User Manual soft air wds

Similar documents
User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

Dynamic pressure system for pressure relief

Air Plus User Manual

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Instruction Manual for Configura Cushionair Portable Pump

User Guide Antidecubitus systems EURO BASIC

Med Aire Alternating Pressure Pump and Pad System

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Paradise Pump Series Operator s Manual

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

Alternating Pressure / Low Air Loss Mattress System

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

(DynaLaL III) Dynamic True Low Air Loss Mattress Replacement System

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

NIMBUS range. with people in mind

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

TEMPUR-MED OPERATING TABLE MATTRESSES AND POSITIONING PRODUCTS.

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

DYNAMIC COMPRESSION THERAPY

Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

How did we design such a revolutionary alternating pressure mattress system?

MA90 Series Mattresses. MA95 Series Mattresses

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

Use this key to determine which sections of this Product Manual apply to your job.

Instructions for Use. OptiLife Nasal Lab Mask

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Intermittent Pneumatic Compression System

User Manual DIRECTHEALTHCARESERVICES.CO.UK

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

SC505 Sof Care Inflator. Operating Instructions and Service Manual

User Manual. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

MA60 Series. MA60 Alternating Pressure System. MA65 Alternating Pressure On-Demand Low Air Loss System. Owner s Operator and Maintenance Manual

LOGIC RANGE AUTOMATIC PRESSURE

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

Digital Melting Point Apparatus

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

Actively supporting your health.

PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

User manual. ZX trolley.

Domus series. Pressure Redistribution System

INSTRUCTION MANUAL. Gas Salamander

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Continuing Education classes during the month of June will be dedicated to the following topic matter:

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Bath Buddy / Bathmate Instruction Book

Fiber Optic Cable Installation 3 in 1 SLIDE, BLOW, LUBRICATE

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Cobi Positioning Cushions

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

LIFECOMFORT ACTIVE AIR

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: P PORTABLE COMPRESSOR

User Manual. Version 1.2 July 2015 Pg. 1

User manual STARLOCK. Careways International - Innovation Quality Performance

Oxygen concentrators. A user guide.

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTRUCTION MANUAL FOR USE OF BABY WALKER FLOWER

accidents which arise due to non-observance of these instructions and the safety information herein.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

SALISBURY ACTIVE OVERLAY SYSTEM

OptiCare. Optimising patient care

Adult Pressure Care. Star Cushion. High Performance Air Cell Cushions

BMR 2100XL Operating Instructions Page 1 of 13

RAM 4021-DPX Operation Manual

User Manual DIRECTHEALTHCARESERVICES.CO.UK

HI 2314 HI 2315 HI 23151

SAUTER FK Version /2016 GB

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Safety instructions and operating manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Instruction Manual EMA 84 Digital Pressure Gauge

MSA AUER SSR 90 [K60]

UK RBF Bath buddy instruction 16pp 21/9/07 09:07 Page 1. Bath-Buddy / Bathmate Instruction Book

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

12V MINI AIR COMPRESSOR

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

USER GUIDE TO POWER ASSISTED BIKES

D I G I T A L C L A M

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Autom ate d t u r n i n g at yo u r f i n g e r t i ps

Transcription:

User Manual soft air wds Item. No. 110 400-wds soft air cumulus wds Item. No. 110 400-cu-wds Pressure ulcer prevention and treatment-systems Assembly and Operation instructions Health. Safety. Independence.

Index Foreword Page 3 1 Safety Instructions Page 4 2 Product overview soft air wds Page 4 3 Introduction Page 5 4 Explanation of indications and functions Page 5 5 System installation setting up soft air soft air cumulus wds Page 6 6 To set soft air wds soft air cumulus wds Page 7 7 wds-function Page 8 8 CPR-function Page 9 9 Troubleshooting Page 9 10 Cleaning instructions Service Page 10 11 Indications Contra indications Page 11 12 Technical data Page 11

Foreword Dear client! You are now holding the user manual of the soft air wds and soft air cumulus wds therapeutic support systems of ADL GmbH. The soft air wds and soft air cumulus wds systems are systems for Pressure Ulcers prevention and treatment produced by ADL GmbH, Germany. There is a choice of using the system in the static position or alternating pressure. The soft air wds and soft air cumulus wds large cell systems have been developed for pressure ulcer prevention and treatment up to High Risk (Stage 3; EPUAP). With the writing of this user manual the product management of ADL has set itself the goal, to create a good and understandable aid and guidance for the employment of the system. If nevertheless questions remain, please ask your provider for direction and assistance Your 3

