Antaris IGS Gas Analyzer

Similar documents
Pycnomatic ATC For solids and powders density

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Lecture Bottles Purchase & Disposal

Gas monitoring using GASMET FTIR

Gas Mixture Two Components. Gas Mixtures Two Components

Technical Manual. Sensepoint XCD Gas Detector

Rapid and Reliable Detection of Dissolved Gases in Water

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Vehicle and Engine Emissions Testing

FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

MB3000-CH90 and MBGAS-3000CH FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

Improve Process Reliability

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Nonrefillable Cylinders

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

EasyLine Continuous Gas Analyzers. So smart, they re simple

CYLINDER VALVE GUIDELINES TD 12/15/E

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

FTIR Users Group Meeting FTIR development

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

Application Note AN-107

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Scientific and Technical Gases Ltd

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

HiQ Specialty Gases and Specialty Equipment. Precision matters. In everything we do.

PRECISION GAS MIXTURES

Use of Hazardous Gases Standard Operating Procedure

S on equipment and pipelines along with the constant threat to personnel safety justify major investment in H 2

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Micro Motion 3098 Gas Specific Gravity Meter

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Receiving Cylinders and Containers

STORAGE AND USE OF HIGH HAZARD GAS

Non-refillable canister solutions for ultimate portability

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

3 HiQ Specialty Gases and Specialty Equipment. Precision matters in everything we do

The Standard of Excellence in Safety, Quality, and Performance

MINIRAE 2000 & MULTIRAE PRE-PROGRAMMED COMPOUND LIBRARIES

Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

SENSOR SELECTION GUIDE

Leaders in Calibration Gas Solutions

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Agilent 490 Micro GC Natural Gas Analyzer

Low gas volume & flow measurements made easier Gas Endeavour

HiQ laboratory gas generators.

Setting a New Standard in Flash Chromatography Performance

Discovery HP-TGA 75/750. Site Preparation Guide

Chapter 22 Testing Protocols

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Safe Method of Use 9 HSNO Class 2 Gases

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Los Gatos Research. High performance analysers for the measurement of trace gases, greenhouse gases and stable Isotopes

SPECIALTY GASES LASAL. laser cutting and welding technologies. Photo courtesy of Alabama Laser.

APPLICATION NOTE. GC Integrated Permeation Device

Gas-Detection Instruments

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

GAS DETECTION: CALIBRATION GAS

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Specialty Gases + World-Class Performance

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Instrumental Technique GAS CYLINDER

Rare Gas Applications

Real-time gas analysis and software for the management of bioprocessing

FOURIER TRANSFORM INFRARED SPECTROSCOPY

Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface

Liquid Ring Compressors Engineered-to-Order Compressor Systems

THERMAL MASS FLOW MEASUREMENT FOR GASES

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Steam Turbine Performance Measurement. Pressure Measurement

sorting solutions osx separator series

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Transcription:

m o l e c u l a r s p e c t r o s c o p y Antaris IGS Gas Analyzer Exceptional Multicomponent FT-IR Gas Analysis Bulk Gas Purity Analysis Specialty Gas Combustion Emissions Monitoring and Air Bag Effluent Analysis Environmental Breathing Gas Semiconductor/Electronic Gas Suppliers Part of Thermo Fisher Scientific

