Powder Measure. Care & Usage Instructions. Instructions # Product # Revision: A

Similar documents
COMPETITION DIES P R O D U C T I N S T R U C T I O N S

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Detroit Speed, Inc. A-body Rear Coilover Conversion Kit A-body (Moser Rear Axle) P/N: , , , , ,

Kentucky Long Rifle.50 BMG Model: BA M-N-M Tactical. Users Guide

GOLD MEDAL DIES P R O D U C T I N S T R U C T I O N S

USER S MANUAL QUESTIONS? CAUTION. Model No. FMEX Serial No. Write the serial number in the space above for reference. Serial Number Decal

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

1.0 - OPENING AND CLOSING THE DOOR

Techcon Systems TS1254 Pressure Pot

INSTRUCTION MANUAL FOR

Adjustable. Unloader Valve. O&M Manual. Part #

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

BELT DRIVE INDOOR CYCLING BIKE SF-B1712

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Assembling a Can Sealer FNH-00022

INDOOR CYCLING BIKE SF-B1110 USER MANUAL

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

OWNER'S MANUAL LOCK-N-LOAD BULLET FEEDER (PISTOL)

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

M16 R / M1600 R USER S MANUAL WARNING: READ THE INSTRUCTIONS AND SAFETY PRECAUTIONS IN THIS MANUAL CAREFULLY BEFORE USING THIS FIREARM.

Final Assembly Instructions Bikes with Threaded Headsets

EZee Glider Manual. Tools needed for Assembly: Wrench (included) Philips Screwdriver (not included) Assembly Instructions

Techcon Systems TS1258 Pressure Pot

Final Assembly Instructions Bikes with 16 Wheel Size

Mini Glider Manual. Your Glider comes partially assembled. The front wheel and the handlebars require assembly.

Santa Fe Cycles Assembly Guide Introduction

Read Before Operating!

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Read Before Operating!

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

VR1 Owner s Manual. Vigilance Rifles, Inc Plum Lane Redlands, CA P F

MAGNETIC INDOOR CYCLING BIKE

Mini Mr.Bulletfeeder by Double-Alpha

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Final Assembly Instructions Bikes with Threaded Headsets

Instruction Manual Updated 7/26/2011 Ver. 2.2

CLASS CYCLE P8000 OWNER'S MANUAL JOHNSON HEALTH TECH. CO., LTD.

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

Bullet Feeder Pistol Kit

Final Assembly Instructions Bikes with Quill Stems

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

OWNER S MANUAL READ THIS MANUAL BEFORE USING YOUR NEW AIRGUN

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

E Lightband Compression Tool Operating Procedure

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

SPM INDOOR TRAINING CYCLE ASSEMBLY MANUAL MODEL: SPM

Armorer s Handgun Sight Tool

3/8" Dr. Air Butterfly Impact Wrench

Model: 7200 Collegiate Volleyball System

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

SAFETY RULES WARNING: READ THESE SAFETY RULES & OPERATORS MANUAL BEFORE HANDLING YOUR FIREARM

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

4 ANGLE GRINDER MODEL NO: CAT 52 PART

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

Retractable Hose Reel with 3/8" x 50' PVC Hose

OPERATING AND MAINTENANCE MANUAL

LNG Regulator Test Kit

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

SILENT-SR SOUND SUPPRESSOR

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Assembly Instructions & Manual. Configuration subject to change

Pilot Check Valve: Metal Body Type

Sunset Swings By Health in Motion, LLC

RULES FOR SAFE FIRING:

MAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL

Detroit Speed, Inc. Rear Coilover Conversion Kit Camaro/Firebird P/N: &

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

Lock-N-Load. Bullet Feeder

8-GAL PNEUMATIC OIL DISPENSER

Pressure Dump Valve Service Kit for Series 2300 Units

WARNING: FOR OUTDOOR USE ONLY

MAINTENANCE PROCEDURE FOR X 650

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

BELT DRIVE PREMIUM INDOOR CYCLING BIKE SF-B1509 USER MANUAL

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Installation of Your SprayMaster System

PIVOT SHUTTLE Chain Ring Replacement Maintenance Procedure

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

INSTALLATION & MAINTENANCE INSTRUCTION

FX IMPACT OWNER S MANUAL

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

WARNING. Paintball Pistol. Paintball Pistol

Backboard and Rim Owners Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Model 130M Pneumatic Controller

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

Pressure Dump Valve Service Kit for Series 3000 Units

Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung. U.S. Patent No. 7,922,246. Patent Pending

