Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Similar documents
Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

The Principles of Vacuum Technology

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Matching Vacuum Pump to Process

The Broadest Gauging Line in the Industry

The Experts in Vacuum Solutions

This educational seminar discusses creating, measuring, and troubleshooting Ultra-High Vacuum ( Torr) systems.

Choosing a Quadrupole Gas Analyzer Application Note #9

Gun Vacuum Performance Measurements February 2003

Fig. 1: Mechanical vacuum gauge (left) and capacitive vacuum gauge (right)

Chapter 8: Cryo-sorption pumps

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

1)! DO NOT PROCEED BEYOND THIS MARK

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Introductory Lab: Vacuum Methods

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

The Helium Leak Detector

VACUUM PUMP/ LEAK DETECTOR CATALOG

ASPECTS OF VACUUM TECHNOLOGY. (a) To see something of the operation of vacuum pumps; Then, we will use the vacuum system for one of two experiments:

Chapter 5: Subatmospheric Total Pressure Gauges

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

EXERCISE 2: THE VACUUM SYSTEM

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

Dr. José Miguel JIMENEZ CERN, Technology Department Head of the Vacuum, Surfaces and Coatings group

Cryo-Evaporator Operation

Practical approach and problems in in-situ RGA calibration

Residual Gas Analysis Systems for Industry

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

Go/no-go test for the acceptance of components for unbaked vacuum sectors

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Gases and Pressure SECTION 11.1

How To Choose a Roughing/Backing Pump for the Turbo and Drag Family

Pressure Measurement

How To Use Getters and Getter Pumps

Total Pressure Measurement Using Residual Gas Analyzers

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Development of o-carborane boronization for MST

Extreme High Vacuum: The Need, Production, and Measurement

Resist round robin ELETTRA

Approved by Principal Investigator Date: Approved by Super User: Date:

Operating Procedures for Metal Evaporator I

Both physical and chemical effects come into play either separately or in combination.

Major Design Features

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

Name /74. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Vacuum and Surface Contamination Problems in Experiments with Ultracold Neutrons

at NIST: ultra-low outgassing rates

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Description Advanced Features Typical Applications

Chapter 10: Gases. Characteristics of Gases

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

SINGULUS TECHNOLOGIES

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

OOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

CHEMISTRY - CLUTCH CH.5 - GASES.

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

DC gun high voltage conditioning with Krypton gas Carlos Hernandez-Garcia October 2008

VACUUM TECHNIQUES. Why? How else might you make the measurement?

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

APPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY

Leak Checking Large Vacuum Chambers

Chapter 13. Gases. Copyright Cengage Learning. All rights reserved 1

EVOLUTION OF VACUUM PUMP REQUIREMENTS FOR LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Instrumentation & Data Acquisition Systems

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Vacuum Technology. Michael McKeown

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *

EFFECTS OF BAFFLE SIZE ON PRESSURE DISTRIBUTION IN VACUUM CHAMBER DURING DYNAMIC GAS FLOW

MMRC PVD Evaporator Instructions

Lecture 19 Fluids: density, pressure, Pascal s principle and Buoyancy.

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Chemistry Chapter 11 Test Review

School of Chemistry SOP For Operation Of Glove Boxes

Quadruple mass spectrometers (transducer type)

Vacuum pressure measurement (part 2) Indirect vacuum measurement devices

Vacuum Science and Technology in Accelerators

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

SAES Packaging service. making innovation happen, together

Oxygen Contamination

Chapter 5: Gases 5.1 Pressure Why study gases? An understanding of real world phenomena. An understanding of how science works.

Chapter 5. Nov 6 1:02 PM

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.


Transcription:

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007 Vacuum increases the mean-free-path of gas molecules. Vacuum prevents chemical reaction. Vacuum removes contaminants from surfaces. Vacuum reduces the particle flux on a surface. Vacuum allows the operation of sensitive components, high voltages, etc. X-ray Photoelectron Spectrometer operates in UHV conditions for surface-sensitive spectroscopy for elemental analysis, chemical analysis, etc.

Units 1 atm = 760 mm Hg = 760 torr MKS 1 N/m 2 = 1 Pa (Pascal) cgs 1 dyne/cm 2 = 1 microbar (barometric) 1 bar = 750 torr ~ 1 atm 100 Pa = 1 millibar =.75 torr ~ 1 torr 1 millitorr = 1 micron (of Hg)

Pressure Fractions of Atm Pressure Number Density (cm -3 ) Mean Free Path Particle Flux (cm -2 sec -1 ) Time - One Monolayer to stick 1 760 torr 2.5 x 10 19 65 nm 2.9 x 10 23 3 nsec 10-3.76 torr 2.5 x 10 16 65 microns 2.9 x 10 20 3 µsec 10-5 7.6 mtorr 2.5 x 10 14 6.5 mm 2.9 x 10 18 300 µsec Rough pump 10-8 7.6 x 10-6 torr 2.5 x 10 11 6.5 m 2.9 x 10 15 30 msec HV 10-13 7.6 x 10-11 torr 2.5 x 10 6 650 km 2.9 x 10 10 3.5 days UHV

