Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

Similar documents
Operating Instructions Part No

Operating Instructions Part No

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

RAM 4021-DPX Operation Manual

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

User s Guide. Pressure Controller for liquid delivery systems

RAM 4021 Operation Manual

RAM Operation Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Equipment Operating Procedure Glove Box

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

DIGITAL AUTOMATIC TYRE INFLATOR

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

BUBBLER CONTROL SYSTEM

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

with O 2 Controller Instruction Manual

Constant Pressure Inlet (CCN) Operator Manual

FX134, FX1234, FX3030 Problem and Solutions

MODEL 100 NITROGEN INFLATION CART

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Columbus Instruments

ACV-10 Automatic Control Valve

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

BUBBLER CONTROL SYSTEM

APA software instruction manual

TR Electronic Pressure Regulator. User s Manual

User s Guide. Vacuum Controller for liquid delivery systems

Installation Instructions

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

TEST BENCH FOR SAFETY VALVES

StockWeigh 500 D3632 US-B

Touch Screen Guide. OG-1500 and OG Part # T011

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

HumiSys HF High Flow RH Generator

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

R E D I C O N T R O L S

Pro 200 Series Furnace Operator's Manual

Bubble Tube Installations

User s Guide. Model ESM1500 FORCE TEST STAND

Installation Instructions

Instruction Manual Dräger MSI P7 and MSI P7 plus

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Workhorse-15 Oxygen Generator

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

AUTOMATIC GAS MANIFOLDS

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

CCT-7320/ROC-2313 Reverse Osmosis Controller

Single Pressure/ vacuum decay leak rate, loss, rate of loss, or occlusion tests with standard Cv valves.

ASSE International Product (Seal) Listing Program

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Burner Management System DEMO Operating instructions

Inert Air (N2) Systems Manual

Met One E-BAM Particulate Monitor

Installation Instructions

NTF-230 OPERATION MANUAL

Vacuum Model Nitrogen Tyre Inflation System Main Features: PN-8820 Nitrogen Tyre Inflator Operation Steps

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

Electronic Single and Twin Pump System Pressure Managers

SDM-2012 Docking Station Standalone Configuration Operator s Manual

Duplex Commercial Softeners

Manual Weighingblock VB2 series and Uniscale

Hydro-Control V User Guide

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

Instruction and Maintenance Manual

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Glove Box Installation Manual

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

A4s Operation Manual

Instruction and Maintenance Manual

Pressure Dump Valve Service Kit for Series 3000 Units

OPERATION MANUAL ID900

AX5000 Operational Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

THE UNIVENTOR 400 ANAESTHESIA UNIT

ELECTRONIC PLC SERIES Test Benches

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

PurgEye 100 IP65 WELD PURGE MONITOR USER INSTRUCTIONS. Argweld PurgEye Family Range of Weld Purge Monitors

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Series MTS300 Motorized Test Stands

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

NGP-250/500 Nitrogen Generator Quick Start Guide

[Instruments for vacuum measurement, checking and adjustment] 3

Force Test Stand Model ESM301 / ESM301L. Version 2. User s Guide

Protec P3000 (XL) Helium Sniffer Leak Detector

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

EMT EnvironmentalMonitoringTECHNOLOGIES

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Transcription:

Operations Manual Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

SG1 Overview and Dimensions 5.25 / 133 mm PS Power Supply Connection 4.06 / 103 mm Top View Back View Membrane Panel and Display Screen P2 Transducer Connection Power Connection +5, +/- 12 Volt 2.73 / 69 mm 3.50 / 89 mm Side View Power Cord with Switching Power Supply Utilizes 100 to 240 volts with 60 to 60 Hz P2 Transducer Assembly Page 2

How It Works The SG1 Pressure Controller is a very low pressure closed loop digital controller designed to maintain a low internal pressure on tubes or components being welded. Pressure is controlled dynamically by adjusting the orifice size of an iris valve (shown below) while monitoring the pressure produced by the restriction the orifice creates, given a certain pressure of purge gas. order to produce the programmed pressure (monitored by the P1 pressure transducer) the Iris Valve is closed to create an orifice that provides a flow restriction. The controller adjusts for any increase or decrease in pressure during the weld of flow variations which may result from a change of supply pressure or joint variation Often it is necessary to know what the pressure is at the actual weld site and since there can be a substantial pressure loss if the distance from the weld site to the pressure controller is great it is necessary to calibrate the pressure of P1 against the pressure at the weld with a P2 transducer. By monitoring the P2 pressure at the weld site prior to welding and knowing P1 the pressure loss of the particular distance from the weld to the controller can be calculated. Once this loss is known the appropriate P1 pressure can be controlled to meet the desired pressure at the weld site. After calibration and before welding P2 is removed. Iris Valve Programmable Controller P2 Mode Programmable Controller P1 Mode P1 P1 Pressure Chamber Purge Outlet from Iris Pressure Chamber Purge Inlet from weld ID Purge Outlet from Iris Iris Valve Purge Inlet from weld ID P2 Iris Valve Weld Fixture Weld Fixture Diagram of Pressure Control in P2 Mode Diagram of Pressure Control in P1 Mode Above is a diagram of the basic components of the pressure controller. A desired internal weld pressure is set on the Programmable Controller and the purge gas being exhausted from the weld ID is connected to the Pressure Chamber of the pressure controller. In Page 3

