Blood Pressure Training System S415

Similar documents
Arterial and Venous Patient Training Arm S

Five Year CPR and Trauma Care Simulator S151 S152

HAL Green CPR + D Trainer S

Adult Simon Airway Trainer S315/S

SUSIE AND SIMON NEWBORN

S113 & S114 & S

SUSIE and SIMON Newborn and Trauma Care Simulator S104

Five Year PEDI PALS Simulator for Advanced Life Support S155

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Newborn PEDI Simulator S

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Welcome to the S310 and S311. CPR Simon Basic Life Support. Instruction Manual

S Five Year PEDI PALS Simulator for Advanced Life Support with OMNI 2 User Guide

Gaumard Simulators for Health Care Education

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

SMART Oxygen Analyzer. User Manual

5 series Blood Pressure Monitor

Semi-Automatic Blood Pressure Monitor with Memory

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

DIAGNOSTIX TM 922 MERCURIAL BLOOD PRESSURE INSTRUMENT. Use, Care, & Maintenance

USE, CARE & MAINTENANCE DIAGNOSTIX TM 972 MERCURIAL BLOOD PRESSURE INSTRUMENT

S PREMIE HAL USER GUIDE. User Guide Gaumard Scientiic Company, All Rights Reserved

BLOOD PRESSURE SIMULATOR LF01095U INSTRUCTION MANUAL

WELCOME TO THE REVOLUTION

SPECIFICATIONS APCEPH1

Blood Pressure Simulator LF01095U Instruction Manual

WARRANTY, QUICK START GUIDE

Please Do Not Return This Product To The Store!

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Sports Wrist Digital Blood Pressure Monitor Item #

S109 NEWBORN PEDI USER GUIDE

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Section 2: Using the Invasive Blood Pressure Module - An Introduction

SMART Carbon Monoxide Analyzer. User Manual

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Getting to know your Sureshotgps micro V3

Dual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual

6 digital caliper with case

Prestan professional Training manikin

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

HAL S User Guide

Golf Performance Monitors. PureContact Operating Guide. Version of 9

S117 & S User Guide. Multipurpose Patient Care and CPR Pediatric Simulator

MODEL 100 NITROGEN INFLATION CART

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

MP15 Jockey Pump Controller

Modular skylight warranty

User s Manual. USB Golf Simulator. Contents

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

In Vivo Scientific, LLC INSTRUCTION MANUAL

Cocoa Patio Pond with Lit Spillway

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Cadence Sensor W.I.N.D. User Manual

4-in-1 Professional Inflator Kit

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Bleeding Trauma Module Set. Directions for Use

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

RAM 4021 Operation Manual

AED Trainer NF1200-T. Operator s Manual

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

RAM 4021-DPX Operation Manual

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

TactAir PCP Fill Kit/Adapter. Operation Manual

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

4 and 8 Station PDS Control Installation & Operators Manual

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

CSA Sample Draw Aspirator Adapter Operator s Manual

Owner s Manual W Automatic Aboveground Pool Cleaner

High Power Commercial Blenders

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Gateway. Parts Book Four Panel, Single & Double Adjustment Frames C-1105 SIEVE & CHAFFER SYSTEM. U.S. PATENT No AND FOREIGN PATENTS PENDING

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Blood Pressure Monitor

INSTRUCTION MANUAL S SIMON AIRWAY TRAINER. Gaumard Scientific Company, Inc SW 136 Street Miami, FL

GasLab SAN-102 Micro Oxygen Monitor User Manual

Overview. Front Panel: Keypad and Display

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

J Air and Water Kit Instructions Part# 02584

Owner s Manual Humiport 10/20

Gateway. Parts Book Three Panel, Double Adjustment Frames SIEVE & CHAFFER SYSTEM. U.S. PATENT No AND FOREIGN PATENTS PENDING

premium wrist blood pressure monitor

Revolution Gurney Attachment

HAS2400 Hepa Air Scrubber

The RICH LIFE Project: Blood Pressure Training Certification Checklists

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Thank you for choosing Xuma.

