Swift LT NASAL PILLOWS SYSTEM. User Guide English

Similar documents
Mirage Micro. User Guide. English. nasal mask

Mirage FX. User Guide. English NASAL MASK

Mirage Vista Nasal Mask

English USER GUIDE User guide

Mirage Micro. User Guide. English. nasal mask

Mirage Micro for Kids. nasal mask

English. ivolve Full Face Mask. User Manual

English USER GUIDE User guide

Mirage FX. User Guide. English NASAL MASK

Mirage Quattro FULL FACE MASK

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Mirage Quattro FULL FACE MASK

Mirage Liberty. User Guide 61850/ APAC ENG MIRAGE LIBERTY USER r2 cover.qxp 3/04/2007 4:39 PM Page 1. English FULL FACE MASK

Mirage FX. User Guide. English NASAL MASK

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Mirage FX. User Guide. English NASAL MASK

Instructions for Use. OptiLife Nasal Lab Mask

Mirage Micro for Kids

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

User guide English r1 Quattro Air Amer Multi Multi Book.indb 1 14/07/ :30:10 AM

User Guide. English. Nasal Pillows System

Invacare Twilight II Nasal Mask

User Guide. English. Nasal Pillows System

Quattro FX Quattro FX for Her

AirFit Nasal Mask. User guide N10. English

Fitting / Mise en place / Colocación / Ajuste

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

AirFit Nasal Mask. User guide N10. English

Quattro Air Non-vented full face mask

Pixi. User Guide. Pixi TM PEDIATRIC MASK. English. pediatric MASK

Fitting / Mise en place / Colocación / Ajuste

Swift FX Nano Swift FX Nano for Her

ComfortGel Full. Full Face Mask

Mirage Activa LT. User Guide. English. nasal mask

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR NASAL PILLOWS SYSTEM

Quattro FX Quattro FX for Her

Swift FX Nano Swift FX Nano for Her

Hospital masks. User guide. English

User guide English book.indb 1 14/07/ :51:19 AM

EasyFit SilkGel Full Face Mask

Nasal mask. User guide. User guide English

English Please read the entire Information and Welcome Guides before using your device.

Full face mask. User guide English

English Please read the entire Information and Welcome Guides before using your device.

EasyFit Full Face Mask, Silicone EasyFit Full Face Mask, Gel

Full face mask. User guide. English

S8 Series II. S8 AutoSet Spirit II S8 AutoScore II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICES

Please read the entire Information and Welcome Guides before using your device.

S8 Lightweight II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICE

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Read Instructions carefully before use. Rollator is designed for indoor & outdoor use. Do NOT use as a wheelchair or as a transport chair.

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Full face mask. User guide. English

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

SASK-A-POLE OWNERS AND USERS MANUAL

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

User guide User guide English

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

SOTR Special Operations Tactical Respirator

Portable Massage Table User Manual

Oxygen Dialflow Meter. Instructions for Use

Rev. B. Operating Instructions

Micro Dial-Flowmeter. Instructions for Use

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

ATEX ATEX

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Oxygen Dialflow Meter. Instructions for Use

VPAP IV VPAP IV ST. User Guide. English. Positive Airway pressure device

Mirage Kidsta Nasal Mask

Dialflow Regulator. Instructions for Use

Model 1700 Patient Operating Instructions. Model 1700

Pressure Regulator. Instructions for Use

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

ROPV R40 E Series User Manual

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Contents Warnings, Cautions, and Notes Contents of the Package Introduction to the Harmony S/T A Tour of the Harmony S/T...

Copyright Trek Bicycle Corporation 2005 All rights reserved

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

U S E R M A N U A L. (CGA 870 Connection)

USER S MANUAL. Reorder number: /

S8 AutoScore II System User Guide. English

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Vessel Installation and Operating Manual

TactAir PCP Fill Kit/Adapter. Operation Manual

Owner s Manual. Model H4685

This mask changes everything

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Full face benefits in a compact size

User guide User guide English

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

Thank you for choosing Xuma.