Start-Up Turn on the power by plugging the power cord with switching power supply into a 100 to 240 volt, 50 to 60 Hz power outlet and the other end of the supply into the pressure controller, as shown above. RESET reinitializes the system and returns the iris valve to its open position and sets the unit to atmospheric conditions. ADD increases or scrolls the value displayed on the screen. SUBTRACT decreases or scrolls the value displayed on the screen. OPEN/ CLOSE cycles the iris to the open or closed position. START/ STOP Begins or ends a cycle. Also used for Standby Mode. When powered the pressure controller will make an audible beep and will cycle the iris valve open. The display screen will display the message shown above, prompting the operator to select a Mode of Operation. Control Panel MODE selects the operating mode P1, P2 or PS CAL or Calibrate is used to compare the P1 pressure to P2. UPLINK allows communication to EXEL s EPS-2000 Power Supply UNITS selects the unit of measure for pressure Page 4

Modes of Operation There are three modes of operation for the pressure controller they are: 1. P1 (Single pressure transducer operation) 2. P2 (two pressure transducer operation) 3. PS (Welding power supply control of pressure controller) 4. Standard Pressure Table 2. mm H 2 O (millimeters of water) 3. ATM (atmospheres) 4. in Hg (inches of Mercury) 5. mm Hg (mm of Mercury) 6. cm H 2 O (centimeters of water) 7. Kpa (Kilopascals) Operation in P1 Mode In this example a 1.00 diameter tube will be welded so.800 in H 2 O is selected. NOTE: For more information on pressure and flow selections refer to Mode 4 of operation or refer to Semi Standard F78-0304 on page Select the P1 Mode by pushing the MODE button until the screen above can be seen. The message on the screen states that this mode uses only one transducer. This transducer is internal to the pressure controller. In this mode no calibration is required for operation. By pushing the START/ STOP button, P1 Mode will proceed. Before turning on the purge the weld to be made must be set-up. Above is a typical setup using the RTU- 016-FMJ Fixture to weld a 1.00 diameter tube. To the right of the weld is the purge inlet, in this case pure Argon and to the left is the SG1 Pressure Controller. In P1 Mode the tubing used to connect the pressure controller to the welded component should be as short as possible and at least of the same diameter as the components being welded on order to minimize pressure drop. The Next screen that appears allows setting of the desired pressure. By pushing the ADD or SUB- TRACT button the displayed pressure will either increase or decrease. The default unit of measure for pressure is H 2 O however, several other options are available by depressing the UNITS button. The following units of measure may be selected: 1. in H 2 O (inches of water) Page 5

Operation in P1 Mode Continued Before fixturing the weld joint as in the P1 Mode the pressure at the weld joint must be calibrated. When the START button is depressed the pressure controller begins closing the iris valve and monitoring the internal pressure until the desired pressure is obtained. The view above shows the programmed pressure of 0.800 in H 2 O and an actual internal pressure of 0.782. This actual pressure will vary slightly based on flow turbulence and is the same as the slight bounce experienced when a Magnehelic is used. A union type fitting with a 1/4 tube leg must be used to connect the two components to be welded and allow the P2 Transducer to be attached. The programmed pressure can usually be achieved in about 10 to 15 seconds depending the flow and desired pressure. As soon as the pressure is obtained the weld can be made. During the welding process the pressure controller continues to maintain the programmed pressure compensating for sudden pressure loss during arc start and increase after the weld seam has been sealed. Operation in P2 Mode Attach the P2 Transducer to the Union. This attachment can be made with compression fittings with polymer ferrules of with poly tube. The P2 Mode requires that the P2 transducer be attached so that the pressure drop from the weld site to the pressure controller can be calibrated. If the P2 Transducer is added after the pressure controller has been turned on the reset button mush be pressed to reinitialize and recognize the transducer. Page 6

