THERMAL MASS FLOW MEASUREMENT FOR GASES

Similar documents
analytical bulk flow distance FLOW level pressure temperature industrial communication

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Make the Wise Choice. Choose Sage Flow Meters.

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Thermatel Model TA2 Mass Flow Transmitter

780S Ultra High Purity Series

Make the Wise Choice. Choose Sage Flow Meters.

Flow metering in gases Introduction to COMBIMASS family

Ultra High Purity Model 780S

Design Features. General Description

User Manual For Sage Prism Models SID and SCD Portable Battery Operated Datalogging Gas Flow Meters

Features. Description

For Multi-Parameter Meters see mvx

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Steel-Mass Model 640S

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Online data sheet FLOWSIC30 GAS FLOW METERS

For Multi-Parameter Meters see mvx

Model EXAxt AV550G. Averaging Oxygen Analyzer

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

RCD - Ultra-Rugged Differential Pressure Flowmeter

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Micro Motion 3098 Gas Specific Gravity Meter

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

9700 Transmitter Submersible hydrostatic level transmitter

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Mass Flow Controllers

Model FT4X Thermal Mass Flow Meter & Temperature Transmitter

UNDERSTANDING, ACCELERATED

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

C-Flow Coriolis Mass Flow Meters

deltaflowc deltaflowc Venturi or Probe

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

AMT-Ex Dewpoint Transmitter

Turbine Flowmeters for Gas Applications

How to specify a product. Process Sensors and Mechanical Instruments

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

MODEL WEIGH MODULE

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Over 20,000 Strain Gage Target flowmeters installed since 1952.

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Electronic Volume Correctors

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Installing a Probe. Typical Installation

Steel-Mass Model 640S

Application Note AN-107

CANADA SENSORS TECHNOLOGY INC.

Autocalibration Systems For In Situ Oxygen Analyzers

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Thermal Mass Flowmeters. 5 Mass Flowmeters

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Torque Tube TB300 Digital Transmitters

DTG - LCD Digital Temperature Gauge USER MANUAL

Oxygen & Binary Gas Measurement and Analysis

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Porter Analytical & Industrial Products

Differential Pressure Transmiter

The Ins and Outs of I/P Transducers

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Vortex Meters for Liquids, Gas, and Steam

Turbine Flowmeters for Gas Applications

Improve Process Reliability

Technical Manual. Liquid Level Transmitter CT801-LB/S

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Best Practice Guide, Servomex 2700

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

3.0 Pressure Transmitter Selection

Viatran s Sanitary Pressure and Level Measurement Family

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Autocalibration Systems for In Situ Oxygen Analyzers

L3 Pressure and Level transmitter

Technical Explanation

THERMATEL Enhanced Model TA2

Transcription:

THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters.

A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure the flow rate and consumption of gases for multiple industrial applications. Frequently used for energy management systems to monitor and improve energy efficiency as well as for regulatory compliance in environmental systems including reporting of Greenhouse Gas Emissions. TYPICAL APPLICATIONS include measurement and sub-metering of natural gas and compressed air for energy utilization and cost accounting within a facility. Measurement of combustion air flow can be used for improving efficiency in boilers and furnaces. Environmental reporting of Greenhouse Gases from combustion sources as well as measurement for carbon credits are frequently encountered. OTHER KEY environmental applications include flare gas flow measurement in the Oil and Gas Industry where thermal technology offers economic advantages over traditional flow measurement technology. To meet the regulatory requirements of periodic re-calibration or calibration verification, Sage Metering has developed a unique in-situ accuracy verification process to ensure the meter is performing within the original NIST traceable gas calibration while the process remains in operation. Sage Meters are used for all types of applications: ENERGY MANAGEMENT n Natural Gas Measurement n Compressed Air Flows ENVIRONMENTAL n Green House Gas Emissions n Carbon Credits PROCESS n Flare n Biogas / Landfill Gas n Combustion Air n Vent Air FACILITIES MANAGEMENT n Natural Gas Sub-metering n Department Cost Allocation {2} SAGE METERING, INC.

Experience and Expertise SAGE METERING, INC. is the fastest growing thermal mass flow meter manufacturer in the industry. Founded in 2002, Sage brings together individuals with many years of combined experience in the design, operation, and application of thermal mass flow meters. This vast knowledge has enabled Sage to identify and improve on the overall design and performance of Thermal Mass Flow instrumentation. Sage s philosophy is inherent throughout its product line and services. n Innovative Products n On Time Delivery n Extraordinary Customer Service n Strong Commitment to Quality n Excellent Responsiveness to Customers Make the Wise Choice. Choose Sage Flow Meters. A Pioneer in Technology Development SAGE METERING has brought to market the first digitally-driven circuit design, eliminating the traditional analog Wheatstone bridge. This feature has provided Sage products with the ability to: n Eliminate analog drift, improving stability and long term reproducibility n Show a reproducible zero flow point, permitting simple and reliable calibration verification n Maintain higher resolution providing greater rangeability n Digitally-driven temperature sensor eliminates self-heating errors n Match overheat to application for greater signal resolution n Remote Style: up to 1000 ft. from probe, and lead-length compensated (junction box has no circuitry suitable for harsh environments) IN-SITU CALIBRATION VERIFICATION n User can easily verify that flow meter remains in calibration with simple field test while process is in operation n Checks overall instrument performance both sensor and electronics n Eliminates the need for periodic factory re-calibration n Meets regulatory requirements for calibration check FIRST GRAPHIC DISPLAY IN THERMAL INDUSTRY n Provides flow rate, temperature, totalized flow, diagnostics, and signal at a single glance n High contrast display adjusts to ambient lighting, making it easy to read IMPROVED TEMPERATURE COMPENSATION n Ensure accurate flow measurement over wide range of process temperatures ATTENTION TO ACCURACY n Calibrations performed on actual gas n NIST traceable calibration facility provides accuracy flexibility Compact Design WINNER Flow Control Magazine 2012 Innovation Awards WINNER Flow Control Magazine 2011 Innovation Awards WINNER Flow Control Magazine 2006 Innovation Awards WINNER SAGE METERING, INC. {3}