Pressure Injection Cell Operator s Manual

Transcription:

Swift LT NASAL PILLOWS SYSTEM User Guide English

Swift LT NASAL PILLOWS SYSTEM Thank you for choosing the Swift LT. Intended Use Rx Only The Swift LT channels airflow noninvasively to a patient from a positive airway pressure device such as a continuous positive airway pressure (CPAP) or bilevel system. The Swift LT is: to be used by adult patients (> 66 lb/30 kg) for whom positive airway pressure has been prescribed intended for single-patient re-use in the home environment and multipatient re-use in the hospital/institutional environment. English Using the Swift LT When using the Swift LT with ResMed flow generators that have mask setting options, if available select SWIFT ; otherwise select MIRAGE as the mask option. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative Notes: The Swift LT is not compatible for use with ResMed AutoSet CS 2 and VPAP Adapt SV devices. SmartStop may not operate effectively when using Swift LT with some flow generators that have this feature. If you experience nasal dryness or irritation, use of a humidifier is recommended. 1

Parts of the Swift LT & Ordering Information Plastic tube retainer 60586 Top buckle 60579 (1) 60580 (10) Back buckle 60558 (1) 60559 (10) Frame 60575 Headgear assembly 60578 Elbow Pillows 60571 (S*) 60572 (M*) 60573 (L*) Short tube assembly 60577 Velcro tube retainer (sold separately) 60557 Swivel Complete system 60560 (includes small, medium and large pillows) Frame system (pillows, frame, short tube assembly) S* 60582; M* 60583; L* 60584. Frame assembly (frame, short tube assembly) 60581 S* Small; M* Medium; L* Large. 2

Fitting your Swift LT B English A 1 2 3 (A) Hold the pillows at your nose; (B) pull the headgear over your head. Adjust top straps (overtightening may cause excess pressure on your nose). Adjust each end of the backstrap (overtightening may cause excess pressure on upper lip). 4 5 6 Rotate frame to adjust pillow angle to ensure it sits comfortably. Connect the short tube to the flow generator s air tubing. Using the Plastic Tube Retainer (Optional) The Swift LT is now fitted and ready for use. Headgear should sit midway between ear and eye. Swift LT 1 Push tube retainer into buckle. Clip either short tube or air tubing to tube retainer. 2 3 When using the tube retainer, the tubing can be positioned to either side of your face or centered. 3 If the mask pulls on your nose, increase length of tube between mask and tube retainer.

Disassembling your Swift LT Swift LT 1 Detach air tubing from short tube. 2 Remove headgear from frame. 3 4 Remove pillows from frame. Remove elbow from frame. Cleaning your Swift LT in the home Notes: The nasal pillows system and headgear should be cleaned by handwashing. The headgear may be washed without being disassembled. WARNING Do not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol or products that smell strongly (eg, citrus) to clean any of the system s components. Residual vapours from these solutions can be inhaled if not rinsed thoroughly. They may also damage the system, causing cracks. 4

CAUTION If any visible deterioration of a system component is apparent (cracking, crazing, tears etc.), the component should be discarded and replaced. English Daily/After Each Use Handwash the separated mask components (excluding headgear) by gently rubbing in warm (approx. 86 F/30 C) water using mild soap for one minute. Rinse all components well with drinking quality water and allow them to air dry out of direct sunlight. Weekly Handwash the headgear and tube retainer in warm (approx. 86 F/30 C) water using mild soap. Rinse well and allow them to air dry out of direct sunlight. Reprocessing your Swift LT between Patients The Nasal Pillows System should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, www.resmed.com/masks/sterilization/americas. If you do not have Internet access, please contact your ResMed representative. Storage Ensure that your Swift LT is thoroughly clean and dry before storing it for any length of time. Store the mask in a cool dry place out of direct sunlight. Disposal The Swift LT does not contain any hazardous substances and may be disposed of with your normal household refuse. 5

Reassembling your Swift LT 1 2 3 Insert elbow into frame. Align pillows with frame. Push pillows firmly into frame. Ensure top and bottom retention tabs slot into place. 4 5 Check positioning markers on pillows and headgear are on the same side. Reassembling the headgear Slide left and right headgear stability arms onto frame. Ensure inner wall of pillows is in correct position. If not, squeeze pillow sides to release inner walls. A Swift LT A Lay out the headgear as shown, writing facing upwards. B (A) Thread the top straps through the top buckle, then (B) back over to secure. 6 B (A) Thread both backstraps through the back buckle (Velcro facing outwards), then (B) fold back over to secure.