Operation in P2 Mode Continued Using the mode button select the P2 Mode. A message is displayed noting that two transducers are needed the first is built into the controller and the second is the P2 transducer. Calibration is also required to measure the pressure drop between the weld site and the controller. Adjust the pressure to the desired level, in this case 0.800 in H 2 O. Turn on the purge supply then push START. By pushing the CAL (Calibrate Button) the instruction PLACE SENSOR 2 AT WELD JIONT THEN PUSH START is displayed. This has been done by placing the P2 Transducer on the union at the weld joint. The controller will close the iris valve until the pressure at the weld site (P2) is the desired 0.800 in H 2 O, in this case S1 is 0.744 in H 2 O. Also display in the screen is the pressure at the controller, in the case S2 is 0.926 in H 2 O. Also displayed is the pressure drop from the weld site to the controller in this case DP or delta pressure is 0.18 in H 2 O. As in P1 Mode the default pressure is set to 1.00 in H 2 O After calibration is complete and the START button is pushed the above message is displayed. Remove the P2 Sensor and union and fixture the weld joint. Page 7

Operation in P2 Mode Continued Now that the controller is calibrated the weld can be made. By pushing START the controller will begin closing the iris to reach the desired pressure located in the controller, which is 0.800 in H 2 O - 0.182 in H 2 O or 0.618 in H 2 O. The tolerance or flow turbulence may give a slightly different reading, in this case 0.634 in H 2 O. Tube Size 1/4 in. 6 mm 3/8 in. 10 mm 1/2 in. 12 mm 3/4 in. 20 mm Wall Thickness 0.035 in. 1 mm 0.035 in. 1 mm 0.049 in. 1.2 mm 0.065 in. 1.5 mm Minimum ID Purge Rate 10 scfh 3.5 l/m 10 scfh 3.5 l/m 15 scfh 7 l/m 20 scfh 10 l/m ID Purge Pressure 2.9 to 3.4 in H 2 O 75 to 86 mm H 2 O 1.5 to 2.5 in H 2 O 38 to 64 mm H 2 O 1.0 to 1.5 in H 2 O 25 to 38 mm H 2 O 0.5 to 1.1 in H 2 O 13 to 28 mm H 2 O Restrictor Size 1/8 in. 3.2 mm 1/8 in. 3.2 mm 1/4 in. 6 mm 1/4 in. 6 mm The table to the left is programmed into the SG1 Pressure Controller in Mode 4 and can be scrolled through using the ADD and SUBTRACT keys. These pressures and flows are recommended in order to give color free welding in the ID of the tube. Since this is a Semi Standard other flows and pressures may be used for other applications and this table is intended as a starting point. 1 in. 25 mm 0.065 in. 1.5 mm 40 scfh 20 l/m 0.5 to 1.0 in H 2 O 13 to 25 mm H 2 O 1/4 in. 6 mm 1 1 / 2 in. 38 mm 0.065 in. 1.5 mm 80 scfh 40 l/m 0.5 to 0.7 in H 2 O 13 to 18 mm H 2 O 1/4 in. 6 mm 2 in. 50 mm 0.065 in. 1.5 mm 150 scfh 70 l/m 0.4 to 0.7 in H 2 O 13 to 18 mm H 2 O 3/8 in. 10 mm 3 in. 75 mm 0.065 in. 1.5 mm 320 scfh 150 l/m 0.2 to 0.5 in H 2 O 5 to 13 mm H 2 O 1/2 in. 12 mm 4 in. 100 mm 0.083 in. 2 mm 600 scfh 275 l/m 0.2 to 0.4 in H 2 O 5 to 13 mm H 2 O 3/4 in. 20 mm 6 in. 150 mm 0.083 in. 2 mm 1000 scfh 475 l/m 0.2 to 0.4 in H 2 O 5 to 13 mm H 2 O 3/4 in. 20 mm Page 8

Standby Mode In order to reduce the amount of time for the SG1 Pressure Controller to achieve the programmed pressure between welds, the Standby Mode is used. After pushing the Start/Stop button for the first time the pressure controller requires about 10 seconds to acquire the set pressure. After the first weld is complete, pushing Start/Stop will cause the pressure controller to enter the Standby Mode where the iris valve is opened until the internal pressure reading is 0 this means the iris opens only slightly. When ready to make the next weld simple push Start/Stop again and the iris valve quickly closes until the proper pressure is reached. Because the valve is already partly closed as much as 6 seconds is saved, making the total response time as little as 4 seconds. See graph below. Integration with the EPS-2000 Power Supply By using the cable provided with the SG1 Pressure Controller it is possible to integrate the pressure controller with the EPS-2000 Power Supply. By doing this it will not be necessary to push the Start/Stop button on the pressure controller between each weld. The EPS-200 Power Supply automatically sends the Start/ Stop command before and after each weld. Communication Cable SG1 Pressure Controller Page 9 EPS-2000 Power Supply

Fault Modes If at any time during operation a pressure loss beyond the pressure controllers control limit is reached the controller will produce the error message below, the red warning light will flash and there will be an audible warning beep. Maintenance of the Iris Occasionally it is necessary to apply a light grease to the iris to insure proper operation and tight sealing. Apply a light grease to the face of the leaves of the iris for proper lubrication. Should the controller be unable to control at low pressures and flows it may be necessary to apply this lubricate. Apply Light Grease Page 10