1 Safety instructions The system may not be used in presence of open flames, heaters a.o s. Protect the equipment against humidity. Operate it only in dry areas. No combustible gases or liquids may enter into the system. EXPLOSION DANGER! Warning! Note! The compressor is under power, as soon as the power supply plug is put in. Before opening the housing of the compressor please unplug the power plug. Repairs must be performed only by qualified technical personnel. The compressor may only be used for its purpose. In case of damage to the compressor the power supply plug must be unplugged immediately. Damaged power supply cord should be replaced immediately. Only room temperatures of 0-35 C provide assurance to good compressor operation. 2a Product overview soft air wds Quantity Description Article-No. 1 Base with 48 cell fixations 64000121-FO 16 Cells, individually removable 64000028-FO 1 Elastic, breathable, washable polyurethane cover 64000029-FO 2b Product overview soft air cumulus wds Quantity Description Article-No. 1 Base with 48 cell fixations 64000121-FO 16 Cells, individually removable 64000028-FO 1 Elastic, breathable, washable polyurethane cover 110 758 1 Inner cover 110 759 1 Insert mattress 500 704 Quantity Description Article-No. 1 Power unit 110 410-WDS-FO 1 Service manual 999 190 1 User manual 112 001-FO-GB 4

3 Introduction soft air wds is a cover mattress system, meaning there should be an additional mattress on the bed with a thickness of at least 5 cm. soft air cumulus wds is a mattress replacement system, meaning no additional mattress on the bed is required. With the blue button situated in the middle of the front panel you can select between static pressure or alternating pressure. This system is suitable for patients with a body weight of 40 to 130 kg. Please note that these weight indications are applicable for patients in a lying position. Other positions will result in another distribution of weight. The soft air wds and soft air cumulus wds systems are dynamic three chamber pressure relief systems (ABC-System) with a cycle time which can be set between 5 to 20 minutes. 4 Explanation of indications and functions 1 On / off switch 4 5 2 3 4 5 Pressure setting higher lower Cycle time Mode (Static / Alternating) Alarm button 3 2 1 5

5 System installation setting up soft air wds soft air cumulus wds 1. 2. 3. 4. 5. Put the soft air wds on the existing mattress and fix fixation straps to the bed (to the up and down moving parts of the bed). When using the soft air cumulus wds mattress, there is no need to keep the existing mattress on the bed. When not correctly attached to the bed this may lead to bed- and mattress damages. Place the mattress in such a way that the tubing s are located at the foot end of the bed. Before hanging the power unit at the foot end of the bed you have to mount the brackets at the back of the power unit. Slide the brackets from below up in the fixation slot. The power unit can also simply be placed underneath the bed. Please note that the power unit should not be covered in any way, as thermal damage can occur! Connect the tubes to the power unit by connecting the tube connectors. Check with a short pull at the tube if the connector is rightly adjusted. Please check rubber O-rings on regular intervals! Check if the tubes are not bent or clamped between other parts. 6

6 To set soft air wds soft air cumulus wds 1. 2. 3. 4. 5. Put the power supply plug in. Switch on the power unit with the on/off switch 1. The alarm light 5 is blinking and the system will start to be filled with air. The alarm light is put out of circuit when inflation of the mattress is completed. Depending on if it is switched on, an acoustic signal sounds. This can be switched off and on with the alarm button 5. In 40-45 minutes the filling cycle will be completed. The alarm light should be put out of circuit when the patient is laying on the mattress. Below a beforehand set pressure level, the alarm light is blinking again. The most effective pressure level can be set with the pressure setting button. The scale is divided into 8 parts. After switching on the power unit, the pressure is set in the middle part of the scale, around 40 mbar. Pressure can be lowered by repeated pressing on the button down to around 10 mbar. By repeated pressing on the right button a maximum pressure of 80 mbar can be set. It is imperative to check the pre-adjustment with a hand check. Try to move your hand under the knee-joint, the lumbar and neck lordosis in order to check if supporting material is present. When the patient sinks too far in the mattress the so called Hammock-effect occurs. This should be prevented at all times. When switching from alternating pressure to static pressure and vice versa, the mattress pressure should be newly adjusted. Normally pressure in static mode has to be lower than in alternating pressure mode. When pressure is too high there will be a lack of supporting material underneath the lordosis area s of the body. The situation can be improved by deflating the mattress by (repeatedly) pressing the left button. When pressure is too low (hammock effect), (repeatedly) press the right button. Each time when changing pressure level you will have to wait minimum 5 to maximum 20 minutes before checking the contact area again. 7

Hammock effect (is to avoid) High extended pressure in the sacral area Optimum surface (Supporting material under the knee-point and lordosis of neck and lumbar) 7 wds-function 8 In case of a contra indication for alternating pressure according to the indications overview, the system can be switched from alternating pressure to static pressure with the wds switch at the power unit. Adjustment to maximum comfort in this mode can be achieved the same way as before. As in static mode all cells are active, it is necessary to reduce the set pressure with about 10 20 mbar (1 2 steps on the scale). To switch over to static function, press button 4. The light will change from blue to green (Static). To switch over to alternating pressure press button from green to blue (Alternate). again. The light will change Don t forget to increase the pressure when switching over to alternating pressure. 4