Soccer Goal. Model: SG20 Series. Installation, Operation and Maintenance Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TWO POST RAM PACKAGE 55 GALLON

Transcription:

Powder Measure Care & Usage Instructions Instructions #1048578 Product #909292 Revision: A 1

INFORMATION AND SAFETY INSTRUCTIONS Ammunition reloading can be dangerous if done improperly and should not be attempted by persons not willing and able to read and follow instructions exactly. Children should not be permitted to reload ammunition without strict parental supervision. Always wear safety glasses when reloading and shooting. Ammunition loaded with these tools and data should only be used in modern guns in good condition. We do not accept responsibility for ammunition loaded with these tools or data as we have no control over the manufacture and storage of components or loading procedure and techniques. Primers and gun powders, like gasoline and matches, can be dangerous if improperly handled or misused. GENERAL To remove the metering device, always be sure to drop any charge first. Always be sure that your Micrometer Metering device is locked in place before operating. Always verify your charges with a scale before loading. Any moisture in the unit will cause powder to stick, and charge weights will vary drastically. Use the equipment as manufacture recommends. Study the instructions carefully and become thoroughly familiar with the operation of the product. Don t take short cuts. Keep tools and components neat, clean and orderly, Promptly clean up any powder spills. Always wear adequate eye protection. If any unusual resistance is encountered when moving the operating handle, STOP IMMEDIATELY and investigate the cause. To proceed against unusual resistance may damage equipment and/or cause serious injury! POWDER HANDLING Store primers and powder beyond the reach of children and away from heat, dampness, open flames and electrical equipment. DO NOT use any powder unless its identity is positively known. Discard all mixed powders and those of uncertain or unknown identity. Before charging cases, settle the powder in the powder hopper. Throw and check the weight of at least ten charges. This will assure you that the correct powder charge is being thrown. Use of a powder baffle will help to throw consistent charges. After a reloading session ends, pour the remaining powder back in its original factory container. This will preserve the identity and shelf life of the powder. DO NOT smoke while handling powder or primers. DO NOT USE BLACK POWDER with the Frankford Arsenal Powder Measure. IMPORTANT! YOU MUST DO BEFORE USE Thank you for purchasing the Frankford Arsenal Powder Measure. The Powder Measure has been shipped with a corrosion resistant oily film that must be removed before use. Failure to remove this film may cause powder to stick to the inside surfaces, which will result in varying powder charges. The film can be removed using aerosol cleaner/degreaser or hot soapy water. If the components are cleaned with water, be sure to thoroughly dry the entire component using compressed air or warm air from a hair dryer. 2

CONTENT 5 4 12 BILL OF MATERIAL No. COMPONENT NAME Part No. Type Qty. 1 POWDER MEASURE 1050179 ASSEMBLY 1 2 BODY 1028428 PART 1 3 ROTOR 123747 PART 1 4 HOPPER TUBE 1028457 PART 1 5 BAFFLE 1023745 PART 1 6 HANDLE 1023749 PART 1 7 ROTOR LOCK SCREW 1023748 PART 1 8 KNOB 1023750 PART 1 9 HANDLE SCREW 1023752 PART 2 10 THUMB SCREW 1023754 PART 1 11 DROP TUBE 1028698 PART 1 12 CAP 1032958 PART 1 13 METER ASSEMBLY 1034129 ASSEMBLY 1 14 METER BODY 1033663 PART 1 15 THIMBLE 1033633 PART 1 16 PLUNGER 1033678 PART 1 17 O-RING 1034130 PART 1 18 METER LOCK SCREW 1023748 PART 1 19 22 CAL. NOZZLE 1044577 PART 1 20 LOCK NUT 1028777 PART 1 21 BENCH MOUNT 1028548 PART 1 22 SHELF MOUNT 1023904 PART 1 2 9 6 8 3 7 16 14 17 10 15 22 21 11 18 20 19 3

ASSEMBLY Select mounting configuration bracket; Shelf Mount or Bench Mount. (Photo 2) 2. Set the Body on bracket assembly and secure with Thumbscrew (Photo 3) 1. Attach bracket to bench using your own hardware. (Photo 1a & 1b) Thread Drop Tube into 7/8 threaded hole in bracket. Secure with lock nut. (Photo 2) (Photo 3) (Photo 1a) Thumbscrew 3. For right handed operation, install Rotor into Body from right to left. For left handed operation, install Rotor into Body from left to right. (Photo 4) (Photo 1b) Right to Left (Photo 4) 4

