimum level change of approximately one inch. Maximum level change of five and one-half inches is needed for full capacity. Note: We recommend protecting the control tubing and valve from freezing temperatures. Specifications Dimensions (In Inches) Control Piping Connections Reservoir Connections Pressure Rating Temperature Rating 8" NPT " NPT 0-50 psi Water: to 80 F. 7.00 7.3 Materials In contact with operating fluid:, Stainless, Monel, with Seals Float chamber: Cast Pilot valve housing: Bronze Materials in contact with operating fluid:, Stainless, Monel with Seals Float ball: Stainless Float arm: Other material available: Cast steel or aluminum chamber and pilot valve housing. All stainless steel Level Differential Approximately " minimum required to change pilot valve operation. 5 5 6" required to develop full capacity. Operating Fluids Clean liquids or gases compatible with specified materials. Shipping Weight 2 lbs. 3.0 8.75 6.50 Reservoir Connection " NPT (Typ. Both Ends 2 Places) Float Travel 5.32.62 /8" NPT (Typ. 4 Places)

Installation Data The float control is mounted at the high water level in the tank. The remote Cla-Val valve is installed in the line leading to the tank and is connected to the float control pilot by tubing. (Min. 3 8" for valves 6" and smaller, 3 4" or larger for valves 8" or larger.) When line pressure is used to operate the valve, tubing connections are made from the float control pilot to the valve cover, and also to the inlet side of the valve. An X46 Flow Clean Strainer must be installed in the inlet side of the valve. The control may be installed at any elevation above the valve, providing that the flowing line pressure in psi is equal to, or greater than, the vertical distance in feet between the valve and the float control. An independent source of air or water may be used to operate the valve. The pressure from this independent source must constantly be equal to or greater than pressure at the valve inlet. The independent source is connected to the float control pilot in place of the supply line connected to the inlet side of the valve. If the Model 00-0 under the control of the is 8" or larger, auxiliary Hytrol valves may be required. Consult factory for details. Note: We recommend protecting the control tubing and valve from freezing temperatures. For Controlling Hytrol Valve X46 Flow Clean Strainer Flow When Ordering, Please Specify Float Up Closes Valve Float Down Closes Valve. Catalog No. 2. Size and Type of Valve to be Controlled. 3. Materials if different from standard 4. Specify Gravity of Fluid if other than Water. For Controlling Powertrol Valves Float Up Closes Valve Float Up Opens Valve For Controlling Two Valves Simultaneously Operation Valve Valve 2 Float Position Valve Valve 2 UP CLOSED OPEN DOWN OPEN CLOSED Valve Valve 2 E- (R-3/20) CLA-VAL PO Box 325 Newport Beach CA 92659-0325 Phone: 949-722-4800 Fax: 949-548-544 CLA-VAL CANADA 4687 Christie Drive Beamsville, Ontario Canada L0R B4 Phone: 905-563-4963 Fax: 905-563-4040 COPYRIGHT CLA-VAL 20 Printed in USA Specifications subject to change without notice. CLA-VAL EUROPE Chemin dés Mesanges CH-032 Romanel/ Lausanne, Switzerland Phone: 4-2-643-5-55 Fax: 4-2-643-5-50 www.cla-val.com Represented By:

PARTS LIST MODEL Float Chamber Control FLOAT ARM (PIPE NIPPLE) CAP SCREW (8 Required) TOP WATER LEVEL FLOATBALL PILOT and HOUSING ASSEMBLY GASKET BODY Common Parts: Description Float Ball *Gasket Cap Screws 3/8-6 x 7/8 Material Neoprene Cad. Plated CATALOG NO. -A -A2 -A -A -A2 NOTE: SEE OTHER SIDE FOR EXPLODED PILOT AND HOUSING ASSEMBLY. BODY PILOT & HOUSING PIPE NIPPLE ASS Y /4 X 2 Bronze with Bronze with Bronze with with with with with with 67586-9 67586-9 67586-9 67586-9 67586-9

Model PARTS LIST Pilot & Housing Assembly For Float Chamber Control PILOT & HOUSING ASSEMBlIES (BRONZE W/STAINLESS STEEL) C426- FOR -A OR -A2-3 C2035 FOR -A2 OR -B2-3 C249H FOR OR -B2-4 ITEM *2 *3 *4 *5 6 7 *8 9 0 2 DESCRIPTION Machine Screw, Rd. Hd., 6/32 x, 6 Required Distributor for C426- Distributor for C-2035 Distributor for C-249- Gasket Disc Assembly Spring Pin, Lock Stem Assembly O Ring Washer Washer, Thrust Arm, Float Housing Monel - Bronze PILOT & HOUSING ASSEMBlIES (BRONZE W/STAINLESS STEEL) C426- FOR -A OR -A2-3 C2035 FOR -A2 OR -B2-3 C249- FOR OR -B2-4 ITEM *2 *3 *4 *5 6 7 *8 9 0 2 DESCRIPTION Machine Screw, Rd. Hd., 6/32 x, 6 Required Distributor for C-807 Distributor for 32340 Distributor for 30792 Gasket Disc Assembly Spring Pin, Lock Stem Assembly O Ring Washer Washer, Thrust Arm, Float Housing Cad. Plated CLA-VAL P.O. Box 325 Newport Beach, CA 92659-0325 Phone: 949-722-4800 Fax: 949-548-544 E-mail: claval@cla-val.com Website cla-val.com Copyright Cla-Val 202 Printed in USA Specifications subject to change without notice. PL- (R-6/202)