8 CPR-function The CPR strap is located at the top right site of the mattress indicated with a red tag. In an emergency situation the mattress is quickly deflated by pulling the CPR tag. Within 30 60 seconds the patient will sink to the stable part of the mattress. 9 Troubleshooting Problem Cause Solution Mattress does not inflate Connectors are not Check connection or inflates insufficiently. accurately locked. and position of the tubes. Tubes are twisted or kinked. Exchange possible Defect cell. defect cell. The unit does not operate No power available. Check plug and (blue light at power switch Plug defect, power cord partition socket. is not illuminated). defect, safety fuse defect. Check the safety fuse at the location where the power cord enters the unit. Red alarm light is Connectors not accurately Check connectors, blinking and acoustic locked. Air cell defect. cells and tubing. signals sounds. Tubing defect. Check CPR valve. Exchange possible defect cell. The patient sinks too deep Air cell defect. Check cells and tubing into the mattress. Tubing defect. connections. Check pressure Pressure not correctly set. setting. Exchange possible defect cell. 9

10 Cleaning instructions Service During use the mattress and tubes should be cleaned weekly using a damp soft cloth and mild detergent or non-phenol germicidal solution. Never use any detergents containing aldehyde! After changing to another patient the mattress should be disinfected by an accredited company approved by the Robert-Koch-Institute. Please ensure conformity to the European guideline for medical devices, directions for preparation of medicine products and directions for hospital hygiene and prevention of infections from the Robert-Koch-Institute or other guidelines they rule. The PU cover can be washed to a maximum temperature of 95 C and be re-used after a thermal process (e.g. Ottalin - Peracet - process). Also a steam sterilisation process can be applied. The power unit should be cleaned with a damp cloth and soap detergent or a mild non-aldehyde cleaning detergent. Disinfection with cleaning on location is also possible, when instructions for use and process time are properly kept. ADL GmbH prescribes a safety-check of all electric powered parts after at least 2 years. The rules for accident prevention BGV A2 will remain unaffected. The safety-check may only be conducted by especially trained personal. Disinfectant recommendations: BACILLOCID RASANT (BODE), BACILLOL AF (BODE), BACILLOCID SPEZIAL (BODE), KOHRSOLIN FF (BODE), KOHRSOLIN (BODE), MICROBAC FORTE (BODE), DISMOZON PUR (BODE), INCIDIN FOAM (ECOLAB), INDUR DES (ECOLAB).! Check with your supplier the disinfectant does not damage plastic surfaces (PUR, PA, ABS, PVC). Prevent contact on electrical components with damp or moisture. Cleaning cloths should be damp, not wet. Carefully check no moisture remains in the system. Execute a functions control procedure before using the system again. Check your cleaning process on effectiveness on a regular basis. 10

11 Indications Contra indications Indications Contra indications Alternating Pressure ulcers up to Spastics, situation according to pressure high risk (Stage 3; EPUAP). Apoplex. Pain patients, Large surface wounds. patients with osteoporosis, Plastic surgery. neurological patients. Static pressure Pressure ulcers up to high risk (Stage 3; EPUAP). Large surface wounds. Plastic surgery. Spastics, situation according to Apoplex, pain patients, e.g. patients with osteoporosis. Neurological patients. 12 Technical data soft air wds soft air cumulus power unit Material PU-nylon PU-nylon ABS Dimensions (cm) 200 x 86,5 x 13,5 200 x 86,5 x 18,5 23 x 15 x 8,5 Weight (kg) 5,9 6,9 1,5 Warranty* 2 years 2 years 2 years Electr. connections - - 230 V/7 W Protection class - - Protection class II Fuse - - 230 V/F500mA (slow) Cover Polyurethane, washable to 95 C, can be used in dryer (to 50 C) Application Pressure Ulcer prevention and treatment up to high risk (Stage 3; EPUAP), patient weights between 40-130 kg. * Warranty only valid in case of production or material failures. 11

In case of technical problems please contact your appointed dealer or direct ADL GmbH. (Dealer stamp) ADL Medical International Edisonstraat 6 5051 DS Goirle The Netherlands Phone: + 31 (0)13 5772 088 Fax: + 31 (0)13 5772 648 Email: info@adlmedical.nl Internet: www.adlmedical.nl ADL GmbH Lise-Meitner-Straße 3 48161 Muenster Germany Telephone: + 49 (0)25 34 6224-0 Telefax: + 49 (0)25 34 64270 ADL GmbH Produktionsstaette und Servicecenter Erfurt Thoereyer Straße 1 99334 Ichtershausen Germany Telephone: + 49 (0)3 62 02 7519-0 Telefax: + 49 (0)3 62 02 75 19-12 Copyright by ADL GmbH Muenster Version 06/2011 Email: Internet: info@adl-gmbh.de www.adl-gmbh.de