6.5 mm is a shorter distance than any dimension that characterizes almost any vacuum system: The length or diameter of any tube between chamber and pump, or to a pressure gauge. The length between a deposition device and the substrate to be deposited on. At 7.6 x 10-3 torr we expect many gas phase collisions before a gas molecule bounces from one surface to the next. Continuum or Viscous Flow. By contrast, 6.5 m is a longer distance than characteristic dimensions of most vacuum systems. Following a molecule desorbing from a surface at 7.6 x 10-6 torr will show, on average, that the molecule will hit another surface before it hits another gas phase molecule. Molecular Flow In Viscous Flow the conductances increases linearly (and sharply) with pressure. At atmospheric pressure, a particular component's conductance may be 10 4 times higher than its Molecular Flow (minimal) value.

Base Pressure (of a vacuum system) capped all leaks, stopped all flow of gases, and waited a long time. It is asymptotically approached. Ultimate vacuum (of a pump)- cap the pump's inlet and measure the equilibrium pressure after operating the pump for many hours. Outgassing rates = amount of gas coming out (off) something in a given time. PRESSURE x VOLUME per unit AREA per unit TIME = Torr-liters/cm 2 -sec Wall Desorption. A spherical chamber, 1 ft diameter at 1 x 10-6 torr, with one monolayer of adsorbed water vapor on inner walls, has ~7000 times more molecules on the surface than in the gas-phase. Other issues Virtual leaks. High vapor pressure materials - sulphur, Pb, or Zn containing. Brass (bronzes are OK), Common solders (Ag solder OK). Hydrocarbons and fingerprints. Bake-outs (limits gaskets and other materials).

Decreasing Gas Load Use only the lowest outgassing materials in construction Use appropriate vacuum design and welding techniques Physically and chemically clean the components and chamber walls Thoroughly leak check components prior to initial assembly Bake chamber walls to desorb gas molecules Freeze molecules to the wall with cryogen cooling Use a pump with minimum backstreaming and/or operate in a range where it will be minimal. Increasing Pump Throughput Replace existing pump with another of larger pumping speed (or add more pumps) Increase effective pumping speed by increasing tubing diameter and reducing number of bends Choose proper pump for type of gas being pumped Turbo pump bad for Hydrogen. Ion pumps bad for noble gasses. Triode variant better. Cryo pumps bad for Helium, Hydrogen. Hydrogen, ozone, etc. may make some pumps explode!

Rotary Vane pumps (oil lubricated). From atm to ~ 10 mtorr. Oil vapor may backstream for P<1 torr. Dry pumps (piston, diaphragm, etc.) becoming more popular. Typically they cost more and have higher ultimate pressures. Turbo pumps. 10-3 to 10-11 torr range. Blades rotate at ~ 50,000 RPM. Gas molecules, hit by the underside of the angled blades, move with momentum in the direction of the higher pressure exhaust. Must back these by a rotary vane or a dry pump. Be careful not to vent too quickly, nor to back-stream oil into the chamber! (This will happen if you vent the main vacuum while keeping the rotary vane pump under vacuum.) Main Vacuum chamber To backing pump. Ion pumps. 10-5 to 10-11 torr range. Gas molecules ionized, accelerated to titanium plates. Ions chemically react and/or buried. Clean/zero vibration. Ti lifetimes short for high pressures.

Pressure Measurement Thermocouple or TC guage. 10 to 10-3 torr range. A hot filament loses heat to gas in system. TC measures temperature of filament. Pirani. 20 to 10-5 torr range. Same as TC but compares system to a reference. Capacitance Manometer. ~ 4 decades with varying max pressure (.1 1000 torr) Most accurate for high pressure range.

Pressure Measurement Ion or Bayard-Alpert. Glass tubulated 10-4 to 10-9 torr Nude 10-4 to 2x10-11 torr Low pressures dominated by x-ray limit -Electrons striking electron collector give off soft X- rays. These strike the ion collector giving off photoelectrons, affecting measured current. Different gas species have different sensitivities. Easy to ionize acetone, difficult to ionize H. Residual Gas Analyzers (RGA s). Quadrupolar electric field measures e/m ratio of ionized gas molecules. Most sensitive of all for UHV conditions. Great for helium leak detection and vacuum diagnostics.

Hemisphere X-ray source 2.75 gate valve Sample transfer Don t touch anything on this side! xyz sample manipulator Angle valve

Photoemission Spectroscopy sample hν Energy High K.E. Low B.E. e - analyzer E F e- hν Density of States Low K.E. High B.E. Primary electrons no scattering events. Contain information of density of states Secondary electrons (inelastic background) increases with decreasing kinetic energy.

XPS of copper metal