Sage Prime Thermal Mass Flow Meter (SIP Series) The Prime is Sage s premier Thermal Mass Flow Meter for all rugged industrial applications. The Prime has been approved for use in hazardous areas by many agencies, plus CE rated for Electromagnetic compatibility. Available in both 24 VDC (12 VDC optional) and 115/230 VAC input power. The 2.5 watts power is the lowest consumption in the industry. Easy access to wiring connections Easy-to-read graphic display gives flow rate, totalized flow, temperature and diagnostics information Compact design simplifies installation Available with Integral (SIP) or Remote (SRP) electronics (cable lengths to 1000 ft.) Insertion Probe (shown with optional mounting hardware SVA05) Process temperatures to 450 F (232 C) with standard sensor 1/4 to 4 flow body with flow conditioner (NPT standard, flange optional) Outputs: n 4 20 ma n Optional HART communication n Pulse n Modbus Hazardous area approvals In-situ calibration check verifies proper operation of flow meter Multiple independent calibrations available (field configurable with Addresser software) For more information on the Sage Prime (above), view the Sage SIP Flyer and Data Sheet by visiting www.sagemetering.com/prime. For more information on the Sage Prism (below), view the Sage SID Flyer and Data Sheet by visiting www.sagemetering.com/prism. Or contact Sage at 866-677-SAGE (7243). Sage Prism Portable Datalogging Flow Meter (SID Series) Logs up to 3800 points (flow rate, temperature, time stamps, etc.) Portability with 10 hours of rechargeable battery operation Furnished with carrying case and software Calibrated for three different gases or flow ranges Uploads to Excel format for storage and analysis Prism display detail {4} SAGE METERING, INC.

Sage Rio Thermal Mass Flow Meter (SIX Series) The Sage Rio Thermal Mass Flow Meter provides the same levels of performance found in the Sage Prime with the added ATEX Flameproof approvals. ATEX Flameproof approval II 2G Ex d IIB+H2 T6 Gb* Available with Integral (SIX) electronics. Remote style (SRX) optionally available 1/4 to 4 flow body with flow conditioner (NPT standard, flange optional) Rotatable graphic display gives flow rate, totalized flow, temperature and diagnostics information Outputs: n 4 20 ma n Optional HART communication n Pulse n Modbus In-situ calibration check verifies proper operation of flow meter *T6 Rating is suitable for gases with ignition temperature as low as 185 F (85 C) Insertion Probe (shown with optional flange mounting) For more information on the Sage SIX (above), view the Sage SIX Flyer and Data Sheet by visiting www.sagemetering.com/rio. For more information on the Sage Clear (below), view the Sage SIA Flyer and Data Sheet by visiting www.sagemetering.com/clear. Or contact Sage at 866-677-SAGE (7243). Sage Clear Thermal Mass Flow Meter (SIA Series) The Sage Clear Thermal Gas Mass Flow Meter provides the user with the high level of performance found in the Sage Prime while offering an economic solution for applications where hazardous area approvals are not required. High contrast graphic display shows flow rate, temperature, totalized flow and signal value 4 20 ma signal Reconfigurable software available Pulse output Input power of 24 VDC or 115/230 VAC power Compact, powerful electronics in a NEMA 4 enclosure for indoor/outdoor installations Flow bodies include flow conditioning In-Line Flow Body Available with Integral or Remote electronics (cable lengths up to 1000 ft.) Flow body for 1/4" to 4" pipe or 1/2" insertion probe Please refer to Application Data Sheet for sizing details and model number on any of the products shown on pages 4 and 5 by visiting www.sagemetering.com/applicationsdata. SAGE METERING, INC. { 5 }