GasLab SAN-102 Micro Oxygen Monitor User Manual

453 Series Steam Heated Vaporizing Regulator

User s Guide. Pressure Controller for liquid delivery systems

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Transcription:

Blood Pressure Training System S415 Gaumard Simulators for Health Care Education The Blood Pressure Training System is an interactive educational system developed to assist a certified instructor. It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making. User Guide 12.7.1 Gaumard Scientific Company, 2012 All Rights Reserved www.gaumard.com

2 User Guide Blood Pressure Training System

Care and Cautions Overall Warnings... 5 General... 5 Latex warning... 5 Cleaning... 5 Operating Conditions... 5 Storage Conditions... 5 BP Arm Set Up Control Panel... 7 Power Supply... 7 Omni Setup... 7 Blood Pressure Arm Setup... 8 BP Arm Features Palpable Pulse... 10 Korotkoff Sounds... 10 Auscultation... 10 Instructions for use... 10 Using the Omni Blood Pressure Controller Omni... 12 Main Screen... 12 Omni Menus... 12 Pulse Menu... 13 Au. Gap menu... 13 Volume menu... 13 Calib menu... 13 Help... 14 Blood Pressure Training System User Guide 3

Care and Cautions 4 User Guide Care and Cautions

Overall Warnings Damage caused by misuse may void the manufacturer s warranty. Failure to comply with the following guidelines may result in injury or damage to the equipment. Additional warnings are found throughout the document. STORAGE CONDITIONS Improper storage may damage the simulator. Keep it stored in the box and/or bag provided. Do not stack or store heavy materials on top of the box and/or bag. Storage temperature: 32-113 F (0-45 C). Humidity: 40%-60% (non-condensing). GENERAL This simulator is constructed of material that approximates skin texture. Therefore, in handling the model, use the same gentle techniques as you would in working with a patient. Do not wrap this or any other Gaumard product in newsprint. Indelible marks made with ballpoint pens, ink or marker cannot be removed. Do not use alcohol, acetone, Betadine or any other antiseptic which contains iodine in this or any Gaumard simulator. These products could damage or stain the skin of the simulator. LATEX WARNING Vein tubing contains latex which may cause allergic reactions. Users allergic or sensitive to latex should avoid contact. Discontinue use of this product and seek medical attention if an allergic reaction occurs. CLEANING Clean the skin of the simulator after every training session. The skin should be cleaned with a cloth, dampened with diluted liquid dish washing soap. Do not clean with harsh abrasives. Do not use povidone iodine on the simulator. The simulator is splash-proof but not waterproof. Do not submerge or allow water to enter the interior of the simulator. OPERATING CONDITIONS Operating the Blood Pressure Training System outside these ranges may affect performance: Operating temperature: 50-95 F (10-35 C). Humidity: 5%-95% (non-condensing). Care and Cautions User Guide 5

BP Arm Set Up 6 User Guide BP Arm Set Up

Control Panel The control panel, located near the shoulder, provides quick access to all of the blood pressure arm connectors. Each connector is labeled for accessibility. Omni Setup Omni controls the Blood Pressure Training System with the touch of button. 1. Connect the communication cable to the port labeled Omni on the control panel. Power Supply 2. Connect the other end of the communication cable to Omni. 1. Unpack the system and place the blood pressure arm on a flat clean surface. Access to electrical power is required. 2. Connect the power supply to a wall outlet. 3. Connect the power supply cable to the power input on the control panel. A startup screen is shown while Omni is detecting the simulator features. After the start up screen, Omni will automatically proceed to the main screen. WARNING Do not connect the Blood Pressure Arm or Omni to a computer, LAN network or unauthorized diagnostic equipment using the communication cable (Ethernet cable). Doing so will cause serious damage to the equipment. BP Arm Set Up User Guide 7

Blood Pressure Arm Setup 1. Wrap the blood pressure cuff around the arm, midway between the deltoid and elbow. Ensure the arrow on the cuff points toward the elbow following the direction of blood flow in the artery. 2. Connect the blood pressure cuff extension to the connector labeled BP on the control panel. Reverse the setup steps to disassemble the simulator and turn off Omni. 8 User Guide BP Arm Set Up

BP Arm Features BP Arm Features User Guide 9

Overview 4. Slowly release the cuff and listen for Korotkoff sounds. The Blood Pressure Training System consists of a full-size adult left arm. This is a versatile training tool developed to assist health professionals teach the processes and skills required to perform blood pressure auscultation procedures and techniques. Features PALPABLE PULSE Programmable, palpable radial pulse is present when the cuff pressure is less than the selected systolic blood pressure. 5. Ask the provider to record the systolic pressure, the diastolic pressure, the limits of the auscultation gap (if any) and the pulse rate. 6. Compare the values recorded by the provider with those originally programmed in Omni. KOROTKOFF SOUNDS Korotkoff sounds, K1 through K4 (K5 is silence) are audible between systolic and diastolic pressures. The sounds are automatically silenced if the auscultation gap is enabled, and adjusted depending on the selected heart rate and the rate of cuff deflation. AUSCULTATION The simulator operates with a modified blood pressure cuff. Connect the BP cuff extension to the arm s control panel before use. Use a conventional stethoscope to auscultate Korotkoff sounds in the antecubital area. INSTRUCTIONS FOR USE 1. Follow the instructions listed in the Set Up section to assemble the simulator. 2. Place the bell of the stethoscope on the antecubital region of the arm. 3. Pump up the cuff until the radial pulse is absent. 10 User Guide BP Arm Features