Troubleshooting Possible reason Solution Pillows won t seal properly, are uncomfortable or cause red marks Pillows may have been fitted incorrectly, incorrectly adjusted, or the headgear is too tight. Inner wall position of one/ both pillows is incorrect. Pillows are wrong size. Pillows may be dirty. Nasal pillows system is too noisy System is assembled incorrectly. Before using your Swift LT Carefully follow instructions in Fitting your Swift LT. Check headgear is not over-tightened. Check ResMed logo on top of pillows is facing outwards. Squeeze pillow sides to release inner wall. The correct position in shown in Reassembling your Swift LT. Talk to your clinician. Clean pillows according to instructions in Cleaning your Swift LT in the Home. Reassemble the Swift LT. Make sure the pillows are fully inserted into the frame. English WARNINGS The vent holes must be kept clear. The mask should not be used unless the CPAP system is turned on and operating properly. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the flow generator is not operating, so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire. At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate. The technical specifications of the mask are provided for your clinician to check that they are compatible with the flow generator. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the flow generator function. Discontinue using the Swift LT if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist. As with all masks, some rebreathing may occur at low CPAP pressures. Refer to your flow generator manual for details on settings and operational information. Remove all packaging before using the mask. 7

Technical specifications Note: The mask system does not contain latex, PVC or DEHP materials. Pressure Flow Curve Note: The mask contains passive venting that meets the requirements for protection against rebreathing as specified in ISO 17510-2. As a result of manufacturing variations, the vent flow rate may vary. Vent Flow Rate (L/min) 60 50 40 30 20 10 0 4 6 8 10 12 14 16 18 20 Mask Pressure (cm H 2 O) Pressure (cm H 2 O) 4 20 8 29 12 37 16 43 20 49 Flow (L/min) Dead Space Information Standards Therapy Pressure Resistance Sound Environmental Conditions Gross Dimensions Physical dead space is the empty volume of the mask to the end of the swivel. Using the large cushions this is 94 ml. CE designation in accordance with EC directive 93/42/EEC, class IIa. ISO 14971, ISO 13485, ISO 10993-1 and ISO 17510-2. 4 to 20 cm H 2 O. Drop in pressure measured (nominal) at 50 L/min: 0.6 cm H 2 O and at 100 L/min: 2.0 cm H 2 O. DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with ISO 4871. The A-weighted sound power level of the mask is 25 dba, with uncertainty 3 dba. The A-weighted sound pressure level of the mask at a distance of 1 m is 17 dba, with uncertainty 3 dba. Operating temperature: +41 F to 104 F (+5 C to +40 C) Operating humidity: 15% 95% non-condensing Storage and transport temperature: -4 F to 140 F (-20 C to +60 C) Storage and transport humidity: up to 95% non-condensing. 380 mm (H) x 57 mm (W) x 62 mm (D). Mask fully assembled with short tube assembly no headgear. Note: The manufacturer reserves the right to change these specifications without notice. 8

Symbols Caution, consult accompanying documents; LOT Lot number; REF Part number; Temperature limitation; Humidity limitation; Does not contain latex; Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device. English Limited warranty ResMed Ltd (hereafter ResMed ) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke. Warranty is void on product sold, or resold, outside the region of original purchase. Warranty claims on defective product must be made by the initial consumer at the point of purchase. This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office. 9

Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia See www.resmed.com for other ResMed locations worldwide. Swift LT Nasal Pillows System Protected by patents: AU 785376, DE 20321468.4, DE 20321469.2, DE 20321470.6, DE 20321471.4, DE 20321472.2, EP 1314445, JP 4354664, NZ 562417, NZ 562418, NZ 562419, NZ 553756, NZ 553757, NZ 553822, NZ 553824, NZ 553825, US 6581594, US 6823865, US 6907882, US 7159587, US 7318437, US 7341060. Other patents pending. Protected by design registrations: AU 301943, AU 322986, AU 322987, AU 322988, AU 322989, AU 322990, AU 322991, AU 322992, AU 322993, AU 323065, AU 323066, AU 323067, AU 323068, AU 323069, AU 323070, AU 323071, CN 200430102469.3, CN 200830141233.9, CN 200830141234.3, CN 200830141238.1, CN 200830141239.6, CN 200830141242.8, CN 200830141243.2, CN 200830141244.7, EP 966064, JP 1243026, JP 1349550, JP 1351018, JP 1351019, JP 1351020, JP 1351021, JP 1351022, JP 1351023, JP 1351024, JP 1358420, JP 1363098, JP 1363099, JP 1363100, NZ 407161, NZ 411008, NZ 412497, NZ 412498, NZ 412499, NZ 412500, NZ 412501, NZ 412502, NZ 412503, NZ 412504, NZ 412505, NZ 412506US D552731. Others designs pending. Swift, AutoSet CS and VPAP are trademarks of ResMed Ltd and are registered in U.S. Patent and Trademark Office. Velcro is a registered trademark of Velcro Industries B.V. 2017 ResMed Ltd.

1 2 3 4 5 608299/2 17 09 SWIFT LT USER AMER ML 6 0 8 2 9 9 Global leaders in sleep and respiratory medicine www.resmed.com