4. Set Meter to zero position. Holding the Meter Body, twist the Thimble so the 10 position on the Meter Body is even with the top edge of the Thimble. (Photo 5a & 5b) (Photo 8) 6. With Handle oriented toward you, install the Meter Assembly into the Rotor with the center line of the Meter Body facing up. You will feel the Meter Assembly bottom out against the Body. Tighten the Rotor Lock Screw located on the side of the Rotor (opposite side from the Handle) to lock the Meter Assembly in place. (Photo 9a & 9b) (Photo 9a) (Photo 5a) (Photo 5b) (Photo 6) If this position does not align with the 0 mark on the Thimble (Photo 6) do the following: a. Loosen the Meter Lock Screw at the bottom of the Thimble and twist it so it is aligned with the center line on the Meter Body. Retighten the Lock Screw at the bottom of the Thimble. (Photo 7) (Photo 9b) 7. Install Hopper Tube with Baffle and Cap onto Body. (Photo 10) 8. Install 22 Caliber Nozzle (Photo 11) (Photo 7) 5. If the 10 position on the Meter Body is even with the top edge of the Thimble and the 0 mark on the Thimble is aligned with the center line of the Meter Body twist the Thimble one complete turn clockwise. This is the zero position on the Meter. (Photo 8) (Photo 10) (Photo 11) 5

6 OPERATION AND ADJUSTMENT Do not proceed until the inside surfaces have been inspected and cleaned of any powder remaining from previous use. If this is the first use, all inside surfaces must be degreased, clean and completely dry. Before accurate measures of powder can be thrown, you must first run your intended powder through the system to develop a film of powder residue on all the internal surfaces. To do this, follow the steps detailed below: 1. Add enough powder to the Hopper Tube to completely cover the Baffle and extend up the Tube several Indicator Lines. This is the minimum amount of powder required to provide maximum consistency in powder charges. The Baffle is placed in the bottom of the Hopper Tube to support the weight of the powder column, so the Hopper Tube may be filled to its maximum capacity without decreasing the consistency in the powder charges. 2. Adjust the Meter to the highest number setting by twisting the Thimble counter-clockwise, as if you unthreading it from the assembly. Keep in mind the Meter Body should be secured within the Rotor with the Lock Screw and should not be turning as the Thimble is adjusted. 3. Hold or place a container under the Drop Tube/Nozzle and cycle the Rotor until all the powder has been run through the system. Do this slowly and consistently to get a feel for the operation of the Powder Measure. After this powder has been run through, a sufficient amount of powder residue will have distributed itself over the internal surfaces, preventing the powder from hanging up or sticking to the internal surfaces during your loading session. Next, begin the trial and error process of adjusting the Meter to the desired charge weight. Indicator lines are provided on the Meter Body and Thimble, but due to the many sizes and shapes of powder granules, they do not directly correspond to an actual charge weight. a. With the Thimble adjusted to the highest setting (heaviest charge), rotate the Rotor Handle down allowing it to stop abruptly at the end of its travel b. Rotate the Rotor Handle back up allowing it to stop abruptly at the end of its travel to dispense the powder onto a powder scale pan. Allow enough time for all the powder to run through the Nozzle. c. Weigh the charge and dump it back into the Hopper Tube d. Compare the weight of the charge with your desired charge weight. Make note of the number indicated on the Meter Body. For example: If your desired charge weight is ½ of the dispensed charge weight, adjust the Meter to the number approximately ½ of the number indicated on the Body. e. Adjust the Meter Thimble by twisting it clockwise to decrease the charge weight. Twist the Thimble counterclockwise to increase the charge weight. f. Repeatedly adjust the Meter and weigh charges until the desired charge weight is obtained. Verify all your charge weights with an accurate powder scale like the Frankford Arsenal Precision Scale before charging cases. NOTE: Check the level of powder in the Hopper Tube during use. Add powder as needed to maintain the minimum level discussed in Step 1 of the Operation instructions. Also periodically check the Hopper Tube is fully seated within the Powder Measure Body. Failure to do so may result in the Hopper Tube working itself out of the Body and dumping its contents.

When the reloading session is complete, empty any remaining powder in the assembly into its original container or another suitable container that is clearly labeled. TIPS AND PRECAUTIONS 1. Verify all charges with an accurate powder scale before charging cases. 2. Rotate lever at uniform speed while throwing a charge. Make sure to cycle the lever to a full stop at the top and bottom of the Body. 3. Periodically check the Hopper Tube is fully seated within the Body during operation 7

8 Powder Measure