I NTUITIVE G AS A NALYSIS The operation of the Thermo Scientific Antaris IGS gas analyzer is accomplished with Thermo Scientific RESULT software, specifically designed for process applications and routine analysis on the manufacturing floor. The revolutionary design of this software provides easy-to-use tools for routine analysis, method development, method transfer, operation setup, and data analysis. From Spectra to RESULTS: RESULT Analyzer Software Capable of collecting and analyzing spectra at 2 scans per second (2 Hertz data collect) at 0.5 cm -1 resolution Push-button operation requiring minimal operator training User operation defined by system login. Complete system security with user passwords, log-ins, and digital signatures Remote-start capabilities Real-time component quantitative results Run-time gas analysis interface allowing real-time display of control charts, multiple quantitative curves (concentration over time) and spectra Integrated operator Standard Operating Procedures (SOP s) Output of real-time results via OPC server for use by Manufacturing Execution Systems (MES) Software control of gas cell temperature, and monitoring of gas pressure Automatic archival of component concentration, spectra, interferograms, and gas analysis parameters Customizable reports Execution of multiple quantitative methods during a single analysis, an essential tool for some analyses, including combustion gases Powerful data analysis viewer for reviewing completed measurements. Review complete concentration curves and single or multiple groups of spectra TQ Analyst Chemometric Gas Analysis Tool Thermo Scientific TQ Analyst software delivers method development tools specifically suited to meet the demanding needs of gas analysis Automated selection tools for method, region, pathlength, and standards Automatic import of existing Quant Pad and TQ Analyst methods Composite components a unique feature providing the ability to produce a computed value from the concentration results, including multiple peaks calculations. This is useful to compute gas species such as the total NO x value Interference components provides the ability to ignore gas components that may introduce error due to interfering spectral bands Multiple spectral regions using common baseline Variety of pathlength, temperature, pressure, and baseline correction tools Diagnostic tools including Principle Component, Variance Spectrum, Pure Component Spectra, Correlation Spectra, and Cross Validation RESULT viewer interface Operation run time gas analysis report

Unparalleled High-Speed Gas Analysis Through Superior Spectrometer Design and Performance Computer Automation The Antaris IGS system provides powerful integration of hardware and software for intuitive operation, while guaranteeing complete, accurate analysis for every measurement. In addition to the automatic setting of collection and system parameters, the analyzer also provides monitoring of gas cell temperature and pressure. Gas cell temperature can be controlled by the software, as well as storing temperature and pressure information with archived spectra. Automated Data Output This analyzer is capable of transferring real-time results to a LIMS or PCS system using flexible output tools including Ethernet (OPC server) and a variety of industry standard protocols. Automated System Qualification With the ValPro system qualification package, the Antaris IGS analyzer incorporates an internal validation standards wheel to perform automated spectrometer tests as defined by the European and Japanese Pharmacopeia. The proprietary validation wheel contains all the NPL and NIST traceable standards necessary to perform wavelength accuracy, resolution, linearity, system noise and energy throughput tests. System performance verification and qualification is initiated with the push of a button. The unique dual beampath design eliminates the possibility of operator error and damage to the reference standards.

Industrial Spectrometer Gas Analysis System The unique Antaris IGS analyzer is an FT-IR spectrometer designed for use in harsh, industrial environments. It provides a robust yet small footprint package for either rack-mount or table-top operation in at-line, near-line or on-line implementation. The system is compatible with industry-standard 19-inch racks. Open Sampling Architecture The Antaris IGS analyzer is designed to accommodate a variety of gas cell options, while maintaining a compact system footprint. The analyzer can be configured with a wide range of gas cells for a variety of samples and concentrations for corrosive, caustic, heated, and ambient analysis. Unique Dual Beampath Design Ideal for system performance qualification, push-button automation allows operators to easily verify the system performance, independent of a gas cell and the calibration. This makes for easy trouble-shooting of potential failures. The unique industrial design also protects spectrometer components from harmful gases should a gas line or gas cell fail. Analysis Path Validation Path Method transferability is made possible by unparalleled stability, precision, accuracy, and reproducibility. The Antaris IGS analyzer provides research-grade system performance in an industrial spectrometer. To reduce system-to-system spectrometer variability, the analyzer is manufactured in a stringent ISO 9000 environment using manufacturing tests to ensure system-to-system matching. Each analyzer uses precision-based component layout with permanently aligned optics. High-speed data acquisition at high spectral resolution for real-time gas analysis. Made possible by the Vectra interferometer, the Antaris IGS system continually monitors itself and provides real-time automatic optimization of the optical signal. The Vectra interferometer with dynamic alignment is also used in Nicolet research FT-IR spectrometers. It provides exceptional high resolution line shapes, superior long and short term stability, and high speed/high resolution data collection. This combination of speed and performance provides a system capable of collecting data at 2 scans per second at 0.5 cm -1 resolution, ideal for detailed analysis of rapidly changing complex gas mixtures. The dynamically aligned interferometer, with pinned-in-place, pre-aligned components, ensures permanent optic alignment. With no instrumental variation introduced into spectral collections or calibrations, method transferability is ensured. In addition, method maintenance is virtually eliminated allowing for uninterrupted operation and analysis. The Antaris IGS analyzer provides the lowest CoO available in a gas system. The system also provides a long MTBF (> 5 years). Time-tested, high quality components are used in the construction of the system. With over 25 years of experience as the leader in FT-IR instrumentation, our laser, interferometer, source, and optical components have a proven performance track record. In addition, easy user-replaceable consumables, such as the IR source, minimize down time with no impact on data analysis or results. Error-free operation RESULT software allows deployment of SOP-based analyses which guarantee error-free performance, ensuring measurements are conducted consistently from measurement-to-measurement and from site-to-site.