Using the Omni Blood Pressure Controller Using the Omni Blood Pressure Controller User Guide 11

Omni Omni was designed to assist health professionals teach the processes and skills required to perform blood pressure auscultation procedures and techniques. NAVIGATION MENUS Edit Blood Pressure settings using the navigation menus. Select a menu item by pressing the soft key buttons located on the right side of the controller. Each menu has additional submenus. Use the submenus to decrease, increase, accept, or cancel values. MAIN SCREEN The Omni main screen is divided into three sections which are, Current Settings, Feedback Graphics and Navigation Menus. OMNI MENUS SET BP MENU Use this menu to set the blood pressure in the simulator. CURRENT SETTINGS Current settings information is listed in the upper center of the screen. FEEDBACK GRAPHICS The feedback graph located in the lower center of the screen displays, in real time, the BP cuff pressure. Select systolic or diastolic and adjust the pressure using the + and - buttons. Press OK to save the changes and return to previous screen. The default value for the blood pressure is 120/80 mmhg. 12 User Guide Using the Omni Blood Pressure Controller

PULSE MENU Use this menu to set the heart rate. Adjust the beats per minute using the + and - buttons. Press OK to save the changes and return to previous screen. VOLUME MENU AU. GAP MENU Increase or lower the volume of Korotkoff sounds using the VOLUME menu. Press OK to save the changes and return to previous screen. The default value for the Korotkoff sounds volume is 5. Enable and set an interval of pressure where Korotkoff sounds dissipate. The auscultatory gap is disabled by default. CALIB MENU Pressing the ENABLE button activates the UPPER and LOWER menus. Use these menus to set the limits of the auscultatory gap. Calibrate the sensors inside the simulator using this option. Set the standard against which auscultation will be evaluated during the exercise. Blood pressure cuff calibration should be performed only when the Korotkoff sounds do not match the systolic and diastolic values set from Omni. It is not necessary to re-calibrate Omni for each training session. Omni will remember previous calibration settings. CALIBRATION INSTRUCTIONS Adjust the limits of the auscultatory gap using the + and - buttons. Press OK to save the changes and return to previous screen. The default upper and lower limits for the auscultatory gap are 100 mmhg and 90 mmhg, respectively. 1. Assemble the system and turn Omni on. 2. Place the blood pressure cuff on the arm. 3. Connect the cuff s extension to connector on the control panel. Using the Omni Blood Pressure Controller User Guide 13

4. Select the CALIB menu from the main screen. After pressing the DEFAULT button, a message on the screen will notify the user about the status of the reset. HELP 5. Press NEXT to begin the calibration procedure. 6. You will be prompted to set the BP cuff to a certain pressure. Hold that pressure constant and press the NEXT button. The help window provides access to global settings such as backlight time and Omni/ Simulator serial number. This menu is available in the main screen and throughout the control menus for convenience. BACKLIGHT 7. Omni will now prompt you to set the BP cuff to 20 mmhg. Hold that pressure constant and press the NEXT button. The default value for Omni s backlight timer is 10 minutes. After 10 minutes the backlight will turn off. To alter the backlight duration, adjust the backlight timer with the plus or minus sign. Press OK to accept the changes. Follow the text cue on the screen and repeat the procedure for each pressure level. The facilitator should follow the text cue on the screen to inflate the cuff just one value at a time, until finished. After calibrating the sensor, Omni will return to the main screen and display the reading shown on the sphygmomanometer. SERIAL NUMBER View Omni and simulator serial number. Press OK to return to the HELP menu. FACTORY SETTING The DEFAULT option is used to restore sensors back to factory settings, erasing any calibrations performed by users. When restoring the sensors to factory settings, do not practice auscultation. This action will interfere with the reset. 14 User Guide Using the Omni Blood Pressure Controller

Appendix Appendix User Guide 15

Troubleshooting GENERAL TROUBLESHOOTING GUIDE Use the following table to find causes and solutions to a number of possible problems. Symptom Communication never gets established or is lost Possible Cause Data cable is not connected Ethernet cable is damaged Solution Ensure the Ethernet cable is plugged into Omni and the simulator Verify the power cable is connected to the simulator Consumables and Replacements SELECTED PARTS LIST Contact Gaumard Scientific for a complete list of consumable and replacement parts and their prices. Item ID Description S415.002 Blood Pressure Cuff Kit S415.003 Soft Carrying Bag fir Arm S415.008 2 Arm Skins S415.009 Synthetic Blood Concentrate S415.010 Speakers No radial pulse Pulse rate was set to 0 BPM Increase the pulse rate using the pulse menu S415.180 Omni Controller S415.005 Power Supply 100-240 VAC The readings from the simulator do not match Omni Improper calibration Calibrate simulator following the calibration instructions listed in the Using the Omni section S415.180.1 S415.180.2 Communication Cable USB Cable Korotkoff sounds are absent or not heard at desired volume level Volume level is set to low Adjust the volume control to get it to desired level 16 User Guide Appendix