5 to 25 diameters typical Flow Conditioning Any insertion flow meter measures the flow at the location of the sensor. Therefore the overall accuracy of the flow measurement is dependent on the flow profile in the pipe. With sufficient amount of straight pipe run, the desired flow profile naturally occurs. Sage recommends straight run distances which are dependent upon upstream and downstream pipe configuration. These recommended distances provide the expected flow profile at the sensor. Often the desired amount of straight run is not available. In these situations, Sage Metering offers flow conditioning assemblies. They are easily installed between two flanges as shown to the right. When using a flow conditioning assembly, the recommended straight run is greatly reduced. The use of a flow conditioner is a very 4" PIPE simple SHOWNmethod for obtaining the best possible overall accuracy. The same installation guidelines should be followed when using a Sage in-line flow body. Flow bodies, however, incorporate a built-in flow conditioning assembly, therefore reducing the straight run requirements. 15 to 25 diameters typical Typical Sage Flow Meter Installation Following a Single 90 Elbow without Sage Flow Conditioning Installed Sage Flow Conditioner Assembly (Self Heated) Typical Sage Thermal Mass Flow Meter Installation with Flow Conditioner Assembly TEMPERATURE (Self Heated) 15 to 25 diameters typical TEMPERATURE 15 to 25 diameters typical Customer Existing Pipe SAGE 3 pipe diameters 1 pipe dia. 1 pipe dia. Customer Existing Pipe SAGE Customer Existing Pipe SAGE (Self Heate TEMPERAT Compress Isolat 3/4" NPT co Threadolet SAGE o COND ASSE (All 3 meters 1 pipe dia. Installation Hardware The Sage Flow Meter with insertion probe can easily be installed into a pipe or duct by using a 1/2" or 3/4" NPT connection. The two most common methods of installation are the 3/4" isolation valve with a compression fitting or the simple ½" compression fitting. The SAGE compression fittings have Teflon ferrules which provide ease in installation and positioning the 1 pipe dia. sensor. The use of the isolation valve permits the probe to be removed while the process is in operation. Flange connections can also be provided to meet user s piping requirements. SAGE 3 pipe diameters 1 pipe dia. 1 pipe dia. Isolation Valve Safety and ChainFitting Model Number SVA05 Compression Fitting Isolation Valve 3/4" NPT connection: Safety Chain Compression Fitting Isolation Valve 3/4" NPT connection: Compression Fitting Model Number STCF05 1/2" NPT connection: 1/2" NPT connection: {6} SAGE METERING, INC.

Principle of Operation Sage Thermal Mass Flow Meters measure heat transfer as the gas flows past a heated surface. The two RTD sensors are constructed from reference grade platinum windings. The RTDs are clad in a protective 316SS sheath and driven by a proprietary sensor drive circuit. The flow sensor is self-heated; the second (temperature) sensor measures the gas temperature. As gas Sage Thermal Mass Flow flows by the flow Technology Uses Dual sensor the gas Temperature Sensors molecules carry to Measure Flow Rate heat away from the surface of the heated sensor. The sensor drive circuit replenishes the lost energy by heating the flow sensor until it reaches the desired temperature TEMPERATURE difference above the reference sensor. The electrical power required to maintain a constant temperature (Self Heated) differential is proportional to the mass flow rate. Sage s proprietary sensor drive circuit maintains the constant temperature difference over the entire operating temperature range of the instrument. The circuit responds quickly to changes in process flow rate or gas temperature. The inherently non-linear signal provides excellent low flow sensitivity and high turndown capabilities. The signal is linearized to provide the output signal from the flow meter. Calibration Calibration is an essential portion of any thermal mass flow meter. The calibration establishes the relationship between mass flow and the power required to maintain the specified temperature difference. For best accuracy, calibrations are performed on the actual gas in Sage s NIST traceable calibration facility. Calibrations are performed to match customer s exact application requirements rather than using standard calibration ranges provided by other manufacturers. In-Situ Calibration Verification One of the challenges with any thermal mass flow meter is to check the instrument s calibration. Verification is possible if just one of the calibration data points can be checked during normal operation. Sage has developed a unique method which permits the user to verify calibration of the flow meter without having to shut down or remove the sensor from the process. This in-situ process is accomplished in three easy steps Loosen, Lift, and Look (see below). This permits the user to STEP 1 LOOSEN Simply Loosen the Valve Assembly s Lower Collar Clamp and Slightly Loosen Its Compression Fitting Lower Collar Clamp Compression Fitting Valve Shut-Off Handle (in Open Position) The In-Situ Calibration Check, conveniently performed at a No Flow (0 SCFM) condition, verifies the sensor s performance, its cleanliness, and the Flow Meter s operation and calibration. STEP 2 LIFT Lift the Probe Until Safety Chain is Taut, and Then Close the Valve as Shown in the Inset Safety Chain Valve in Closed Position LOOK obtain a no flow data point which can be compared against the original factory calibration listed on the name plate and on the calibration certificate. This is all possible due to the digitally driven bridge circuit which provides excellent reproducibility and virtual elimination of electronic drift which occurs in typical analog driven designs. When the measured signal matches the original NIST traceable calibration data the accuracy of the meter is verified and also confirms that the sensors are clean. This simple test provides a tremendous benefit to the user eliminating the cost and inconvenience of periodic factory calibration of the flow meter. STEP 3 B Look at the Milliwatt (mw) Reading on the Display (A), and Merely Compare it to the Flow Meter s Tag (B) The 3-Step In-Situ Field Check is the Easy, Cost- Effective Way to Verify the Meter s Calibration A SAGE METERING, INC. { 7 }