A Complete System for Gas Analysis The Thermo Scientific Antaris IGS analyzer is a multi-component gas system capable of simultaneously analyzing over 100 gas species. Developed as an industrial Fourier Transform Infrared (FT-IR) system that can be deployed in either a rack-mount manufacturing environment or a table-top quality control area, the Antaris IGS provides the industry s highest possible performance in calibration and stability, method transferability, and high speed data acquisition. Total Solution The Antaris IGS gas analyzer was specifically developed to meet the needs of demanding gas applications. The analyzer s design and extensive support programs were developed with input from industry market leaders to offer a solution to your specific gas analysis needs. This analyzer is the first integrated gas analysis system to offer: Industrial rack-mount and table-top configurations Continuous quantitative analysis and visual display of gases in real-time High resolution research-grade system performance Integrated temperature control Intuitive, push-button operation System-to-system repeatability for method calibration transfer and simple method maintenance Powerful quantitative and qualitative capabilities Low Cost of Operation (CoO) Greater than five year Mean Time Between Failure (MTBF) MES and Process Control System (PCS) support Gas Analysis Capabilities With our extensive offering of gas spectral libraries and our dedicated gas calibration lab, we offer the widest variety of industry-specific or custom gas applications. Our factory calibration lab can provide gasoline, diesel, or catalyst combustion calibrations, fire science calibrations, compressed air or aviator breathing gas calibrations, and air bag effluent calibrations. Our worldwide global support team can provide support for on-site custom gas calibrations, as well as installation of standard gas calibrations available from our factory. Here s a partial list of components that can be analyzed by the Antaris IGS system. Acetaldehyde 1, 2-Dibromoethane Methyl nitrite Acetone Dichlorodifluoromethanc Nitric acid Acetylene Ethane Nitric oxide Acrolein Ethanol Nitrogen dioxide Ammonia Ethyl acetate Nitrogen trifluoride Arsine Ethyl acrylate Nitrous acid Benzene Ethylene Nitrous oxide Boron trichloride Ethylene oxide n-pentane Boron trifluoride Formaldehyde Phosgene Bromomethane Formic acid Phosphine 1, 3-Butadiene Furan Propane Butane n-hexane Styrene Carbon dioxide Hydrogen bromide Sulfur dioxide Carbon monoxide Hydrogen chloride Sulfur hexafluoride Carbon tetrachloride Hydrogen cyanide Silane Carbonyl sulfide Hydrogen fluoride Silicon tetrachloride CFC 11 Hydrogen sulfide Toluene CFC 12 Isobutanol Trichloroethylene CFC 13 Isobutylene Vinyl bromide CFC 14 Isopropanol Vinyl chloride CFC 22 Methane Water CFC 113 Methanol m-xylene Chlorodifluoromethane Methyl acrylate o-xylene Chloroethane Methyl amine p-xylene Chlorotrifluoromethane Methyl ethyl ketone Diborane Methyl isobutyl ketone