Warranty EXCLUSIVE ONE-YEAR LIMITED WARRANTY Gaumard warrants that if the accompanying Gaumard product proves to be defective in material or workmanship within one year from the date on which the product is shipped from Gaumard to the customer, Gaumard will, at Gaumard s option, repair or replace the Gaumard product. This limited warranty covers all defects in material and workmanship in the Gaumard product, except: Damage resulting from accident, misuse, abuse, neglect, or unintended use of the Gaumard product; Damage resulting from failure to properly maintain the Gaumard product in accordance with Gaumard product instructions, including failure to property clean the Gaumard product; and Damage resulting from a repair or attempted repair of the Gaumard product by anyone other than Gaumard or a Gaumard representative. This one-year limited warranty is the sole and exclusive warranty provided by Gaumard for the accompanying Gaumard product, and Gaumard hereby explicitly disclaims the implied warranties of merchantability, satisfactory quality, and fitness for a particular purpose. Except for the limited obligations specifically set forth in this one-year limited warranty, Gaumard will not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory regardless of whether Gaumard has been advised of the possibilities of such damages. Some jurisdictions do not allow disclaimers of implied warranties or the exclusion or limitation of consequential damages, so the above disclaimers and exclusions may not apply and the first purchaser may have other legal rights. This limited warranty applies only to the first purchaser of the product and is not transferable. Any subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply. This limited warranty applies only to the products manufactured and produced by Gaumard. This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties. For example, third-party products such as computers (desktop, laptop, tablet, or handheld) and monitors (standard or touch-screen) are not covered by this limited warranty. Gaumard does not provide any warranty, express or implied, with respect to any third-party products. Defects in third-party products are covered exclusively by the warranty, if any, provided by the third-party. Any waiver or amendment of this warranty must be in writing and signed by an officer of Gaumard. In the event of a perceived defect in material or workmanship of the Gaumard product, the first purchaser must: 1. Contact Gaumard and request authorization to return the Gaumard product. Do NOT return the Gaumard product to Gaumard without prior authorization. 2. Upon receiving authorization from Gaumard, send the Gaumard product along with copies of (1) the original bill of sale or receipt and (2) this limited warranty document to Gaumard at 14700 SW 136 Street, Miami, FL, 33196-5691 USA. 3. If the necessary repairs to the Gaumard product are covered by this limited warranty, then the first purchaser will pay only the incidental expenses associated with the repair, including any shipping, handling, and related costs for sending the product to Gaumard and for sending the product back to the first purchaser. However, if the repairs are not covered by this limited warranty, then the first purchaser will be liable for all repair costs in addition to costs of shipping and handling. Extended Warranty In addition to the standard one year of coverage, the following support plans are available: Two-Year Extension (covers second and third years) Call for pricing (USA only) Appendix User Guide 17

Contact Us E-mail Technical Support: support@gaumard.com Before contacting Tech Support you must: 1. Have the simulator s Serial Number 2. Be next to the simulator if troubleshooting is needed. E-mail Sales and Customer Service: sales@gaumard.com Phone: Toll-free in the USA: (800) 882-6655 Worldwide: 01 (305) 971-3790 Fax: (305) 667-6085 Post: Gaumard Scientific 14700 SW 136 Street Miami, FL 33196-5691 USA Office hours: Monday-Friday, 8:30am - 4:30pm EST (GMT-5, -4 Summer Time) General Information Gaumard, ZOE, Michelle, Mike, PEDI, Susie Simon, Susie, Simon Code Blue, SIMA Models, SIMA GYN/AID, Virtual Instruments, Codemaker, Code Blue, NOELLE, Simulation Made Easy, HAL, CPRLink, Zack, RITA, Chloe, Seatbelt Susie, Krash Kids, Premie, GIGA, Omni, SmartSkin are Trademarks of Gaumard Scientific Company, 2012 All rights reserved. Gaumard, NOELLE, HAL are trademarks of Gaumard Scientific Company, Inc. Patented; Other Patents Pending Always dispose of this product and its components in compliance with local laws and regulations.