Features and Benefits of Antaris IGS Analyzer Feature Superior Performance best stability, signal-to-noise, resolution and reproducibility on the market Pinned-in-Place, Permanently Aligned Optica l Design Extensive Product and Application Support RESULT Analyzer Software TQ Analyst Chemometric Software for Method Development ValPro System Qualification Package and PQ Testing Benefits Fast analysis, capable of collecting and analyzing spectra at 2 scans per second at 0.5 cm -1 ; Spectral Range 6000 370 cm -1 ; Continuous operation with reproducible and accurate results; Low CoO; MTBF > 5 years Method transferability; Instrument-to-instrument accuracy and reproducibility Streamline your method development and validation; Industry and custom calibrations; On-site application development; Save time and money by shortening development Push-button operation; Simultaneous quantitative analysis of more than 100 gases; Minimal operation training, integrated SOP s; MES and PCS support Quantitative measurements: CLS, PLS, PCR, SMLR, Beer s Law Qualitative measurement including: QC compare, Search Standards, Similarity Match, Distance Match, Discriminant Analysis; Measure only mode: peak height, peak location, area, ratio, signal-to noise, center of gravity; Automatic method, region, pathlength, standard selection; Variety of pathlength and baseline correction tools; Diagnostic tools including Principle Components, Variance spectrum, Pure Component Spectra, Correlation Spectra, Cross Validation (RMSECV) Complete system performance verification including DQ, IQ, OQ; Designed in accordance with GLP and cgmp guidelines Automated Validation Wheel with Traceable Standards Automated performance verification that can be executed at any time; System verification with no possibility of operator error; Independent verification of spectrometer performance Internal Calibration No external calibration required; Instrument is precise to 0.01 cm -1 ; No artifacts due to instrumental variations Compact, Robust Design Small industrial footprint: Length 62cm (24.5 inches) x Width 43cm (17 inches) x Height 45cm (17.5 inches); 19 inch rack mount operation; Table-top operation; Operates in harsh, non-laboratory environments; Dual beampath design allows error-free verification of spectrometer and gas application without removal of gas cell Vectra Interferometer Time-tested, proven design that provides guaranteed, error-free operation for many years; Provides the highest performance in stability, accuracy and reproducibility User-Replaceable, Pre-Aligned Source Allows operators to quickly and easily change the source without changing analysis results or recalibrating the system; No - tools simplified parts replacement; Long lifetime source Gas Cell Options 10 meter gas cell; 2 meter gas cell; Accommodates a wide variety of industry-available gas cells from 0.5 to 20 meters Detector Options TE cooled DTGS; Liquid nitrogen cooled MCT (24 hour hold time) In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Africa +43 1 333 5034 127 analyze.emea@thermo.com Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50340 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 530 8447 analyze.ca@thermo.com China +86 10 5850 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com Europe-Other +43 1 333 5034 127 analyze.emea@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Middle East +43 1 333 5034 127 analyze.emea@thermo.com Netherlands +31 76 587 98 88 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 914 845 965 analyze.es@thermo.com Sweden / Norway / Finland +46 8 556 468 00 analyze.se@thermo.com Switzerland +41 61 48784 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Antaris IGS Analyzer From the Market Leader in Fourier Transform Infrared (FT-IR) Spectroscopy For over 25 years, Thermo Fisher Scientific has led the way in providing high performance, high quality molecular spectrometers. The Antaris IGS analyzer combines our expertise in FT-IR, FT-Raman, and FT-NIR spectroscopy with an innovative new design specifically developed as a dedicated gas analyzer. Extensive discussions with method developers and chemists in the gas industry have allowed us to develop an instrument that you can operate with complete confidence. Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified. 2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR50520_E 12/07M